    Specifications
    HS Code 614714
    Density 1.08 g/cm³
    Melt Flow Rate 220 C 10 Kg 20 g/10 min
    Tensile Strength At Yield 48 MPa
    Elongation At Break 25%
    Flexural Modulus 2,000 MPa
    Flexural Strength 70 MPa
    Notched Izod Impact Strength 23 C 12 kJ/m²
    Rockwell Hardness R105
    Heat Deflection Temperature 1 82 Mpa 75°C
    Vicat Softening Temperature 90°C
    Light Transmittance 88%
    Haze 2%
    Mold Shrinkage 0.4-0.6%

    As an accredited Lotte Chemical STAREX® MABS TX-0520T factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Lotte Chemical STAREX® MABS TX-0520T is supplied in 25 kg moisture-resistant paper bags, palletized for safe handling and transport.
    Container Loading (20′ FCL) Lotte Chemical STAREX® MABS TX-0520T is palletized, loaded into a 20′ FCL container, and secured for safe ocean shipment.
    Shipping Lotte Chemical STAREX® MABS TX-0520T is shipped as non-hazardous thermoplastic resin pellets, not classified as dangerous goods for transport (no UN number, hazard class, or packing group). It is typically packed in moisture-barrier bags or bulk containers and should be kept dry, cool, and away from direct sunlight.
    Storage Store Lotte Chemical STAREX® MABS TX-0520T in a cool, dry, well-ventilated area away from direct sunlight, heat, sparks, and open flames. Keep containers tightly closed and use original packaging to prevent moisture contamination and dust. Avoid contact with incompatible oxidizers and follow the supplier’s SDS. Maintain good housekeeping and prevent static buildup.
    Shelf Life Shelf life is typically 24 months from manufacture when stored in unopened original packaging, cool, dry, well-ventilated, away from direct sunlight.
    Application of Lotte Chemical STAREX® MABS TX-0520T

    In in-vitro diagnostic instrument manufacture, TX-0520T is processed as a housing material for benchtop analyzers where the transparent top window must resist incidental contact with reagents and cleaning agents. The pellet is pre-dried in a desiccant dryer with a dew point of −30°C to −40°C at 80°C for 3–4 h; residual moisture above 0.05% produces splay and silver streaking in flat sections thicker than 2.0 mm. A screw with 22:1 L/D and compression ratio 2.2:1 is used, with barrel set points of 210°C–230°C–240°C and nozzle at 235°C. Melt temperature measured by an immersion probe should remain between 230°C and 245°C; below 225°C the thin window area of 0.8 mm can short-shot, while above 250°C the butadiene phase begins thermo-oxidative degradation and the molded part shows yellow local discoloration. Mold temperature is controlled at 45°C–60°C with turbulent-flow water circuits; surface gloss replication exceeds 95% of the SPI A-1 polish only when the coolant ΔT across the mold is held below 2°C. Cytotoxicity testing is conducted per ISO 10993-5:2009 and skin sensitization per ISO 10993-10:2010. For reusable housings, wipe cleaning with 10% aqueous isopropanol is permitted; undiluted ketones such as acetone and methyl ethyl ketone are excluded because stress cracking initiates within 15 min under applied hoop stress of 10 MPa. Gate location is placed away from the optical path because gate blush causes a local haze increase above 0.5% per ASTM D1003-21 when the first-stage injection velocity exceeds 80 mm/s.

    Why Does Gate Vestige Control Matter in Optical Cosmetic Closures?

    Injection molding of transparent lipstick cases, compact mirror frames, and perfume cap components with TX-0520T uses multi-cavity tooling from 4 to 16 cavities. The gate type is selected as a hot-runner valve gate with a tip orifice of 0.8–1.2 mm; remaining gate vestige height exceeding 0.05 mm creates a visible blemish when inspected under 10x magnification and is rejected after plating or metallization. When tinting, 1.0–2.0 wt% of styrene-acrylonitrile-based masterbatch is pre-blended in a low-speed paddle mixer at 30 rpm for 10 min; liquid color is limited to 0.2–0.5 wt% because excess carrier alters melt viscosity and increases gate blush. The injection profile uses a two-stage velocity: 60–80 mm/s for the first 60% of fill, followed by 20–30 mm/s for gate-area packing. Hold pressure is set at 50–60% of the peak injection pressure. Cycle time for a 2.0 mm wall closure in an 8-cavity mold is 22–28 s when the mold temperature is held at 50°C. Chemical compatibility testing with fragrance oils is mandatory because esters and terpenes can plasticize the butadiene domain; formulations containing more than 5% ethyl acetate by weight are rejected after 72 h immersion if visible microcracking appears under 20x microscopy. Compliance under EU Regulation (EC) No 1223/2009 requires migration testing and organoleptic contact testing for the final pack after 7 days at 40°C.

    Thermoformed rigid trays for sterile medical device packaging are extruded from TX-0520T as monolayer sheet in thicknesses from 0.25 mm to 1.50 mm. A single-screw extruder with 30:1 L/D, barrier screw design, and screen pack of 60/100/60 mesh is set to a flat melt temperature profile of 210°C–220°C–230°C. The polished three-roll stack is maintained at 70°C–85°C to reduce die lines and optical waviness. Sheet haze measured per ASTM D1003-21 remains below 2.0% for 1.0 mm thickness only if the die lip gap is 10–15% greater than final sheet gauge and the melt filter differential pressure does not exceed 50 bar. Thermoforming uses aluminum female tools with zone-controlled surface temperature 120°C–135°C; plug assist is set to 0.5 s delay with 60–70% penetration depth. Corner thinning on a 30 mm draw depth part is held above 0.18 mm by using a 1.5:1 plug-to-cavity area ratio. The formed tray is sealed to Tyvek; seal transfer at 140°C and 0.4 MPa for 0.8–1.2 s is validated per ISO 11607-1:2019. Microbial barrier after ethylene oxide exposure per ISO 11135:2014 requires residual plate counts evaluated on the tray flange. Since MABS absorbs moisture in high-humidity cleanrooms, pre-dry sheet at 70°C for 2 h is mandatory before thermoforming when ambient relative humidity exceeds 60%.

    Transparent control interfaces on household appliances impose lower thermal limits.

    Control-knob windows and display lenses on washing machines and air-conditioner panels are injection molded from TX-0520T in wall thicknesses of 1.2 mm to 3.0 mm. The Vicat softening temperature measured per ISO 306:2022 Method B50 is approximately 85–90°C for unannealed moldings; therefore the part must be located at least 40 mm away from solenoid-operated steam valves or PTC heating elements where local skin temperature exceeds 60°C. In appliance production, molds are run with a cycled mold temperature of 40°C–55°C; higher mold temperatures create sink marks above 0.02 mm behind the bosses located on the non-appearance face. The material is overmolded onto ABS or high-impact polystyrene frames in a 2K process only when the substrate melt temperature is held above 200°C to achieve interlayer adhesion; a lower substrate temperature leads to delamination in the clamping area after 500 thermal cycles from 5°C to 60°C. Detergent wipe testing uses a 5% anionic surfactant solution at 50°C for 24 h; no visible crazing or haze change greater than 0.5% per ASTM D1003-21 is accepted. Because MABS is intrinsically UV-stable only in indoor conditions, outdoor appliance panels are excluded unless a UV cap layer is coextruded or a 0.3–0.5 wt% hindered amine light stabilizer package is added. The final assembly is tested to IEC 60335-1:2020 with the transparent component evaluated for flammability under glow-wire conditions at 650°C; if the thickness is under 1.5 mm, additional flame-retardant modification is not recommended because halogenated systems reduce clarity. Published data for the specific grade in appliance certification schemes is limited; molders validate each color lot against the original equipment manufacturer’s visual standard.

    Application segmentMelt temperature rangeMold temperature rangeWall thickness rangeKey rejection threshold
    Diagnostic housing230–245°C45–60°C0.8–2.5 mmSplay at moisture > 0.05%
    Cosmetic closure235–250°C50–60°C0.9–2.0 mmGate vestige > 0.05 mm
    Appliance lens225–240°C40–55°C1.2–3.0 mmSink mark > 0.02 mm
    Electronic diffuser220–240°C35–50°C0.8–2.5 mmHaze drift > 1.0% after damp heat
    Office window225–240°C40–50°C1.0–2.0 mmFlash in sections < 1.0 mm

    When Gamma Sterilization Replaces Ethylene Oxide in Disposable Device Components

    MABS components intended for single-use diagnostic cartridges or fluid retainers require sterilization validation under ISO 11137-1:2006 and dose audit per ISO 11137-2:2013. Ethylene oxide at 55°C and relative humidity 60–70% produces little color shift, but aeration time of 12–24 h is required to reduce ethylene oxide residue below 4 mg per device as required by ISO 10993-7:2008. Gamma radiation at 25 kGy causes radical oxidation in the butadiene phase; the result is yellowing measurable by ASTM E313-20 as a yellow index increase, and notched Izod impact retention per ASTM D256-23 is typically in the range 60–80% relative to unirradiated bars for general MABS formulations. Because published data for TX-0520T under gamma is limited, dose range studies with 15 kGy, 25 kGy, and 40 kGy are necessary for each part geometry before release. Molded stress concentration increases radiation embrittlement; the criterion for acceptance is no crack longer than 0.5 mm after post-irradiation conditioning of 7 days at 23°C. Parts with internal undercuts and sharp corners below 0.2 mm radius are generally unsuitable for gamma; the design rule is to maintain a minimum radius-to-wall-thickness ratio of 0.3. Ethylene oxide remains the preferred method for transparent parts with high optical requirements, but the packaging must include gas-permeable header material validated under ISO 11607-2:2019.

    For smart-home devices, routers, and remote optical sensors, TX-0520T is used as a molded light diffuser or IR-transparent window between 0.8 mm and 2.5 mm thickness. Total luminous transmittance for 2.0 mm polished plaques is measured per ASTM D1003-21 at 88–92%; haze remains below 1.5% when the melt temperature is kept below 240°C and the screw recovery time is under 8 s. A diffusing surface texture, typically MT-11010 or equivalent, is laser-engraved into the cavity steel with a depth of 6–10 µm; deeper texture above 15 µm reduces total transmission by more than 3% and creates a perceptibly grey tint. For IR-transparent windows, near-infrared transmission between 800 nm and 950 nm is maintained above 80% when unpigmented material is used; TiO₂-based white masterbatch is excluded because it scatters in the IR range. The material carries a UL 94 HB classification at 1.5 mm, which restricts its use as a fire enclosure in mains-connected products unless the internal power source is limited to 15 W or a secondary enclosure meets IEC 62368-1:2023 fire safeguards. Molding is performed on a 800 kN electric injection machine with a 20 mm screw; injection pressure of 90–110 MPa is required for the thin textured areas. Gate freeze time is set to 0.5–0.8 s after pack; premature gate release causes sink marks over the gate pad that are counted as rejects after 48 h under shop-floor lighting. The assembly is subjected to 96 h of damp heat at 40°C/90% RH per IEC 60068-2-78:2012; haze drift above 1.0% is considered a failure.

    Melt Filtration and Drying Requirements for Extruded Cosmetic Sheet

    Extrusion of high-clarity cosmetic packaging sheet from TX-0520T requires a screen changer with 40 µm absolute filtration after 200/400/200 mesh and a melt pump to stabilize output within ±0.5%. The extrudate temperature is limited to 210°C–225°C because gels from degraded butadiene appear as fisheyes larger than 0.15 mm at higher residence time. A dual-bed desiccant dryer is run at 75°C for 4 h to bring residual moisture below 0.03%; the return air dew point is logged at −40°C. Material conveying is closed-loop and unheated, as hot-air conveying causes pellet skin oxidation and raises haze by 0.3–0.7% in sheet form. The sheet is calendered through a vertical three-roll stack with rolls at 65°C top, 75°C middle, and 85°C bottom; roll gap pressure is adjusted to a nip load of 20–30 N/mm. Edge trim is reintroduced at 10–15 wt% with a maximum of 3 regrind passes because repeated heat history lowers the molecular weight and shifts the Vicat softening point by approximately 2–4°C. The resulting sheet at 0.8 mm thickness is used for thermoformed blush compact platforms and display trays where flatness must remain below 0.05 mm per 100 mm length after 24 h at 40°C. Compliance with EU Regulation (EC) No 10/2011 on plastic food contact is not assumed unless migration testing with the final cosmetic product is performed because fatty ointments can extract low-molecular-weight fractions above the 10 mg/dm² overall migration limit.

    Office equipment covers, barcode scanner windows, and point-of-sale terminal lenses are injection molded from TX-0520T where dimensional stability under continuous indoor service is required. The tensile yield stress measured per ASTM D638-14 is in the range 42–48 MPa at 23°C, and the flexural modulus per ASTM D790-17 is approximately 2100–2500 MPa. These properties permit snap-fit assembly with a maximum strain of 1.2–1.5%; higher strain, especially near weld lines, initiates microcracking when exposed to cleaning agents containing quaternary ammonium compounds at 2% concentration. The recommended mold temperature is 40°C–50°C, and clamping force is calculated at 4–6 kN/cm² of projected area to prevent flash in lenses below 1.0 mm. A melt residence time exceeding 10 min must be avoided; the screw retraction stroke should not exceed 1.5 D to prevent black specks in clear parts. The optical window is masked with a peelable film applied in-mold or post-mold; no silicone spray is allowed because silicone migration increases contact angle and creates hazing after 72 h at 60°C. Office equipment standards apply under IEC 60950-1:2005 legacy designs or IEC 62368-1:2023 current designs, with the clear part excluded from structural enclosure requirements unless it passes a 0.5 kg steel ball impact at drop height 0.5 m. The grade is not recommended for document scanner platen glass replacement because its surface hardness is insufficient; Taber abrasion testing per ASTM D1044-19 shows haze increase above 5% after 100 cycles with CS-10F wheels under 500 g load, which is outside the optical performance window for contact imaging.

    Application segmentStandard/methodTest conditionAcceptance criterion
    Diagnostic housingISO 10993-5:200924 h extractionCytotoxicity grade 0–1
    Medical trayISO 11607-1:2019140°C seal transferContinuous seal width
    Appliance lensIEC 60335-1:2020Glow-wire 650°CNo ignition > 5 s
    Electronics diffuserIEC 62368-1:2023Fire enclosureHB limited to 15 W
    Office windowASTM D1044-19CS-10F, 500 g, 100 cyclesHaze increase < 5%
    Cosmetic closureEU Regulation (EC) No 1223/200972 h fragrance immersionNo visible crazing
    Free Quote

    Competitive Lotte Chemical STAREX® MABS TX-0520T prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Lotte Chemical STAREX® MABS TX-0520T is a transparent injection-molding grade of methyl methacrylate-acrylonitrile-butadiene-styrene terpolymer. The material is distinguished from opaque ABS by the incorporation of methyl methacrylate, which adjusts the refractive index of the grafted polybutadiene rubber phase relative to the styrene-acrylonitrile matrix and reduces light scattering at the rubber-matrix interface. Typical optical performance approaches 90 % total luminous transmittance at 3.2 mm section thickness when measured according to ISO 13468-1. TX-0520T is specified for appearance-critical injection-molded parts, including cosmetic packaging, small appliance windows, clear medical device housings, light-guide supports, and consumer electronics accessories. It is not a general-purpose ABS substitute in applications requiring opacity or high rubber-phase loading for extreme low-temperature ductility. The grade is supplied in pellet form and is intended for melt conversion on conventional reciprocating-screw injection molding machines with closed-loop barrel temperature control.

    What Moisture and Thermal Boundaries Govern Stable Melt Conversion?

    Moisture control is the primary processing constraint because residual water in the melt phase produces splay, silver streaking, and localized haze in transparent MABS components. Pellets are dried in a desiccant dryer with a supply-air dew point no higher than -30 °C and a set-point of 80 °C for 3–4 h. Target residual moisture must remain below 0.02 % by weight, verified by Karl Fischer titration or a calibrated moisture analyzer such as a thermogravimetric halogen system operating under ISO 15512. Drying should be performed with continuous air circulation; hopper loaders must not reintroduce ambient air at relative humidity above 60 % into the dried resin stream.

    Melt temperature measured by an inserted needle pyrometer should be maintained between 220 °C and 250 °C. Typical barrel zone settings use a flat or slightly rising profile from rear zone 200–210 °C through center zone 225–235 °C to nozzle zone 240–250 °C. Hot-runner manifolds and nozzle tips are limited to 250 °C. Residence time above 250 °C should not exceed 3–5 min because slow color-body formation appears as an increase in yellowness index under ISO 11664-4 CIE color measurement. Mold surface temperature is held between 40 °C and 70 °C. Mold temperatures below 40 °C reduce knit-line strength and raise frozen-in orientation near the gate; mold temperatures above 70 °C extend cycle time without a corresponding improvement in transparency or impact. For thin-wall parts below 1.0 mm, mold-temperature uniformity across the cavity should be controlled within ±5 °C using multiple water circuits or oil-temperature control units.

    Injection velocity profiling is required to avoid jetting and trapped air in transparent parts. For wall sections between 1.0 mm and 2.5 mm, fill time is typically set to 0.5–1.5 s in production-scale multi-cavity tooling. Hold pressure is ramped from 60–80 MPa to 20–30 MPa over 6–10 s, followed by cooling time that is determined by part thickness and gate freeze. Back pressure during screw recovery is kept low, generally below 10 bar hydraulic equivalent, to limit shear heating and molecular decomposition. Screw rotation speed is controlled within 60–120 rpm on a 40 mm screw diameter. Published process data for this specific grade under high-speed thin-wall molding are limited; therefore, initial trials should be conducted with an instrumented mold to record cavity pressure and confirm short-shot limits.

    Mechanical and Optical Response of TX-0520T

    The property set of TX-0520T positions the material as an intermediate between PMMA and high-impact ABS. Typical mechanical and optical values reported on supplier technical data sheets are summarized below. These values are not specification limits and may vary with processing history, colorant package, and specimen conditioning.

    PropertyTest methodTypical value
    DensityISO 1183-11.08 g/cm³
    Melt volume-flow rate, 220 °C/10.0 kgISO 1133-1:202221 cm³/10 min
    Tensile stress at yieldISO 527-2/5046 MPa
    Nominal strain at breakISO 527-2/5018 %
    Flexural modulusISO 1782100 MPa
    Flexural strengthISO 17866 MPa
    Charpy notched impact, 23 °CISO 179/1eA10 kJ/m²
    Vicat softening temperature, VST/B/50ISO 30694 °C
    Haze, 3.2 mmISO 147823.0 %
    Total luminous transmittance, 3.2 mmISO 13468-190 %

    From a regulatory and chemical-resistance standpoint, TX-0520T requires the same attention to environmental stress cracking as other MABS materials. REACH SVHC screening under EC 1907/2006 Article 33 and RoHS Annex II screening by X-ray fluorescence according to IEC 62321-3-1 are typically supplied in the product compliance statement. The grade is not provided as an inherently medical-certified polymer; any use in medical device housings or drug-contact components requires separate qualification under ISO 10993-1 and final product assessment. Chemical exposure limits should be evaluated according to ISO 22088-3. The material resists dilute aqueous acids and bases at ambient temperature but is attacked by ketones, esters, aromatic hydrocarbons, and some lipid-based cleaning formulations. Stress-cracking tests are mandatory if the molded part contacts alcohol-based disinfectants or cosmetic oils. Avoid compounding or melt-line contact with polycarbonate residues, because transesterification reactions at high temperature can generate gas defects and reduce optical clarity.

    When TX-0520T Replaces PMMA in Thin-Wall Optical Housings

    The replacement of PMMA with TX-0520T is technically justified when impact toughness, melt-flow length, or reduced cycle time is the controlling variable rather than surface hardness or long-term outdoor weathering. Under ISO 179/1eA, the notched impact of TX-0520T is approximately 10 kJ/m² at 23 °C, while PMMA typically exhibits values near 2 kJ/m². Flexural modulus measured under ISO 178 is lower for TX-0520T at approximately 2100 MPa compared with PMMA at approximately 3300 MPa. This reduction in stiffness can cause visible deflection in snap-fit enclosures unless ribs and wall thickness are redesigned. Melt-processibility differences are also significant: TX-0520T fills thin-wall flow lengths at lower melt temperature and lower injection pressure than PMMA, but the upper continuous service temperature is lower. PMMA retains dimensional stability to higher heat-deflection temperatures, while TX-0520T is limited by a Vicat point near 94 °C and a heat-deflection temperature under ISO 75-2/B at 1.80 MPa of approximately 84 °C.

    Transparent housings for indoor cosmetic or appliance use are suitable when the part is not exposed to sustained ultraviolet light. The material can be processed in multi-cavity molds with hot-runner valve gates; conventional transparent-PMMA molds require lower polishing costs because MABS reproduces mold surfaces with lower viscosity. However, surface scratch resistance is inferior to PMMA. If scratch resistance is measured by pencil hardness under ISO 15184 or Taber haze increase under ISO 9352, PMMA will generally show lower visible damage. Hardcoats or UV-capped coextrusion are necessary for outdoor lenses or automotive exterior applications. For indoor light-guide plates or cosmetic caps with wall stocks below 1.2 mm, TX-0520T is run at lower clamp forces than comparable PC grades; a 1200 kN machine can often be used for tools that would require 1500 kN or more with polycarbonate because cavity pressure is lower and packing is shorter.

    Comparative Differentiation Against Opaque ABS and Impact-Modified MABS

    The primary difference between TX-0520T and general-purpose opaque ABS is compositional. Standard ABS has a two-phase morphology in which the refractive index of the polybutadiene rubber particles differs sufficiently from the SAN matrix to scatter visible light, producing opacity. MABS introduces methyl methacrylate into the matrix or the graft layer, lowering the refractive-index mismatch and permitting total luminous transmittance values near 90 %. This optical advantage comes with a toughness trade-off. High-impact opaque ABS grades can exhibit notched Charpy values above 20 kJ/m² or even 30 kJ/m², depending on rubber content and particle-size distribution, while TX-0520T remains near 10 kJ/m². The MABS grade therefore should not be selected for cold-temperature snap-fit closures or high-energy consumer goods housings designed for opaque ABS drop-impact specifications.

    Within the MABS category, TX-0520T is formulated as a high-flow injection-molding grade. Relative to standard MABS grades with lower melt volume-flow rate, TX-0520T reduces fill pressure and improves replication of fine surface features in multi-cavity tooling. The flow-length advantage is most visible in spiral-flow mold tests or short-shot studies conducted under ISO 294-1 specimen-definition conditions. However, high flow is generally associated with a modest reduction in molecular weight or rubber-phase continuity, so TX-0520T may show slightly lower environmental stress-crack resistance than lower-MFR MABS grades. For applications requiring contact with aggressive creams, alcohol-based hand sanitizers, or ester-containing fragrances, a lower-flow MABS or an impact-modified acrylic may be more suitable unless stress-cracking qualification under ISO 22088-3 demonstrates acceptable performance.

    Compared with polycarbonate, TX-0520T does not require mold temperatures above 90 °C to maintain transparency. This provides a cycle-time and energy-cost advantage in clear multi-cavity packaging tools. Polycarbonate retains higher impact, higher heat-deflection temperature, and better ductility at low temperature, but is more sensitive to alkaline hydrolysis and requires elevated drying at 120 °C. TX-0520T dries at 80 °C, which allows simpler material-handling systems. The trade-off is that TX-0520T cannot meet cyclic autoclave sterilization at 121 °C or 134 °C; it is not recommended for reusable steam-sterilized medical devices. Ethylene oxide or gamma sterilization may be evaluated only through final product testing under ISO 11135 or ISO 11137-1. Published data for this specific resin in industrial gamma-sterilized device programs is limited; therefore, verification by post-sterilization color and impact testing is required before production release.

    Processing failures observed on actual manufacturing lines commonly include gate blush, splay due to incomplete drying, and yellowing after hot-runner residence. These failures are reduced by maintaining moisture below 0.02 %, limiting nozzle and hot-runner temperatures to 250 °C, and avoiding use of regrind above 20 % by weight unless optical performance is confirmed by haze measurement under ISO 14782. The product is supplied in a pellet form that can be conveyed through standard vacuum loaders, but pellet dust from regrind handling increases the risk of surface defects in transparent parts. Dedicated transparent-resin storage hoppers and cleaned mold surfaces are required to maintain the low haze level near 3.0 % at 3.2 mm thickness.

    Top