| HS Code | 362452 |
| Polymer Type | SEBS (styrene-ethylene-butylene-styrene block copolymer) |
| Molecular Structure | Linear triblock copolymer |
| Styrene Content | 30% |
| Density | 0.90 g/cm³ |
| Melt Flow Rate | 5 g/10 min (230°C/2.16 kg) |
| Hardness | Shore A 65 |
| Tensile Strength | 20 MPa |
| Elongation At Break | 600% |
| 300 Percent Modulus | 5 MPa |
| Vicat Softening Temperature | 70°C |
| Processing Method | Injection molding and extrusion |
| Form | Pellets |
As an accredited Kraton Kraton™MD SEBS MD6041 DT factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Kraton™ MD6041 DT SEBS is packaged in 25 kg bags, palletized for industrial handling and storage. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): Kraton™MD SEBS MD6041 DT in a dry container—palletized, shrink-wrapped, secured, labeled, and protected from moisture. |
| Shipping | Kraton™ MD SEBS MD6041 DT is shipped as a non-hazardous thermoplastic elastomer in pellet form, typically in 25 kg bags or bulk containers. It is not regulated for transport and has no UN number. Keep dry and avoid excessive heat or direct sunlight. |
| Storage | Store Kraton™ MD SEBS MD6041 DT in a cool, dry, well-ventilated area away from direct sunlight, heat sources, ignition, and strong oxidizers. Keep in tightly closed original containers to prevent moisture and contamination. Avoid excessive stacking and dust generation. Follow first-in, first-out stock rotation and local regulations. |
| Shelf Life | Shelf life is 24 months from manufacture when stored dry in original unopened packaging at 5–30°C. |
Kraton MD6041 DT enters downstream evaluation as a hydrogenated styrene-ethylene/butylene-styrene block copolymer with a fully saturated midblock. That saturation removes the butadiene cure sites responsible for nitrosamine precursor formation in traditional sulfur-vulcanized elastomers and allows processing on thermoplastic equipment without vulcanization. Three production constraints are treated as controlling: the melt must not be held above 230°C for extended residence time, feed throat stability depends on pellet dusting uniformity, and high humidity storage above 60% RH may require a 2-hour desiccant drying step at 80°C to prevent surface splay. The application range divides into sterile barrier lidding, infusion set components, respiratory mask cushions, pharmaceutical closures, dynamic pump tubing, and thermoformed device trays. Where published data for a specific grade and end configuration is limited, formulation and process windows are presented as candidate ranges to be confirmed on production-scale equipment.
For peelable lidding film, MD6041 DT is typically let down at 55–75 wt% with a random copolymer polypropylene at 20–35 wt% and a hydrogenated hydrocarbon tackifier at 5–15 wt%. A tie layer of maleic anhydride–grafted SEBS at 3–5 wt% is coextruded to improve adhesion to LLDPE or polypropylene tray flanges. The DT dusting agent, if present as a pellet surface treatment, is not an active sealant component; its concentration should be recorded by lot because batch-to-batch dusting variation can shift seal initiation by altering surface energy and heat transfer at the sealing bar. An antistat addition above 1.0 wt% or an ethylenic slip package above 800 ppm should be avoided because low-molecular-weight species migrate into the seal layer and widen peel-force distribution. Film is cast on a single-screw extruder with L/D 30:1, a barrier screw, screen pack 120/240/120 mesh, melt pump, and a coat-hanger die held at 215–225°C. Chill roll temperature between 22°C and 28°C controls crystallinity of the PP phase; lower roll temperatures increase clarity but can create die-line microgrooves that weaken seal stability. Sealing is run at platen temperature 110–130°C, dwell 0.5–1.0 s, and pressure 0.4–0.6 MPa; peel force is measured according to ASTM F88/F88M-21 at 180° peel angle. Production-scale form-fill-seal lines with 400-mm-wide seal bars exhibit sterile barrier failures when platen temperature variation exceeds ±3°C, so multi-zone heating and contact-pressure verification are required. Finished articles include die-cut lidding, chevron peel pouches, and header bags for EtO- or gamma-sterilized kits.
Infusion pump segment compounding starts from MD6041 DT at 70–90 phr and a fractional-MFR polypropylene at 10–30 phr; fully hydrogenated white mineral oil may be added at 5–20 phr to reduce hardness into the 45–55 Shore A range, but oil levels above 20 phr tend to produce surface tack and an increase in roller-clamp closure force variation. The compound is extruded on a single-screw extruder with L/D 25:1, a cooled screw core, and a crosshead tubing die at 190–210°C. Vacuum sizing calibrators hold outer diameter to ±0.05 mm, and in-line laser micrometers plus ultrasonic wall-thickness gauges monitor concentricity at 100% line speed.
On production lines, melt fracture appears at the die lip when neat resin shear rates exceed roughly 1,000 s⁻¹; the corrective action is to increase melt temperature within the allowed band or reduce line speed rather than adding external lubricant. Post-extrusion ovality increases if the cooling bath temperature drops below 12°C, because the outer wall freezes before the inner wall. Finished tubing is overmolded into injection sites and bonded to rigid polycarbonate or copolyester connectors. End-device validation follows ISO 8536-4:2019 for infusion sets, and biological evaluation follows ISO 10993-1:2018 with cytotoxicity per ISO 10993-5:2009. USP <88> Class VI data must be generated on the final compounded formulation, not only on the neat polymer, because oil and process aids alter extractables. Gamma irradiation at 25–40 kGy or ethylene oxide sterilization should be accompanied by tensile strength retention testing per ASTM D412-16; published data for this specific configuration is limited, so retention must be measured on production lots before design release.
For reusable or single-use fluid-contact components that must survive steam autoclave, MD6041 DT is compounded with 10–20 phr of a high-melt-strength polypropylene and 0.2–0.5 phr of a hindered phenolic antioxidant. Low-viscosity white oil is held below 10 phr because steam at 121°C accelerates oil migration and surface clouding after repeated cycles. Compression set is the controlling early-failure indicator; Method B of ASTM D395-18, 22 hours at 70°C, should produce values below 35% for static seals and below 25% for dynamic seals. In an injection molding cell with 100–150 t clamp force, cold-runner valve-gate tooling and mold temperature 20–40°C reduce gate blush and flow-line boundaries that can initiate crack growth. If gamma irradiation is selected, ISO 11137-1:2006 requires dose mapping for the full pallet configuration; a 25–40 kGy validation envelope is common for SEBS compounds, but dose-rate and oxygen effects must be evaluated on finished parts. Published data for this specific MD6041 DT configuration is limited, so irradiation trials should include tensile retention at 6 and 12 months after exposure.
| Sterilization mode | Typical validation envelope | Reported effect on SEBS compounds | Relevant standard |
|---|---|---|---|
| Steam autoclave | 121°C, 30 min gravity | Softening, oil migration, compression set increase after repeated cycles | ISO 17665-1:2006 |
| Gamma irradiation | 25–40 kGy | Possible chain scission or crosslinking; discoloration risk | ISO 11137-1:2006 |
| Ethylene oxide | 55°C, 3–6 h, 600 mg/L | Low thermal stress; residue levels depend on aeration | ISO 11135:2014 |
Pharmaceutical closure liners require low fragmentation, controlled penetrability, and self-sealing after needle withdrawal. Because MD6041 DT has no butadiene unsaturation, it can be formulated without sulfur, accelerators, or peroxide co-agents, removing thiuram and carbamate residues associated with conventional thermoset elastomers. A candidate injection-molded liner formulation uses 100 parts MD6041 DT, 15–25 parts fractional-MFR polypropylene, and 0.5–1.0 phr of a high-molecular-weight silicone processing aid. If lower durometer is required, a high-viscosity fully hydrogenated mineral oil may replace 5–10 parts of polymer; levels above 10 phr increase the risk of surface bloom after 70°C aging. The compound is molded on a 100–150 t clamp force machine with a cold-runner valve-gate system and mold temperature 20–35°C. Injection velocity is kept below the jetting threshold because flow lines act as crack initiation sites during needle penetration. Finished closures are tested according to ISO 8871-1:2019 for fragmentation, penetrability, and self-sealing; elastomeric closure functionality falls under USP <381>. Biological evaluation follows ISO 10993-1:2018, with cytotoxicity per ISO 10993-5:2009 and sensitization/irritation per ISO 10993-10:2010. Extractable profiling should include USP <1663> and USP <1664> for organic and elemental extractables; the finished closure, not the pellet, is the test article. Long-term aging at 70°C for 30 days should include compression set and hardness to identify oil migration before submission.
| Standard | Endpoint | Application linkage |
|---|---|---|
| ISO 10993-1:2018 | Biological evaluation planning | All patient-contacting articles |
| ISO 10993-5:2009 | In vitro cytotoxicity | Fluid path, skin contact |
| ISO 10993-10:2010 | Sensitization, irritation | Respiratory cushions, skin-contact housing |
| USP <88> Class VI | Systemic injection, intracutaneous, implantation | Fluid-contact components |
| ISO 8871-1:2019 | Closure fragmentation, penetrability, self-sealing | Pharmaceutical closures |
| ASTM F88/F88M-21 | Seal strength | Lidding and packaging |
| ISO 11607-1:2019 | Sterile barrier system requirements | Formed trays and lidding |
| ISO 11137-1:2006 | Radiation sterilization validation | Gamma-irradiated articles |
For peristaltic pump segments, the limiting property is not tensile strength but fatigue crack growth under cyclic compression. MD6041 DT is compounded with 10–20 phr of a medium-flow polypropylene and 5–15 phr of a fully hydrogenated mineral oil to balance hardness and resilience. Optimum Shore A hardness for pumping accuracy is generally 55–65; below 50 Shore A the tubing flattens and volumetric delivery drifts; above 70 Shore A pump motor torque increases and inner-surface spallation may rise. Extrusion uses a single-screw extruder with L/D 25:1 and a smooth-entry crosshead die at 190–205°C. Collapsed-tube geometry is not recommended because weld lines reduce fatigue life. In-line monitoring records outer diameter, wall thickness, and ovality; wall-thickness variation greater than ±0.03 mm creates cyclic stress concentrations. Production-scale failure modes include inner-surface particles from raceway friction and delamination when incompatible siloxane or amide slip packages are present. There is no universal ASTM standard for peristaltic pump life; OEM protocols record flow degradation over 24-hour continuous operation at defined backpressure and rotor speed. Tensile properties are measured per ASTM D412-16. Dynamic mechanical analysis at 1 Hz and 37°C can screen modulus change after flexing, but published data for this specific MD6041 DT configuration is limited, so pump life must be generated on finished tubing using the intended pump head.
Thermoformed trays from MD6041 DT blends require higher melt strength than cast film. Sheet is extruded at 205–225°C on a single-screw extruder with L/D 30:1 and polished roll stack at 25–35°C. The sheet is then fed into a contact-heat vacuum former with plug assist; draw ratios above 1.5 cause corner thinning if the sheet surface temperature is too low or plug speed too fast. For a tray with 15-mm draw depth, sheet surface temperature is held between 120°C and 135°C, but the exact window must be mapped by infrared pyrometry across the web. MD6041 DT is often blended with 20–30% polypropylene homopolymer to improve stiffness and reduce die drool; however, PP above 30% raises forming temperature and reduces thermoformability. The formed tray is used for single-use surgical kits and device packaging. After forming, edge trim is inspected for microcracks because sidewall tear propagation can occur during flexing. Sterile barrier validation follows ISO 11607-1:2019 and ISO 11607-2:2019, with seal strength per ASTM F88/F88M-21. Process capability studies record sidewall thickness at 12 points per tray; Cpk values below 1.33 usually indicate non-uniform heating rather than material variation. If static dissipative properties are required, conductive carbon black should not exceed 5 wt% because higher loadings reduce elongation and create brittle corners during trimming.
Competitive Kraton Kraton™MD SEBS MD6041 DT prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Kraton™ MD6041 DT is a linear styrene-ethylene/butylene-styrene block copolymer supplied as a dusted pellet for medical and clean-compounding operations. The DT designation denotes a pellet-partitioning morphology intended to reduce inter-pellet blocking during silo storage and dilute-phase pneumatic transfer. Grade-specific styrene content, diblock content, and melt-flow rate are defined by the current manufacturer’s technical datasheet; typical styrenic block copolymers in this medical SEBS series occupy a styrene mass fraction of 30 wt% to 33 wt%, with melt-flow values determined at 230 °C under 2.16 kg in the range of 1 g/10 min to 8 g/10 min. Batch-release documentation for Kraton medical grades is customarily generated within a quality system aligned with ISO 13485:2016, and biological evaluation planning follows ISO 10993-1:2018. This places MD6041 DT in the clean-polymer segment rather than in general-purpose SEBS supply chains, where extractables, trace-metal residues, and particulate counts are less tightly controlled.
| Assessment or Requirement | Reference Standard or Regulation |
|---|---|
| Medical device biological evaluation framework | ISO 10993-1:2018 |
| Cytotoxicity testing | ISO 10993-5:2009 |
| Sensitization testing | ISO 10993-10:2013 |
| Irritation testing | ISO 10993-23:2021 |
| Systemic toxicity evaluation | ISO 10993-11:2017 |
| Hemocompatibility evaluation | ISO 10993-4:2017 |
| Ethylene oxide residue limits | ISO 10993-7:2008 |
| Extraction study design | ISO 10993-12:2021 |
| Quality management for medical device suppliers | ISO 13485:2016 |
| European chemical regulation | REACH Regulation (EC) No 1907/2006 |
| Hazardous substances in electrical and electronic equipment | RoHS Directive 2011/65/EU |
Melt processing of MD6041 DT is conducted on corotating twin-screw extruders with 40:1 to 52:1 L/D ratios, using barrel profiles that step from 150 °C in the feed zone to 220 °C near the die. The saturated ethylene–butylene midblock provides resistance to oxidative and ultraviolet degradation not present in unsaturated SBS analogues, but it also creates a defined thermal ceiling. Prolonged residence time above 230 °C is the principal processing boundary; at these temperatures, free-radical oxidation of the midblock can increase melt viscosity, raise yellowness index, and generate odorous volatile species. On production lines equipped with vacuum vents at −0.06 MPa to −0.08 MPa, volatile ketones and aldehydes are stripped before the die. Published data for this specific configuration is limited; the manufacturer’s processing guide should be checked for grade-specific residence-time limits.
The dusted pellet morphology influences feeder behavior. Loss-in-weight feeders with vertical screw outputs exhibit dusting-agent accumulation on flight edges during campaigns exceeding 8 h. This accumulation can produce mass-flow oscillation of ±1.5 % to ±2.0 % on a 60 mm corotating extruder when no purge is applied. Production-scale handling therefore uses clean dry air at 0.5 bar to 1.0 bar for periodic feeder purges and keeps hopper fill below 60 % to reduce dust stratification. The material is not considered hygroscopic; pre-drying is not routinely required unless bags have been opened in environments above 60 % relative humidity, where trace surface moisture can generate steam and surface defects in extruded tubing.
Chemical incompatibilities include aromatic and chlorinated solvents, strong mineral acids, and prolonged contact with high-peroxide mineral oils. Amine-based antidegradants are generally not required for the saturated midblock and should be avoided where low extractables are required because certain amine stabilizers can appear as organic extractables in cytotoxicity and sensitization testing. Medical compounds built on MD6041 DT should therefore use phenolic/phosphite stabilizer packages that have been pre-screened under ISO 10993-5:2009 for direct and indirect wound-contact devices.
When MD6041 DT is used as an impact modifier or soft-phase donor in polypropylene-rich formulations, the phase-inversion point and dispersed-phase size determine the balance of toughness and clarity. On a corotating twin-screw extruder with 40:1 L/D and segmented screw geometry, dispersive mixing is generated by kneading blocks positioned in barrel zones 5 and 6. A screw profile with 30 % to 40 % of kneading elements relative to total screw length typically yields an SEBS domain size below 2.0 µm when the viscosity ratio between the SEBS melt and polypropylene melt remains between 0.5 and 2.0 at the local shear rate. Specific mechanical energy inputs of 0.18 kWh/kg to 0.25 kWh/kg are representative for producing translucent impact-modified polypropylene compounds without mineral oil dilution. If the specific energy falls below 0.12 kWh/kg, undispersed SEBS agglomerates persist as gel-like specks in cast film; above 0.28 kWh/kg, melt-temperature overshoot can exceed 230 °C and initiate degradation.
On field-scale equipment, batch-to-batch variance in pellet dusting level affects the first barrel-fill ratio. A dusting-level variation from 0.05 wt% to 0.15 wt% is sometimes observed across production campaigns; at the upper bound, feeding efficiency can drop if the feeder screw becomes coated. Operators maintain consistent intake by adjusting screw speed rather than raising barrel temperature, because a 5 °C increase in the feed zone can soften the dusted pellet surface and promote sticking. Published data for MD6041 DT dusting level is limited; users should request certificate-of-analysis values for ash and dusting concentration when implementing automated feeding systems.
MD6041 DT is specified for flexible medical tubing, blow-fill-seal containers, respiratory bags, and coextruded films where the final device must pass systemic injection, intracutaneous, and implantation tests. In single-layer extruded tubing, melt pumps are used after the screw tip to reduce pressure pulsation to ±0.2 MPa; wall-thickness control is maintained with laser gauge feedback at 24.0 kHz to 48.0 kHz sampling rates. Tubing lines running 10 mm to 25 mm outside diameter generally operate at line speeds of 15 m/min to 45 m/min, depending on the collapse plate and vacuum sizing tank design. The fully saturated midblock permits heat-set dimensional stability after annealing at 105 °C for 2 h, although post-annealing shrinkage is formulation-dependent.
For blow-fill-seal processing, the polymer’s low extractables and absence of intentionally added phthalate plasticizers are critical. The parison melt temperature is maintained at 190 °C to 215 °C; die swell increases when melt temperature drops below 185 °C, causing parison length instability. Medical blow-fill-seal equipment operating with clamp force ratings up to 250 kN and fill volumes of 0.5 mL to 5.0 mL requires consistent melt index within 0.5 g/10 min from lot to lot to avoid wall-thickness variation in ampoule bodies.
In coextruded film, MD6041 DT is combined with polyethylene or polypropylene skin layers. The melt-viscosity ratio at the die lips must be controlled because interfacial instability results when the viscosity ratio exceeds 3:1. Film property measurements follow ISO 527-3:2018 for tensile properties of film and ASTM D1003-21 for haze and luminous transmittance. The material’s saturated midblock provides better long-term clarity retention under fluorescent lighting than butadiene-based styrenic block copolymers, although grade-specific weathering data should be obtained for products exposed beyond 30 days of continuous illumination.
MD6041 DT is designed to be compatible with ethylene oxide, gamma radiation, and moist-heat sterilization, but the selection is not neutral with respect to property retention. Ethylene oxide sterilization under ISO 11135:2014 typically exposes devices to 600 mg/L to 800 mg/L EtO at 50 °C to 60 °C for 2 h to 4 h, followed by aeration. Residual EtO must be reduced below limits specified in ISO 10993-7:2008; because SEBS has low polarity, aeration time depends on wall thickness and packaging density more than polymer composition. Gamma irradiation at 25 kGy to 50 kGy may cause measurable yellowing and tensile loss in SEBS; published data for MD6041 DT at doses above 50 kGy is limited. Where radiation tolerance is required, the formulated compound should include radiation stabilizers tested for extractables before final device qualification.
Autoclave sterilization at 121 °C for 30 min under ISO 17665-1:2006 is generally less aggressive to the polymer backbone than gamma irradiation but can induce dimensional change in oriented tubing. Tubing annealed at 105 °C before autoclave exposure shows lower shrinkage than as-extruded tubing. Repeated autoclave cycles may consume part of the phenolic stabilizer package; after 50 cycles, some SEBS formulations show a drop in elongation at break of 10 % to 20 % relative to unsterilized controls. Grade-specific data for MD6041 DT should be obtained according to ISO 37:2017 using Type 2 dumbbell specimens, because generic SEBS data cannot be transferred across molecular weights and oil loadings.
Compared with non-medical SEBS grades, MD6041 DT differs primarily in the control of leachables, trace metals, and batch-release documentation. General-purpose SEBS products may be produced without medical-grade certificate requirements and may contain higher catalyst residues or branched structures that affect cytotoxicity. Relative to oil-extended SEBS, MD6041 DT does not require mineral oil to achieve processability for thin-wall tubing; this absence of mineral oil is relevant for reducing lipid-soluble extractables in infusion devices. The saturated midblock distinguishes it from unsaturated SBS grades, which require antioxidant packages to delay ozone cracking and are not generally used for long-term implantable devices.
In the melt state, MD6041 DT behaves as a pseudoplastic triblock melt with a low-shear Newtonian plateau. Capillary rheometry at 200 °C over apparent shear rates from 10 s⁻¹ to 1000 s⁻¹ is used to estimate process consistency. Because the grade is unfilled and not oil-extended, its complex viscosity at 0.1 rad/s is typically higher than oil-extended SEBS of similar hardness, which affects layer stability in coextrusion. Melt-flow values alone do not predict die-lip behavior; viscosity-shear-rate curves should be obtained under ISO 11443:2021 before tooling changes.
A processing boundary relevant to tubing assembly is solvent bonding. SEBS is softened or stress-crazed by cyclohexanone and methylene chloride; solvent-bonding protocols validated for PVC cannot be transferred to SEBS without re-qualification. Alternative joining methods include radio-frequency welding, ultrasonic welding at 20 kHz, and insert molding. Ultrasonic welders with amplitude of 35 µm to 45 µm, force of 200 N to 350 N, and weld times of 0.3 s to 0.6 s have been reported for SEBS tubing, but exact settings require geometry-specific validation.
For medical device manufacturers, the material’s extractables profile must be evaluated in the finished device, not in the pellet. Aqueous and lipid extraction studies are conducted according to ISO 10993-12:2021 with extraction ratios of 3 cm²/mL or 6 cm²/mL depending on geometry. Extractables from SEBS are generally dominated by fatty acids, sterically hindered phenolic antioxidants, and low-molecular-weight polymer fractions when polar solvents are used; published data for this specific configuration is limited and should not substitute for end-use extractables testing.