| HS Code | 526788 |
| Density | 1.54 g/cm³ |
| Glass Fiber Content | 15% |
| Flame Retardancy | UL94 V-0 |
| Tensile Strength | 105 MPa |
| Elongation At Break | 2.5% |
| Flexural Modulus | 6500 MPa |
| Charpy Notched Impact Strength | 5 kJ/m² |
| Heat Deflection Temperature At 1 82 Mpa | 200 °C |
| Molding Shrinkage | 0.4–0.8% |
| Water Absorption At 23 C 24 H | 0.08% |
| Dielectric Strength | 20 kV/mm |
| Volume Resistivity | 1×10^16 Ω·cm |
| Comparative Tracking Index | 600 V |
| Arc Resistance | 120 s |
As an accredited Mitsubishi Chemical Novaduran™ PBT+GF15% FR V-0 5010GN1-15 AM factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Supplied in 25 kg moisture-proof bags on pallets, each clearly labeled with product name, grade, lot number, and handling warnings. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): dry ambient loading of palletized 25 kg bags; approx. 18–20 MT net per 20′ container, subject to weight limits. |
| Shipping | Mitsubishi Chemical Novaduran™ PBT+GF15% FR V-0 5010GN1-15 AM is supplied as flame-retardant, 15% glass-fiber-reinforced PBT pellets. Ship in sealed, moisture-barrier packaging or lined containers under dry conditions. Protect from humidity, heat, direct sunlight, and contamination; handle and transport according to the SDS and local regulations. |
| Storage | Store Novaduran™ PBT+GF15% FR V-0 5010GN1-15 AM in a cool, dry, well-ventilated area away from direct sunlight, heat sources, and ignition. Keep containers tightly closed in original packaging to prevent moisture ingress and contamination. Avoid contact with strong oxidizers. Maintain good housekeeping to minimize dust; use appropriate PPE. Follow local regulations and SDS recommendations for handling and storage. |
| Shelf Life | Typical shelf life is 12 months in unopened original packaging, stored dry and below 30°C; verify with supplier. |
Competitive Mitsubishi Chemical Novaduran™ PBT+GF15% FR V-0 5010GN1-15 AM prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
The Mitsubishi Chemical Novaduran™ PBT+GF15% FR V-0 5010GN1-15 AM is a glass-fiber-reinforced polybutylene terephthalate compound with a nominal glass-fiber loading of 15% and a flame-retardant system that carries a UL 94 V-0 listing at the thickness specified in the current supplier Yellow Card. The material is positioned for injection-molded electrical and electronic housings, connectors, and switch components that require defined flame performance together with moderate tensile strength, reduced shrinkage, and lower warpage than higher-glass PBT grades. Full public datasheet values for this exact AM sub-grade are limited; quality-control certificates from the producer and the UL Yellow Card should control acceptance decisions. Representative property windows for the PBT+GF15 FR V-0 class include density near 1.55 g/cm³, tensile stress at break in the 85–95 MPa range under ISO 527-1/-2, and flexural modulus between 4,500 MPa and 5,500 MPa under ISO 178.
The glass-fiber content shifts the failure mechanism from ductile yielding to fiber-matrix debonding and brittle crack propagation. In comparison with an unfilled flame-retardant PBT, the 15% glass reinforcement raises flexural modulus by approximately 1.8–2.2×, increases heat deflection temperature under 1.8 MPa by roughly 100–125 °C, and reduces flow-direction mold shrinkage from 1.0–1.5% to 0.5–0.8% under ISO 294-4 conditions. These improvements are obtained at the expense of tensile strain at break, which falls from 5–10% to 1.5–2.5%, and increased tool abrasion. Relative to a 30% glass-fiber PBT, the 15% grade has lower melt viscosity and improved thin-wall filling; in spiral-flow testing, flow length typically increases by 10–20% at the same melt temperature and injection pressure. The lower glass content also reduces density from approximately 1.66 g/cm³ to 1.55 g/cm³ and narrows transverse shrinkage differentials, which is significant for flat connector bodies and multi-cavity tools where warpage is a rejection criterion. Weld-line strength remains a limiting factor: oriented glass fibers at knit lines can reduce tensile strength by 30–50% relative to bulk material, and gate placement must be designed to move knit lines away from snap-fit and insertion features.
Pre-drying in a desiccant dryer with a dew point of −40 °C or lower is required before melting. A typical drying condition for this material class is 120 °C for 4–6 h to reduce moisture below 0.02% as measured by Karl Fischer titration or an equivalent calibrated method. Residual moisture above this threshold at melt temperatures between 250 °C and 270 °C accelerates hydrolytic cleavage of the ester linkage, reducing intrinsic viscosity, tensile strength, and notched impact before visible splay or silver streaking appears on molded parts. Injection molding should use a screw with L/D 20:1–25:1 and compression ratio 2.0–2.5. Barrel settings from rear to nozzle may be 240 °C, 250 °C, 255 °C, and 260 °C, with a melt pyrometer reading of 250–270 °C. Mold temperature is typically 60–100 °C; the upper half of this range raises crystallization rate, improves dimensional stability after ejection, and reduces molded-in stress, but extends cycle time and can increase post-mold shrinkage. The flame-retardant package imposes a thermal boundary: at melt temperature above 280 °C or residence times over 8 min, discoloration, black specks, and degradation volatiles may form. Accumulation of deposits on mold vents occurs after several hours of continuous cycling when the grade is run wet or over-heated; vent depth should be limited to 0.01–0.03 mm for PBT to prevent flash. Hot-runner manifolds should avoid dead spots, and valve-gate systems are preferred over open hot-runner tips where local stagnation can degrade the flame-retardant package.
Table 1 summarizes representative property ranges for flame-retardant PBT classes. The values should not be read as guaranteed grade-specific minima or maxima; lot-level certificates from the compounder are the operative specification.
| Property | Test method | PBT+GF15 FR V-0 class | PBT+GF30 FR V-0 class | Unfilled FR PBT class |
|---|---|---|---|---|
| Density | ISO 1183-1 | 1.55 g/cm³ | 1.66 g/cm³ | 1.45 g/cm³ |
| Tensile stress at break | ISO 527-1/-2 | 85–95 MPa | 100–115 MPa | 50–60 MPa |
| Tensile strain at break | ISO 527-1/-2 | 1.5–2.5 % | 1.5–2.0 % | 5–10 % |
| Flexural modulus | ISO 178 | 4,500–5,500 MPa | 7,000–8,500 MPa | 2,400–2,800 MPa |
| Charpy notched impact strength, 23°C | ISO 179-1/1eA | 3.5–4.5 kJ/m² | 4.5–5.5 kJ/m² | 3.0–4.0 kJ/m² |
| Heat deflection temperature, 1.8 MPa | ISO 75-1/-2 | 195–205 °C | 200–210 °C | 70–90 °C |
Process-oriented properties are equally relevant. Melt volume flow rate for the PBT+GF15 FR class is commonly 15–25 cm³/10 min under ISO 1133-1:2022 at 250 °C with 2.16 kg load, but the flame-retardant package and glass loading shift this value. Water absorption after 24 h immersion under ISO 62 is approximately 0.1% for the glass-reinforced class. The comparative tracking index measured under IEC 60112 depends strongly on the flame-retardant chemistry and color; grade-specific values may be above 250 V, but a CTI of 250 V or higher is not automatic for all pigment packages.
Connector bodies, relay bases, terminal-block housings, motor brush holders, and sensor enclosures represent frequent application routes for this material class. The combination of UL 94 V-0 flammability, dimensional stability after soldering or reflow, and lower warpage than 30% glass PBT supports multi-cavity production of small electrical components. In connectors with pin pitch below 2.54 mm, mold shrinkage anisotropy and post-mold warpage can produce terminal misalignment; flow-direction shrinkage in the 0.5–0.8% range and transverse shrinkage in the 0.7–1.1% range require gate location optimization rather than uniform shrink compensation. Dimensional stability in humid service is better than polyamide 66, because PBT absorbs less moisture; under 23 °C/50% RH conditioning to equilibrium, the glass-reinforced PBT class commonly absorbs below 0.2% water. This limits post-mold dimensional change and helps maintain contact retention forces in connector housings. Electrical property requirements such as dielectric strength are thickness- and processing-dependent: short-term dielectric strength for glass-reinforced PBT is often 20–25 kV/mm at 1.0 mm thickness under IEC 60243-1, but voids, glass-fiber distribution, and moisture reduce this in molded parts. Published data for the specific AM sub-grade is limited; molded-part electrical testing should be performed on the actual cavity geometry.
Processors replacing an unfilled flame-retardant PBT, a non-flame-retardant 15% glass PBT, or a 30% glass PBT in an existing tool often encounter differences in filling pressure, packing behavior, and dimensional tolerance. Because the glass-fiber network increases viscosity relative to unfilled PBT, a higher injection pressure or a faster injection velocity is required for thin walls, but excessive velocity above 200 mm/s may generate frictional heat and local degradation at the gate. When replacing a 30% glass grade, the lower viscosity of the 15% material reduces filling pressure and can permit lower clamp tonnage, but the lower modulus also means snap-fit retention features may need thicker sections or longer engagement to compensate for a flexural modulus reduction of approximately 2,000–3,000 MPa. Shrinkage allowances in the tool should not be transferred without measurement: flow-direction shrinkage for the 15% glass FR class is higher than for 30% glass PBT and lower than unfilled FR PBT. Glass-fiber orientation in existing gates and ribs may differ because the lower fiber content reduces shear-thinning and orientation anisotropy. Tool surfaces should be hardened and vented: glass-fiber abrasion at gates and shut-offs is higher than in unfilled grades, while flame-retardant degradation products can plate out on polished mold surfaces if the melt is overheated or held too long. Wear-resistant gate inserts and coated sprues are common in continuous production.
Regulatory conformity for the flame-retardant system is grade-specific and must be confirmed with the current supplier certificate. The product designation alone does not distinguish halogenated from non-halogen formulations with certainty; the GN and N1 characters in the grade family may indicate a non-halogen route in some Novaduran documents, but the exact chemistry is defined only in the safety data sheet, UL Yellow Card, and ISO 1043-1 marking code. Table 2 lists the verification documents that control the main conformity statements.
| Requirement | Reference | Verification boundary |
|---|---|---|
| Flammability classification | UL 94 | V-0 at supplier-listed thickness; verify current Yellow Card |
| Comparative tracking index | IEC 60112 | Grade-specific value required from certificate; class values above 250 V may not apply to all colors |
| Restricted substances | RoHS 2011/65/EU + (EU) 2015/863 | Confirm specific AM variant via supplier certificate |
| REACH SVHC | EC 1907/2006 | Article 33 declaration required if SVHC exceeds 0.1% w/w; verify lot |
The operational ceiling for this class is set by the flame-retardant package and the PBT ester backbone. Above 280 °C, decomposition accelerates and produces volatile products that may irritate respiratory pathways and leave mold deposits; melt purgings should be handled with local exhaust ventilation and thermally stable purging compounds. The material is not intended for prolonged contact with hot water above 60 °C under mechanical load, because PBT hydrolysis reduces molecular weight and can lower impact resistance over service life. Contact with strong acids and alkaline solutions should be avoided, as PBT esters are hydrolytically sensitive at high pH and elevated temperature. For applications requiring food-contact status or medical-grade documentation, published data for this specific configuration is limited, and such uses require separate supplier qualification. The current UL Yellow Card, lot-specific certificate of analysis, and safety data sheet remain the binding documents for acceptance.