| HS Code | 685362 |
| Productname | Kraton™ MD SEBS MD8703 HU |
| Polymertype | SEBS (styrene-ethylene/butylene-styrene) block copolymer |
| Chemicalfamily | Hydrogenated styrenic block copolymer |
| Blockstructure | Linear triblock |
| Physicalform | Pellets |
| Appearance | White to off-white pellets |
| Density | 0.90 g/cm³ |
| Styrenecontent | 30 wt% |
| Meltflowrate | 5 g/10 min at 230°C/2.16 kg |
| Shoreahardness | 65 |
| Tensilestrength | 25 MPa |
| Elongationatbreak | 500% |
| 300percentmodulus | 3.0 MPa |
| Tearstrength | 30 kN/m |
| Vicatsofteningtemperature | 70°C |
| Waterabsorption | <0.1% |
| Processingmethod | Injection molding, extrusion, compounding |
| Casnumber | 66070-58-4 |
As an accredited Kraton Kraton™MD SEBS MD8703 HU factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Kraton™ MD SEBS MD8703 HU is packaged in 25 kg moisture-resistant bags, 40 bags per pallet (1,000 kg net). |
| Container Loading (20′ FCL) | A 20′ FCL is loaded with Kraton™ MD SEBS MD8703 HU, palletized and securely braced for safe ocean transport. |
| Shipping | Kraton™ MD SEBS MD8703 HU is supplied as solid SEBS pellets in moisture-barrier bags, typically 25 kg sacks or 1,000 kg supersacks. It is non-hazardous and not regulated for transport. Store dry, protected from heat, sunlight, and moisture; avoid contamination during handling and shipping. |
| Storage | Store Kraton™ MD SEBS MD8703 HU in a cool, dry, well-ventilated area, away from direct sunlight, heat, sparks, and open flames. Keep containers sealed and palletized to prevent moisture and contamination. Avoid prolonged high-temperature or UV exposure. Use first-in, first-out stock rotation and comply with local regulations. |
| Shelf Life | Shelf life is 24 months from manufacture when stored dry, at ambient temperature, in original unopened packaging. |
Medical tubing compounds built on Kraton™ MD8703 HU are typically dry-blended before melt compounding. The polymer is a linear styrene-ethylene-butylene-styrene triblock with a saturated ethylene-butylene midblock. A representative enteral feeding set compound uses 35–45 wt% MD8703 HU, 15–25 wt% random copolymer polypropylene, 20–35 wt% medical-grade white mineral oil, and 0.2–0.5 wt% phenolic/phosphite stabiliser. The batch is fed into a co-rotating twin-screw extruder with 40:1 L/D ratio and side-injection ports for oil addition. Barrel set points rise from 160 °C at feed to 230 °C at the die. Melt temperature is maintained below 240 °C to limit molecular weight loss. Screw speed is typically 300–500 rpm with torque not exceeding 85% of motor capacity. A gear pump between the extruder and die head stabilises melt pressure. The pelletised compound then enters a single-screw tube extruder with 24:1 L/D and a 25 mm screw. Die temperature is set between 170 °C and 190 °C. Draw ratio is controlled between 3:1 and 5:1 to avoid excessive orientation and steam-sterilisation shrinkage. The extrudate is quenched in a 10–15 °C water bath to limit oil migration to the tube surface. Surface moisture can cause bubble defects when ambient relative humidity exceeds 60%; sealed fresh pellets are preferred. Inline pinhole detection uses spark test voltage of 5 kV/mm wall thickness. Finished peristaltic pump tube segments are tested for cytotoxicity and irritation under ISO 10993-5, ISO 10993-10, and USP Class VI. Extractables are controlled by selecting low-aromatic white oils and by limiting oil loading above 45 phr. Higher oil levels reduce viscosity but increase the risk of surface bloom and pump spallation. Gamma sterilisation validation is required. Published data for this specific compounded configuration at 25–50 kGy gamma dose is limited; terminal sterilisation mapping under ISO 11137 must be executed per lot.
In automotive interior polypropylene compounding, MD8703 HU is added at 10–25 wt% as the impact-modification phase. The compound is processed on a twin-screw extruder with 44:1 L/D ratio, vacuum devolatilisation at -0.08 MPa, and barrel temperatures from 190 °C to 230 °C. High-shear dispersion is required to reduce SEBS domain size. Domain sizes above 1–2 µm reduce low-temperature impact response. Screw design should include kneading blocks in 30–45% of the mixing section length. Higher MD8703 content increases impact strength and elongation at break. Flexural modulus measured by ISO 178 declines as the elastomer fraction rises. Melt flow rate is determined under ISO 1133-1 at 230 °C with 2.16 kg load. The flow reduction controls thin-wall fill pressure in edge-gated moulds. Vacuum devolatilisation below 0.09 MPa removes residual process oil and low-molecular-weight volatiles. Automotive interior compounds are screened under VDA 278 for volatile organic compound and fogging emissions. Hydrogenated midblock grades such as MD8703 HU tend to give lower fogging counts than unsaturated SBS alternatives. Notched Izod impact is measured by ASTM D256 at -20 °C and 23 °C. Differential shrinkage between SEBS-rich and PP-rich regions can cause warpage in large door panel inserts; tool temperature uniformity above ±3 °C variation is recommended. Terminal parts include door panel inserts, pillar trim, and airbag cover retainer substrates. Melt temperature must remain below 240 °C to limit styrenic end-block degradation and odour generation.
Two-component power tool housings use MD8703 HU as the soft elastomer phase. A typical soft-touch compound contains 25–35 wt% MD8703 HU, 10–15 wt% polypropylene, 30–40 wt% low-aromatic paraffinic oil, and 1–2 wt% hydrophobic fumed silica as a rheology modifier. The blend is prepared in a co-rotating twin-screw extruder with 36:1 L/D at 170–210 °C, pelletised, and then fed to the second injection unit. Barrel temperatures for the soft compound are 180–220 °C, and mould temperature is held at 30–50 °C. Adhesion to polycarbonate/acrylonitrile-butadiene-styrene substrates is not intrinsic. SEBS has low surface energy and does not engage in polar bonding with PC/ABS. A maleic anhydride-grafted polypropylene or SEBS-g-maleic anhydride tie layer at 2–5 wt% is melt-blended into the soft compound to improve peel strength. Without the tie layer, delamination propagates from sharp corner features during demoulding and thermal cycling. Oil migration to the interface destroys adhesion; low-volatility hydrogenated oils with high molecular weight are preferred. Clamp force is calculated from projected area; 3–5 kN/cm² is a common starting range for two-shot mould trials. Injection pressure is maintained at 60–90 MPa to pack the soft component. Finished overmoulds are evaluated for adhesion using a modified ISO 813 peel fixture calibrated for thermoplastic elastomer-to-plastic bonds. Electrical safety evaluations reference UL 94 at 1.5 mm thickness; actual results depend on oil type and package. RoHS and REACH SVHC compliance is documented through supplier declarations.
Reusable medical fluid storage systems are replacing plasticised PVC with MD8703 HU-based monolayer and multilayer films. A typical film compound contains 40–60 wt% MD8703 HU, 20–30 wt% polypropylene or linear low-density polyethylene, 10–20 wt% hydrogenated paraffinic oil, and 0.2–0.5 wt% antiblock. Multilayer blown film lines use skin layers of PP or PE to reduce tack. Die gap is set from 0.8 mm to 1.6 mm, blow-up ratio is 2.5–3.5, and melt temperature is held between 180 °C and 220 °C. The film is quenched with air rings operating at 15–25 °C. Mechanical properties are tested by ASTM D882 for tensile strength and elongation at break, and ASTM D1003 for haze. Blood-contacting applications require hemocompatibility under ISO 10993-4. General fluid containers require cytotoxicity and skin sensitisation under ISO 10993-5 and ISO 10993-10. For collapsible containers, drop impact and water leak are assessed under ISO 3826 requirements. Thermal impulse welding is used for sealing. The sealing window is narrow, typically 190–210 °C with dwell of 2.5–4.0 s. Lower temperatures create incomplete fusion at the interface. Higher temperatures initiate local thinning at the weld edges. Autoclave sterilisation at 121 °C requires seal integrity validation because film softening can reduce weld strength. Published data for platelet oxygen permeability in MD8703 HU film configurations is limited, so storage validation under ISO 3826 and ISO 10993-4 requires product-specific testing. Terminal articles include deplasticised fluid transfer pouches and reusable solution bags.
| Regulatory reference | Endpoint evaluated | Test condition |
|---|---|---|
| ISO 10993-5 | Cytotoxicity | L929 cell line, extract dilution series |
| ISO 10993-10 | Skin sensitisation and irritation | Device contact duration and route-specific methods |
| ISO 10993-4 | Hemocompatibility | Complement activation, thrombosis panel for blood contact |
| USP Class VI | Systemic injection and intracutaneous reactivity | Extract preparation according to USP monographs |
| 21 CFR 177.1810 | Food-contact use of styrene block copolymers | Composition and end-test extraction limits for formulated resin |
| ISO 3826 | Plastic collapsible containers for blood and blood components | Drop impact, water leak, capacity retention |
For medical tape hot-melt pressure-sensitive adhesives, MD8703 HU is melt-blended with hydrogenated tackifier and processing oil. A starting adhesive contains 20–30 wt% MD8703 HU, 35–45 wt% hydrogenated C5 tackifier, 25–35 wt% white mineral oil, and 0.5–1.0 wt% antioxidant. Mixing is performed in a sigma-blade mixer at 150–180 °C until the tackifier is fully solubilised. Continuous slot-die coating runs at 130–160 °C with coat weight controlled to 25–50 g/m². Brookfield viscosity at 180 °C is adjusted to 5–20 Pa·s, measured with spindle 27 at 10 rpm. Higher viscosity causes die drool. Lower viscosity reduces shear holding power. The adhesive is coated onto breathable nonwoven or polyethylene film carriers. Skin-contact layers are evaluated for cytotoxicity under ISO 10993-5 and irritation under ISO 10993-10. Loop tack is measured by ASTM D6195. Shear holding power is recorded at 40 °C with 1 kg load. Formulators should avoid amine-based tackifiers because they destabilise the midblock and increase colour. Oil migration into the carrier is controlled by using hydrogenated paraffinic oils with viscosity greater than 40 cSt at 40 °C. High-volume continuous lines may replace sigma-blade mixing with twin-screw extrusion; shear heating must be controlled to limit tackifier degradation. Finished articles include medical fixation tapes and wear-time-extended wound dressings.
Consumer electronics cable jacketing compounds place strict limits on oil extension. MD8703 HU is the base elastomer phase. The compound includes 30–40 wt% MD8703 HU, 10–15 wt% polypropylene as a crystalline reinforcement phase, 25–35 wt% paraffinic or naphthenic oil, and 50–65 wt% magnesium hydroxide or aluminium trihydrate flame retardant. The twin-screw compounding line uses 40:1 L/D with split feeding. Polymer and polypropylene enter the main throat. Filler is side-fed at 10–12 barrel diameters downstream. Oil is injected after filler dispersion. Melt temperature is kept below 210 °C when aluminium trihydrate is used because its water-release onset is near 190 °C. Magnesium hydroxide is preferred for higher-temperature compounds because its decomposition onset is above 300 °C. The compound is extruded onto copper conductors with a single-screw extruder of 30:1 L/D and a 25–30 mm screw. Barrel zones are set from 140 °C in the feed to 200 °C at the crosshead die. Wire preheat is maintained at 90–110 °C to prevent insulation sink marks and microvoids at the conductor interface. High filler loadings increase melt pressure; pressure at the head is typically 12–18 MPa. Flexibility is checked by mandrel bend testing per UL 1581. Flame resistance is evaluated by IEC 60332-1-2. Oil extension beyond 35 wt% lowers tensile strength below typical cable specifications and can cause exudation into the conductor bundle. Terminal uses include USB cable jackets, earphone cable sheaths, and appliance cord sub-jacket layers.
Competitive Kraton Kraton™MD SEBS MD8703 HU prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Kraton™ MD8703 HU is a linear hydrogenated styrenic block copolymer of the SEBS type, consisting of terminal polystyrene blocks and a saturated poly(ethylene/butylene) midblock. The manufacturer specifies the bound styrene content as 13 wt%; the product is supplied as a high-molecular-weight, dense pellet for melt compounding rather than as a ready-to-use thermoplastic elastomer. The MD prefix is commonly associated with Kraton medical-grade polymers, but the regulatory scope of MD8703 HU should be confirmed against current supplier documentation. Specific gravity is approximately 0.90 g/cm³ when measured by ASTM D792, although filler and oil addition modify the final compound density. The saturated midblock distinguishes the polymer from unhydrogenated SBS triblocks and provides higher melt stability and lower residual unsaturation. Final mechanical and rheological properties depend on oil extension, polyolefin addition, filler type, and stabiliser selection. The high-viscosity profile of MD8703 HU is relevant to processes that require melt strength, including blown film, sheet, profile extrusion, and thin-wall injection moulding. Grade-specific melt-flow data should be taken from the supplier’s certificate of analysis rather than from generic SEBS values; published data for this exact configuration are limited beyond the stated composition and pellet form.
High-viscosity SEBS resins impose specific melt-processing constraints when compounded on co-rotating twin-screw extruders. A typical production line with an L/D of 40:1 uses feed-zone temperatures below 100 °C to prevent pellet blocking, followed by barrel zones from 160 °C to 200 °C and a die set point of 210 °C. Screw speeds of 250–400 rpm generate specific mechanical energy inputs in the range of 0.12–0.20 kWh/kg, with high torque demand resulting from the high molecular weight of MD8703 HU. Feed starvation and output fluctuation can occur if pellet bulk density is low or if forced feeding is absent; production-scale experience shows that gravimetric feeding at 40–60% of screw volume reduces surging. Melt temperature should be maintained below 230 °C to avoid oxidative chain scission and gel-particle formation in the polystyrene end-blocks. When oil extension exceeds 80 phr, dispersive mixing in a 30:1 L/D single-screw extruder is generally inadequate; a separate twin-screw compounding step before final shaping is required. Viscosity control is preferably confirmed by capillary rheometry under ISO 11443 at 190 °C and 210 °C, rather than by melt flow rate, because high-molecular-weight SEBS can fall below the lower detection limit of ASTM D1238 under a 2.16 kg load. These ranges reflect general high-molecular-weight SEBS processing practice, and grade-specific thermal profiling should be confirmed by capillary rheometry under ISO 11443 or by production-scale torque measurement.
Soft compound hardness and tensile profiles are assessed after conditioning according to ASTM D2240 and ASTM D412. Oil-extended systems containing white paraffinic oil and polypropylene can be adjusted from approximately 20 Shore A to 65 Shore A; tensile strength typically declines from around 20 MPa to 3 MPa as oil loading increases from 0 phr to 120 phr. The reduction follows plasticiser dilution of the load-bearing polystyrene network and expansion of the ethylene/butylene midblock free volume. Increasing polypropylene content from 10 wt% to 30 wt% raises modulus and hardness but decreases elongation at break. Migration kinetics of low-molecular-weight oil fractions in polymer matrices must be considered for long-duration patient contact, because surface bloom can alter coefficient of friction and bonding. Extraction testing is therefore conducted on finished medical components under ISO 10993-12, not on the base polymer alone.
Blown film and sheet extrusion impose additional demands because the high melt viscosity of MD8703 HU supports bubble stability and gauge uniformity. Spiral mandrel dies are typically run at melt temperatures of 190–210 °C, die gaps of 0.8–1.2 mm, and blow ratios of 2:1–3:1. Compared with lower-viscosity SEBS grades of similar styrene content, MD8703 HU produces higher melt strength and greater die swell; this stabilises the bubble but raises head pressure and shear heating, so screw speed should be reduced accordingly. Excessive melt temperature above 220 °C can produce surface defects and gel deposition on the die lip; frequent die-lip cleaning or silicone-free processing aids may be required. Lot-to-lot variation in melt viscosity should be monitored through the certificate of analysis because changes in molecular weight distribution affect bubble stability and final film elongation. Published data for this specific configuration is limited, so initial production runs should be designed with wider die-gap adjustment and temperature profiling.
Selection of MD8703 HU over high-styrene SEBS grades such as Kraton G1650 is driven primarily by bound styrene content and the resulting mechanical and rheological response. G1650 is specified at 30 wt% bound styrene; the larger polystyrene-phase volume fraction raises tensile strength, modulus, and hardness but produces stiffer, less ductile compounds at equivalent oil loading. MD8703 HU, specified at 13 wt% bound styrene, provides a larger rubbery midblock fraction and therefore lowers Shore A hardness, tensile modulus, and tensile set in soft compounds, while increasing elongation at break. In polypropylene-based thermoplastic elastomers, the low-styrene grade typically yields softer, more ductile mouldings at the same oil content. However, the less developed glassy polystyrene network also reduces resistance to creep and may lower the upper service temperature relative to high-styrene grades. The choice should be confirmed by comparing compression set under ASTM D395, tensile set under ASTM D412, and low-temperature brittle point under ASTM D746 if sub-zero flexibility is required.
| Grade | Bound styrene content (wt%) | Midblock saturation | Observed hardness trend in unfilled compression-moulded sheet | Primary limitation |
|---|---|---|---|---|
| MD8703 HU | 13 | hydrogenated | 65–75 Shore A | lower creep resistance; requires high-shear compounding |
| G1650 | 30 | hydrogenated | 72–80 Shore A | higher modulus; less softness at equivalent oil loading |
| Unhydrogenated SBS | 30 | unsaturated polybutadiene | 70–80 Shore A | thermal and UV oxidative instability |
For medical and pharmaceutical contact applications, MD8703 HU is typically evaluated as a candidate for fluid delivery, respiratory circuits, and disposable device components. However, the base polymer cannot be declared biocompatible in isolation. Final devices must be tested for cytotoxicity, sensitisation, and irritation under ISO 10993-1, with extractables evaluated under ISO 10993-12. Blood-contacting applications may require additional end-points under ISO 10993-4 and ISO 10993-11. Sterilisation tolerance should be verified for gamma irradiation and ethylene oxide exposure; general SEBS materials retain mechanical properties after gamma doses in the range of 25–50 kGy, but high-dose irradiation can induce surface oxidation and yellowing. Published data for MD8703 HU after sterilisation is limited, so dose-mapping and post-irradiation tensile testing are required for production release. For food-contact use, compliance may be assessed under 21 CFR 177.1810 for styrene block copolymers, subject to limitations on total extractives and end groups. Regulatory statements for REACH and RoHS should be confirmed from the current safety data sheet; migration limits are determined by the final formulation and the intended food or drug-contact use, not by the base polymer alone.
| Evaluation | Primary standard | Typical test method or modal endpoint |
|---|---|---|
| Cytotoxicity | ISO 10993-5 | elution assay on L929 fibroblasts |
| Irritation and sensitisation | ISO 10993-10 | guinea pig maximisation or local lymph node assay |
| Systemic toxicity | ISO 10993-11 | acute and subacute exposure routes |
| Haemocompatibility | ISO 10993-4 | haemolysis, complement activation, thrombosis |
| Extractables and leachables | ISO 10993-12 | solvent extraction and GC-MS/LC-MS analysis |
| USP plastics classification | USP <88> | systemic injection, intracutaneous, implantation |
Compared with unhydrogenated SBS triblocks, MD8703 HU contains a saturated poly(ethylene/butylene) midblock, which improves thermal and oxidative stability during melt processing and outdoor exposure. SBS grades with comparable styrene content are less thermally stable and may undergo viscosity drift or odour generation at processing temperatures above 180 °C. The saturated midblock also reduces UV-initiated chain scission, but stabilisation is still required because the polystyrene end-blocks and added oil remain degradation sites. Thermal stability differences are evaluated by thermogravimetric analysis under ISO 11358-1 or by accelerated heat ageing using appropriately defined conditions; no single base-polymer comparison replaces a full formulation study. MD8703 HU is not a vulcanising grade and should not be compounded with peroxide or sulfur cure systems intended for EPDM or SBS, because crosslinking of the saturated midblock is not the intended route to property development.
Injection moulding of MD8703 HU compounds is usually performed with melt temperatures of 180–210 °C and mould temperatures from 20 °C to 50 °C. The high melt viscosity of the base polymer can generate excessive pressure drop in thin-wall tools; gates with a diameter below 0.8 mm may require elevated injection velocities of 100–200 mm/s to avoid short shots. Production-scale moulding of oil-extended MD8703 HU compounds has shown that hold pressures of 30–50 MPa hydraulic are typical, but the required clamp force depends on projected area and flow length. If surface splay appears, pre-drying of the compounded pellets at 70–80 °C for 2–4 h in a desiccant hopper dryer is applied when moisture content exceeds 0.05 wt%. Moisture-related defects are often intermittent at the start of a production run and decrease after the hopper reaches thermal equilibrium. Grade-specific drying data are limited; operators should verify residual moisture with a moisture balance rather than relying only on hopper residence time.
Medical tubing applications use MD8703 HU where plasticiser migration from flexible PVC is undesirable. Flexible PVC compounds under extraction testing can release significant amounts of low-molecular-weight plasticisers, whereas an oil-extended SEBS compound may be formulated to reduce extractables by selecting high-molecular-weight paraffinic oils. However, oil-extended SEBS compounds are not inherently extraction-free; the extractables profile depends on oil grade, additive package, and processing history. If a low-extractables compound is required, oil content should be minimised and the final device must be tested under ISO 10993-12 rather than inferred from the base polymer. This substitution also affects kink resistance and clamp resilience, which must be tested under appropriate tubing collapse or recovery methods.
SEBS compounds based on MD8703 HU may be joined by solvent bonding only when the selected solvent system dissolves the polystyrene phase without excessive stress cracking. Cyclohexanone and methyl ethyl ketone mixtures can soften the surface, but bond strength depends on the compound’s polystyrene content, oil content, and solvent evaporation rate. Low-styrene grades such as MD8703 HU offer a reduced polystyrene bonding anchor compared with high-styrene SEBS; therefore, weld and bond parameters require revalidation if the compound is changed from a high-styrene grade. For continuous assembly of tubing, radio-frequency welding is generally ineffective on saturated SEBS unless a polar filler or tie layer is introduced; manufacturers often use ultrasonic welding or insert moulding. These assembly constraints should be evaluated on finished devices under production-scale conditions, because laboratory coupons may underrepresent the effect of residual stress and moisture.