| HS Code | 195968 |
| Product Name | Parker Chomerics CHO-FOIL CCK Shielding Tape |
| Product Type | EMI Shielding Tape |
| Backing Material | Copper Foil |
| Adhesive Type | Conductive Acrylic |
| Total Thickness | 0.0035 in (0.089 mm) |
| Copper Foil Thickness | 0.0014 in (0.036 mm) |
| Adhesive Thickness | 0.0021 in (0.053 mm) |
| Surface Resistance | 0.01 ohm/sq |
| Shielding Effectiveness | > 100 dB |
| Operating Temperature Range | -40°C to 125°C |
| Flammability Rating | UL 94 V-0 |
| Rohs Compliance | Compliant |
| Shelf Life | 12 months |
| Color | Copper |
As an accredited Parker Chomerics CHO-FOIL CCK Shielding Tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaged as one roll per carton; tape is wound on a core and enclosed in a labeled cardboard dispenser box. |
| Container Loading (20′ FCL) | Parker Chomerics CHO-FOIL CCK Shielding Tape loaded in 20-foot FCL container, palletized, secured, kept dry, and compliant with transport regulations. |
| Shipping | Parker Chomerics CHO-FOIL CCK Shielding Tape is not classified as dangerous goods for transport. It has no UN number, hazard class, or packing group under DOT, IATA, IMDG, or ADR. Ship at ambient temperature in original, dry packaging, avoiding excessive heat, moisture, and physical damage. |
| Storage | Store in original, sealed packaging in a cool, dry, well-ventilated area. Keep away from heat, sparks, open flames, and direct sunlight. Maintain moderate temperature, ideally 15–30°C (59–86°F), with low humidity. Do not freeze. Protect from moisture, dust, and physical damage. Keep containers closed when not in use. Observe shelf life and follow manufacturer’s SDS/storage instructions. |
| Shelf Life | Typically shelf life is 12 months from date of manufacture when stored in original unopened packaging at 20–25°C and 50% RH. |
Parker Chomerics CHO-FOIL CCK shielding tape is a copper-foil-backed conductive pressure-sensitive acrylic adhesive system supplied on a release liner and converted in roll, slit, or die-cut form. In commercial networking hardware, the tape is used as a seam bridge across mating zinc-plated steel, aluminum, and stainless-steel enclosure flanges after pre-cleaning with 70% isopropanol or a 50:50 isopropanol/deionized water mixture. Surface preparation removes alcohol-soluble die lubricants and condensation residues; hydrocarbon stamping oils and silicone-based mold release agents reduce peel adhesion by more than 50% under production conditions. The tape is roll-applied with a silicone-free pressure roller at tangent pressure between 30 psi and 60 psi (200 kPa to 400 kPa), followed by a 24 h dwell at 23 ± 2°C to allow full adhesive wet-out. The tape path is specified to cover a minimum of 3 mm on each side of a 0.2 mm seam gap, yielding a seam overlap ratio of 30:1 relative to the gap width. For flanges with paint-step edges greater than 0.3 mm, the tape is applied in a continuous single pass rather than segmented patches because patch joints create shield discontinuities. Material compliance documentation references RoHS Directive 2011/65/EU and REACH Regulation 1907/2006; end-use exemptions under Annex III of RoHS are evaluated by the system integrator. Compliance under FCC Part 15 Subpart B and EMC Directive 2014/30/EU is evaluated after tape installation using CISPR 32 radiated emission measurement methods; finished products include 48-port Ethernet switches, rack-mount storage controllers, and fiber-optic transceiver chassis.
Avionics harness shops use CHO-FOIL CCK in continuous spiral wraps over shielded twisted pairs, shielded quads, and quadrax cable where soldered braid transitions create local impedance discontinuities and shield leakage. The tape is applied at 50% minimum overlap; overlaps below 40% create a shield gap at flex points after thermal cycling from −40°C to +70°C, a range representative of unpressurized cargo bay areas. The copper foil is cut to a width at least three times the cable outer diameter to maintain a helix angle between 25° and 35°. In this wrap configuration, the conductive acrylic adhesive is not the primary current path; current transfer occurs through foil-to-foil contact at each overlapping turn. The tape edge is terminated with self-locking stainless-steel band ties or copper drain-wire saddles bonded with conductive epoxy, not with solder, because the adhesive backing contaminates the solder fillet and causes microvoid formation. Incoming peel adhesion is tested per ASTM D3330/D3330M-04; published data for the exact CHO-FOIL CCK adhesion after 1000 h exposure to turbine oil mist is limited, so qualification programs include extended adhesion batch release before airframe installation. Full harness emission testing is performed to RTCA DO-160G Section 21 Category M and MIL-STD-461G RE102 after the tape settles for 24 h at 22 ± 1°C and 40% RH. Finished products include airframe harness bundles, line-replaceable unit pigtails, and galley power feeders.
Handheld medical and data-capture terminals incorporate polyimide flexible circuits that return ground at dynamic fold points. CHO-FOIL CCK is die-cut into tabs with 1 mm radius corners and laminated to the backside of the polyimide circuit under a heated platen press at 50°C; press dwell is 5 s to 8 s, and pressure is limited to 0.3 MPa to 0.5 MPa to avoid compressive yielding of the copper foil. The conductive acrylic adhesive maintains contact to electroless nickel immersion gold land pads when the flex circuit is bent to a 0.5 mm radius; bend fatigue evaluation follows IPC-TM-650 Method 2.4.3, with pass/fail defined as no conductor resistance increase greater than 10% after 100,000 cycles. The acrylic adhesive layer is not reflow-solderable, so termination on the rigid board is performed by laser-welded or anisotropic conductive film bonds before tape application. This sequencing separates the tape from solder paste exposure above 217°C, where the acrylic system softens and loses dimensional stability. Incoming surface resistivity is verified at 0.010 Ω/square maximum under ASTM D257, and contact resistance is measured at 1 A through the tape-to-pad interface per MIL-STD-202 Method 307. Finished assemblies include barcode scanners, wearable patient monitors, and point-of-sale handhelds.
Automotive battery management units and DC-DC converter housings use CHO-FOIL CCK as a local seam shield across polycarbonate/ABS enclosure halves that have been electroless-nickel or copper-masked coated. The tape is applied before clip assembly; bonding surfaces are flame-treated to a dyne level of 40 mN/m to 44 mN/m, because untreated PC/ABS below 36 mN/m produces adhesive wet-out failure. The tape is not selected for load-bearing mechanical retention; nylon snap features and threaded bosses supply clamping force. Tape widths of 5 mm and 10 mm are used to bridge parting lines up to 0.15 mm. Modules are tested to CISPR 25:2021 Class 5 conducted and radiated emission limits; immunity is evaluated according to ISO 11452-2 radiated fields over 200 MHz to 18 GHz. Thermal storage at 85°C for 1000 h per ISO 16750-4 is used to detect copper oxidation and adhesive embrittlement at liner removal; if the liner is left in place during clip installation, trapped liner fragments under the tape create an insulation void. Finished products include 48 V mild-hybrid battery management systems, onboard charger modules, and electric power steering controllers.
| Application segment | Reference standard | Test condition | Typical acceptance criterion |
|---|---|---|---|
| Commercial electronic seams | FCC Part 15 Subpart B, CISPR 32 | 30 MHz–1 GHz radiated emission | Class B limit |
| Avionics harness shielding | RTCA DO-160G Section 21, MIL-STD-461G RE102 | Platform-specified frequency range | Airframer defined margin |
| Flex circuit grounding | IPC-TM-650 Method 2.4.3, MIL-STD-202 Method 307 | 0.5 mm bend radius, 100,000 cycles | ≤10% resistance increase |
| Automotive module shielding | CISPR 25:2021, ISO 11452-2 | 200 MHz–18 GHz radiated | Class 5 |
| 5G remote radio head grounding | ETSI EN 301 489-1 | 30 MHz–18 GHz EMC | Harmonized essential requirements |
| In vitro diagnostic analyser shielding | IEC 60601-1-2:2014 | 80 MHz–6 GHz | CISPR 11 Group 1 Class A/B |
Remote radio units and active antenna units require low-inductance grounding from metalized plastic antenna frames to aluminum backplates. CHO-FOIL CCK is applied over formed 0.1 mm to 0.3 mm joint gaps in place of discrete riveted bus bars. The foil path is jigged so that the current flow is parallel to the roll direction of the copper; the tape exhibits anisotropic mechanical work hardening after repeated peel cycles. A double-layer stack is used only where the seam step exceeds 0.4 mm, because a single ply loses contact over step discontinuities above that height. Production lines apply the tape with a heated roller at 40°C to 45°C to accelerate adhesive wet-out, followed by a 15 psi to 20 psi static roller pass in the same axis. Electrical integrity is measured with a micro-ohmmeter using a 100 mA test current; a common OEM acceptance criterion is 25 mΩ or less across a 50 mm seam. Compliance is assessed under ETSI EN 301 489-1 and thermal cycling from −40°C to +85°C; finished products include 5G remote radio heads, baseband chassis, and antenna filter units.
Clinical chemistry and immunoassay analysers use CHO-FOIL CCK around photomultiplier tube housings and motor controller enclosures. The tape is applied only to non-patient-contact internal surfaces; the copper surface is not biocompatible and must not be placed on applied parts as defined in IEC 60601-1. A compressed foil thickness of 0.2 mm to 0.3 mm is achieved by overlaying a 12 mm wide strip on a 1.5 mm deep recess. The adhesive bond is exposed to 10% vaporized hydrogen peroxide or quaternary ammonium disinfectant wipe cycles; bleach-containing disinfectants at pH > 10 are incompatible with the acrylic adhesive over repeated cycles. Shielding effectiveness is measured in a stirred-mode reverberation chamber according to IEC 61000-4-21; pre-compliance screening uses IEEE 299 flanged coaxial fixture. Published data for CHO-FOIL CCK shielding performance above 18 GHz is limited; measurements above 26.5 GHz require user-specific validation because fixture aperture resonances dominate. Terminal products include automated immunoassay platforms, hematology analyzers, and PCR thermal cyclers.
Competitive Parker Chomerics CHO-FOIL CCK Shielding Tape prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Parker Chomerics CHO-FOIL CCK shielding tape consists of a 0.036 mm (0.0014 in) rolled copper foil coated on one side with an electrically conductive acrylic pressure-sensitive adhesive. The product is supplied in CCK-18, CCK-36, and CCK-72 roll formats, corresponding to 18 yd (16.5 m), 36 yd (32.9 m), and 72 yd (65.8 m); common converter widths range from 12.7 mm to 610 mm. The release liner is removed during die cutting or at the application head, exposing the conductive adhesive for direct bonding to enclosure flanges, cable shields, and ground-plane surfaces. Typical applications include seam shielding on injection-molded enclosures, grounding of I/O connector gaskets, field repair of shielded rooms, and conductive bonding of fabric-over-foam EMI gaskets. The total tape thickness is nominally 0.099 mm to 0.110 mm, measured in accordance with ASTM D1000; the copper face is unplated, which preserves solderability but requires corrosion management in wet environments.
Compared with nonconductive acrylic copper tapes, CCK provides a through-conductive bond line rather than a capacitive gap. Compared with aluminum foil tapes, it offers lower volume resistivity and better low-frequency shielding per unit thickness but higher galvanic mismatch with aluminum substrates. The conductive adhesive is not a nonconductive mounting adhesive; its electrical continuity is the primary specification driver in grounding and seam-shielding applications.
| Property | Method | Typical value |
|---|---|---|
| Total tape thickness | ASTM D1000 | 0.099–0.110 mm |
| Copper foil thickness | ASTM D1000 | 0.036 mm |
| Copper surface resistivity | ASTM F390 | ≤0.010 Ω/sq |
| Adhesive bond-line resistance | MIL-STD-202G Method 307 | ≤0.010 Ω/in² |
| Peel adhesion to stainless steel | ASTM D1000 | ≥4.4 N/mm |
| Breaking strength | ASTM D1000 | ≥61 N/25 mm |
| Elongation at break | ASTM D1000 | ≤5% |
| Service temperature | Manufacturer rated | −40 °C to 70 °C |
| Plane-wave shielding effectiveness | IEEE 299 | >80 dB from 30 MHz to 1 GHz |
This table is a compilation of manufacturer-reported typical values; lot-specific certificates may vary because conductive acrylic formulations can shift with filler type, coat weight, and liner lot. Compliance statements should be requested per RoHS Directive 2011/65/EU and REACH Regulation EC 1907/2006 for the specific roll or converted part.
Shielding effectiveness for a seam tape is controlled by aperture geometry once the foil is electrically continuous. At 30 MHz, skin depth in pure copper is approximately 21 μm, so the 36 μm foil exceeds one skin depth and contributes both reflection and absorption loss. At 1 GHz, skin depth decreases to approximately 2.1 μm, but enclosure-seam measurements often degrade to 40–60 dB when the tape edge is not burnished or when the flange gap exceeds 0.1 mm. Slot-aperture leakage is proportional to aperture length; even a 0.5 mm gap can dominate the shielding budget. For continuous grounding, the tape must be applied over a closed seam and rolled with a conductive or nonconductive pressure roller to displace entrapped air. The conductive adhesive cannot bridge a 0.2 mm step on anodized flanges; an electrically bonded gasket or mechanical compression is required.
Transfer impedance, not DC resistance alone, is the more relevant parameter for seam leakage below 100 MHz. For a seam tape, transfer impedance is influenced by the number of conductive paths through the adhesive and by the contact area. The conductive adhesive’s particle network is stochastic; under compression, through-resistance decreases with pressure up to approximately 2.1 MPa, beyond which foil deformation and adhesive squeeze-out can reduce the bond line. Published data for this specific configuration is limited, so in-process verification should be conducted on the actual flange geometry.
Testing per MIL-STD-285 or IEEE 299 should use the assembled seam, because tape coupon data over a uniform metal substrate overestimates enclosure-level isolation. At frequencies below 1 MHz, copper has limited magnetic-field shielding performance because relative permeability is approximately unity. High-permeability alloys such as mu-metal are required for low-frequency magnetic attenuation. Published measurement data for CCK in low-frequency magnetic-field shielding configurations is limited; qualification should be performed in the installed enclosure geometry.
Automated enclosure lines typically apply CCK from a roll-fed head with 60 Shore A silicone nip rollers. A nip pressure of 0.14–0.28 MPa (20–40 psi) is sufficient to eliminate visible air channels on rigid flanges; however, roller alignment across the flange should deviate no more than ±0.05 mm per 100 mm to prevent adhesive void formation. Die-cut converters process CCK on rotary or flatbed presses with air-cycled ejection to control adhesive stringing. Peeled liner release values are typically in the 0.05–0.15 N/cm range at 180°; liner removal must be conducted under ionized air if the work area has a static potential above 100 V.
Die-cutting copper foil produces greater tool wear than aluminum foil tape. Rotary dies require carbide or powdered-metal blades, and edge burr formation can begin when blade clearance exceeds 0.012 mm. Roll-to-roll variation in adhesive coat weight is typically controlled to ±5% of nominal; incoming inspection should include surface-resistance mapping across the roll width at 100 mm intervals using MIL-STD-202G Method 307 to identify high-resistance islands caused by conductive filler distribution.
The conductive acrylic pressure-sensitive adhesive in CCK has a measurable drop in peel strength when the substrate critical surface tension falls below 38 mN/m. On stainless steel panels cleaned with reagent-grade isopropyl alcohol, manufacturer-reported peel adhesion exceeds 4.4 N/mm; on untreated polypropylene or heavily silicone-contaminated surfaces, values below 1.8 N/mm are commonly observed. The adhesive is not load-bearing under sustained peel or shear: sustained static load should not exceed 0.35 N/cm at 23 °C, and elevated temperature reduces this limit. The tape provides an electrical path but does not replace screws, snap features, or compression gaskets in structural grounding connections.
Surface preparation has greater influence on long-term adhesion than initial tack. Mold-release residues, silicone oils, and plasticizer haze should be removed with reagent-grade isopropyl alcohol or a 50:50 isopropyl alcohol/deionized water solution, followed by lint-free wipe drying. For molded polycarbonate/ABS and polyphenylene oxide blends, plasma or corona treatment should raise the surface energy above 38 mN/m before tape placement. Peeling a sample at 90° and 300 mm/min after 20 min dwell is a practical incoming inspection method; full adhesion develops over 24–72 h depending on temperature and substrate polarity.
One failure mode observed on production lines is edge lifting after 72 h due to springback on curved flanges. Radial bends tighter than 12 mm require heat forming at 40–50 °C or mechanical clipping. On conductive fabric-over-foam gaskets, CCK is used to bond the gasket to an enclosure flange. The tape’s through-bond resistance is lower than a nonconductive pressure-sensitive adhesive, but total joint resistance is dominated by the gasket-to-tape interface, not the tape itself.
CCK has an unplated copper surface, and direct application to aluminum flanges creates a galvanic couple in condensing humidity. The standard reduction potential for copper is +0.34 V versus standard hydrogen electrode, while aluminum is −1.66 V versus SHE; the resulting potential difference is 2.00 V. If a continuous electrolyte film forms at the tape edge, the aluminum flange becomes the anode and can pit. Indoor electronic equipment maintained below 60% RH with minimal thermal condensation is generally compatible, but outdoor or marine enclosures require a tin-plated copper tape, a nickel-plated copper tape, or an insulating overcoat applied over the tape edge.
When CCK is used on aluminum, the joint should be electrically sealed or mechanically protected within 24 h of application in high-humidity conditions. A 50 μm acrylic or polyurethane overcoat applied over the tape edge reduces electrolyte ingress but does not eliminate the underlying couple if moisture is already trapped. Users should avoid placing CCK in direct contact with unpainted galvanized steel without a compatibility check, because the copper-zinc couple can also produce corrosion under wet storage.
| Material system | Volume resistivity at 20 °C | Low-frequency magnetic shielding | Corrosion behavior on aluminum flanges |
|---|---|---|---|
| CCK unplated copper | 1.72 × 10−8 Ω·m | Limited below 10 kHz | Galvanic risk if wetted |
| Aluminum foil tape | 2.65 × 10−8 Ω·m | Limited below 10 kHz | Lower galvanic mismatch with aluminum |
| Tin-plated copper foil tape | 1.72 × 10−8 Ω·m | Limited below 10 kHz | Improved corrosion resistance at edges; intermetallic growth at soldered overlaps |
On cable-shield applications, CCK is spiral-wrapped with 50% overlap under 4.4 N tension; the wrapped shield must maintain at least 0.25 mm separation from signal conductors to avoid capacitance loading. The conductive adhesive secures the overlap region, but mechanical cable ties or shrink tube are required for vibration environments above 10 g rms. On printed circuit board ground-plane repairs, the copper foil can be soldered at its edges; soldering temperatures above 232 °C for more than 3 s can compromise the acrylic adhesive bond line, so heat sinking or low-temperature solder is used when the tape is not mechanically clamped.
Storage at 21 ± 3 °C and 50 ± 10% RH is specified for a 12-month shelf life. Rolls should not be stored below 5 °C before application; condensation during thawing can create microvoids at the adhesive-copper interface. High humidity accelerates copper oxide growth on exposed edges, which may require edge trimming prior to use. Direct contact with PVC containing uncured plasticizer or with room-temperature acetoxy-cure silicones should be avoided; plasticizer migration reduces peel strength, and acetic acid accelerates copper tarnish. Neutral-cure silicones are preferred when adjacent sealing operations release cure byproducts.