| HS Code | 648808 |
As an accredited LyondellBasell HDPE M5370RF W&C factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Typically supplied in 25 kg (55 lb) polyethylene bags, palletized, or 1,000 kg (2,200 lb) bulk bags for LyondellBasell HDPE M5370RF W&C. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with palletized 25 kg bags of LyondellBasell HDPE M5370RF W&C, shrink-wrapped and secured for ocean transport. |
| Shipping | LyondellBasell HDPE M5370RF W&C is a non-hazardous high-density polyethylene resin. Ship as general cargo in sealed bags, octabins, or bulk containers. Keep dry, clean, and away from heat, sunlight, and ignition sources. No UN number, hazard class, or placards required under DOT/IMDG/IATA. |
| Storage | Store LyondellBasell HDPE M5370RF W&C in a cool, dry, well-ventilated area away from direct sunlight, heat, sparks, flames, and strong oxidizers. Keep containers tightly closed, clean, and labeled. Avoid moisture, contamination, and prolonged UV exposure. Use grounding to prevent static buildup, and follow the manufacturer’s SDS and local regulations. |
| Shelf Life | Shelf life is typically 24 months from production when stored unopened, dry, below 50°C, away from direct sunlight. |
In solid primary insulation for copper twisted-pair telephone and central-office exchange cables, LyondellBasell HDPE M5370RF W&C is run as a thin-wall dielectric over 19 AWG 0.91 mm and 22 AWG 0.64 mm annealed-copper conductors. The natural resin variant is required for this application because conductive carbon black raises dissipation factor and reduces insulation resistance under high-frequency telecom signals. The compound is processed on a single-screw wire-coating line with a 25:1 L/D barrel, a 3:1 compression-ratio polyolefin screw, and a pressure-type crosshead die. Barrel zone temperatures are set at 180 °C, 200 °C, 215 °C, and 220 °C from feed to metering; head and die are held at 225 °C and 228 °C respectively. Melt temperature at the die lip is maintained at 225 °C ± 3 °C to avoid both low-temperature melt fracture and high-temperature carbonyl formation. Vacuum drying is unnecessary when incoming pellet moisture is below 0.1 wt%, but predrying for 2 h at 70 °C is specified when ambient relative humidity exceeds 60% or when regrind exceeds 15 wt%. The dielectric formulation uses 0.12 phr to 0.18 phr hindered phenolic antioxidant and 0.05 phr to 0.08 phr copper deactivator. Dielectric constant measured per ASTM D150-18 at 1 MHz is held at 2.30 to 2.35, and dissipation factor is held below 0.0005 at 1 MHz. Insulation wall thickness is controlled to 0.15 mm ± 0.02 mm for 22 AWG and 0.20 mm ± 0.02 mm for 19 AWG at line speeds from 250 m/min to 450 m/min; screw speed and capstan speed are linked by a diameter gauge feedback loop. Draw ratio is kept at 2.0:1 to 3.5:1 to reduce frozen-in stress. The coated conductor enters a three-zone water trough at 70 °C, 45 °C, and 23 °C to minimize residual stress, followed by inline spark testing at 5 kV AC on dry insulation before take-up. Finished twisted-pair cables are evaluated under ANSI/ICEA S-85-625 and applicable UL 444 limited-smoke requirements when a flame-retardant outer jacket is applied over the core. This insulation is limited to conductor temperatures not exceeding 75 °C continuous and should not be substituted into dry 90 °C service classifications unless a higher-temperature dielectric is specified.
For outdoor loose-tube fiber optic cable, the outer jacket must maintain a minimum nominal wall of 0.8 mm to 1.2 mm over water-blocked tubes and a central strength member. In this use, LyondellBasell HDPE M5370RF W&C is formulated as a black jacketing compound with 2.5 wt% ± 0.2 wt% carbon black of particle size not exceeding 60 nm, dispersed through a masterbatch at 5.5% to 6.5% letdown. The melt flow rate of 0.7 g/10 min at 190 °C and 2.16 kg load, measured under ISO 1133-1:2022, imposes a practical upper screw speed of 85 rpm on a 60 mm single-screw extruder with 24:1 L/D when a 40/60/80 mesh screen pack is installed. Melt pressure before the breaker plate is kept below 350 bar to avoid excessive shear heating and gel formation. Barrel temperatures are set at 200 °C, 215 °C, 230 °C, 235 °C, and 235 °C from feed to metering, with head 230 °C and die 230 °C. The jacket is extruded through a pressure-type tube die with an outer land length of 12 mm. Jacket tensile properties after conditioning 48 h at 23 °C and 50% RH are tested per ASTM D638-14 on Type IV specimens; acceptance is typically ≥ 24 MPa tensile yield and ≥ 600% elongation at break, but lot-specific values are confirmed against release certificates. Environmental stress crack resistance is measured per ASTM D1693-15(2021) in 10% Igepal CO-630 at 50 °C; cable-grade HDPE typically exceeds 1000 h F50, though published data for this exact configuration are limited and should be verified with the supplier. Carbon black dispersion is assessed by ASTM D5596, and oxidative induction time is measured by ASTM D3895-19 at 200 °C. The limiting processing factors are melt fracture at high line speed, carbon black dispersion defects, and die drool from low-molecular-weight species. Adding 0.02% to 0.05% fluoropolymer processing aid reduces melt pressure by 8% to 12% and permits a practical line speed increase from 35 m/min to 45 m/min without sharkskin, but it changes surface energy and should not be introduced without adhesion verification to flooding compounds. The finished outdoor loose-tube cable is evaluated under IEC 60794-3-10 for family specifications, including jacket integrity and water penetration resistance.
| Carbon black content | Elongation at break, ASTM D638-14 (%) | ESCR F50, ASTM D1693-15(2021) (h) | OIT at 200 °C, ASTM D3895-19 (min) | Weatherability after 2000 h, ASTM G154 cycle 1 |
|---|---|---|---|---|
| 2.0 wt% | 620–650 | 800–1000 | 45–55 | No cracking, ΔE < 5 |
| 2.5 wt% | 600–620 | >1000 | 50–60 | No cracking, ΔE < 3 |
| 3.0 wt% | 550–600 | >1000 | 55–65 | No cracking, ΔE < 2 |
Microduct coextrusion for blown-fiber installation consumes LyondellBasell HDPE M5370RF W&C in the outer HDPE layer, where stiffness and resistance to installation damage are required. The outer layer formulation contains 2.2% to 2.6% carbon black masterbatch and 0.3% to 0.8% antioxidant masterbatch, while the inner layer includes 3% to 5% silicone-based slip additive. Two single-screw extruders feed a coextrusion die with inner layer thickness of 0.10 mm to 0.15 mm over a total wall of 0.75 mm to 0.90 mm for a 7.0 mm outside diameter microduct. Vacuum calibration sleeves set the outer diameter within ± 0.05 mm; line speeds are typically 40 m/min to 90 m/min depending on diameter. Main extruder barrel temperatures are set at 190 °C, 210 °C, 220 °C, and 225 °C from feed to metering, with head and die at 225 °C. The coextruded duct is coiled at 25 °C and later tested for collapse resistance under 0.5 MPa at 80 °C for 2 h according to internal supply contract criteria; this requires the outer HDPE to retain enough crystallinity to resist wall buckling while the inner slip layer prevents fiber blowing friction increase. Low-temperature coiling is checked at -20 °C without cracking. The finished microduct is installed as bundles or single tubes into 40/33 mm HDPE protective duct or direct buried, and construction is evaluated under IEC 60794-5-20 for blown-fiber microduct systems. M5370RF W&C is not used as the inner slip layer unless a low-friction modifier is added because unfilled HDPE produces excessive surface friction against air-blown fiber units.
For hybrid fiber-coax and CATV drop connections, LyondellBasell HDPE M5370RF W&C is extruded as the outer jacket over an aluminum tube or aluminum-polymer laminate screen and foamed polyethylene dielectric core. The jacket wall is generally 0.8 mm to 1.0 mm for RG-6 and 1.0 mm to 1.2 mm for RG-11. Because the jacket must protect against repeated foot traffic and household installation torque while allowing clean stripping with a rotary coaxial cable stripper, hardness and tensile yield are controlled. Typical values are 62 to 64 Shore D per ISO 868 at 23 °C and tensile yield of 25 MPa to 27 MPa per ASTM D638-14. The processing window is narrow: melt temperature above 240 °C causes surface oxidation and increases adhesion to the underlying PE, making stripping force rise above 25 N on a two-blade stripping tool. A melt temperature of 225 °C at die entry improves peel cleanliness. The jacket formulation includes 2.5% carbon black and no migratory slip additive above 0.1%, because excess erucamide or oleamide reduces tool grip on the jacket surface. Carbon black dispersion must meet fewer than 5 visible particles per 100 cm² when examined against an illuminated screen; poor dispersion creates pinholes that fail the 2.5 kV DC inline spark test used on drop cable lines. Extrusion equipment for this application typically includes a 60 mm single-screw extruder with 24:1 L/D and a barrier screw, fitted with a 20/40/60 mesh screen pack. The finished RG-6 and RG-11 drop cables are installed between tap and subscriber and are evaluated under ANSI/SCTE 74 for braided coaxial drop cable physical and mechanical requirements, with jacket-specific checks referenced to the cable manufacturer test plan. M5370RF W&C provides enough melt strength to maintain wall uniformity at line speeds up to 80 m/min, while the 0.7 g/10 min melt flow rate measured under ISO 1133-1:2022 supports the required draw-down without excessive die swell.
Steel-tape-armored low-voltage distribution cables for direct burial require an outer polyethylene sheath that withstands underground installation abrasion, soil chemicals, and temperature variations. LyondellBasell HDPE M5370RF W&C is processed directly over a flooding compound-coated armor layer at a wall thickness of 1.2 mm to 1.6 mm depending on cable diameter. The compound is fed at 195 °C to 225 °C through a 25:1 L/D extruder with a barrier screw and a cylindrical die. For this application, separation from the armor is controlled by the flooding compound rather than by polar adhesion; therefore the HDPE sheath should not include migratory slip additives above 0.1%, which could reduce longitudinal water-blocking performance. Jacket samples are tested to ASTM D1248-14 Type III, Class C, Category 5 for HDPE wire and cable jacket, with tensile strength ≥ 24 MPa and elongation ≥ 600% per ASTM D638-14. Low-temperature brittleness is assessed per ASTM D746-20 at -50 °C; no more than 5% failure is permitted. After extrusion, the cable is subjected to a 10 kV DC spark test for jacket integrity and then to water penetration evaluation according to the applicable IEC 60502-1 constructional requirements for 0.6/1 kV cables. The finished cable is installed in underground duct or direct buried, where the HDPE sheath protects against moisture ingress and mechanical impact. The sheath is not used where continuous cable surface temperature exceeds the maximum service temperature specified in the supplier datasheet, and compatibility with the flooding compound should be verified by a 7-day immersion test at 60 °C before production release.
| Property | Method | Typical acceptance criterion |
|---|---|---|
| HDPE classification | ASTM D1248-14 | Type III, Class C, Category 5 or equivalent |
| Tensile yield | ASTM D638-14 | ≥ 24 MPa |
| Elongation at break | ASTM D638-14 | ≥ 600% |
| Low-temperature brittleness | ASTM D746-20 | ≤ 5% failure at -50 °C |
| ESCR F50 | ASTM D1693-15(2021) | > 1000 h in 10% Igepal CO-630 at 50 °C |
| Oxidative induction time | ASTM D3895-19 | > 40 min at 200 °C |
Central loose tube construction for fiber-optic cables uses LyondellBasell HDPE M5370RF W&C as the single tubular element that holds up to 24 optical fibers of 250 μm diameter in a thixotropic water-blocking gel. The tube is extruded on a tube-on line with a 25:1 L/D single-screw extruder at melt temperature 220 °C to 230 °C; the die tip and nipple are selected to produce an inner diameter of 2.8 mm and outer diameter of 3.2 mm, with wall variation controlled within ± 0.05 mm by multi-axis ultrasonic wall monitoring. The critical material requirement is environmental stress crack resistance because gel contact and residual tube strain after cabling can accelerate cracking. The grade is processed with 0.15 phr antioxidant and 0.05 phr copper deactivator if copper-based water-blocking tapes are used; carbon black is usually not included in the central tube unless the tube itself is exposed in a dry-core design. Melt filtration through a 60/80/100 mesh pack is specified to prevent gel particles from causing tube wall defects. The tube is filled with gel at 0.2 MPa to 0.4 MPa and sealed immediately, then stranded longitudinally with water-swellable yarns and outer jacketed. Tube integrity is evaluated under IEC 60794-1-21 mechanical test methods, with particular attention to post-tensile loss and temperature cycling from -40 °C to 70 °C. In central tube cable designs, the M5370RF W&C tube must also survive pullout force during jacket stripping without collapsing, so compression resistance is verified at 10 N/10 mm flat-plate compression and compared against the manufacturer’s construction specification. This application is separated from the jacketing sections because the polymer is in direct contact with filling gel and optical fibers, not exposed to soil or sunlight.
Competitive LyondellBasell HDPE M5370RF W&C prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618136850665
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!