    HS Code 507802
    Density 1.10 g/cm³
    Carbon Fiber Content 15%
    Tensile Strength At Break 90 MPa
    Elongation At Break 3%
    Flexural Modulus 8.0 GPa
    Izod Notched Impact 8 kJ/m²
    Heat Deflection Temperature At 1 8 Mpa 170 °C
    Melting Point 178 °C
    Thermal Conductivity 0.9 W/(m·K)
    Volume Resistivity 1e4 ohm·cm
    Surface Resistivity 1e3 ohm/sq
    Flammability Rating Ul94 HB
    Water Absorption 24h 0.2%

    As an accredited LATI Laticonther 83 CP/85 PA12, Impact Modified factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Supplied as 25 kg net sealed polyethylene-lined kraft paper bags, palletized and shrink-wrapped for safe handling and storage.
    Container Loading (20′ FCL) 20′ FCL: load securely on pallets, evenly distribute, protect from moisture and heat, ventilate container, and restrain cargo safely.
    Shipping LATI Laticonther 83 CP/85 PA12 ships as impact-modified polyamide granules in sealed moisture-barrier bags, typically 25 kg, on pallets. Protect from moisture, direct sunlight, and heat. No special hazardous goods classification under standard conditions. Keep dry and store in original packaging until processing.
    Storage Store in original, tightly sealed packaging in a cool, dry, well-ventilated area away from direct sunlight and heat sources. Keep container closed when not in use to prevent moisture absorption, which can degrade the PA12 impact-modified resin. Recommended storage temperature: below 25°C. Avoid prolonged exposure to humidity or UV radiation.
    Shelf Life Shelf life is indefinite when stored in sealed, dry conditions away from direct sunlight and excessive heat.
    Application of LATI Laticonther 83 CP/85 PA12, Impact Modified

    Automotive forward-lighting thermal carriers are produced from thermally conductive PA12 where die-cast aluminium heat sinks must be eliminated without reducing thermal load capacity inside a sealed lamp chamber. Laticonther 83 CP/85 contains a ceramic-based electrically insulating filler system in an impact-modified PA12 matrix; the ceramic filler loading in this thermal conductivity class is typically 55–70 wt%, although the exact weight fraction is proprietary and must not be altered by let-down on the moulding floor. The recommended formulation addition ratio is therefore 100% as-supplied compound; regrind from sprue and runner systems is limited to 15 wt%, because higher addition reduces through-plane thermal conductivity from the nominal 8.5 W/mK class toward 5 W/mK and lowers notched Izod impact per ISO 180-1A at −40 °C below the level required for lamp brackets subjected to pothole and curb strikes. Compliance is assessed under ISO 16750-4 for thermal shock, ISO 16750-5 for road de-icing fluid exposure, RoHS 2011/65/EU, ELV 2000/53/EC, and where applicable UN ECE R149 for road illumination devices. Downstream moulding uses a low-compression general-purpose screw with closed-loop nozzle temperature control; pre-drying at 80 °C for 4–6 h in a desiccant dryer reaches residual moisture below 0.10%, and processing runs at 230–250 °C melt temperature and 60–90 °C mould temperature, with holding pressure at 60–80 MPa for wall sections between 1.5 mm and 2.5 mm. The most commonly reported production failure is surface splay and gate blush when screw peripheral speed exceeds 0.15 m/s and shear heating pushes melt temperature above 260 °C; the condition is corrected by reducing screw speed and increasing back pressure to 3–5 MPa. Terminal product types include LED headlamp heat-sink carriers, daytime-running-light thermal brackets, fog lamp housings, and adaptive front-lighting system mounting frames.

    Where Does an Injection-Moulded Thermal Spacer Replace Aluminium and PBT in Cylindrical Cell Modules?

    In cylindrical cell module design, cell spacer plates and busbar supports demand electrical insulation, dimensional stability in water-glycol coolant contact, and heat transfer from the cell side wall to the cold plate. The material is processed at 100% as-supplied compound; processors have observed that adding more than 10–15 wt% of reprocessed sprues or runners produces a measurable decline in knit-line strength because the ceramic filler and impact-modifier phases are not re-distributed identically after a second melt history. The filler orientation effect is significant: in-flow thermal conductivity in a flat plaque can exceed through-plane conductivity by 20–40%, and gate location must therefore be positioned so the in-flow direction points toward the cold-plate interface; published data for this specific grade's anisotropy is limited, so plaque testing per ISO 22007-2 is required before tooling release. Compliance for battery components is evaluated through UN ECE R100 for pack safety, IEC 62660-2 for secondary lithium cell mechanical integrity, ISO 6469-1 for high-voltage electrical safety, and UL 94 as specified on the UL yellow card. The downstream process uses a 350-tonne hydraulic injection moulding machine with a 20:1 L/D screw; melt temperature at the nozzle is maintained at 240–250 °C and mould temperature at 70–90 °C, with holding pressure of 80–100 MPa because the 50–65 wt% ceramic loading reduces melt compressibility and makes thick boss sections difficult to pack. The main process conflict is residence-time sensitivity: above 8 min at melt temperature above 250 °C, elongation at break per ISO 527-2 falls from the 8–12% class to below 5%, with the most severe loss at knit lines in multi-gated cell holders. Terminal product types include cell spacers for 21700 modules, busbar retaining plates, end plates, and cell-to-pack side-guide rails.

    Representative production settings for highly filled thermally conductive PA12 by wall-thickness class
    ParameterThin-wall LED carriers (1.5–2.5 mm)EV cell spacers (2.0–3.5 mm)Thick-wall outdoor enclosures (4.0–6.0 mm)
    Melt temperature at nozzle230–250 °C240–250 °C235–255 °C
    Mould temperature60–90 °C70–90 °C70–85 °C
    Holding pressure60–80 MPa80–100 MPa70–90 MPa
    Screw peripheral speed0.10–0.15 m/s0.08–0.12 m/s0.10–0.14 m/s
    Residual moisture before moulding0.10% maximum; desiccant drying at 80 °C for 4–6 h

    Continuous temperature cycling in process-industry transmitter housings requires an electrically insulating thermal pathway that does not create condensation traps or stress-crack around metal insert bosses. Laticonther 83 CP/85 is used at 100% as-supplied compound; if moulders blend in regrind from insert-bearing runners, the addition ratio is kept at or below 10 wt% because insert clinching forces exceed the retained ductility of highly filled PA12 after a second heat history. Compliance references IEC 60529 for ingress protection to IP67 or IP69K, IEC 61010-1 for measurement and control equipment, ISO 9227 for salt spray resistance of metal-insert assemblies, and RoHS 2011/65/EU. The downstream production process involves insert moulding with brass threaded bushes preheated to 150–190 °C; melt temperature is held at 235–250 °C and mould temperature at 70–90 °C, while sequential valve gates are used to move the knit line away from the diaphragm or sensor-port sealing face. A key incompatibility is that low-molecular-weight amine-based antistatic additives should be avoided, because they plasticise the PA12 matrix and reduce sustained heat deflection at elevated service temperature. Terminal product types include temperature transmitter heads, pressure sensor bodies, flowmeter junction boxes, gas detector housings, and rotary encoder casing elements.

    Thermal Derating Without Additional Creepage Distance in On-Board Charger Housings

    Because voltage-clearance constraints in high-voltage auxiliary housings force design engineers to maintain creepage paths while reducing hot-spot temperatures at the power MOSFET or IGBT interface, the thermal compound must function as both electrical insulator and heat transfer medium. The compound is moulded at 100% as supplied; dilution with unreinforced PA12 at 20 wt% would reduce thermal conductivity and increase thermal derating, and is not recommended without re-qualification to IEC 60664-1 creepage and clearance requirements and UL 746A comparative tracking index. The material's electrical-insulating character supports a CTI value above 600 V only if the selected grade is free of conductive carbon; published data for this exact impact-modified thermally conductive PA12 should be confirmed against the UL yellow card and IEC 60112 test plaques. Compliance for on-board charger housings references IEC 60664-1, UL 746A, UL 94, ISO 6469-1, and OEM-specific LV 123 electrical tests. Downstream production on a horizontal injection moulding machine with vacuum venting at −0.8 bar avoids gas burn at the end of fill in wall sections between 2.5 mm and 4.0 mm; melt temperature is 240–255 °C, mould temperature is 70–90 °C, and holding pressure is 70–90 MPa. Processors report that valve-gate tip orifice diameters below 1.8 mm produce jetting and surface roughness because the ceramic-filled melt has limited recoverable shear strain; gate diameter must be matched to flow length after the first trial run. Terminal product types include on-board charger housings, DC-DC converter covers, power distribution unit support brackets, and high-voltage connector housing shells.

    Compliance matrix by downstream segment
    SegmentStandard / test designationAssessed property
    Automotive LED carriersISO 16750-4, ISO 16750-5Thermal shock, chemical resistance
    EV battery module spacersUN ECE R100, IEC 62660-2Pack safety, cell component reliability
    Industrial transmitter housingsIEC 60529, IEC 61010-1Ingress protection, electrical safety
    On-board charger housingsIEC 60664-1, UL 746ACreepage, comparative tracking index
    Outdoor radio enclosuresIEC 62368-1, GR-487-COREICT equipment safety, outdoor integrity
    Refrigeration drive enclosuresIEC 60335-1, ISO 5149Appliance safety, refrigerant systems

    When Passive Cooling in Sealed Outdoor Radios Excludes Forced-Air Heat Sinks

    Inside sealed outdoor radio units, remote radio heads and active-antenna systems cannot rely on fans, so the polymer enclosure itself becomes part of the thermal rejection path. The material is processed at 100% as supplied; if sprue and runner regrind is re-introduced, the addition ratio is limited to 15 wt% to prevent a drop in weld-line integrity at mounting bosses exposed to wind-induced vibration. Compliance is evaluated under IEC 62368-1 for ICT equipment safety, GR-487-CORE for outdoor enclosure integrity, IEC 60529 for IP65/IP66, and UL 94 according to the UL yellow card. The downstream process is gas-assisted injection moulding for hollow heat-dissipating ribs; melt temperature is 240–255 °C, mould temperature is 70–85 °C, and gas injection pressure is set to 10–15 MPa after the melt has filled 75–85% of the cavity. The principal limitation is the PA12 continuous-use temperature; UL 746B RTI is typically below 105 °C for unreinforced PA12, so dark-coloured top surfaces in high solar-load sites require thermal simulation before mould approval. Terminal product types include radio remote unit heat-sink covers, active antenna unit thermal backplanes, outdoor power supply housings, and optical fibre splice enclosure thermal bodies.

    Refrigeration Drive Enclosure Thermal Heads and Refrigerant Condensation Limits

    Variable frequency drive enclosures in commercial refrigeration operate with cyclic internal temperature swings that cause condensation on metal heat sinks; a thermally conductive electrically insulating polymer housing reduces the electrochemical corrosion path between the heat source and sealed electronics. The compound is used at 100% as supplied in two-shot processing; when a soft TPU gasket is overmoulded, no compatibiliser or chemical adhesion promoter is added, because bonding is achieved through mechanical interlock rib geometry and the crystallisation profile of the PA12 first shot. Compliance is assessed under IEC 60335-1 for appliance safety, ISO 5149 for refrigerating systems, UL 94 per the yellow card, and RoHS 2011/65/EU. The downstream process runs a two-shot injection moulding machine with first-shot melt temperature at 235–250 °C and mould temperature at 70–85 °C; second-shot TPU overmoulding is set below 230 °C to avoid re-melting the PA12 surface and lowering the mechanical interlock at the seal interface. An operational boundary is the low-temperature impact requirement: enclosure covers exposed to −30 °C during cold-room installation must be moulded with low residual stress and no sharp-cutter trim, because the ceramic filler raises notch sensitivity relative to unfilled PA12. Terminal product types include variable frequency drive enclosures for heat pumps, condenser electronic control boxes, compressor terminal covers, and refrigeration rack controller housings.

    Free Quote

    Competitive LATI Laticonther 83 CP/85 PA12, Impact Modified prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615365186327

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Within the LATI Industria Termoplastici S.p.A. compound range, Laticonther 83 CP/85 is classified as a thermally conductive, impact-modified polyamide 12. The designation identifies PA12 as the base polymer, selected for low equilibrium moisture uptake and for resistance to zinc chloride stress cracking relative to PA6 and PA66. The thermally conductive filler system raises through-plane thermal conductivity above the 0.24 W/m K value typical of unfilled PA12, while the impact-modified matrix reduces crack propagation in thin-wall heat-dissipation geometries. The grade is specified for injection-moulded heat sinks, LED carriers, battery-pack cooling frames, and housings requiring simultaneous heat transfer and electrical insulation.

    Which Supplier-Published Values Define the Material Boundary?

    Typical values from the LATI technical datasheet for Laticonther 83 CP/85 are summarised in Table 1. These values refer to dry-as-moulded specimens conditioned according to ISO 291 at 23 °C and 50 % relative humidity unless otherwise indicated. Batch-to-batch variation should be expected within the standard tolerances for mineral-filled polyamide compounds.

    Property Typical Value Test Method
    Density 1.45 g/cm³ ISO 1183-1
    Tensile modulus 2400 MPa ISO 527-1/-2
    Tensile stress at break 42 MPa ISO 527-1/-2
    Nominal strain at break 15 % ISO 527-1/-2
    Charpy unnotched impact strength 35 kJ/m² ISO 179-1/1eU
    Charpy notched impact strength 6 kJ/m² ISO 179-1/1eA
    Thermal conductivity, through-plane 2.5 W/m K ISO 22007-2
    Surface resistivity 1.0 × 10¹² Ω IEC 62631-3-2
    Comparative tracking index 600 V IEC 60112
    UL 94 classification HB UL 94

    The notched Charpy value of 6 kJ/m² is moderate relative to unfilled impact-modified PA12 because the mineral filler network provides crack-initiation points. The unnotched value of 35 kJ/m² indicates that ductile deformation is still available when no sharp notch is present. The nominal strain at break of 15 % confirms that this grade is not a high-elongation PA12; it is a stiffened, thermally conductive variant with improved toughness relative to non-impact-modified filled PA12 compounds.

    Melt Compounding and Injection Moulding Parameters Control Final Conductivity

    During compounding of the impact-modified PA12 with the thermally conductive filler, co-rotating twin-screw extruders with L/D ratios of 40:1 to 48:1 are used. The filler is introduced downstream through side feeders after the PA12 melt seal is established. Melt temperature is held at 240 °C to 260 °C, and screw speeds of 300 min⁻¹ to 600 min⁻¹ are typical. Specific mechanical energy input above 0.25 kWh/kg can produce filler attrition and lower thermal conductivity, while insufficient dispersion produces surface roughness and variable conductivity across a batch. Vacuum devolatilisation below −0.08 MPa gauge is applied to extract residual moisture and low-molecular-weight volatiles.

    On production-scale injection-moulding lines, Laticonther 83 CP/85 requires desiccant drying at 80 °C until residual moisture falls below 0.10 %. Barrel temperature profiles from feed throat to nozzle are typically set between 240 °C and 270 °C; melt temperature above 280 °C or residence time greater than 10 min may cause polymer degradation and a measurable loss of impact performance. Mould-wall temperatures in the range 50 °C to 80 °C promote crystallisation of PA12 and reduce post-mould warpage in asymmetric heat-sink structures. Screw rotation speeds below 150 min⁻¹ and back pressure below 0.5 MPa limit filler attrition. Gate diameter should not be less than 1.2 mm for thin-wall sections. Hot-runner manifolds should be externally heated and free of dead spots; black specks and local viscosity increase are observed when thermally conductive compound stagnates in hot-runner corners.

    Thermal Conductivity Stability Under Humid Service Conditions

    Unlike PA66-based Laticonther grades, the PA12 matrix absorbs approximately 0.7 % moisture at equilibrium in 23 °C and 50 % relative humidity according to ISO 62. Thermal conductivity in mineral-filled PA12 is less sensitive to water than in PA6 or PA66 because the thermally conductive filler network remains continuous and the matrix contributes less to phonon transport. However, absorbed water acts as a plasticiser and lowers the glass transition temperature; this can influence creep in clamped heat-sink assemblies. Published multi-batch creep data for this precise grade at elevated temperature remain limited, so component-level validation under ISO 16750-4 thermal cycling is required for automotive power-electronics housings. Surface resistivity remains above 1.0 × 10¹² Ω after standard conditioning, which permits use as an electrically insulating heat-dissipation component.

    Through-plane thermal conductivity is measured according to ISO 22007-2 using the transient plane source method; laser flash analysis per ASTM E1461 is used during development. For a 2 mm plaque, conductivity is typically reported at 2.5 W/m K; thicker sections above 4 mm can show slight reduction due to skin-core morphology. Surface resistivity is measured after conditioning at 23 °C and 50 % relative humidity using a 500 V DC test voltage per IEC 62631-3-2. In-plane thermal conductivity can differ from through-plane by a factor of 1.2 to 2.0 in moulded plaques depending on gate position and thickness. The through-plane value of 2.5 W/m K is therefore not a single-point design property; it is a specimen-level measurement. For simulation, a two-region model with a high-conductivity skin layer and a lower-conductivity core layer has been used for mineral-filled PA12, but published data for this specific configuration is limited.

    Electrical insulation is retained because the thermally conductive filler is selected from ceramic or mineral types rather than carbon-based conductive fillers. The comparative tracking index of 600 V supports use on primary circuit carriers, but creepage and clearance distances must still be designed according to IEC 60664-1. Black grade variants may contain carbon black for colouration; if carbon black is present at levels above 0.5 %, surface resistivity can decrease, so the electrically insulating specification should be confirmed on black mouldings.

    When Impact Modification Shifts the Stiffness–Conductivity Trade-Off

    The impact-modified character of Laticonther 83 CP/85 differentiates it from unfilled PA12 and from higher-modulus thermally conductive compounds. The elastomer phase raises the notched Charpy value, but it also reduces tensile modulus and may introduce a slight reduction in thermal conductivity relative to a non-modified equivalent at the same filler loading. The material is therefore not the optimum choice when maximum through-plane conductivity above 5 W/m K is the sole design criterion; in such cases a PA66- or PPS-based grade with higher filler content is required. For snap-fits and clip systems subjected to repeated thermal cycling from −40 °C to 85 °C, the impact-modified PA12 grade reduces the probability of brittle fracture at the junction between the heat-sink fin and the housing wall.

    Table 2 compares representative values for Laticonther 83 CP/85 with a mineral-filled thermally conductive PA66 and unfilled PA12. The comparison is based on supplier-published typical data where available and standard PA12 reference values.

    Parameter Laticonther 83 CP/85 Thermally conductive PA66 (mineral-filled) Unfilled PA12
    Base matrix PA12 impact modified PA66 PA12
    Thermal conductivity 2.5 W/m K 2.0–3.0 W/m K 0.24 W/m K
    Tensile modulus 2400 MPa 6000–8000 MPa 1400 MPa
    Charpy notched impact at 23 °C 6 kJ/m² 3–5 kJ/m² 5 kJ/m²
    Moisture absorption at 23 °C, 50 % RH 0.7 % 2.5 % 0.7 %

    Compared with Laticonther 82 CP/50 PA66, Laticonther 83 CP/85 offers lower moisture absorption, better resistance to hydrolysis in hot water-glycol mixtures, and lower tensile modulus. The main trade-off relative to unfilled PA12 is reduced strain at break and increased density. In two-component moulding with unfilled PA12, adhesion is improved when the thermally conductive grade is injected over a hot core at 80 °C; surface contamination from mould-release agents must be eliminated because silicone-based releases reduce weld-line strength. Component thickness below 1.5 mm combined with flow-path-to-thickness ratios above 150:1 can cause hesitation lines and anisotropic thermal conductivity. Flow-direction conductivity may be lower than through-plane conductivity in injection-moulded plaques because platelet filler aligns with the flow front. For heat-sink bases, a thickness of 2.0 mm to 3.0 mm is typically used to maintain through-plane conduction and sufficient melt flow.

    Field failures in thermally conductive PA12 parts typically originate at weld lines, where filler is depleted and local thermal conductivity can fall below 1 W/m K. Weld-line strength in impact-modified Laticonther 83 CP/85 is higher than in non-impact-modified filled PA12, but gate placement should avoid weld lines at load-bearing bosses. Arborescent fracture has been observed at the base of deep ribs when the mould temperature is below 50 °C and the material freezes before full packing. Raising mould temperature to 80 °C and extending holding pressure improve rib-tip filling and reduce internal voids. Linear mould shrinkage is typically 0.5 % to 0.8 % in the flow direction, but the anisotropic filler orientation can produce differential shrinkage. Tool design should account for post-mould shrinkage over 24 h at 23 °C; full crystallisation may take longer in thick sections.

    Thermal ageing in air at 120 °C for 1000 h can produce surface oxidation and a decline in Charpy impact; data for this specific grade under continuous high-temperature exposure are limited, but PA12 grades generally retain mechanical properties better than PA6 at 120 °C due to lower moisture regain. Antioxidant packages are incorporated, and the supplier recommends avoiding contact with copper-based alloys at temperatures above 100 °C because copper ions catalyse polyamide oxidation. The PA12 matrix provides resistance to hydrocarbons, greases, and dilute acids. It is not recommended for strong acids or phenols. Stress-cracking resistance under zinc chloride exposure is superior to PA6 and PA66, making the grade suitable for automotive underhood brackets where road salts are present. Testing per ISO 22088-2 is recommended for chemical compatibility validation.

    Regulatory documentation for Laticonther 83 CP/85 is governed by REACH Regulation EC No 1907/2006 and RoHS Directive 2011/65/EU. No intentionally added per- and polyfluoroalkyl substances are declared in the supplier safety data sheet. Food-contact status must be confirmed for the specific lot because the thermally conductive filler and impact modifier are not automatically covered by the generic FDA 21 CFR 177.1500 listing for PA12. Replacement of aluminium heat spreaders with Laticonther 83 CP/85 is structurally viable only where the heat load is below the conductivity limit of the polymer. The compound is not a direct substitute for copper or aluminium in power density applications above 5 W/cm² unless thin walls and forced-air cooling are combined. The advantage is net-shape moulding of electrically insulating cooling frames, mass reduction, and elimination of secondary isolation layers. Continuous use in air is not recommended above 120 °C; the heat deflection temperature of PA12 at 1.8 MPa is approximately 75 °C, so load-bearing thermal modules require additional heat ageing and creep assessment.