| HS Code | 921150 |
| Material Type | Acrylonitrile Butadiene Styrene (ABS), flame retardant |
| Flame Retardant | Yes |
| Ul94 Rating | V-0 |
As an accredited Jiangsu Xinfuda ABS H1100 H FR factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Typically supplied in 25 kg moisture-proof woven bags, palletized and shrink-wrapped for secure transport and storage. |
| Container Loading (20′ FCL) | Jiangsu Xinfuda ABS H1100 H FR is loaded into a 20-foot FCL container, palletized and secured for safe overseas transport. |
| Shipping | Jiangsu Xinfuda ABS H1100 H FR is normally shipped as non-hazardous general cargo in 25 kg bags or bulk containers. No UN number or transport hazard class is expected. Keep dry, cool, and ventilated; protect from moisture, heat, sunlight, and contamination. Verify the SDS and local regulations before transport. |
| Storage | Store in a cool, dry, well-ventilated area away from direct sunlight, heat, and ignition sources. Keep containers sealed to prevent moisture and dust contamination. Avoid contact with strong oxidizers and acids. Use grounding to prevent static buildup, and follow local regulations and the manufacturer’s SDS. |
| Shelf Life | Jiangsu Xinfuda ABS H1100 H FR typically has a 24-month shelf life when stored dry, cool, and in unopened original packaging. |
Specified for indoor fibre-optic network termination units and rack-mounted switch bezels where service access is restricted but fire enclosure integrity is mandated by IEC 62368-1:2023, Jiangsu Xinfuda ABS H1100 H FR is processed with a moisture target below 0.06 % by weight. The as-supplied pellets are dried in a desiccant dryer with a dew point of −30 °C for 3–4 h at 80 °C. Barrel set points run from 210 °C in the feed zone to 230 °C at the nozzle, while the tool surface is controlled between 45 °C and 65 °C to reduce surface splay without sacrificing weld-line impact. Production parts are checked against UL 94 V-0 at the minimum wall thickness stated on the approved yellow card, commonly 1.5 mm or 3.0 mm for flame-retardant ABS of this class. Enclosure bosses, snap-fit features, and vent slots are designed with a nominal wall of 2.0–2.5 mm to avoid sink marks that reduce the effective fire barrier under post-mold shrinkage. Terminal applications include indoor optical network terminal housings, small-core switch front bezels, and modular patch-panel frames. Moulding trials report that a regrind ratio above 25 % can increase lot-to-lot variation in flame-retardant distribution at thin ribs and should be validated by glow-wire testing per IEC 60695-2-11 on each regrind batch if the part is used in unattended equipment. The material is not recommended for outdoor installation without an additional UV-stabilized cap layer because brominated flame-retardant systems in ABS can exhibit surface yellowing after 600–1,000 h of exposure under ISO 4892-2 conditions.
Indoor portable charging control box enclosures are evaluated under IEC 61851-1, and the enclosure is typically subjected to glow-wire tests at 850 °C per IEC 60695-2-11 when the part carries current above 0.2 A in unattended service. At a nominal wall of 1.6 mm, flame extinction is not determined solely by the base resin; it is controlled by gating, knit-line orientation, and heat history through the screw. A direct edge gate of 1.4 mm diameter can create a frozen-layer orientation that allows flame propagation along the flow front, while a fan gate with 0.8–1.0 mm land reduces shear heating and preserves distribution of the flame-retardant package. The injection phase is set at 70–90 MPa hydraulic pressure with a holding time of 6–10 s, and the tool is held at 50–60 °C to avoid surface blush on textured regions. Published data for ABS H1100 H FR at 1.6 mm under production tooling is limited; validation on the final tool is mandatory because UL yellow card thickness alone does not guarantee glow-wire compliance in a finished enclosure. Terminal parts include Mode 2 portable charging control boxes used indoors, where the housing must also resist mechanical impact from cable strain and occasional thermal cycling between −10 °C and 60 °C. The material should not be specified for outdoor coupler shells exposed to road splash, ultraviolet radiation, or sub-zero impact without a complete redesign of wall thickness and UV stabilization package.
Low-voltage assembly covers, busbar shrouds, and circuit breaker cover plates produced from flame-retardant ABS are evaluated under IEC 61439-1 for resistance to abnormal heat. The ball-pressure test of IEC 60695-10-2 applies a 5 mm steel ball to the finished part at 125 °C for 1 h; the indentation diameter must not exceed 2.0 mm. This test is distinct from the UL 94 fire test because it measures softening under simultaneous thermal load and surface stress. Moulded sections below 2.0 mm can pass the glow-wire sequence yet fail ball-pressure if the packing phases are too short to eliminate internal voids around the boss and rib intersections. Cover plates are typically moulded at 2.5–3.2 mm nominal wall, with a packing pressure of 50–70 MPa and a cooling time of 18–25 s for a shot weight under 300 g. The following matrix lists the typical acceptance criteria applied to flame-retardant ABS in this switchgear application.
| Test | Standard | Typical acceptance criterion |
|---|---|---|
| Flammability | IEC 60695-11-10 / UL 94 | V-0 at 1.5 mm or 3.0 mm |
| Glow-wire flammability index | IEC 60695-2-12 | GWFI 960 °C at 2.0 mm |
| Glow-wire ignition temperature | IEC 60695-2-13 | GWIT 850 °C at 2.0 mm |
| Ball pressure | IEC 60695-10-2 | ≤ 2.0 mm impression at 125 °C |
| Comparative tracking index | IEC 60112 | ≥ 250 V for live-part segregation |
Comparative tracking index is a limiting factor when the flame-retardant package contains halogenated species. If the measured CTI falls below 250 V, creepage distances required by IEC 60664-1 must be increased, which alters the dimensional envelope of the cover plate and may force a wider busbar spacing. Terminal products include moulded terminal shrouds, busbar support frames, and front cover plates for distribution boards operating at 230/400 V. Parts that will remain in service above 90 % RH for extended periods should be checked for surface leakage current after damp heat conditioning per IEC 60068-2-78, because condensed moisture can combine with halogenated flame-retardant degradation products at the surface and reduce tracking resistance. Published data for H1100 H FR under combined damp heat and electrical load is limited; this configuration requires end-product testing on the actual cover geometry.
In electromedical enclosures that are neither patient-applied parts nor subjected to repeated autoclave sterilization, flame-retardant ABS is used for diagnostic cart housings, monitor bezels, and control panel frames. The moulding is assessed for fire enclosure requirements within the risk-management framework of IEC 60601-1:2005 + A1:2021, but the material supplier does not independently provide medical device certification. Resistance to cleaning agents is relevant because hospital surfaces are wiped with quaternary ammonium compounds and diluted isopropyl alcohol. Quaternary ammonium solutions at 0.1–0.5 % active concentration can initiate environmental stress cracking if the moulded part has high gate stress or sharp internal corners. The tool should therefore be designed with a minimum radius of 0.8 mm at all ribs and bosses. Flame-retardant ABS of this class is not suitable for oxygen-enriched atmospheres or nitrous oxide exposure, and no claim is made for biocompatibility under ISO 10993-5 for enclosure materials. The processing window is narrower than unreinforced ABS because the brominated flame-retardant package degrades at high barrel residence time. Screw recovery should be maintained between 2 s and 5 s for shot weights below 200 g. Terminal products include portable vital-signs monitor housings, ultrasound cart cable-management covers, and diagnostic workstation bezels used in controlled indoor environments.
Control panels in washing machines, dishwashers, and refrigerator dispenser bezels are designed to keep creepage and clearance distances stable after the mechanical abuse tests of IEC 60335-1. The flame-retardant ABS is moulded into panels with a length of 250–350 mm, and shrinkage anisotropy is significant. Linear mould shrinkage in the flow direction is typically 0.4–0.7 %, while transverse shrinkage is 0.5–0.8 % under ISO 294-4 after 24 h. A differential of 0.2 % can produce 0.6–1.5 mm of bow across a 300 mm panel after 48 h at 85 % RH. The tool must therefore use segregated cooling circuits with a mould surface temperature differential no greater than 5 °C between the cavity and the core. Creepage distances are audited after conditioning in 70 °C damp heat for 96 h because flame-retardant ABS can undergo post-moulding dimensional relaxation at elevated humidity. Panels are annealed at 70–80 °C for 2 h before secondary operations such as pad printing or laser marking; this reduces stress concentration around switch apertures. External plasticizer migration from PVC wire insulation can cause localized whitening at contact points, so grommets or cable ties made from polyamide should isolate the wire from the ABS panel over long-term service. Terminal products include washing machine control facias, dishwasher front panel inserts, and refrigerator dispenser bezels. The material is not recommended for panels in direct contact with ester-based cooling fluids or amine-based cleaning agents, because these chemical families can accelerate stress cracking at injection-welded knit lines.
This processing conflict is observed on 24:1 L/D general-purpose screws when hot-runner systems undergo cycle interruption or oversized shot capacity. Brominated flame-retardant ABS thermally decomposes through dehydrobromination at the barrel wall boundary layer; the characteristic failure sequence begins as brown streaks at the gate land and progresses to acid gas damage on the cavity surface, leading to gas marking and splay rather than conventional short-shot. The injection moulder must maintain melt temperature below 235 °C at the nozzle and barrel residence time under 5 min. A screw with 20:1 L/D and compression ratio 2.2:1 reduces shear heating to an adiabatic rise of 8–12 °C. Hot-runner manifold zones are set to 215 °C at the sprue bushing, 220 °C at the manifold body, and 225 °C at the nozzle tips. Gate diameter is kept between 0.8 mm and 1.2 mm; a smaller gate elevates shear rate above 30,000 s⁻¹, causing local temperature overshoot and rupture of the flame-retardant dispersion. A reverse-cut check ring with 0.05 mm radial clearance is used because standard ring valves accumulate degraded resin in the decompression zone and contaminate subsequent shots. Screw speed is limited to 40–70 rpm with back pressure of 0.5–1.0 MPa. If the press stops for more than 3 min, the barrel is purged with glass-filled polypropylene or general-purpose ABS until the melt flow index of the purge returns to the producer-specified range for virgin material under ISO 1133-1:2022 at 220 °C/10 kg. Terminal applications include server power supply housings and industrial power strips where internal metal shields reflect radiant heat back into the polymer wall. Published data for H1100 H FR in hot-runner systems with more than 8 drops is limited; each multi-cavity tool should be validated by differential scanning calorimetry of purged samples to confirm that the glass transition temperature remains above 95 °C after 20 min holding at 225 °C. Moulders running 100–150 t toggle presses for these parts report that projected-area clamp pressure must be maintained above 0.5 t/cm² to prevent flash without raising barrel temperature.
Inside automotive instrument cluster housings, HVAC control boxes, and cabin fuse covers, flame-retardant ABS must satisfy horizontal burning-rate requirements under FMVSS 302 or ISO 3795 while maintaining dimensional stability at dashboard temperatures. The material is moulded at 225 °C melt temperature and 45–55 °C tool temperature, then optionally annealed at 80 °C for 2 h to relieve stress around press-fit metal inserts and screw bosses. Shrinkage in the flow direction is more significant than in unfilled ABS because the flame-retardant package alters the solidification rate; the mould designer should apply a shrinkage allowance of 0.5–0.7 % in the flow direction and 0.6–0.8 % in the transverse direction, with the exact value confirmed by a first-article inspection on a 250 mm measuring span. Fogging is a critical concern for hidden interior parts because volatile degradation species can condense on the windscreen under solar load. Typical fogging limits for interior polymers are 5 mg gravimetric condensate under ISO 6452 at 100 °C for 16 h. Published data for H1100 H FR in automotive interior applications is limited; validation against OEM-specific fogging and odour limits is required before homologation. Terminal products include cabin fuse box covers, HVAC control housings concealed under the instrument panel, and steering column lower shrouds. The material is not recommended for visible Class A surfaces, exterior trim, or components in direct contact with phthalate-plasticized PVC skins, because plasticizer migration can cause stress cracking at the mounting points over thermal aging cycles.
In power tool housings evaluated under IEC 62841-1 and UL 62841, flame-retardant ABS is selected for its balance of double-insulation capability and impact resistance. The notched Izod impact strength of unfilled flame-retardant ABS is often in the range of 15–25 kJ/m² under ISO 180/1A at 23 °C. When first-generation regrind is added at 25–30 %, total halogen content may remain stable, but the molecular weight distribution broadens through repeated shear-induced chain scission. Notch sensitivity under drop-weight impact increases, and tool housings moulded with 30 % regrind show cold-temperature impact retention of only 70–85 % relative to virgin material at −20 °C, depending on gate size and screw recovery behavior. Boss cracks at the clamshell joint are the primary field failure mode observed on production tools using reclaimed material above 25 % without ramping injection pressure. Acceptable practice is to limit regrind to 20 % for double-insulated tool bodies and to verify impact after 500 h of thermal aging at 90 °C. The flame-retardant package should not be combined with amine-based antistatic masterbatch, because acid-base interaction can reduce flame retardancy and generate surface deposit on the tool. Terminal parts include corded angle grinder motor housings, hammer drill gearbox covers, and jigsaw body shells. The material is not recommended for tool components in direct contact with brake fluid or ester-based lubricants, because the flame-retardant package may accelerate environmental stress cracking at weld lines. Published data for H1100 H FR under combined regrind and thermal aging is limited; full qualification on the production tool with the actual hot-runner balance is required before series production.
Competitive Jiangsu Xinfuda ABS H1100 H FR prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
The product identified as Jiangsu Xinfuda ABS H1100 H FR is an unfilled flame-retardant acrylonitrile-butadiene-styrene resin supplied for injection molding and extrusion. The grade is positioned for thin-wall electrical enclosures, switchgear components, terminal blocks, and appliance housings where a UL 94 V-0 classification at nominal wall thickness is a design prerequisite. Secondary sources do not currently publish a complete property set for this exact formulation. The following technical context is therefore based on the flame-retardant ABS product class, ISO/IEC test methodology, and the manufacturer’s designation logic. The designation contains an FR identifier, but the exact flame-retardant chemistry—brominated, phosphate, or otherwise—must be confirmed from the supplier’s safety data sheet and the UL Yellow Card before design freeze.
Characterization follows the ISO 2580-1 designation system for acrylonitrile-butadiene-styrene moulding and extrusion materials, with additional UL and IEC test methods for fire-related performance. Melt mass-flow rate is determined under ISO 1133-1:2022 at 220 °C and 10 kg; density under ISO 1183-1; tensile yield and elongation at break under ISO 527-2; flexural modulus and strength under ISO 178; notched Charpy impact under ISO 179-1/1eA; heat deflection temperature under ISO 75-2/B at 1.82 MPa; and Vicat softening temperature under ISO 306 at 50 °C/h and 50 N. Fire classification is assessed according to IEC 60695-11-10 or the equivalent UL 94 vertical burn protocol.
Published quantitative data for this specific configuration are limited; lot-specific values are available only through the Jiangsu Xinfuda certificate of analysis and the UL Yellow Card. Any comparative statement that appears in this document should be treated as class-typical data and not as a specification for a particular production lot. The H1100 numerical segment is a manufacturer-specific flow designation rather than a recognized ISO property code; no melt-flow value should be inferred from the trade name without lot data.
High-flow flame-retardant ABS resins are routinely processed on reciprocating-screw injection molding machines with a general-purpose or low-compression screw of 18:1 to 22:1 L/D ratio. Pre-drying in a desiccant dryer at 80 °C for 3 h to 4 h is advisable to reduce pellet moisture below 0.05 wt%. Dew point should remain below −30 °C. In production environments where relative humidity exceeds 60%, drying time may require extension to 4 h to 6 h. Failure to maintain these drying conditions can cause splay, silver streaking, and surface hydrolysis products on molded parts.
Melt temperatures for the class are typically maintained between 210 °C and 240 °C, with nozzle settings in the range 200 °C to 230 °C. Mold surface temperatures between 40 °C and 70 °C are used to balance weld-line strength and residual stress. Shot-to-shot variation in melt temperature above ±5 °C is a known cause of flame-retardant degradation streaks in high-FR ABS systems; therefore, barrel heaters and thermocouple calibration should be verified before start-up. Injection pressures for thin-wall parts are commonly set between 80 MPa and 120 MPa, while holding pressure should be kept lower than 60% of peak injection pressure to reduce gate blush and stress concentration. Back pressure of 0.5 MPa to 2 MPa and screw speed of 40 rpm to 80 rpm are typical for medium shot sizes. Higher shear rates should be avoided because flame-retardant additives can undergo excessive heat generation and migrate to the part surface.
Flame-retardant ABS formulations often show a property cliff-edge at wall thicknesses below 1.5 mm, where the UL 94 V-0 rating can shift to V-1 or HB if local flame-retardant concentration is diluted or if melt residence time causes additive decomposition. The high-flow H1100 H FR designation is intended to address fill of thin sections, but molding trials should confirm that the flame-retardant package remains effective in the as-molded state, not only on compression-molded test plaques. Molding thin-wall parts requires raising material temperature to increase flow length; however, this same action accelerates degradation of many brominated flame-retardant systems. Thermal decomposition releases acidic by-products, causing die drool, black specks, and char deposits on mold vents.
Processing audits on comparable high-flow FR ABS grades have recorded black speck formation after 6 min to 10 min of barrel residence time at temperatures above 230 °C. A start-up procedure that includes purging with general-purpose ABS at 220 °C and reducing barrel temperature during stoppages longer than 10 min is therefore recommended. Weld lines in UL 94 V-0 testing may be the initiation point for flame propagation; gate location should avoid placing weld lines in areas that will be directly exposed to the vertical flame during final-part testing.
Additive migration in FR ABS can result in surface deposits that affect printing, bonding, and plating. The onset of migration is accelerated by mold temperature above 80 °C, excessive injection speed, and long holding times. For parts that require painting or ultrasonic welding, surface contamination must be measured by contact angle or adhesion pull tests according to ISO 2409. If surface energy falls below 34 mN/m, adhesion failure is likely. The use of dry-color masterbatches should be evaluated because certain pigment carriers and lubricants can alter the migration kinetics of the flame-retardant package.
Gate freeze in thin-wall parts is governed by part thickness, mold temperature, and melt viscosity. For a 1 mm wall, gate freeze time can be as short as 0.5 s to 1.5 s; holding pressure must therefore be applied with rapid switch-over from velocity control to pressure control. A switch-over position of 95% to 98% of shot volume is typical to prevent overpacking and flash. Capillary rheometry at apparent shear rates from 100 s⁻¹ to 5,000 s⁻¹ is used to establish gate shear rates and to evaluate viscosity shear sensitivity. High-flow FR ABS generally exhibits pronounced shear thinning, but excessive shear heating can locally exceed the melt-temperature limit and reduce flame-retardant efficiency.
Compliance with the EU Restriction of Hazardous Substances Directive 2011/65/EU and REACH Regulation EC 1907/2006 must be confirmed from the manufacturer’s material declaration for each production lot. The product may contain brominated flame retardants and antimony synergists, which are not prohibited under RoHS but may require disclosure under specific customer substance lists. A UL 94 Yellow Card for the exact grade and color should be requested before design freeze. Electrical applications often require comparative tracking index testing according to IEC 60112. Flame-retardant ABS compounds can show CTI values below 250 V in halogen-containing systems, while general-purpose ABS often remains above 500 V. Glow-wire testing under IEC 60695-2-12 and IEC 60695-2-13 may also be required for unattended appliance applications. The product should not be considered inherently ultraviolet-stable or weather-resistant; long-term outdoor exposure will require capstock or UV stabilization unless otherwise validated.
| Property | Standard | Unit | General-purpose ABS typical class range | Flame-retardant ABS typical class range |
|---|---|---|---|---|
| Density | ISO 1183-1 | g/cm³ | 1.03–1.07 | 1.15–1.20 |
| Melt mass-flow rate | ISO 1133-1:2022, 220 °C/10 kg | g/10 min | 5–30 | 10–30 |
| Tensile yield stress | ISO 527-2 | MPa | 40–50 | 35–45 |
| Flexural modulus | ISO 178 | MPa | 2,000–2,600 | 2,100–2,700 |
| Notched Charpy impact | ISO 179-1/1eA, 23 °C | kJ/m² | 10–25 | 6–15 |
| Heat deflection temperature | ISO 75-2/B, 1.82 MPa | °C | 85–100 | 75–90 |
| UL vertical burning | IEC 60695-11-10/UL 94 | class | HB | V-0 at 1.5–3.0 mm |
| Comparative tracking index | IEC 60112 | V | 500–600 | 200–400 |
Product differentiation of Jiangsu Xinfuda ABS H1100 H FR from general-purpose and high-impact grades is primarily observed in the vertical burn classification at reduced wall thickness, with an expected trade-off in impact and electrical tracking performance. When comparing to halogen-free FR ABS, the H1100 H FR product may show different smoke density, glow-wire, and flow properties depending on the exact flame-retardant package. Internal evaluations should include plaque burning at the thinnest production wall section, not only at the supplier’s standard 1.5 mm or 3.0 mm plaque thickness. Published data for this specific configuration are limited; therefore, application-specific burn test results are required before release to production.
| Requirement | Normative reference | Data required from supplier | Application implication |
|---|---|---|---|
| UL Yellow Card | UL 94 | Grade, color, thickness, V-0 rating | Required for electrical enclosure material acceptance |
| RoHS | 2011/65/EU | Material declaration | Required for EU market access |
| REACH SVHC | EC 1907/2006 | SVHC list | Required for EU market access |
| Comparative tracking index | IEC 60112 | CTI value | Determines minimum creepage distances |
| Glow-wire flammability | IEC 60695-2-12, IEC 60695-2-13 | GWIT, GWFI | Required for unattended appliance applications |
| Moisture content at delivery | ISO 15512 | ppm | Sets pre-drying requirement |
General-purpose ABS with similar melt flow may be easier to color and may retain higher notched Charpy impact, but it will not provide the flame-retardant performance required for internal current-carrying parts. High-impact ABS may offer better low-temperature ductility but usually requires greater wall thickness to pass UL 94 V-0. ABS/PC FR blends often show higher heat deflection temperatures, but the H1100 H FR grade is typically selected where lower melt temperature and higher flow are more important than upper-use temperature. These distinctions must be confirmed through application-specific testing because flame-retardant additives affect weld-line strength, paint adhesion, and ultrasonic welding performance. Avoid combination with amine-based additives if the flame-retardant system contains brominated components; amine compounds can react with acidic degradation products and cause discoloration or surface deposit formation.
At production scale, regular lot-to-lot verification should include melt flow rate, notched Charpy impact, and a vertical burn test on molded plaques at the minimum production wall thickness. Injection molding machines should be maintained with clean screw and barrel surfaces because flame-retardant degradation residues accumulate in check rings and vent channels. If burn performance shifts from V-0 to V-1 without a change in supplier lot, the cause is often excessive residence time or a thermocouple drift of 5 °C to 10 °C rather than a formulation defect. Mold venting must also be inspected when burn performance degrades; volatile decomposition products trapped in blind flow fronts can reduce local flame-retardant concentration and create a false failure traceable to tooling rather than resin.