| HS Code | 355113 |
| Product Name | Essentium PEEK Additive Manufacturing Filament |
| Manufacturer | Essentium |
| Material | Polyether ether ketone (PEEK) |
| Filament Diameter | 1.75 mm |
| Diameter Tolerance | ±0.05 mm |
| Spool Weight | 500 g |
| Color | Natural |
| Density | 1.30 g/cm³ |
| Tensile Strength | 100 MPa |
| Tensile Modulus | 3.6 GPa |
| Elongation At Break | 20% |
| Flexural Strength | 170 MPa |
| Flexural Modulus | 4.1 GPa |
| Notched Izod Impact Strength | 55 J/m |
| Hardness | 85 Shore D |
| Glass Transition Temperature | 143 °C |
| Melting Temperature | 343 °C |
| Heat Deflection Temperature At 0 45 Mpa | 315 °C |
| Heat Deflection Temperature At 1 8 Mpa | 152 °C |
| Continuous Service Temperature | 250 °C |
| Printing Temperature | 370-410 °C |
| Bed Temperature | 120-160 °C |
| Chamber Temperature | 150 °C |
| Drying Temperature | 150 °C for 4 hours |
| Water Absorption | 0.15% |
| Flammability Rating | UL94 V-0 |
| Chemical Resistance | Excellent to acids, bases, and solvents |
| Dielectric Strength | 23 kV/mm |
| Volume Resistivity | 10^16 Ω·cm |
| Dielectric Constant | 3.2 |
As an accredited Essentium PEEK Additive Manufacturing Filament factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | |
| Shipping | |
| Storage |
Competitive Essentium PEEK Additive Manufacturing Filament prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618136850665
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Essentium PEEK Additive Manufacturing Filament is an unfilled polyetheretherketone feedstock produced for high-temperature fused filament fabrication. It is supplied in 1.75 mm and 2.85 mm nominal diameters, with diameter tolerance typically controlled to ±0.05 mm; the certificate of analysis reports lot-specific ovality and moisture. The base polymer is semicrystalline, with a glass transition near 143 °C and a melting endotherm near 343 °C by differential scanning calorimetry under ASTM D3418-21. Because crystallinity, residual stress, and interlayer diffusion are controlled by the print environment, the filament is specified only for high-temperature fused deposition modeling systems with closed chambers, actively heated beds, and all-metal hotends rated for continuous 450 °C service.
In a fused deposition modeling hotend, unfilled PEEK exhibits strong shear-thinning; typical extrusion setpoints are 400–430 °C through a 0.4 mm or 0.6 mm hardened steel or boron nitride-coated nozzle. The feed path must be direct-drive and constrained because the room-temperature flexural modulus of PEEK is near 4.0 GPa, and small bend radii can cause filament fracture at the drive gear. Production-scale printer operators check the melt volume-flow rate of each lot by ISO 1133-1:2022 before adjusting extrusion multiplier and retraction; lot-to-lot viscosity differences alter die swell and road width. A hotend with melt zone residence time below 30 min at maximum setpoint is preferred. At nozzle temperatures above 450 °C, unfilled PEEK can undergo thermal oxidative branching and gel formation, increasing backpressure even before visible discoloration appears.
Moisture control is equally important. The filament should be dried at 150 °C for 3 h in a vacuum dryer or circulating-air oven with a dew point below −30 °C, or at 120 °C for 5 h in a desiccant dryer. Re-drying is required after storage above 60% relative humidity. Undried filament produces hygrothermal voids, surface pits, and reduced interlayer adhesion. During printing, the chamber should remain above 70 °C, the build plate between 120 °C and 160 °C, and layer heights between 0.10 mm and 0.20 mm at linear speeds from 20 mm/s to 40 mm/s for unfilled material. These ranges are equipment-dependent; open-frame printers that cannot sustain the chamber and bed setpoints are not compatible with this feedstock.
XY-plane tensile specimens printed at 0.15 mm layer height and annealed at 200 °C for 2 h typically exhibit tensile strength from 90 MPa to 100 MPa and tensile modulus from 3.5 GPa to 4.0 GPa when tested under ISO 527-2:2012 or ASTM D638-14. Flexural modulus is reported from 4.0 GPa to 4.2 GPa under ISO 178:2019 or ASTM D790-17. Notched Izod impact is frequently near 6 kJ/m² under ASTM D256-10, but print orientation, notch radius, and infill geometry create wide lot-to-lot scatter. Heat deflection temperature at 1.82 MPa is approximately 152 °C for semicrystalline reference material under ASTM D648-18; as-built parts with incomplete crystallinity may fall below this value. Z-direction tensile strength is consistently lower than XY; published fused filament fabrication PEEK studies report 40–70% of XY strength under suboptimal chamber conditions. Published data for Essentium PEEK across all printer and annealing combinations is limited; critical load-bearing parts should be qualified with the user’s specific toolpath and annealing profile.
| Property | Test method | PEEK | PEI (ULTEM 1010) | PPSU |
|---|---|---|---|---|
| Tensile strength | ISO 527-2:2012 | 90–100 MPa | 81 MPa | 70 MPa |
| Tensile modulus | ISO 527-2:2012 | 3.5–4.0 GPa | 3.2 GPa | 2.3 GPa |
| HDT at 1.82 MPa | ASTM D648-18 | 152 °C | 213 °C | 207 °C |
| Glass transition | ASTM D3418-21 | 143 °C | 217 °C | 220 °C |
On filament extrusion lines, unfilled PEEK is typically processed on a co-rotating twin-screw extruder with an L/D ratio between 32:1 and 44:1, a water-free cooling section, and laser diameter gauging. Melt-temperature excursions of more than ±5 °C can change die swell and filament ovality because viscosity is temperature-sensitive. In fused filament fabrication, the deposited layer solidifies rapidly; unless the chamber and bed are hot enough to maintain chain mobility, the as-built polymer remains primarily amorphous or low-crystallinity. Differential scanning calorimetry may show a cold crystallization exotherm above 160 °C and a main melting endotherm near 343 °C. Annealing at 200 °C for 2 h or at 300 °C for 1 h under nitrogen purge increases crystallinity and dimensional stability, but introduces shrinkage. In low-crystallinity fused filament fabrication parts, Z-direction annealing shrinkage of 1–2% has been observed; dimensionally critical parts require thermal mechanical analysis under ISO 11359-2 to establish the exact expansion coefficient and shrinkage. The solid-state thermal expansion coefficient is approximately 50 × 10⁻⁶ K⁻¹ below 143 °C, contributing to edge curl when the chamber temperature is nonuniform.
Production-scale fused deposition modeling lines show that first-layer edge warpage and mid-part delamination appear when the chamber drops below 70 °C or when the build plate is cycled too quickly after printing. Large flat parts should be printed with a sacrificial brim or raft, and removal should not occur until the bed temperature falls below 100 °C. Unfilled PEEK has lower melt strength than some amorphous high-temperature filaments at equivalent superheat; unsupported spans above 400 °C may sag. Support structures are difficult to remove when printed at high chamber temperatures, so self-supporting geometries are preferred.
Chemical compatibility should be qualified for each service fluid. In immersion testing under ASTM D543-21, unfilled PEEK typically retains a high percentage of tensile strength in hot water, steam condensate, automotive coolants, aliphatic hydrocarbons, and hydraulic fluids, but retention depends on temperature, stress, and conditioning time. Concentrated sulfuric acid, strong oxidizing acids above 30 wt%, and chlorinated solvents are outside the assumed service envelope. Environmental stress cracking is evaluated by ISO 22088-2 or ASTM D543-21 with the actual stressed specimen in the service fluid. Water absorption is low, often below 0.5% after 24 h immersion under ISO 62:2008 or ASTM D570-22, but porous printed walls can retain liquid and should be considered in applications such as steam-sterilized surgical instruments. Steam sterilization at 134 °C for 3 min is commonly used for solid PEEK medical devices, but printed parts require annealing and void inspection to prevent microbial ingress; compliance with ISO 17665-1 does not by itself qualify a porous fused filament fabrication article. Direct food-contact status should be confirmed against FDA 21 CFR 177.2415 or equivalent for the specific lot and printing conditions.
The unfilled grade should not be treated as a direct substitute for carbon-fiber or glass-filled PEEK in sliding wear or creep-limited service. Comparative wear testing under ASTM G133-05 or a pin-on-disc method is required because fillers dominate wear and creep response; unfilled PEEK typically has lower wear resistance and higher creep compliance at elevated temperature. Regulatory documentation should be requested for each lot, including REACH EC 1907/2006 and RoHS 2011/65/EU compliance statements.
Interlayer healing in semicrystalline fused filament fabrication parts requires contact temperature and contact time sufficient for chain diffusion across the weld interface. At chamber temperatures below 70 °C, the surface of a deposited PEEK road falls below the glass transition before the next layer is applied, producing a weak boundary. Published fused filament fabrication PEEK studies report Z-direction tensile strength as low as 40–70% of XY strength under these conditions. Fracture surfaces show flat layer-boundary failure, whereas parts printed with chamber temperatures between 90 °C and 150 °C show more ductile tearing and higher interlayer toughness. The build plate should generally be maintained at 120–160 °C, but thick sections with abrupt cross-sectional changes may require staged cooldown to avoid residual-stress cracking. This is most critical in wall thicknesses above 6 mm and in geometries with sharp internal corners; those parts can benefit from sacrificial thermal walls or an insulated build chamber with controlled cooling at ≤1 °C/min through the glass transition.
Interlayer bonding is also sensitive to moisture and melt residence. Even a small amount of moisture can degrade the weld interface and generate porosity at the layer boundary. Nozzle temperature, chamber temperature, and print speed must be treated as a coupled set; increasing nozzle temperature alone does not compensate for a cold chamber because the surface of the prior layer cools too rapidly. Build trials on production-scale equipment should use fixed thermal logs to record chamber air temperature and bed surface temperature, and the data should be compared against the mechanical test results for the specific part orientation.
Compared with PEI grades such as ULTEM 1010, unfilled PEEK typically provides lower water uptake and better retention of mechanical properties in hot aqueous and glycol-based service fluids, but it is more sensitive to chamber temperature and crystallinity control. PEI is amorphous and can be processed at lower chamber temperatures; it also has higher heat deflection temperature at 1.82 MPa, as shown in the comparative table, but may have lower chemical resistance in certain environments. Compared with PPSU, PEEK usually exhibits higher tensile strength and modulus, but notched impact in some fused deposition modeling build orientations may be lower. Compared with filled PEEK, the unfilled Essentium filament avoids abrasive nozzle wear and rough surfaces caused by carbon or glass fiber, but it has lower wear resistance and creep modulus at elevated temperature. The correct material choice depends on service load, chemical exposure, regulatory requirements, and the available fused deposition modeling thermal envelope; final parts should be tested under the relevant ISO or ASTM method because toolpath, chamber control, and annealing history dominate printed mechanical data.