| HS Code | 412561 |
| Density | 1.31 g/cm³ |
| Water Absorption | 0.08 % |
| Tensile Strength | 55 MPa |
| Elongation At Break | 50 % |
| Flexural Modulus | 2400 MPa |
| Flexural Strength | 85 MPa |
| Notched Izod Impact Strength | 40 J/m |
| Heat Deflection Temperature At 1 82 Mpa | 65 °C |
| Melting Point | 225 °C |
| Mold Shrinkage | 1.5–2.0 % |
| Volume Resistivity | >1.0E16 Ω·cm |
| Dielectric Strength | 20 kV/mm |
| Dielectric Constant At 1 Mhz | 3.2 |
| Ul Flammability Rating | HB |
| Processing Melt Temperature | 240–260 °C |
| Mold Temperature | 60–80 °C |
As an accredited Korea Engineering Plastics KEPEX® PBT Unfilled 3300M factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | KEPEX® PBT Unfilled 3300M is supplied in 25 kg moisture-barrier bags, palletized for industrial handling and storage. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with Korea Engineering Plastics KEPEX® PBT Unfilled 3300M, in 25kg bags, palletized and secured for export. |
| Shipping | Typically shipped as non-hazardous PBT resin pellets in 25 kg moisture-barrier bags, palletized and stretch-wrapped. Use dry, ventilated containers and protect from moisture, heat, and direct sunlight. Store in a cool, dry warehouse; no special hazardous cargo requirements. |
| Storage | Store in a cool, dry, well-ventilated area away from direct sunlight, heat sources, and moisture. Keep containers tightly closed and use original packaging to prevent contamination and moisture pickup. Avoid contact with strong oxidizers, acids, and bases. Maintain good housekeeping and keep away from ignition sources. Dry according to supplier recommendations before processing. |
| Shelf Life | Korea Engineering Plastics KEPEX® PBT Unfilled 3300M typically has a 24-month shelf life in original unopened packaging under cool, dry conditions. |
Competitive Korea Engineering Plastics KEPEX® PBT Unfilled 3300M prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Korea Engineering Plastics KEPEX® PBT Unfilled 3300M is a medium-viscosity, unreinforced polybutylene terephthalate injection-molding compound supplied in pellet form. The 3300M designation identifies the grade within the unfilled KEPEX PBT series and distinguishes it from glass-fiber-reinforced, flame-retardant, and impact-modified KEPEX PBT materials. Applications for 3300M are concentrated in thin-wall electrical and electronic components in which anisotropic shrinkage, fiber-induced warpage, and surface appearance effects from glass reinforcement are not acceptable. Representative data described below are obtained from injection-molded specimens prepared under ISO 294-1 and conditioned at 23 °C/50 % RH; they are typical values rather than lot-specific specification limits. Published data for lot-specific behavior are available from Korea Engineering Plastics, and end-product qualification remains required for each application.
The following representative property profile defines the unfilled 3300M grade as a moderately stiff, electrically insulating polyester with medium flow capability. Exact lot values may vary with pellet moisture, injection-molding parameters, and conditioning history.
| Property | Test method | Representative value |
|---|---|---|
| Density | ISO 1183-1 | 1.31 g/cm³ |
| Melt volume-flow rate at 250 °C/2.16 kg | ISO 1133-1 | 15 cm³/10 min |
| Tensile stress at yield, 50 mm/min | ISO 527-2 | 55 MPa |
| Tensile strain at yield | ISO 527-2 | 3.5 % |
| Flexural modulus, 23 °C | ISO 178 | 2,500 MPa |
| Charpy notched impact strength, 23 °C | ISO 179-1/1eA | 4.5 kJ/m² |
| Heat deflection temperature, 1.80 MPa | ISO 75-2/Af | 60 °C |
| Coefficient of linear thermal expansion, 23–55 °C | ISO 11359-2 | 100 × 10⁻⁶ K⁻¹ |
| Volume resistivity | IEC 62631-3-1 | >1 × 10¹³ Ω·m |
| Dielectric strength, 1 mm | IEC 60243-1 | 20 kV/mm |
| Comparative tracking index | IEC 60112 | 600 V |
| Flammability rating, 0.8 mm | UL 94 | HB |
These data place 3300M in the moderately stiff, electrically insulating portion of the PBT spectrum. The melt volume-flow rate of 15 cm³/10 min at 250 °C/2.16 kg is specifically suited to filling wall sections below 0.5 mm in connector bodies, relay bobbins, and motor brush holders without excessive injection pressure. The heat deflection temperature of 60 °C at 1.80 MPa indicates that the unfilled grade is not a direct substitute for glass-reinforced PBT in load-bearing hot areas; instead it is selected where electrical insulation and dimensional consistency outweigh rigidity.
Before melt processing, 3300M pellets must be dried in a dehumidifying hopper dryer at 120 °C for 4–6 h to a maximum moisture content of 0.02 %. Dryer dew point should be maintained at or below −30 °C. Regrind with increased surface area may require an additional 1–2 h of drying. In production-scale thin-wall molding, moisture contents above 0.05 % produce hydrolytic chain scission during plastication, visible as splay and silver streaks on part surfaces and measurable as reduced melt viscosity and Charpy impact. Hydrolysis is accelerated above 260 °C; barrel residence time at melt temperature should be limited to 5 min or less. Extended residence or hot spots above 270 °C promote tetrahydrofuran evolution, yellowing, and molecular weight loss even in pre-dried material.
Melt temperature should be set between 240 °C and 260 °C, with the nozzle at 250–260 °C. Injection units should use a general-purpose screw with an L/D ratio of 20:1 and compression ratio of 2.5:1; low-return-valve clearances are required because unfilled PBT exhibits a steep viscosity-temperature response. Mold temperature should be held at 40–80 °C. At 40 °C, cycle time is minimized but post-mold shrinkage increases; at 80 °C, dimensional stability improves at the cost of longer cooling time. Typical starting parameters for screw diameters between 25 mm and 60 mm are screw surface speed of 0.2–0.4 m/s and back pressure of 2–5 MPa. Injection speed should be moderate to fast, with hold pressure set to 50–70 % of peak injection pressure and cushion maintained at 2–4 mm. Vent depth of 0.015–0.025 mm is required to avoid burning at the flow front. Hot-runner manifold temperatures above 265 °C create a thermal degradation risk in stagnant zones and should be avoided unless validated by short-shot and molecular weight testing. Production experience with unfilled PBT shows that screw-recovery time can become a cycle-time bottleneck when shot volume exceeds 60 % of barrel capacity because shear heating must be balanced against shorter recovery intervals.
Unfilled PBT melts exhibit shear-thinning behavior. At 250 °C, apparent viscosity typically spans 100–300 Pa·s at 100 s⁻¹ and 30–60 Pa·s at 1000 s⁻¹. This shear sensitivity supports thin-wall filling, but undersized runners and high screw speeds can generate local melt temperatures above 280 °C. Mold-filling simulations should use pressure-dependent PVT data, and cavity pressure sensors are recommended when wall sections are below 0.4 mm to distinguish short shots from flow-front hesitation caused by gas entrapment.
The unfilled 3300M grade is preferred when weld-line strength, low warpage, and stable electrical properties are more important than flexural rigidity. Glass-fiber-reinforced KEPEX PBT products provide flexural modulus from 8,000 MPa to 10,000 MPa and heat deflection above 200 °C, but they introduce anisotropic shrinkage, visible fiber effects, and lower unreinforced elongation. Flame-retardant KEPEX PBT grades provide UL 94 V-0 performance at thin sections but often operate within narrower processing windows and can generate mold deposit formation from phosphorus-based flame-retardant additives. Impact-modified KEPEX PBT products raise notched impact values above 10 kJ/m² but sacrifice modulus and may reduce chemical resistance. 3300M is therefore positioned for thin-wall connector housings, sensor bodies, relay bobbins, brush holders, and switch components requiring low moisture absorption and consistent shrinkage without glass or halogenated flame retardants.
| Performance dimension | 3300M unfilled | 30% glass-reinforced KEPEX PBT | Flame-retardant KEPEX PBT | Impact-modified KEPEX PBT |
|---|---|---|---|---|
| Flexural modulus, ISO 178 | 2,500 MPa | 8,000–10,000 MPa | 2,600–3,200 MPa | 1,800–2,400 MPa |
| Tensile stress at yield, ISO 527-2 | 55 MPa | 130 MPa | 55–65 MPa | 40–50 MPa |
| HDT at 1.80 MPa, ISO 75-2/Af | 60 °C | 200 °C | 65–80 °C | 55–60 °C |
| Charpy notched impact, ISO 179-1/1eA | 4.5 kJ/m² | 8 kJ/m² | 3 kJ/m² | 10–20 kJ/m² |
| Wall-thickness rating, UL 94 | HB at 0.8 mm | HB at 0.8 mm | V-0 at 0.8 mm | HB at 0.8 mm |
The table indicates comparative family behavior. Individual KEPEX grade datasheets must be referenced for exact values because formulation choices alter flow, impact, and electrical behavior. Mold shrinkage of unfilled 3300M is typically 1.6–2.0 % in the flow direction and 1.8–2.2 % in the transverse direction for a 2 mm plaque molded at 60 °C; this near-isotropic shrinkage behavior is a principal reason for selecting the unfilled grade over glass-reinforced alternatives in flat parts with tight dimensional tolerances.
Parts molded from 3300M are typically qualified under IEC 60664-1 insulation coordination, with comparative tracking index classified at 600 V per IEC 60112 and volume resistivity above 1 × 1013 Ω·m per IEC 62631-3-1. This grade is therefore used in low-voltage connectors, relay bobbins, and switch components where incidental moisture and moderate pollution are expected. The operational boundary for hydrolytic exposure is 60 °C continuous immersion or high-pressure hot water; above this, tensile strength loss can exceed 30 % after several hundred hours depending on part thickness and water chemistry, though published data for this specific grade in continuous hot-water aging are limited. Qualification under IEC 60068-2-78 damp heat is required for critical electrical clearances after aging.
Chemical compatibility of unfilled PBT 3300M covers aliphatic hydrocarbons, gasoline, diesel fuel, oils, alcohols, ethers, and many weak acids and bases at ambient temperature. Strong mineral acids, strong caustic solutions, ketone-rich solvents, and chlorinated hydrocarbons are not recommended because they can produce surface attack or environmental stress cracking. In automotive underhood systems involving hot glycol-water mixtures above 100 °C, hydrolysis resistance must be validated on the molded part under actual thermal cycling and pressure conditions. Regrind usage in noncritical electrical components is typically limited to 20–25 wt% unless the molder confirms retention of ISO 179-1/1eA impact and IEC 60112 tracking index after aging.