Products

Parker Chomerics CHO-FOIL CCE Shielding Tape

    • Product Name: Parker Chomerics CHO-FOIL CCE Shielding Tape
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 470677
    Product Name Parker Chomerics CHO-FOIL CCE Shielding Tape
    Product Code CHO-FOIL CCE
    Manufacturer Parker Chomerics
    Product Series CHO-FOIL
    Product Type Electrically Conductive EMI Shielding Tape
    Backing Material Copper Foil
    Adhesive Type Conductive Acrylic
    Total Thickness 3.5 mil (0.089 mm)
    Width 1 in (25.4 mm)
    Length 36 yd (32.9 m)
    Color Copper
    Operating Temperature Range -40°C to 121°C (-40°F to 250°F)
    Shielding Effectiveness 70 dB (30 MHz to 1 GHz)
    Rohs Compliance Yes

    As an accredited Parker Chomerics CHO-FOIL CCE Shielding Tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Parker Chomerics CHO-FOIL CCE Shielding Tape is packaged as one roll per package in protective wrapping for safe storage.
    Container Loading (20′ FCL) 20′ FCL container loaded with palletized Parker Chomerics CHO-FOIL CCE Shielding Tape, securely strapped, dry, and compliant with transport regulations.
    Shipping Parker Chomerics CHO-FOIL CCE Shielding Tape is not classified as dangerous goods for transport. It is shipped as non-hazardous general cargo by road, air, or sea. No UN number, hazard class, packing group, or special transport label is required. Store in original packaging, dry, and avoid extreme temperatures.
    Storage Store CHO-FOIL CCE Shielding Tape in original sealed packaging in a cool, dry, well-ventilated area. Keep away from direct sunlight, heat, moisture, sparks, and ignition sources. Maintain temperatures between 10–30°C and relative humidity below 70%. Avoid contact with solvents, acids, and bases. Do not stack heavy items on rolls. Rotate stock and use within the manufacturer’s recommended shelf life.
    Shelf Life Shelf life is 12 months from date of manufacture when stored in original packaging at 23°C and 50% relative humidity.
    Application of Parker Chomerics CHO-FOIL CCE Shielding Tape

    What Limits Shielding Effectiveness in Outdoor 5G Radio Seam Taping?

    In outdoor 5G remote radio units, the dominant shielding failure is not bulk penetration but seam impedance rise across machined aluminum split lines, where casting tolerances leave gaps between 0.15 mm and 0.30 mm. CHO-FOIL CCE tape is introduced as a conformal copper bridge; the addition ratio for lot acceptance is a copper foil thickness of 0.035 mm laminated to a conductive acrylic adhesive of 0.025 mm, a metal-to-adhesive thickness ratio of 1.4:1. Master rolls supplied at 25.4 mm width are slit downstream to 6.0 mm strips; for a nominal 2.0 mm seam, this yields a 3:1 tape-width-to-seam-gap ratio, leaving 2.0 mm of adhesive contact on each flange. Compliance on the finished radio is tested to CISPR 32:2015 Class A radiated emission limits, ETSI EN 301 489-1 EMC requirements, and IEC 61000-4-3:2020 radiated immunity at 10 V/m from 80 MHz to 6 GHz. The downstream production process begins with a 70:30 isopropanol/deionized-water wipe, then a 40 kHz atmospheric plasma treatment at 0.5 m/min to raise aluminum surface energy above 48 mN/m; the tape is laminated with a pneumatic roller at 0.35 MPa and 23 °C, dwelled for 5 s. Process conflict arises when cast aluminum roughness exceeds 3 µm Ra: air entrapment in the adhesive layer creates high-frequency leakage, so polished flanges or additional roller passes at 0.50 MPa are required. When conductive elastomer gaskets are present, the tape must not bridge the gasket groove because dual compression paths create low-frequency discontinuities; in such cases the tape is segmented into 25 mm lengths with 1 mm gaps. Terminal product types include remote radio heads, active antenna units, and outdoor baseband RF modules.

    Medical ultrasound carts and multi-parameter patient monitors rely on conductive foil tape to return FPGA-generated 5.0 GHz clock harmonics to the chassis before they couple onto the flexible transducer cable. The tape is applied as 12.7 mm wide strips centered over the polycarbonate/ABS shield wall seam; for a 1.0 mm joint, this leaves 5.85 mm of adhesive contact on each side. The construction ratio is 0.035 mm copper foil to 0.025 mm conductive acrylic adhesive, a 1.4:1 thickness ratio, and no secondary adhesive or primer is introduced because solvent-borne primers stress-crack polycarbonate. Compliance is established under IEC 60601-1-2:2014+AMD1:2020, requiring 10 V/m radiated immunity from 80 MHz to 2.7 GHz in professional healthcare facilities, plus conducted emissions measured to CISPR 11 Group 1 Class A limits. The downstream production process uses a spring-loaded manual roller with a peak pressure of 0.4 MPa and a 30 s dwell at 60 °C maximum enclosure surface temperature; above 65 °C, polycarbonate shows stress-whitening around screw bosses. RoHS compliance is required under 2011/65/EU as amended by (EU) 2024/210; ISO 10993 biocompatibility testing is not triggered because the tape is not patient contacting in normal use. Terminal product types include ultrasound mainframes, central monitoring stations, and telemetry transmitters.

    Battery Management Module Enclosures and Conductive Foil Tape Return Paths

    At the module level, low-frequency conducted emissions from silicon-carbide MOSFET switching in the 100 kHz to 50 MHz band couple onto the aluminum BMS cover through 1.5 mm machined seams, producing radiated emissions that exceed CISPR 25:2021 Class 5 limits if the seam is not bridged. CHO-FOIL CCE tape strips are kiss-cut to 8.0 mm width and applied between the nickel-plated copper busbar shield and the chromate-passivated housing flange; the dry adhesive coat weight is 35 g/m² on 0.035 mm copper foil, giving a construction ratio of 1.4:1 by thickness. Compliance also requires ISO 11452-2:2019 radiated immunity from 200 MHz to 18 GHz at 100 V/m, and REACH SVHC screening under EC 1907/2006. The downstream process begins with acetone-free solvent cleaning, then tape application at 0.30 MPa roller pressure for 10 s; cover screws are torqued to 0.8 N·m within 15 min of tape placement. Operational boundary: the acrylic adhesive softens above 125 °C; continuous service above 85 °C at the bond line is not recommended. Finished products include cell supervisory circuits, battery management electronic control units, and DC-DC converter enclosures.

    RTCA DO-160G Section 20 radiated susceptibility levels for avionics equipment do not directly assign shielding-tape overlap dimensions, so qualification engineers impose a 10 mΩ DC bond criterion across the seam before MIL-STD-461G RS103 and CS114 testing. CHO-FOIL CCE tape is die-cut to 19.05 mm width, bridging a 1.0 mm seam with a 6.35 mm overlap on each flange; the addition ratio is 0.035 mm electrodeposited copper to 0.025 mm conductive acrylic adhesive, with liner release force controlled at 0.30 N/25 mm to prevent delamination during automated tape placement. Outgassing data per ASTM E595-15(2021) are reported by the manufacturer only for specific lots; published data for this specific configuration in space-grade programmes is limited. The production process uses a benchtop pneumatic press with 0.50 MPa pad pressure for 20 s, followed by 72 h room-temperature dwell before final continuity measurement. Terminal products include flight management computers, navigation display processors, and transponder chassis.

    Across tablet and notebook display grounding, the pressure-sensitive adhesive layer must maintain z-axis conductivity while absorbing 0.3 mm dynamic displacement between the LCD rail and magnesium chassis during drop testing. FCC Part 15 Subpart B and EN 55032:2015+A1:2020 set Class B radiated emission limits of 30 dBµV/m at 10 m from 1 GHz to 6 GHz, and the grounding path is required to survive 10000 mechanical cycles without impedance rise above 1 Ω. CHO-FOIL CCE tape is rotary die-cut to 2.0 mm width tabs with 0.5 mm radiused corners; the construction ratio is 0.035 mm copper foil to 0.025 mm conductive acrylic adhesive. In production, tabs are placed at 4.0 mm intervals along the display rail using a pick-and-place head with 0.25 MPa contact pressure, then post-bonded at 80 °C for 15 min to complete acrylic wet-out on the magnesium surface. No primer is used because of the risk of chloride-induced corrosion at the tape edge. Terminal products include ultrabooks, detachable tablets, and handheld gaming devices.

    When QSFP-DD Cage Grounding Fingers Degrade After Repeated Insertion

    Grounding returns in 400G optical line cards require copper-to-chassis bonds with impedance below 5 mΩ at 100 MHz; QSFP-DD cage spring fingers alone exhibit rising contact resistance after 50 insertion cycles. CHO-FOIL CCE tape is die-cut to 10.0 mm × 5.0 mm pads and placed between the gold-plated PCB pad and the cage flange after SMT reflow; the material construction ratio is 0.035 mm copper foil to 0.025 mm conductive acrylic adhesive, with adhesive coat weight of 25 g/m² on the release liner. Compliance is evaluated under CISPR 32:2015 Class A conducted emission limits, IEC 62368-1:2023 earthing and bonding clauses, and GR-1089-CORE Issue 8 for network equipment electromagnetic compatibility. The downstream process uses a vacuum pick-and-place tool, then a press-down force of 5 N per pad for 3 s; rework is limited to one replacement cycle because the acrylic adhesive leaves residual carbon filler on the gold pad. Terminal products include data center spine switches, server line cards, and optical transceiver adapter cards.

    Free Quote

    Competitive Parker Chomerics CHO-FOIL CCE Shielding Tape prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Parker Chomerics CHO-FOIL CCE Shielding Tape is a copper-foil EMI shielding material supplied with an electrically conductive pressure-sensitive acrylic adhesive. The construction is intended for enclosure seam shielding, cable shield termination, and low-impedance grounding without soldered or mechanical fasteners. The product is identified by the designation CHO-FOIL CCE and is commonly slit from roll stock to application-specific widths. A dead-soft copper carrier is combined with a conductive acrylic PSA that forms a Z-axis electrical path across the adhesive bond line. Because installed shielding performance is controlled by seam contact resistance, overlap geometry, and substrate surface condition rather than by the foil carrier alone, release-to-production decisions should be based on supplier lot data for the specific tape width, substrate, and surface finish. The tape is applied in compliance-oriented electronics, including medical enclosures, instrumentation, and telecommunication modules, where conductive coatings or gasket attachment may be mechanically limited. The standard carrier thickness is commonly supplied at 0.1016 mm (0.004 in), with custom slit widths and die-cut configurations available from the manufacturer.

    How does the conductive pressure-sensitive adhesive establish a low-resistance interface on enclosure substrates?

    The adhesive layer is an acrylate-based viscoelastic system filled with conductive particles. Its Z-axis conductivity develops only when the PSA wets the substrate and establishes sufficient particle-to-substrate contacts. Painted enclosures, anodized aluminum, and low-surface-energy polymers such as polypropylene or acetal may not provide a reliable low-resistance interface without additional surface treatment. A solvent wipe with 70% isopropanol or a manufacturer-approved cleaner is normally required before application. Peel adhesion is evaluated according to ASTM D3330/D3330M-04, but conductive PSA values are not directly equivalent to nonconductive PSA values because filler loading alters viscoelastic flow and bond formation. On automated taping stations, edge lifting and micro-delamination are most likely where the tape crosses a sharp corner or where liner removal occurs before adhesive wet-out. A roller with a contact width equal to or greater than the tape width is used to apply pressure; visual flatness alone does not confirm a low-resistance interface. Peel force at the leading and trailing edges of the strip should be monitored because these zones often show lower pressure and higher variability than the center.

    Shielding effectiveness is not an intrinsic tape property in isolation. When measured in accordance with IEEE 299-2006 or the legacy MIL-STD-285 method, the result applies to a specific fixture configuration, aperture size, edge termination, and frequency range. A copper-foil barrier can provide high plane-wave attenuation in a fully terminated test fixture; however, a PSA seam applied to a painted or passivated enclosure may leak along the adhesive-substrate interface long before the foil carrier becomes the limiting factor. The correct qualification approach is to measure the installed seam or closure in the intended housing with a fixture that replicates the enclosure joint and gasket-free PSA termination. Supplier-published data for CHO-FOIL CCE should be requested for the intended frequency range; where the exact enclosure configuration has not been evaluated, published data for that specific installed configuration is limited.

    Surface Preparation Sequences and Peel Adhesion Boundaries

    Adhesion performance of the acrylic PSA is highest when the substrate is clean, dry, and free of mold-release agents, silicone oils, and oxidized plasticizers. A production line cleaning sequence should include a dry wipe, a solvent wipe with 70% isopropanol or a manufacturer-approved cleaner, and a final dry cloth pass. Low-surface-energy polymers such as polypropylene, acetal, and thermoplastic olefins do not wet adequately with acrylic PSA and may require corona, plasma, or adhesion promoter treatment before tape application. Painted surfaces bond to the coating, not the polymer beneath; adhesion is therefore limited by the coating’s own adhesion to the substrate. On flame-retardant polycarbonate/ABS blends, mold-release additives can inhibit adhesion and should be removed before lamination. Reworked parts should not receive a second layer over a contaminated first layer; the original tape should be removed and the surface re-cleaned.

    Differences from other shielding tapes are evident in both electrical and mechanical behavior. A copper foil tape with nonconductive adhesive requires an exposed foil surface or a mechanical fastener to create a grounding path; CHO-FOIL CCE avoids this because the PSA itself is conductive. Compared with conductive fabric tapes, the copper carrier produces a higher plane-wave attenuation per unit thickness but has lower conformability around compound curves and repeated flexures. Fabric tapes are therefore specified for hinged or irregular surfaces, while CCE is selected for seam sealing, flat grounding pads, and cable wrap where a metal barrier is required. Aluminum foil tapes may be lower in cost, but aluminum forms a nonconductive oxide and may create galvanic couples when applied to copper or steel surfaces in humid environments. Bulk conductivity values illustrate the carrier difference: copper is approximately 5.8 × 10⁷ S/m, whereas aluminum is approximately 3.5 × 10⁷ S/m. Despite this difference, installed shielding level is not governed by carrier conductivity alone; seam termination and adhesive contact resistance frequently dominate.

    Comparative characteristics of shielding tape alternatives
    AttributeCHO-FOIL CCEConductive fabric tapeAluminum foil tape
    Carrier materialCopper foilMetalized or plated fabricAluminum foil
    Adhesive typeConductive acrylic PSAConductive acrylic PSANonconductive acrylic PSA
    Through-adhesive groundingYesYesNo
    Conformability to compound curvesModerateHighModerate
    Oxidation behaviorCopper tarnish unless coated or platedCorrosion-resistant fiber or metal coatingNonconductive aluminum oxide forms readily
    Typical applicationSeam shielding, cable wrap, grounding padsHinges, irregular surfaces, flexuresGeneral-purpose utility shielding

    On automated production lines, tape placement is often followed by a post-lamination resistance check. A four-wire DC measurement is made across the applied seam with a milliohm meter; the acceptance limit is set from the enclosure shielding requirement rather than from the tape manufacturer’s generic surface resistivity. Because the conductive PSA path is lower in cross-sectional conductivity than the copper carrier, the measured resistance may be dominated by the adhesive interface. If the value exceeds the limit, the corrective action should distinguish between poor adhesive wet-out, contamination, insufficient pressure, and dimensional mismatch of the tape width to the seam. Electrostatic discharge control for the production area is referenced in IEC 61340-5-1, and conductive packaging should be used for converted parts where static-sensitive devices are handled nearby.

    When process conditions include elevated humidity, thermal cycling, or painted seams

    Acrylic PSA systems in this class are typically evaluated for continuous service below 85°C, with short-term excursions above that value requiring review of the supplier’s thermal aging data. Sustained humidity above 85% RH can reduce peel strength and promote corrosion at the exposed copper foil edge. If the enclosure is subjected to thermal cycling, differential expansion between copper and polymer substrates may create shear stress at the adhesive interface; this is more severe on large flat panels than on small die-cut parts. In marine or salt-fog environments, exposed copper edges require corrosion qualification; a tin- or nickel-plated foil or edge encapsulation may be required. The user should request ASTM D3654/D3654M-06 accelerated aging data and ASTM B117 salt spray data if the application involves outdoor exposure or condensation. CHO-FOIL CCE is not a structural adhesive, is not intended for continuous immersion, and should not be used as a sole mechanical fastener.

    Where a pressure-sensitive adhesive tape is accepted as a Recognized Component, the supplier usually references UL 510 for flame and insulation properties. A current UL file should be requested during design review; recognition is not universally valid for all thicknesses and widths. The product family is generally declared according to RoHS 2011/65/EU, Annex II, and Regulation (EC) No 1907/2006 for REACH SVHC communication, but the user must verify current supplier certificates before production release.

    Compliance and test documentation matrix
    RequirementReferenceTypical evidence
    Restriction of hazardous substancesRoHS 2011/65/EU, Annex IISupplier declaration of conformity
    REACH SVHC communicationRegulation (EC) No 1907/2006, Article 33Supplier REACH statement
    Surface and volume resistivityASTM D257-14Laboratory test report
    Shielding effectivenessIEEE 299-2006 / legacy MIL-STD-285EMC laboratory report with fixture details
    Peel adhesionASTM D3330/D3330M-04Lot test data

    Die-cut CHO-FOIL CCE parts are often supplied on kiss-cut liners or as multi-part arrays for high-volume placement. The release liner configuration and die-cut geometry influence peel-off force during automated pick-and-place. If the liner is too tightly cut, adhesive transfer may occur; if the liner is too loose, parts can shift in the shipping package. Incoming inspection should verify that the liner releases cleanly and that the conductive adhesive remains intact on the foil. A part with exposed liner adhesive or damaged copper edge should be rejected before placement because seam continuity may be compromised. For portable diagnostic devices and other small enclosures, the tape is typically converted into pad shapes that cover exposed seams and overlapped edges; the part must not be allowed to bridge isolated circuit nodes unless intentional grounding is designed.

    Top