| HS Code | 614998 |
| Polymer Base | Polybutylene terephthalate (PBT) |
| Glass Fiber Content | 30% |
| Flame Retardant | Yes |
| Toughened | Yes |
| Processing Method | Injection molding |
| Density | Approximately 1.55–1.65 g/cm³ |
| Molding Shrinkage | Approximately 0.2–0.5% |
| Tensile Strength | Approximately 110–130 MPa |
| Flexural Modulus | Approximately 8,000–9,500 MPa |
| Elongation At Break | Approximately 2–3% |
| Notched Impact Strength | Approximately 7–10 kJ/m² |
| Heat Deflection Temperature | Approximately 195–210 °C at 1.8 MPa |
| Flammability Rating | UL 94 V-0 (typical) |
| Volume Resistivity | Typical >1E15 Ω·cm |
| Water Absorption | Approximately 0.05–0.08% |
As an accredited Korea Engineering Plastics KEPEX® PBT+GF30%-FR-T 3330GVT factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Korea Engineering Plastics KEPEX® PBT+GF30%-FR-T 3330GVT is supplied in 25 kg moisture-proof bags, 40 bags per pallet (1,000 kg net). |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): KEPEX® PBT+GF30%-FR-T 3330GVT is transported in a 20′ FCL container, palletized in original packaging and secured for safe shipment. |
| Shipping | KEPEX® PBT+GF30%-FR-T 3330GVT is a non-hazardous, flame-retardant, 30% glass-fiber-reinforced PBT molding compound. It is not regulated for transport under DOT/IMDG/IATA in solid form. Ship in original sealed moisture-barrier bags or drums, keep dry, avoid direct sunlight, and protect from extreme temperatures. |
| Storage | Store KEPEX® PBT+GF30%-FR-T 3330GVT in a cool, dry, well-ventilated area, away from direct sunlight, heat, ignition sources, and moisture. Keep in original, sealed packaging until use; protect from UV, dust, and static. Avoid prolonged storage above recommended temperatures and contact with strong oxidizers or acids. Maintain good housekeeping, local exhaust ventilation, and follow supplier SDS and local regulations. |
| Shelf Life | Store in a cool, dry place in unopened packaging; typical shelf life is 12 months from date of manufacture. |
Competitive Korea Engineering Plastics KEPEX® PBT+GF30%-FR-T 3330GVT prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Korea Engineering Plastics KEPEX® PBT+GF30%-FR-T 3330GVT is a polybutylene terephthalate injection-moulding compound containing 30 wt% glass-fibre reinforcement and a flame-retardant package designated FR-T. The pelletized grade is specified for dimensionally stable electrical, electronic, and underhood components in which thin-wall flame retardancy, short-term heat resistance, and mechanical stiffness are required simultaneously. Representative values obtained from producer technical literature and standard laboratory methods include a density of 1.60 g/cm³ to 1.65 g/cm³ when tested to ISO 1183-1, and a melt volume-flow rate of 18 cm³/10 min to 24 cm³/10 min at 250 °C under 2.16 kg when tested to ISO 1133-1:2022. The 30 wt% glass fibre raises flexural modulus into the 8,500 MPa to 10,000 MPa range and reduces flow-direction mould shrinkage to below 0.6 %, which differentiates the grade from unfilled flame-retardant PBT and lower-glass PBT compounds.
Table 1 compares representative physical, mechanical, thermal, and flammability values for 3330GVT with lower-glass and unfilled PBT-based grades. The data are typical producer values and are not lot-specific specifications.
| Property | 3330GVT | PBT-GF15 FR | Unfilled PBT FR | PBT-GF30 non-FR | Test standard |
|---|---|---|---|---|---|
| Density | 1.60–1.65 g/cm³ | 1.48–1.52 g/cm³ | 1.42–1.48 g/cm³ | 1.52–1.58 g/cm³ | ISO 1183-1 |
| Tensile strength at break | 120–140 MPa | 100–120 MPa | 55–65 MPa | 130–150 MPa | ISO 527-2 |
| Flexural modulus | 8,500–10,000 MPa | 5,500–6,500 MPa | 2,500–3,000 MPa | 8,000–9,500 MPa | ISO 178 |
| Heat deflection temperature, 1.82 MPa | 200–210 °C | 190–200 °C | 80–90 °C | 200–210 °C | ISO 75-2/Af |
| Mould shrinkage, flow direction | 0.3–0.5 % | 0.5–0.8 % | 1.8–2.0 % | 0.3–0.5 % | ISO 294-4 |
| Flame rating | V-0 at 0.8 mm and 1.6 mm | V-0 at 0.8 mm | V-0 at 0.8 mm | HB | UL 94 |
Flame classification of 3330GVT is controlled by the interaction between glass-fibre wicking, char formation, and moulded-in stress. At 0.8 mm and 1.6 mm, natural and black lots are typically rated V-0 when tested in accordance with UL 94; published data for this specific configuration is limited at 0.4 mm, and sub-0.5 mm designs require end-product qualification. Glass fibres can promote surface flame propagation by capillary wicking if the flame-retardant package is insufficiently coupled to the resin matrix; in 3330GVT the FR-T system is formulated so that V-0 is retained at 0.8 mm while the melt volume-flow rate remains at or above 18 cm³/10 min. Thicker sections may show slightly longer afterglow because the heat-sink effect of glass lowers surface temperature rise. Glow-wire flammability index measured to IEC 60695-2-12 on 1.0 mm plaques is commonly reported at 960 °C, and comparative tracking index to IEC 60112 is 250 V to 300 V. Moulded-in stress, pigment type, and regrind content can shift tracking resistance downward, so end-use testing is required for creepage-sensitive designs. The grade is not recommended for continuous exposure to hot aqueous glycol above 80 °C or strong alkaline solutions because PBT undergoes hydrolytic degradation; conditioning according to ISO 175 and subsequent tensile testing to ISO 527-2 are advised for such environments.
Reported compliance and classification data for 3330GVT are given in Table 2. Chemical regulatory status must be confirmed with the supplier for the specific colour and lot because flame-retardant additives may require declarable-substance reporting.
| Assessment | Reported classification/range | Reference method |
|---|---|---|
| Flame rating | V-0 at 0.8 mm and 1.6 mm | UL 94 |
| Glow-wire flammability index | 960 °C at 1.0 mm | IEC 60695-2-12 |
| Comparative tracking index | 250 V to 300 V | IEC 60112 |
| Melt volume-flow rate | 18 cm³/10 min to 24 cm³/10 min at 250 °C/2.16 kg | ISO 1133-1:2022 |
| Density | 1.60 g/cm³ to 1.65 g/cm³ | ISO 1183-1 |
| RoHS restricted substances | Supplier lot certificate required | 2011/65/EU Annex II |
In connector, relay, circuit-breaker, and switch applications, 3330GVT is processed into parts where wall thickness remains below 2.0 mm and the part must withstand soldering or reflow thermal excursions. The glass reinforcement reduces post-mould warpage in multi-pin connectors but creates anisotropic shrinkage; flow-direction shrinkage is typically 0.3 % to 0.5 %, while transverse shrinkage is 0.7 % to 1.0 %. Gate placement at the centre of long connector bodies is used to orient fibre flow parallel to the pin row. On 1,200 kN toggle-clamp injection moulding machines, hold-pressure settings of 500 bar to 800 bar for 3 s to 5 s reduce sink marks in bosses up to 30 % of wall thickness. For relay bases and bobbin flanges, mould temperature is held at 90 °C to 100 °C to improve crystallinity and reduce post-mould dimensional movement after annealing at 120 °C for 2 h. The FR-T package permits thin-wall V-0, but mould deposit build-up can be greater in long-flow tools; vent cleaning intervals of 20,000 to 50,000 shots are common for similar PBT-GF30 FR compounds. In power distribution components, the CTI range of 250 V to 300 V is acceptable for many appliance connectors but may require increased creepage distance when pollution degree 3 or 600 V working voltage applies; creepage clearance must be calculated to IEC 60664-1.
Moisture control is process-critical for 3330GVT. The compound is dried at 120 °C to 130 °C for 3 h to 5 h in a desiccant dryer with a dew point at or below -30 °C, reducing residual moisture to 0.02 wt% or lower as measured to ISO 15512. At relative humidity above 60 %, hopper residence without dry-air purge should not exceed 1 h; surface moisture re-absorption can produce splay and reduce molecular weight during plastication. Barrel temperature profile from feed throat to nozzle is typically 240 °C, 250 °C, 260 °C, and 260 °C. Melt temperature is maintained between 250 °C and 270 °C; nozzle temperature is set at 250 °C to 260 °C. Above 280 °C, PBT degrades rapidly and the flame-retardant package can release corrosive halogen acids, so nozzle thermocouple verification is performed at start-up and after material changes.
For hot-runner tools, manifold temperature should track melt temperature within ±5 °C, and total hot-runner residence time should be kept below 10 min. In sequential valve-gated multi-cavity tools, flow imbalance may create longer residence time in some channels; thermal gate shutoff and periodic purging reduce black-speck formation and flame-rating drift. Mould surface temperature is controlled between 60 °C and 100 °C. At mould temperatures below 60 °C, thin-wall sections can freeze before packing, producing sink marks and low crystallinity; above 100 °C, cycle time increases and low-molecular-weight FR additive bloom can deposit on mould surfaces. A mould temperature of 80 °C to 90 °C is commonly specified for parts requiring good surface appearance. Screw speed during recovery is set below 0.3 m/s, and back pressure is maintained between 5 bar and 20 bar to limit glass-fibre attrition. General-purpose screws with a compression ratio of 2.0:1 to 2.5:1 and check-ring clearance of 0.05 mm to 0.10 mm are acceptable. Regrind usage should be limited to 20 wt% for thin-wall flame-rated parts because repeated heat cycles can lower CTI and shift UL 94 afterglow performance.
Compared with PBT-GF15 FR, 3330GVT raises tensile modulus from approximately 6,500–7,500 MPa to 9,500–11,000 MPa and flexural modulus from 5,500–6,500 MPa to 8,500–10,000 MPa, both measured to ISO 527-2 and ISO 178 respectively. This increase permits thinner wall sections to carry equivalent bending load but also increases melt viscosity and can reduce weld-line strength in complex geometries. The higher glass fraction lowers flow-direction mould shrinkage from 0.5–0.8 % to 0.3–0.5 %; transverse shrinkage remains at 0.7–1.0 %. A tool designed for PBT-GF15 FR may therefore generate greater differential warpage unless gate locations are revised for the higher-glass grade.
Against unfilled flame-retardant PBT, 3330GVT increases heat deflection temperature at 1.82 MPa from approximately 80 °C to 200–210 °C when tested to ISO 75-2/Af. This allows short-term exposure to reflow soldering temperatures; however, elongation at break decreases from approximately 3–5 % for unfilled PBT to 2–3 % for 3330GVT. Snap-fit features must therefore be reviewed for brittle fracture at sharp corners with radii below 0.5 mm. Compared with non-flame-retardant PBT-GF30, the FR-T package typically reduces notched Izod impact strength from 9–11 kJ/m² to 7–9 kJ/m² when tested to ISO 180/1A, and may reduce CTI. When replacing a non-FR PBT-GF30 in an existing tool, purging intervals should be shortened because FR additive bloom and mould deposits can increase.
Relative to PA66-GF30 FR, 3330GVT shows lower moisture absorption—typically 0.15–0.25 % at 23 °C and 50 % RH compared with 1.0–1.2 % for PA66-GF30—which provides better dimensional stability in humid environments. PA66-GF30 FR generally offers higher load-bearing capacity after moisture conditioning and better weld-line strength, while 3330GVT offers more stable electrical properties in high-humidity service. Selection between the two grades depends on whether the application prioritises moisture resistance and electrical stability or elevated-temperature load-bearing behaviour after conditioning.