Products

Parker Chomerics CHO-FOIL CCD Shielding Tape

    • Product Name: Parker Chomerics CHO-FOIL CCD Shielding Tape
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 388495
    Manufacturer Parker Chomerics
    Product Name CHO-FOIL CCD Shielding Tape
    Product Type Double-sided conductive copper foil tape
    Backing Material Copper foil
    Adhesive Type Conductive acrylic pressure-sensitive adhesive
    Adhesive Configuration Double-sided
    Color Copper
    Total Thickness 0.0045 in (0.114 mm)
    Surface Resistance 0.05 ohms/square or less
    Electrical Conductivity Electrically conductive
    Shielding Effectiveness >100 dB from 30 MHz to 1 GHz
    Operating Temperature Range -40°C to 121°C (-40°F to 250°F)
    Flammability Rating UL 94 V-0
    Rohs Compliance RoHS compliant
    Shelf Life 12 months from date of manufacture
    Standard Roll Length 18 yd (16.5 m)

    As an accredited Parker Chomerics CHO-FOIL CCD Shielding Tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Parker Chomerics CHO-FOIL CCD Shielding Tape is supplied as one roll per package, sealed in protective plastic and labeled.
    Container Loading (20′ FCL) Full 20-foot FCL container loading of palletized Parker Chomerics CHO-FOIL CCD Shielding Tape, securely stowed in original packaging for transport.
    Shipping Parker Chomerics CHO-FOIL CCD Shielding Tape is not regulated for transport by DOT/IATA/IMDG. Ship as non-hazardous goods in original, sealed packaging. Protect from moisture, puncture, and extreme temperatures. No UN number, hazard class, packing group, or marine pollutant applies. Follow carrier and regional requirements.
    Storage Store Parker Chomerics CHO-FOIL CCD Shielding Tape in its original sealed packaging in a cool, dry, well-ventilated area. Keep away from direct sunlight, heat, sparks, flames, and moisture. Recommended conditions are 10–30°C with low humidity. Do not stack heavy items on the rolls, and protect the conductive adhesive from contamination. Observe shelf-life guidance and rotate stock. Use within the supplier-recommended period after opening.
    Shelf Life Shelf life is 12 months from date of manufacture when stored in original packaging at 21°C and 50% relative humidity.
    Application of Parker Chomerics CHO-FOIL CCD Shielding Tape

    Contact Resistance Across Seamed Enclosure Joins Rarely Stays Below 10 mΩ After 500 Thermal Cycles

    Die-cast aluminum enclosure seams on outdoor 5G remote radio units require a continuous conductive bridge between mating flanges to prevent shielding effectiveness collapse below 100 MHz. CHO-FOIL CCD die-cut into flange-shaped gaskets supplies a double-sided conductive acrylic adhesive layer that bonds both flange faces while the copper foil carrier spans the mechanical seam. The copper foil exhibits a volume resistivity of 1.7 × 10⁻⁸ Ω·m at 20 °C. The conductive acrylic adhesive contributes a surface resistivity below 0.05 Ω/sq when measured per ASTM D257. Fastener torque values between 0.8 N·m and 1.2 N·m on M3 stainless steel hardware generate sufficient compressive stress to collapse the adhesive layer. Collapse of the adhesive layer establishes direct metal-to-metal contact between the copper foil and the aluminum flange surface. Contact resistance measured with a four-wire micro-ohmmeter typically reads below 5 mΩ on freshly assembled joints. Thermal cycling per Telcordia GR-1089-CORE Section 5.2 from -40 °C to +85 °C introduces differential thermal expansion between CTE values of 17 ppm/K for copper and 23 ppm/K for aluminum. After 500 cycles, contact resistance on a subset of joints exceeds 50 mΩ due to adhesive creep and aluminum oxide re-formation at the interface. The adhesive layer does not exhibit debonding failure at these excursions; the resistance increase originates at the metal-to-metal microcontact interface where oxide re-growth interrupts conduction. Field teardown data indicates that seam shielding effectiveness below 100 MHz degrades measurably once contact resistance exceeds 50 mΩ because reflection loss at the seam becomes the dominant leakage mechanism. Die-cut dimensional tolerances of ±0.13 mm are required to maintain gasket registration within the flange groove. The terminal assembly is a seam-sealed RRU enclosure conforming to GR-1089-CORE EMC requirements and RoHS 2011/65/EU substance restrictions.

    On high-density interconnect PCBs within handheld computing devices, ground loop impedance between shield cans and the main chassis must remain below 0.1 Ω to prevent radiated emissions from high-speed differential pairs operating above 5 Gb/s. CHO-FOIL CCD is supplied in roll form for automated die-cutting into rectangular islands sized to bridge the gap between PCB copper pour regions and stamped metal shield frames. The double-sided conductive adhesive bonds the shield frame to the PCB surface while providing z-axis conductivity through the adhesive thickness. Placement is performed with vacuum pick-and-place equipment operating at a cycle time of 1.2 s per part. Lamination pressure of 2.5 N/cm² applied by a silicone roller for 3 s is sufficient to achieve wet-out on solder mask and tin-plated copper surfaces. Peel adhesion to tin-plated copper per ASTM D3330/D3330M reaches 3.5 N/cm after 24 h dwell at 23 °C. The adhesive formulation is acrylic-based and does not require thermal cure; full bond strength develops through ambient crosslinking of the pressure-sensitive polymer network. No outgassing above 0.1% total mass loss is observed when tested per ASTM E595. Electrical continuity through the tape is verified per ANSI/ESD S20.20 with a resistance limit of 1 Ω between the shield frame and chassis ground. The terminal assembly is a fully shielded smartphone mainboard that meets IEC 61000-4-2 ESD immunity at ±8 kV contact discharge.

    What Surface Energy Threshold Governs Adhesive Wet-Out on Nickel-Plated Aluminum Backshells?

    Nickel-plated aluminum connector backshells in shielded avionics cable harnesses require a conductive bond between the cable shield braid and the connector body. CHO-FOIL CCD is wrapped around the exposed shield braid and pressed against the inner wall of the backshell. The adhesive wet-out on nickel-plated surfaces depends directly on substrate surface energy. A surface energy of 38 mN/m or higher is required for adequate wet-out of the conductive acrylic adhesive. Surfaces below this threshold cause adhesive dewetting, void formation, and elevated contact resistance at the bond line. Surface preparation begins with solvent wiping using 99.9% isopropyl alcohol. Dyne pen testing at 38 mN/m per ASTM D2578 confirms the prepared surface. Substrates with surface energy below 38 mN/m are treated with atmospheric plasma at a power density of 20 W/cm² and a standoff distance of 5 mm. Plasma treatment raises surface energy to 52–58 mN/m by removing hydrocarbon contamination and generating polar functional groups on the nickel oxide surface. Application of the tape is performed at a wrap overlap of 50% minimum to prevent leakage at the seam line. A compression sleeve is then installed over the wrapped region. The sleeve applies radial compression of approximately 3 N/cm² during installation. Full adhesive bond strength develops over 24–72 h at 23 °C. Peel adhesion to nickel-plated aluminum after 72 h dwell reaches 2.8 N/cm per ASTM D3330/D3330M. Operating temperature range from -55 °C to +125 °C per RTCA DO-160 Section 5 is satisfied without adhesive degradation or delamination. Shielding effectiveness of the wrapped region exceeds 80 dB from 30 MHz to 10 GHz when measured per ASTM D4935-18. The terminal assembly is an ARINC 429 data bus cable harness conforming to SAE AS85049 connector accessory requirements and MIL-STD-461 radiated emission limits.

    Frequency BandTypical Shielding Effectiveness for Copper Foil TapeTest Method
    30 MHz>80 dBASTM D4935-18
    100 MHz>80 dBASTM D4935-18
    1 GHz>85 dBASTM D4935-18
    10 GHz>80 dBASTM D4935-18

    Within LCD module assemblies used in automotive infotainment displays, display driver ICs radiate broadband emissions from 30 MHz to 1 GHz that couple onto the module chassis unless a low-impedance ground path is established along the perimeter. CHO-FOIL CCD is converted into continuous strips of 2 mm width. The strips are laminated between the glass substrate edge and the die-cast magnesium frame. The double-sided conductive adhesive bonds the ITO ground trace on the glass to the frame surface without requiring mechanical spring contacts. Die-cut strip length tolerance is held to ±0.1 mm. Placement is performed with automated laminating equipment applying 2.0 N/cm² pressure at 10 mm/s traverse speed. The lamination step is followed by a dwell period of 15 min before module assembly proceeds. The adhesive system must withstand exposure to 85 °C and 85% relative humidity for 1,000 h without delamination or resistance increase beyond 0.5 Ω. Copper corrosion at the copper-ITO interface is suppressed by the acrylic adhesive barrier layer, which isolates the copper from direct atmospheric moisture ingress. Testing per IEC 61000-4-2 at ±15 kV air discharge verifies that the module frame does not accumulate charge. The terminal assembly is an automotive infotainment display module meeting OEM electromagnetic compatibility specifications.

    When Double-Sided Copper Foil Replaces Fabric-Over-Foam in Sealed BMS Enclosures

    Sealed battery management system enclosures in electric vehicle battery packs require EMI shielding across removable cover seams while maintaining environmental sealing against dust and water ingress. Fabric-over-foam gaskets provide a compression-based shielding path but introduce compression set and relaxation over the vehicle service life. Replacing the gasket with die-cut CHO-FOIL CCD gaskets eliminates compression set failure modes. The double-sided conductive adhesive bonds the aluminum cover to the machined enclosure lip while the copper foil maintains electrical continuity. Cover fasteners are torqued to 2.5 N·m on M4 hardware. The adhesive layer conforms to surface roughness up to Ra 3.2 µm on the machined lip. Environmental sealing is maintained by a separate elastomeric O-ring seated in a groove outside the shielding gasket path. The shielding gasket is not exposed to battery electrolyte. Operational temperature range from -40 °C to +85 °C per ISO 6469-1 is satisfied without adhesive embrittlement. Shielding effectiveness above 80 dB from 100 MHz to 10 GHz is maintained. The adhesive bond prevents relative motion between the cover and enclosure during random vibration testing per ISO 16750-3. The terminal assembly is a sealed BMS enclosure conforming to ISO 6469 and UN ECE R100 electrical safety requirements.

    Biocompatibility Screening of Conductive Acrylic Adhesive in Non-Contact Housings

    Achieving IEC 60601-1-2 compliance in diagnostic ultrasound console housings requires internal seam shielding that does not introduce patient-contact risk. CHO-FOIL CCD is applied as an internal seam shield on plastic housing panels. The tape is positioned such that no direct patient or operator skin contact occurs during normal use. The conductive acrylic adhesive is a pressure-sensitive formulation and does not require solvent evaporation or thermal cure. Die-cut strips are applied to interior seams with 2.0 N/cm² lamination pressure. Adhesion to flame-rated ABS and polycarbonate substrates per ASTM D3330/D3330M reaches 2.5 N/cm after 72 h dwell. The adhesive bond resists peel forces at service temperatures up to 50 °C inside the console enclosure. Biocompatibility per ISO 10993-1 is not inherent to the product. The device manufacturer remains responsible for biocompatibility evaluation of the complete finished medical device. Published data for this specific configuration is limited. The terminal assembly is a mechanically assembled plastic housing that meets IEC 60601-1-2 radiated and conducted emission limits in a Class A environment.

    Compliance RequirementApplicable StandardScope
    Restricted substancesRoHS 2011/65/EULead, mercury, cadmium, hexavalent chromium, PBB, PBDE
    SVHC declarationREACH 1907/2006Substances of very high concern above 0.1% w/w
    Surface resistivityASTM D257Adhesive surface conductivity verification
    Peel adhesionASTM D3330/D3330M90° peel from standard substrates
    Shielding effectivenessASTM D4935-18Plane wave shielding from 30 MHz to 1.5 GHz
    Airborne equipment environmentalRTCA DO-160Temperature, vibration, humidity for avionics
    Telecom EMCTelcordia GR-1089-COREElectromagnetic compatibility in network equipment
    Electric vehicle safetyISO 6469-1Electrical safety of battery packs

    At 13.56 MHz, NFC antenna assemblies use a ground plane reflector to constrain the read field and increase coupling efficiency. CHO-FOIL CCD applied to the rear surface of ceramic or FR4 antenna substrates provides a conductive backplane without requiring solder reflow. The double-sided adhesive bonds the copper foil to the antenna substrate while the exposed adhesive side mounts directly to the device housing. The copper foil thickness of 0.035 mm exceeds the RF skin depth at 13.56 MHz, ensuring complete reflection of the magnetic field. Published data for this specific configuration is limited.

    Free Quote

    Competitive Parker Chomerics CHO-FOIL CCD Shielding Tape prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Parker Chomerics CHO-FOIL CCD Shielding Tape is a copper-foil-backed pressure-sensitive adhesive tape in which the adhesive layer is a conductive acrylic formulation. The product is specified for electromagnetic interference shielding, electrical grounding, and electrostatic charge control in cabinet, enclosure, and module applications where a thin conformable conductor must bridge mating metal surfaces. The designation CCD identifies a particular foil–adhesive–liner construction within the wider CHO-FOIL family; the exact foil thickness, adhesive thickness, total tape thickness, roll width, and roll length are controlled by the current Parker Chomerics datasheet and may differ among regional distribution formats. The copper foil is supplied in rolled or electrodeposited form, and the conductive acrylic adhesive is applied to one side of the foil. A release liner is removed before laydown.

    Because the adhesive is electrically conductive, the tape does not rely solely on edge contact or mechanical fasteners to create a bond-line ground path. The foil itself provides high bulk conductivity, while the adhesive provides through-thickness conduction. The conductive filler network inside the acrylic matrix reduces the joint resistance between the copper backing and the substrate after pressure application. The result is a shielding tape that can be applied across seams, access panels, connector flanges, and enclosure slots. It is not an environmental seal, and it does not provide structural load-carrying capability.

    For purchasing and incoming inspection, the critical parameters include tape width tolerance, roll length, total thickness, surface resistance, through-adhesive resistance, peel adhesion to stainless steel or aluminum, and shielding effectiveness. These properties are not specified by a single universal standard; the supplier may use internal test methods traceable to ASTM D4496, ASTM D3330, and UL 510. Buyers should request the certificate of conformance for each lot.

    What makes the conductive acrylic adhesive in CHO-FOIL CCD materially different from a nonconductive adhesive layer?

    A nonconductive pressure-sensitive adhesive between copper foil and an aluminum or steel substrate acts as a dielectric spacer. The direct-current resistance between backing and substrate remains high until mechanical pressure punctures the adhesive or until the foil is folded around a bare ground point. In an enclosure seam, that creates a discontinuous ground plane and poor low-frequency shielding. CHO-FOIL CCD uses a percolating conductive filler network inside the acrylic layer. After roller pressure, the adhesive forms a large number of distributed conductive contacts. Published supplier data for conductive acrylic pressure-sensitive adhesive foil tapes commonly report through-adhesive resistance below 1 Ω using a 1 cm² electrode at a defined contact pressure; exact CHO-FOIL CCD values should be confirmed against the current revision because filler type, coating weight, and surface roughness alter the result. The remaining resistance is not zero. For a 25 mm wide tape joint, the total seam resistance includes foil sheet resistance, bond-line resistance, and substrate interface resistance.

    Above 100 MHz, capacitive coupling across a thin nonconductive adhesive may mask the deficiency in some test setups, but below 10 MHz the absence of a conductive path becomes measurable as higher transfer impedance. The conductive adhesive in CHO-FOIL CCD therefore changes the low-frequency failure mode from an open adhesive layer to a finite contact resistance that can be modeled as a series resistance in a ground path.

    Shielding effectiveness of copper foil with conductive adhesive depends on frequency, seam geometry, and termination quality. Copper skin depth at 1 MHz is approximately 0.066 mm, and at 10 MHz it is approximately 0.021 mm. A foil thickness of 0.035 mm is therefore electrically thin at 1 MHz but exceeds the skin depth at higher frequencies. In the 30 MHz–10 GHz band, a continuous copper foil tape applied over a compressed seam can provide shielding effectiveness above 60 dB when tested in a controlled fixture. Published data for this specific configuration may vary because test aperture size, substrate material, seam overlap width, and contact pressure all influence the result. If the application requires a certified attenuation value, enclosure-level testing under MIL-STD-461 or IEEE 299 should be performed rather than relying on material-level shielding data.

    When enclosure seams require RF shielding without increased fastener density

    Enclosure seams that are held by fasteners on 50 mm to 75 mm centers can radiate through the gaps between fasteners. The tape is applied across the seam before final assembly to extend the conductive contact length between fasteners and to cover gaps created by sheet-metal tolerance variation. The tape should be oriented so that the copper foil is not stretched, cut to provide at least 3 mm of contact on each side of the seam, and pressed with a 60 Shore A roller or a pneumatic nip at 0.3 MPa to 0.5 MPa. Application below 10 °C reduces tack and may produce incomplete wet-out, especially on textured or oily surfaces. Full adhesive bond strength typically develops over 24 h to 72 h at ambient temperature, although conductive performance appears immediately after pressure is applied. If the tape is applied over a painted surface, the conductive adhesive contacts the paint film, not the base metal; the paint must be removed or masked locally where electrical contact is required.

    With automatic tape placement equipment, the roll tension should be kept low enough to avoid yielding the copper foil. Once yielded, the foil may retain curl and peel back from the substrate after thermal cycling. Production lines that laminate conductive foil to flat panel seams with a heated roller should verify that the heat does not accelerate acrylic adhesive flow or create adhesive starvation at the tape edge. For die-cut parts, a kiss-cut operation can cut the foil and adhesive without cutting the liner; grounding of the converting equipment is required to prevent static charge accumulation on the liner.

    Surface preparation, galvanic corrosion, and application temperature constraints

    Surface cleanliness controls bond-line resistance. Isopropyl alcohol wiping followed by solvent drying removes common oils and light ionic contamination. Abrasive treatment may roughen the surface and improve mechanical keying, but it can also remove conversion coatings that provide galvanic protection. Copper is cathodic to aluminum and magnesium; in the presence of moisture and ionic contamination, the tape edge can act as a galvanic cathode and accelerate substrate corrosion. For aluminum enclosures qualified to ASTM B117 salt spray, chromate or non-chromate conversion coating under the tape may help reduce corrosion, but the conductive bond must still be made to bare or conversion-coated metal, not to paint or anodize. Magnesium substrates present a more severe galvanic mismatch. If the design must survive prolonged salt fog or condensing humidity, a tin-plated copper variant or an isolating conductive gasket may be more appropriate. Published data for this specific configuration is limited when the tape is applied to magnesium, so qualification testing is required.

    The acrylic adhesive is stable over a typical operating range but should not be exposed to ketones, esters, or chlorinated solvents in service. Such solvents can swell the adhesive and reduce peel strength. The copper foil can oxidize over time, particularly at elevated humidity. Oxidation of the outer foil surface does not normally eliminate shielding because copper oxides are thin and the bulk conductor remains, but oxidation at the bond line may increase contact resistance if the adhesive loses contact. Storing rolls in sealed polyethylene bags with desiccant at 20 °C to 25 °C and 45–55% RH preserves tack and minimizes oxidation.

    Chomerics CHO-FOIL CCD is frequently compared with aluminum foil tape, nonconductive adhesive copper tape, and conductive fabric tape. The following material-class comparison uses published vendor data for typical values; each value should be verified for the specific production lot.

    Material classBulk backing conductivityAdhesive pathShielding behaviorPrimary application boundary
    CHO-FOIL CCD class: copper foil with conductive acrylic pressure-sensitive adhesivecopper, approximately 5.8 × 106 S/mconductive pressure-sensitive adhesive; through-adhesive resistance typically below 1 Ωhigh reflection plus absorption in 30 MHz–10 GHz; low direct-current seam resistancegalvanic mismatch with aluminum and magnesium; limited conformability on tight bends
    Copper foil with nonconductive acrylic adhesivecopper, approximately 5.8 × 106 S/minsulating bond line until punctured or edge-clampedhigh backing shielding but unreliable seam conduction without fastenersrequires mechanical grounding or selective conductive gaskets
    Aluminum foil with conductive pressure-sensitive adhesivealuminum, approximately 3.5 × 106 S/mconductive pressure-sensitive adhesive similar to copper foil versionsgood high-frequency shielding but lower bulk conductivity; surface oxide may increase contact resistanceless galvanic risk with aluminum substrates; not ideal for solderable joints
    Metallized fabric with conductive pressure-sensitive adhesivelower sheet conductance than foilconductive pressure-sensitive adhesive, often higher contact resistancedrapable and suitable for cable wrap; reduced low-frequency shielding below 100 MHznot suitable for seams requiring very low direct-current resistance or repeated flexure with high contact stability

    Compared with conductive fabric tapes, CHO-FOIL CCD provides lower sheet resistance and better low-frequency shielding but less conformability. Compared with aluminum foil conductive tape, the copper backing offers higher bulk conductivity and solderability, but the copper-tape edge creates a stronger galvanic cell against aluminum or magnesium. Compared with nonconductive-adhesive copper tape, the conductive adhesive eliminates the requirement for the adhesive to be punctured by pressure or for a separate grounding strap to bridge every seam segment. However, the conductive adhesive is not a replacement for a continuous weld or for a conductive elastomer gasket used in environmental sealing. If soldering is required, the adhesive and liner should be removed from the solder joint area because acrylic decomposes at soldering temperatures and may contaminate the joint.

    Electrical bonding safety should be analyzed separately from electromagnetic interference shielding. The thin copper foil and conductive adhesive provide a low-impedance path for small signal and ground-reference currents, but they are not dimensioned for protective earth fault currents. End-product standards such as IEC 62368-1 and IEC 61010-1 require protective bonding conductors to survive specified fault conditions and to maintain a maximum resistance between exposed parts and the protective earth terminal. CHO-FOIL CCD may contribute to grounding at the circuit level, but it does not replace a designated protective conductor unless the complete assembly is evaluated and found compliant under the relevant safety standard.

    Batch-to-batch variance in conductive adhesive tapes is primarily observed in peel strength and through-adhesive resistance, not in bulk copper conductivity. Incoming inspection should sample roll width, total thickness, and surface resistance. A four-point probe setup with spring-loaded pins is used for sheet resistance; if pin pressure is too low or the adhesive creates an insulating film on the probe face, readings may be unstable. Peel adhesion to a standard stainless steel panel should be measured after 20 min dwell and again after 24 h to confirm that adhesive wet-out is progressing. For critical applications, retain a control sample from each batch and record application temperature, humidity, roller pressure, and substrate roughness to support traceability.

    The tape’s limiting application boundaries include sharp bends, continuous movement, direct liquid immersion, and long-term contact with incompatible plasticizers. When applied to flexible circuits or moving shields, copper foil may fracture after repeated cycles because the metal work-hardens. For static seams, epoxy or acrylic coating can be applied over the tape edge to reduce solvent intrusion and edge lift, but the coating should not contaminate the bond line. If a design requires continuous operation above 105 °C, the adhesive may soften and lose peel strength; the current datasheet should be checked for the maximum continuous service temperature and any UL thermal index.

    Top