| HS Code | 564400 |
| Density | 1.31 g/cm³ |
| Water Absorption | 0.08% |
| Mold Shrinkage | 0.7-1.0% |
| Tensile Strength At Break | 50 MPa |
| Elongation At Break | 30% |
| Flexural Modulus | 2300 MPa |
| Flexural Strength | 80 MPa |
| Notched Izod Impact Strength | 4 kJ/m² |
| Hdt At 0 45 Mpa | 150 °C |
| Hdt At 1 8 Mpa | 60 °C |
| Melting Point | 225 °C |
| Volume Resistivity | 1E16 ohm·cm |
| Dielectric Strength | 20 kV/mm |
As an accredited LG Chemical Keyflex® PBT Unfilled BT-1030D factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | LG Chemical Keyflex® PBT Unfilled BT-1030D is supplied in 25 kg moisture-barrier bags, palletized for secure industrial storage and handling. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with LG Chemical Keyflex® PBT Unfilled BT-1030D in standard export packaging, palletized, secured, and evenly distributed. |
| Shipping | Shipped as pelletized resin in sealed moisture-barrier 25 kg bags, palletized and stretch-wrapped. Store in a cool, dry, ventilated area away from sunlight, heat, and moisture. Handle per SDS; generally non-hazardous for transport. Avoid bag damage and contamination. |
| Storage | Store LG Chemical Keyflex® PBT Unfilled BT-1030D in its original sealed containers or bags in a cool, dry, well-ventilated warehouse, protected from direct sunlight, heat, and moisture. Keep away from ignition sources and strong oxidizers. Reseal opened packages promptly, rotate stock, and follow supplier drying recommendations before processing. |
| Shelf Life | Typical shelf life is 12 months in original sealed packaging, stored dry, below 30°C, away from moisture and direct sunlight. |
Competitive LG Chemical Keyflex® PBT Unfilled BT-1030D prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
LG Chemical Keyflex® BT-1030D is an unfilled polybutylene terephthalate (PBT) injection-molding resin positioned in the medium-flow region of the Keyflex® PBT portfolio. The grade is supplied as pellets formulated without glass fiber or mineral filler, so the melt-rheological response is governed primarily by the polyester backbone and its molecular weight distribution. Manufacturer technical data report a melt volume-flow rate at 250 °C under a 2.16 kg load of 18 cm³/10 min when measured according to ISO 1133-1:2022. Density under ISO 1183-1:2019 is approximately 1.31 g/cm³. These two values define the design space: the resin is fluid enough for multi-cavity electrical parts but remains below the high-flow grades used for sub-0.5 mm wall connectors or high-cavitation micro-molding.
At the property level, an unfilled PBT of this class exhibits flexural modulus below 2500 MPa under ISO 178:2019, while a 30 wt% glass-fiber-reinforced PBT commonly exceeds 8000 MPa. BT-1030D is therefore selected for parts that do not require structural stiffness but must fill complex geometries with lower melt pressure and reduced fiber-induced anisotropy. Its tensile strength at yield is approximately 54 MPa under ISO 527-2:2012, and failure is ductile with elongation at break above 100 % in some reported datasets; published data for this specific configuration should be confirmed against the current manufacturer certificate. The absence of glass fiber also removes a principal cause of warpage in reinforced grades: differential shrinkage along flow and transverse directions. Whereas a 30 wt% glass-fiber PBT may show flow-direction shrinkage near 0.3 % and transverse shrinkage near 1.0 %, the unfilled grade typically shows mold shrinkage in the range 1.7 %–2.0 % under ISO 294-4:2018.
Compared with impact-modified unfilled PBT, BT-1030D displays a notched Charpy impact value around 4 kJ/m² at 23 °C under ISO 179-1:2010. Snap-fit designs requiring ductile fracture at low temperatures or high strain-rate loading may require an impact-modified grade. Against flame-retarded grades, an unfilled, unmodified PBT generally carries only a UL 94 HB rating; V-0 classification at thin wall sections requires halogenated or phosphorus-based flame-retardant packages that alter flow, mold deposit behavior, and thermal stability.
Within unfilled PBT ranges, melt volume-flow rate values typically span 12 cm³/10 min to 30 cm³/10 min under the same ISO condition. BT-1030D at 18 cm³/10 min therefore sits near the middle of that distribution. This positioning reduces short-shot risk in thin-wall fill relative to low-flow extrusion grades, but it does not match the filling behavior of a 30 cm³/10 min high-flow PBT in sub-0.5 mm micro-connector geometries. High-flow grades usually sacrifice impact and long-term hydrolysis resistance because lower molecular weight translates into fewer chain entanglements; the medium-flow selection retains a measurable margin of ductility for small snap-fit arms.
Processing behavior is dominated by two factors: rapid crystallization at quench-rate-dependent temperatures and moisture-induced ester hydrolysis. In production, a desiccant dryer capable of delivering air at a dew point below -30 °C is required when pellets are exposed to ambient humidity above 50 % RH. Drying at 120 °C for 3 h to 4 h reduces pellet moisture to a target below 0.02 %. Moisture above 0.03 % at the hopper produces splay, nozzle drool, and a progressive loss in tensile strength because hydrolytic chain scission reduces molecular weight. On reciprocating-screw machines with L/D 20:1 and compression ratio 2.2:1, barrel settings range from 235 °C at the rear zone to 250 °C at the front and nozzle. Melt temperature should be maintained between 245 °C and 260 °C. Extended residence above 260 °C causes discoloration and a reduction in elongation at break; accumulated melt residence time should not exceed 8 min for this grade.
Mold temperature is the primary control for crystallinity development. A mold temperature of 60 °C to 80 °C is recommended for parts requiring stable dimensions and improved heat deflection; lower mold temperatures between 30 °C and 40 °C may be used for fast cycle times but can produce underdeveloped crystallinity, higher post-mold shrinkage, and lower HDT. Injection pressure is typically set between 60 MPa and 100 MPa at the screw tip, with hold pressure adjusted until the cavity pressure transducer records a transfer point at 95 %–98 % of fill volume. Back pressure between 5 MPa and 10 MPa and screw surface speed between 60 min⁻¹ and 120 min⁻¹ maintain melt homogeneity without generating excessive shear heat. Cushion should be kept above 3 mm; shot-weight instability at cushion values below 2 mm has been observed as poor filling repeatability in multi-cavity tools.
Gate diameter must be at least 50 % of local wall thickness because the gate freezes rapidly once the melt drops below the crystallization temperature, and premature seal prevents packing. For walls between 1.0 mm and 2.5 mm, a round gate diameter of 0.8 mm to 1.2 mm and land length under 1.0 mm are typical. Hot-runner needle valves should be used in place of open sprue bushings when stringing, drool, or gate vestige control is critical.
| Parameter | Set point | Control method or instrument |
|---|---|---|
| Drying temperature | 120 °C | Desiccant dryer |
| Drying time | 3–4 h | Dew point -30 °C or lower |
| Maximum pellet moisture | 0.02 % | Karl Fischer or moisture analyzer |
| Rear barrel | 235–245 °C | Thermocouple |
| Front barrel | 250–260 °C | Thermocouple |
| Melt temperature | 245–260 °C | Air-shot pyrometer |
| Mold temperature | 60–80 °C | Water temperature control |
| Injection pressure | 60–100 MPa | Screw-tip pressure transducer |
| Back pressure | 5–10 MPa | Hydraulic pressure transducer |
| Cushion | 3–6 mm | Linear position |
| Maximum residence time | 8 min at 250 °C | Shot counter × cycle time |
In electrical connector housings and relay sockets, BT-1030D is used where median flow, predictable shrinkage, and electrical-insulation performance are adequate for ambient and mildly heated environments. The heat deflection temperature under 1.8 MPa load is approximately 55 °C when tested according to ISO 75-2:2013; continuous load-bearing service above this value is outside the unfilled grade’s mechanical reliability envelope. For parts that must survive reflow soldering above 240 °C, the grade is generally unsuitable unless the process is vapor-phase reflow with controlled dwell below the HDT; high-heat PBT or glass-fiber-reinforced grades are required.
Typical property data reported for the grade are consolidated in the table below; they should be read as representative values rather than batch-release specification limits.
| Property | Standard | Value |
|---|---|---|
| Density | ISO 1183-1:2019 | 1.31 g/cm³ |
| Melt volume-flow rate | ISO 1133-1:2022 | 18 cm³/10 min |
| Tensile strength at yield | ISO 527-2:2012 | 54 MPa |
| Tensile elongation at break | ISO 527-2:2012 | >100 % |
| Flexural modulus | ISO 178:2019 | 2300 MPa |
| Flexural strength | ISO 178:2019 | 80 MPa |
| Notched Charpy impact at 23 °C | ISO 179-1:2010 | 4 kJ/m² |
| HDT/A, 1.8 MPa | ISO 75-2:2013 | 55 °C |
| Mold shrinkage | ISO 294-4:2018 | 1.7 %–2.0 % |
| Water absorption, 24 h | ISO 62:2008 | 0.08 % |
Electrical insurer listing is generally UL 94 HB at 0.8 mm thickness for unfilled and unmodified PBT; comparative tracking index and glow-wire performance must be evaluated on the finished part because additives, colorants, and molding strains affect the result. Published data for this specific grade’s CTI is limited; values for unfilled PBT often exceed 400 V but cannot be assumed without a certification file.
Thermal degradation pathways in PBT shift from reversible ester interchange to irreversible vinyl-ester decomposition as residence time accumulates. In an injection unit, this manifests initially as yellowing and an increase in melt pressure variation; later, tetrahydrofuran-related odours may appear and the melt viscosity decreases through chain scission. Because BT-1030D is unfilled and of medium viscosity, the torque signal may remain inside the machine alarm band while the polymer is already degrading. Shot-to-shot variation in cushion position and nozzle pressure should be interpreted as a residence-time warning, not corrected solely by raising back pressure. The safe response is to reduce barrel temperature to the lower end of the melt window and purge the barrel with a fresh PBT charge. Unlike some glass-fiber-reinforced grades that tolerate brief excursions to 270 °C, the unfilled grade’s degradation threshold is lower because no reinforcing filler moderates shear heating or local overheating. Barrel-temperature profiling should be established with an air-shot pyrometer at start-up, and measured melt temperature should not deviate by more than ±5 °C from the nominal setting when controlled by closed-loop barrel thermocouples. This operational boundary is particularly relevant to hot-runner systems with poorly swept dead zones and to high-cycle molding cells running below 15 % of barrel capacity, where the material spends a large fraction of the cycle in the plastication zone.
In multi-cavity connector manufacturing, the unfilled grade is commonly selected when nominal wall thickness is 0.8 mm to 2.5 mm and the maximum service temperature under mechanical load remains below 55 °C. The resin fills thin ribs and snap-fit geometries at moderate pressures, but the low notched impact strength of roughly 4 kJ/m² under ISO 179-1:2010 must be designed around by eliminating sharp corners, enlarging radii, and orienting weld lines away from high-strain regions. For terminal blocks, coil bobbins, and switch components, molding trials with water-heated tools at 60 °C reduce part-to-part shrinkage variation by promoting more repeatable crystallinity than low mold-temperature operation. Applications involving continuous exposure to hot water above 60 °C, strong aqueous acids, or organic amines are outside unfilled PBT’s established compatibility envelope because hydrolysis and amine-induced degradation reduce molecular weight. If a part requires V-0 flammability, a specifically flame-retarded Keyflex® grade or a glass-fiber-reinforced PBT with a documented UL Yellow Card classification should be selected instead of BT-1030D.