| HS Code | 842478 |
| Manufacturer | Ensinger |
| Productname | TECAFIL PPSU natural |
| Material | Polyphenylsulfone (PPSU) |
| Filamentdiametertolerance Mm | ±0.05 |
| Color | Natural |
| Nozzletemperature C | 360-400 |
| Bedtemperature C | 140-160 |
| Dryingtemperature C | 120-140 |
| Dryingtime H | 2-4 |
| Printspeed Mm S | 30-60 |
| Chemicalresistance | Good |
| Sterilizationmethods | Steam autoclave, gamma, ethylene oxide |
| Flammability | UL94 V-0 |
As an accredited Ensinger TECAFIL PPSU natural - 1,75 mm - Filament Polyphenylsulfone factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | |
| Shipping | |
| Storage |
Competitive Ensinger TECAFIL PPSU natural - 1,75 mm - Filament Polyphenylsulfone prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618136850665
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Ensinger TECAFIL PPSU natural is an unfilled polyphenylsulfone monofilament supplied at a nominal diameter of 1,75 mm for fused filament fabrication. The product designation in manufacturer documentation is TECAFIL PPSU natural – 1,75 mm – Filament Polyphenylsulfone. The base polymer is amorphous, so it does not show a melting endotherm; the processing window is instead controlled by the glass transition. Representative datasheet values include density 1,29 g/cm³ under ISO 1183-1, tensile strength 70 MPa and tensile modulus 2,3 GPa under ISO 527-2, elongation at break above 60 %, Charpy notched impact 30 kJ/m² under ISO 179-1/1eA, flexural modulus 2,4 GPa under ISO 178, and heat deflection temperature HDT/A 214 °C under ISO 75-2. Glass transition is reported at 220 °C. The natural grade is unpigmented, which removes colourant-related nucleation effects and retains the amber transparency typical of polyphenylsulfone.
Because no melting point is present, dimensional change is governed by the coefficient of linear thermal expansion of approximately 55 × 10⁻⁶ K⁻¹ up to the glass transition. The density of 1,29 g/cm³ differs from the typical values for PEEK at 1,32 g/cm³ and PEI at 1,27 g/cm³, which affects spool weight and printed mass. During cooling from the forming temperature to ambient conditions, the part shrinks by thermal contraction rather than by crystallization volume loss. This behaviour reduces some warpage mechanisms associated with semi-crystalline materials but does not eliminate residual stress in thick cross-sections.
Water uptake in polyphenylsulfone is sufficient to create visible and mechanical defects if the filament is not dried. Conditioning under ISO 62 gives water absorption at saturation around 1,1 %. Amorphous sulfone extrusion practice requires residual moisture below 0,03 %. Drying is performed in a dry-air oven at 150 °C for at least 4 h, with spool orientation allowing air circulation between flanges. If drying is omitted, steam expansion at the nozzle produces splay, microbubbles, and reduced interlayer fusion. Storage must be maintained in a desiccated cabinet or sealed bag with a dew point below −20 °C. Published processing data for this specific filament configuration are limited; the drying condition is the commonly used safe threshold for unfilled PPSU feedstock.
The hot end must sustain continuous operation above 350 °C. PTFE-lined hot ends are unsuitable because the continuous service limit of PTFE is ordinarily 260 °C, and decomposition products can form above 350 °C. The nozzle can be brass, plated copper, or hardened steel for this unfilled grade; abrasive-resistant tool steel is not required unless filled variants are used. An all-metal heat break with a polished internal path reduces dead zones and polymer stagnation.
Build plate temperature is typically set between 130 °C and 160 °C, depending on the build surface. A heated chamber is required. Operation below 80 °C produces non-uniform cooling and frozen-in stress. Raising chamber temperature to 80–120 °C reduces the temperature gradient between the formed layer and the surrounding air, but motion components and toolhead electronics may require active cooling if chamber temperature approaches 100 °C.
Rheology of unfilled PPSU is shear-thinning. Melt flow rate is commonly reported around 15 cm³/10 min at 365 °C and 5 kg under ISO 1133-1. Higher molecular weight grades may show lower melt flow and higher impact retention. In filament extrusion, melt temperature is maintained above 330 °C and below 400 °C to avoid thermal degradation. Because the polymer is amorphous, no crystallization plateau exists in the hot end, which simplifies residence-time management relative to semi-crystalline PEEK. Degradation is observed as a shift in melt pressure and as a drop in notched impact of printed specimens tested under ISO 179-1/1eA.
Dimensional control of the 1,75 mm filament is measured with closed-loop laser gauges and melt-pump control in filament manufacture. Short-term diameter variance is maintained within ±0,05 mm. In direct-drive feed systems, the filament path from spool to hot end should remain straight. Poorly wound bobbins that impose lateral force can cause buckling inside the heat break. This failure mode is more likely with 1,75 mm feedstock than with 2,85 mm feedstock because the smaller cross-section reduces critical buckling load. Diameter variance greater than ±0,10 mm alters volumetric drag flow at constant motor steps and can produce alternating over- and under-extrusion. No published coefficient of variation is available for the Ensinger product.
Compared with polysulfone, the PPSU grade shifts the service boundary upward. Polysulfone has a glass transition near 185 °C and an HDT/A near 174 °C. PPSU increases those values to 220 °C and 214 °C while retaining higher notched impact after repeated steam exposure. Compared with polyetherimide, PPSU has lower tensile strength but greater resistance to hot water and steam-induced stress cracking. Polyetherimide can be more notch-sensitive and may embrittle after repeated sterilization. Compared with PEEK, PPSU processes at lower melt temperatures because PEEK requires melting around 343 °C; however, PEEK retains a higher continuous-use temperature because of its semi-crystalline microstructure. PPSU is therefore positioned above polycarbonate and polysulfone, but below PEEK, for continuous thermal resistance.
| Property | TECAFIL PPSU natural | PSU | PEI | PEEK |
|---|---|---|---|---|
| Density, g/cm³ | 1,29 | 1,24 | 1,27 | 1,32 |
| Glass transition, °C | 220 | 185 | 217 | 143, melting 343 |
| HDT/A, °C | 214 | 174 | 200 | 152 amorphous |
| Tensile strength, MPa | 70 | 70 | 105 | 100 |
| Charpy notched, kJ/m² | 30 | 6–10 | 5–8 | 6–8 |
The notched impact of PPSU at 30 kJ/m² is approximately three to five times higher than the typical values listed for PSU, PEI, and PEEK. The trade-off is tensile stiffness. PPSU is more ductile, which can support thin snap-fit features but can reduce dimensional fidelity on unsupported overhangs if the feedstock is not dry and the chamber is too cool. For applications requiring higher tensile modulus at the same approximate glass transition, PEI may be selected. For applications requiring dry heat resistance above 200 °C, PEEK remains the more appropriate choice. For steam-exposed fixtures and medical housings, PPSU offers a balance of impact retention and processing temperature below PEEK.
Saturated steam sterilization in pharmaceutical and medical fixtures is routinely performed at 134 °C for 3 min or at 121 °C for 20 min under ISO 17665-1. The PPSU glass transition of 220 °C provides a substantial margin above the 134 °C plateau. By contrast, polycarbonate with a glass transition near 145 °C has a narrow thermal margin and is more prone to stress relaxation and surface haze after repeated cycles. The dominant failure mode in printed PPSU autoclave fixtures is not polymer meltdown but interlayer delamination caused by residual stress and moisture re-absorption. Parts should be produced with high chamber temperature and dense wall loops, and should be given slow venting cycles during sterilization. Rapid venting can create differential pressure within trapped porosity and promote layer separation.
Injection-molded PPSU shows high retention of notched impact after 100 steam cycles at 134 °C; no identical published dataset exists for FFF parts with controlled raster orientation. The limiting condition is the printing process itself. Sparse infill and under-extruded boundaries create moisture ingress paths that reduce steam-cycle durability. The user is responsible for validating the specific printed geometry under the same wrapping, loading, and sterilizer ramp conditions as production.
Chemical resistance of PPSU derives from the sulfone backbone. The material resists aliphatic hydrocarbons, alcohols, dilute mineral acids, and common disinfectants. It is not recommended for continuous contact with chlorinated solvents such as dichloromethane or with ketones under stress because environmental stress cracking can occur. Concentrated nitric acid and strong oxidizing acids are incompatible. The base polymer can support medical device and food-contact assessments, but compliance statements require lot-specific documentation. Relevant biological evaluation standards may include ISO 10993-1 for evaluation planning, ISO 10993-5 for cytotoxicity, and ISO 10993-10 for irritation and sensitization. For polysulfone resin formulations, FDA 21 CFR 177.2440 may be referenced. The natural unfilled grade is generally preferred for regulatory dossiers because it avoids pigment extraction and simplifies additive review. Published data for this specific filament configuration under biological reactivity testing are limited.
Storage boundaries are dry and cool. Exposure to ambient humidity above 60 % RH without desiccation can return the spool to a moisture level that requires re-drying. A sealed bag with fresh desiccant or a dry cabinet is sufficient for room-temperature storage. If the spool is opened in a non-conditioned room and left on the printer for more than 24 h, printing defects may appear unless a heated dry-feed system is used. Field experience with twin-screw compounding of amorphous sulfone materials shows uncontrolled moisture as the most frequent cause of poor interlayer strength and surface splay.
Model designation differences within the Ensinger TECAFIL family include diameter and colour variants. The 1,75 mm diameter is typically used with direct-drive or short Bowden feed systems, while 2,85 mm feedstock is used where higher feed force is available and where longer Bowden tubes are acceptable. Colour variants and filled materials are not equivalent to natural PPSU. Glass-filled or carbon-fiber-filled PPSU increases tensile modulus, reduces impact, and changes thermal expansion and abrasion behaviour. The natural unfilled grade should therefore be specified only when the application requires the base polymer’s ductility, transparency, and simpler chemical profile.
Processing hardware for PPSU is in the same class as PEI and PEEK, but PPSU does not require the upper melt temperature of PEEK. Hot ends rated for 380 °C may be sufficient, while PEEK often requires hardware rated for 450 °C. The trade-off is chamber cost. A chamber temperature of 80–120 °C remains high enough to require active toolhead cooling and thermal isolation of belts, fans, and electrical connectors. Users must verify the extruder’s maximum continuous temperature and the chamber’s temperature uniformity before starting a print campaign with this material.