| HS Code | 386186 |
| Manufacturer | Nan Ya Plastics Corporation |
| Product Name | PBT-FR 1403G6 GNC6 |
| Polymer Base | Polybutylene terephthalate (PBT) |
| Reinforcement | 30% glass fiber |
| Flame Retardancy | Yes |
| Ul94 Rating | V-0 |
| Density | 1.53 g/cm3 |
| Tensile Strength | 120 MPa |
| Flexural Modulus | 8000 MPa |
| Elongation At Break | 2.5% |
| Notched Izod Impact Strength | 8 kJ/m2 |
| Heat Deflection Temperature At 1 82 Mpa | 200 °C |
| Melting Point | 225 °C |
| Molding Shrinkage | 0.2-0.5% |
| Water Absorption | 0.03% |
| Processing Method | Injection molding |
As an accredited Nan Ya PBT-FR 1403G6 GNC6 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Nan Ya PBT-FR 1403G6 GNC6 is packaged in 25 kg moisture-proof bags, palletized for safe bulk shipment and storage. |
| Container Loading (20′ FCL) | Nan Ya PBT-FR 1403G6 GNC6 packaged and loaded into a 20-foot FCL container for ocean shipment. |
| Shipping | Nan Ya PBT-FR 1403G6 GNC6 is shipped as flame-retardant, glass-fiber-reinforced PBT resin pellets in sealed moisture-barrier bags and cartons/boxes. It is normally non-hazardous for transport (no UN number), requiring dry conditions, moderate temperature, intact packaging, and protection from direct sunlight and contamination. |
| Storage | Store Nan Ya PBT-FR 1403G6 GNC6 in a cool, dry, well-ventilated area away from direct sunlight, heat, ignition sources, and moisture. Keep in original, tightly sealed packaging and protect from dust and static. Segregate from strong oxidizers, acids, and bases. Use grounded containers and avoid prolonged exposure to humid air. Follow the manufacturer’s SDS and local regulations. |
| Shelf Life | Shelf life is 12 months from manufacture when stored sealed in a dry, cool place, protected from moisture and direct sunlight. |
Competitive Nan Ya PBT-FR 1403G6 GNC6 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Nan Ya PBT-FR 1403G6 GNC6 is a 30% glass-fibre-reinforced, flame-retardant polybutylene terephthalate injection moulding compound. The 1403 series identifies the flame-retardant PBT base; GNC6 designates the glass-reinforced natural-colour variant of the 1403G6 series. The grade is supplied as natural-colour pellets for thin-wall electrical and electronic components requiring UL 94 V-0 performance at a minimum wall thickness of 0.8 mm. Before melt processing, the material should be pre-dried to a final moisture content below 0.02% by weight, determined according to ISO 15512:2019. The glass-fibre content is 30% by weight; at a composite density of approximately 1.63 g/cm³ this corresponds to roughly 18% by volume. Where published data for this specific GNC6 natural-colour configuration is limited, the supplier lot certificate and the UL yellow card should be treated as governing documents for tool design and compliance.
The resin matrix is semi-crystalline. Glass-fibre reinforcement changes unfilled flame-retardant PBT from a relatively flexible, high-flow material into a high-modulus compound with strong anisotropic shrinkage. In practice, tensile and flexural stiffness increase by approximately three times relative to unfilled flame-retardant PBT, while tensile elongation at break drops below 5% and weld-line strength becomes the limiting mechanical property in multi-gated components.
For design calculations, the values in Table 1 represent the general published envelope for 30% glass-fibre, flame-retardant PBT grades of the 1403G6 type. They are not lot-specific certification limits. Test specimens are dry-as-moulded and tested at 23°C and 50% relative humidity unless otherwise stated.
| Property | Test method | Unit | Typical value / range |
|---|---|---|---|
| Density | ISO 1183-1 | g/cm³ | 1.63 |
| Water absorption, 24 h at 23°C | ISO 62 | % | 0.05 |
| Mould shrinkage, flow direction | ISO 294-4 | % | 0.2–0.5 |
| Tensile stress at break | ISO 527-2 | MPa | 110 |
| Tensile elongation at break | ISO 527-2 | % | 2.0 |
| Flexural strength | ISO 178 | MPa | 170 |
| Flexural modulus | ISO 178 | MPa | 9,000 |
| Notched Izod impact, 23°C | ISO 180/A | kJ/m² | 7 |
| Heat deflection temperature, 1.80 MPa | ISO 75-2/Af | °C | 205 |
| Flame classification | UL 94 | class | V-0 at 0.8 mm |
| Comparative tracking index | IEC 60112 | V | 250 |
The tabulated values are class-typical 30% glass-fibre flame-retardant PBT data from the Nan Ya 1403G6 product group and should be verified against the lot certificate. Mechanical figures are unlikely to be reproduced on moulded parts with severe fibre orientation or on parts with multiple weld lines unless gate position and flow-channel design are optimised. Regulatory declarations for RoHS Directive 2011/65/EU Annex II as amended by (EU) 2015/863 and REACH Regulation (EC) No 1907/2006 Article 33 SVHC disclosure should be requested from the supplier and maintained under the user’s quality system.
Hydrolytic degradation is the primary processing failure mode in glass-reinforced flame-retardant PBT. Moisture above 0.02% by weight attacks the ester linkage during barrel residence; observable effects include silver streaking, viscosity loss, reduced tensile elongation at break and altered UL 94 performance after ageing. A dehumidifying dryer set at 120°C for 4 h with a dew point below −30°C should be used. Hopper residence in high-humidity plants should not exceed 30 min unless the hopper is continuously dried. If the material remains in an open hopper at relative humidity above 60%, moisture regain can occur rapidly on pellet surfaces.
Melt temperature should be kept within 240°C to 270°C. Above 270°C, flame-retardant decomposition becomes significant, and acidic by-products may corrode uncoated tool steel. Rear, middle and nozzle zone settings should follow a rising profile of approximately 230°C–250°C, 240°C–260°C and 250°C–270°C. A general-purpose screw with an L/D ratio of 18:1 to 22:1 and compression ratio of 2.5:1 to 3.5:1 is suitable. Back pressure is typically 0.3 MPa–0.7 MPa, and screw speed is usually 60 min⁻¹–100 min⁻¹. Injection pressure varies with flow length and wall thickness but commonly falls between 80 MPa and 120 MPa for thin-wall connector housings.
Mould temperature should be maintained at 80°C to 100°C to crystallise the PBT matrix sufficiently. Lower mould temperatures reduce surface finish and heat distortion under load; higher temperatures can extend cycle time and complicate ejection. On production-scale equipment, clamp force is usually selected at 4 kN/cm²–6 kN/cm² of projected part area, although the final value depends on runner layout and filling pressure. A shut-off nozzle is preferred to reduce drool and moisture contact at the melt front.
Regrind from sprues and runners may be reused in closed-loop processing. The melt flow rate ratio should be checked according to ISO 1133-1:2022 at 250°C and 2.16 kg load when regrind exceeds 25% by weight. Higher regrind levels increase glass-fibre attrition and raise the risk of viscosity shift; they should not be introduced into parts subject to UL 94 end-product verification without supporting shot-to-shot viscosity data. Hot-runner manifolds should be externally heated and controlled so that no zone exceeds 270°C; thermocouple placement within 5°C of the set-point is required in high-cavitation tools. Mould vents at end-of-fill and weld lines should have land lengths of 0.01 mm–0.03 mm and sufficient channel depth to release moisture vapour and volatile degradation products. On production connector tools, failure to maintain dryer dew point and hot-runner temperature control produces mould plate-out on unplated cores and silver streaking before bulk mechanical properties show measurable loss.
In appliance connectors and relay bases, UL 94 V-0 classification alone does not guarantee insulation coordination. The comparative tracking index is measured according to IEC 60112 and determines material group classification for creepage-distance selection under IEC 60664-1. For halogenated 30% glass-fibre PBT of this class, a CTI of 250 V is commonly cited. Where the end product must satisfy glow-wire requirements, the moulded part should be tested to IEC 60695-2-11 and IEC 60695-2-13 at the final wall thickness and colour. Published data for this specific configuration is limited for glow-wire ignition temperature; therefore, end-product testing is required for unattended appliance applications.
Dimensional stability is improved by the glass-fibre network but is anisotropic. Flow-direction shrinkage is lower than cross-flow shrinkage, and a single gate at one end of a long connector body can produce bowing after ejection. Multiple gates, balanced runner layouts or melt-flow ratio checks can reduce cavity-to-cavity viscosity variation below ±3%. Weld lines created by multi-gate filling are the most common crack-initiation sites during thermal cycling because local fibre orientation becomes perpendicular to flow and load transfer across the weld plane is incomplete. The PBT matrix resists common aliphatic hydrocarbons and motor oils at moderate temperatures, but it is not recommended for long-term immersion in hot water above 80°C or strong alkaline solutions because ester hydrolysis accelerates. For outdoor enclosures, direct sunlight and condensation require UL 746C or equivalent end-product weathering evaluation; natural-colour PBT can embrittle under prolonged UV exposure. If colour concentrates are added, their carrier resins and flame-retardant interactions must be evaluated because some organic pigments reduce CTI or flame performance.
In existing tools dimensioned for unfilled flame-retardant PBT, substituting 1403G6 GNC6 changes mould shrinkage, flow length and gate pressure. A tool designed for 1.8%–2.2% flow-direction shrinkage may overpack or oversize when the 30% glass-fibre grade is used. The same steel may be modified by adjusting the feed system and packing pressure, but dimensional validation remains mandatory. Flow length is lower than that of unfilled FR-PBT; thin-wall sections below 0.4 mm may require high injection velocity and may develop fibre-rich surface layers that affect appearance and weld strength.
| Property | Unreinforced FR-PBT | 15% GF FR-PBT | 1403G6 GNC6 / 30% GF FR-PBT |
|---|---|---|---|
| Tensile modulus, ISO 527-2 | 2,600 MPa | 5,500 MPa | 9,000 MPa |
| Flexural modulus, ISO 178 | 2,500 MPa | 5,500 MPa | 9,000 MPa |
| Tensile strain at break, ISO 527-2 | 5.0% | 2.5% | 2.0% |
| Notched Izod impact, ISO 180/A | 4 kJ/m² | 6 kJ/m² | 7 kJ/m² |
| HDT at 1.80 MPa, ISO 75-2/Af | 60°C | 195°C | 205°C |
| Mould shrinkage, flow direction, ISO 294-4 | 1.8%–2.2% | 0.4%–0.8% | 0.2%–0.5% |
| Flame classification, UL 94 at 0.8 mm | V-0 | V-0 | V-0 |
The comparative values in Table 2 are class-typical public-datasheet ranges for halogenated FR-PBT grades, not lot-specific certificates. They illustrate the directional change in mechanical, thermal and shrinkage behaviour as glass-fibre content increases. Compared with 15% glass-fibre FR-PBT, the 30% grade offers higher flexural modulus and higher heat deflection under load but lower flow and increased anisotropy. Compared with PBT/PET blends, 1403G6 GNC6 typically retains a sharper crystallisation response; the difference can be observed by differential scanning calorimetry under ISO 11357-1:2016 in non-isothermal cooling. PBT/PC alloys can offer higher low-temperature impact but may require more aggressive drying and higher melt temperatures. Compared with polyamide 66 GF30 FR, the PBT grade absorbs much less moisture: water uptake over 24 h is approximately 0.05% under ISO 62, against typical polyamide values of 0.8%–1.0%. This does not make PBT suitable for hot-water immersion; it improves dimensional stability under humid air and condensation.
Component applications for 1403G6 GNC6 include multi-pin connectors, relay bases, terminal blocks, transformer bobbins, motor brush holders and small circuit-breaker internal parts. In each case, the part should be qualified at the minimum production wall thickness under the applicable end-product standard: UL 94 for flammability, IEC 60695-2-11 to IEC 60695-2-13 for glow-wire performance, IEC 60664-1 for creepage-distance selection based on the CTI value, and UL 746C where outdoor exposure or continuous condensation is present. If wall thickness below 0.4 mm is required, published data for this specific configuration is limited and mould-filling studies should be completed before tool manufacture. The material should be stored in sealed containers below 30°C and brought to room temperature before opening to reduce moisture regain on the pellet surface.