    Specifications
    HS Code 196858
    Density 1.24 g/cm³
    Water Absorption 1.8 %
    Tensile Strength At Break 130 MPa
    Tensile Modulus 9000 MPa
    Elongation At Break 3 %
    Flexural Modulus 8000 MPa
    Flexural Strength 160 MPa
    Charpy Notched Impact Strength 7 kJ/m²
    Heat Deflection Temperature At 1 8 Mpa 165 °C
    Melting Point 178 °C
    Surface Resistance 1 x 10^6 to 1 x 10^9 ohm/sq
    Volume Resistivity 1 x 10^6 to 1 x 10^9 ohm·cm

    As an accredited EMS-Grivory Grilamid LV-23 X ESD Nylon 12, 23% Glass Fiber Filled, Dry factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Supplied in a 25 kg sealed bag: dry EMS-Grivory Grilamid LV-23 X ESD, nylon 12 with 23% glass fiber.
    Container Loading (20′ FCL) 20′ FCL loading: Grilamid LV-23 X ESD dry pellets, palletized in sealed bags, secured and braced for safe transit.
    Shipping Ship as non-hazardous polymer pellets in sealed, moisture-proof packaging to maintain dry condition. Avoid exposure to humidity, extreme heat, or direct sunlight. Use standard freight handling with minimal impact. Store in clean, dry environment until use. No special transport restrictions required.
    Storage Store this nylon 12 compound in its original, sealed packaging in a cool, dry environment, ideally below 30°C. Protect from moisture, direct sunlight, and UV exposure. Keep away from heat sources and open flames. Ensure adequate ventilation. Under proper conditions, shelf life is typically 2 years from date of manufacture.
    Shelf Life Shelf life is indefinite when stored dry, sealed, and away from moisture, heat, and UV exposure.
    Application of EMS-Grivory Grilamid LV-23 X ESD Nylon 12, 23% Glass Fiber Filled, Dry

    In semiconductor front-end wafer handling, EMS-Grivory Grilamid LV-23 X ESD Nylon 12, 23% Glass Fiber Filled, Dry is injection-molded into edge-grip wafer nests, vacuum wand bodies, and cassette shelf guides. The grade is selected where an electrostatic-dissipative polymer surface must be maintained without transferring metallic particulate from a permanently conductive filler. Final parts are verified against ANSI/ESD S20.20-2021 and IEC 61340-5-1 as part of an ESD control plan. Surface resistance is measured according to IEC 61340-2-3. The acceptable static-dissipative interval is 1×106 Ω to 1×109 Ω when tested at 12% RH and 23 °C. Parts that are machined after molding must be retested. Machining can remove the dissipation-rich mould skin and expose a more insulating core. This is a documented production control point in fabs where end-effector parts are edge-trimmed and drilled. The PA12 matrix shows lower equilibrium moisture absorption than PA6 or PA66. Dimensional growth prior to machining is established by conditioning specimens according to ISO 62 at 23 °C and 50% RH.

    Pre-drying is performed in a desiccant dryer at 80 °C for 4–6 h. Maximum residual moisture before plastication is 0.10% by mass. A dew point ≤ -30 °C is held in the drying hopper. Moisture above this threshold reduces melt viscosity and can promote surface splay at the gate. The 23% glass fiber loading is abrasive. A bimetallic barrel and hardened screw are used. A screw L/D ratio of 20:1 to 22:1 with a compression ratio of 2.0:1 to 2.2:1 is a common industrial baseline. Injection melt temperature is 240–250 °C. Mould temperature is 70–90 °C. The processing window is narrower than unfilled PA12 because the dissipative filler network can be damaged by overheating. Melt residence time above 250 °C should not exceed 8 min. Longer residence may shift surface resistivity above 1×109 Ω and cannot be reversed by post-mould annealing. The compound is used as supplied. The 23% glass fiber loading is fixed by mass. The dissipative additive package is not intended for letdown. Dilution with unfilled PA12 is not recommended because surface resistivity shifts unpredictably and published data for this specific configuration is limited.

    Tool design for wafer nests must account for anisotropic linear mould shrinkage. Glass fibre orientation along the flow direction can produce lower shrinkage in the fibre axis and higher shrinkage transverse to flow. This is measured on a 2.0 mm thick plaque. A gate at the outermost radius of an edge-grip nest produces radial fibre orientation and improves roundness. Pin gates are avoided. Hot-runner valve gates are used only when shear can be kept below the level that causes fibre breakage. Gate diameter is 0.8–1.0 mm for a nominal 2.0 mm wall. Holding pressure is 40–60 MPa. Packing is maintained until gate freeze. Clamp force is estimated at 0.55–0.75 t/cm² of projected part area. After ejection, parts are annealed at 120 °C for 2 h in a nitrogen-blanketed oven. Annealing relieves residual stress from the 23% glass fibre network and stabilises tight pockets. Dimensional capability of ±0.05 mm is achievable on a well-conditioned tool with a stable mould temperature circuit.

    The terminal components are wafer cassette shelf rails, edge-grip end-effector plates, and vacuum wand tips. These parts are exposed to isopropanol wipe-down, low-humidity cleanroom air, and repeated mechanical contact. Isopropanol short-wipe resistance can be screened according to ASTM D543-14. Prolonged immersion in strong acids or alkaline cleaning solutions should be avoided. Published data for outgassing under vacuum at 10-6 mbar is limited for this specific grade. Validation should include GC-MS headspace testing if the part is used inside a vacuum load lock. Production records include surface resistance, moisture content, melt temperature, and peak cavity pressure. Batch-to-batch variation is addressed by visual inspection for glass fibre agglomerates and by first-shot resistivity coupons.

    What Changes When a 23% Glass-Filled PA12 ESD Grade Is Molded for PCB Handling Nests Instead of Machined POM?

    Replacing machined POM or mineral-filled PEEK in PCB depanelizing fixtures and test socket frames with LV-23 X ESD shifts the dominant failure mode from abrasive wear and chip formation to weld-line cracking at snap-fit features. The 23% glass fiber reinforcement raises modulus and reduces creep under repeated board insertion. The electrostatic-dissipative behavior is required for unprotected PCBs during routing, depaneling, and functional test. Compliance is verified under ANSI/ESD STM11.11 and IEC 61340-2-3. Surface resistance values between 1×106 Ω and 1×109 Ω are the target for bench-top fixtures. RoHS Directive 2011/65/EU Annex II applies for global electronics manufacturing equipment. REACH Candidate List screening should be repeated for each lot if the fixture supplier markets into EU assembly plants.

    Unlike POM, the nylon 12 matrix absorbs a small amount of moisture. Drying before molding is performed at 80 °C for 3–5 h to reach residual moisture below 0.08%. This is lower than the typical 0.10% requirement because the long flow paths of board nests magnify splay and gas traps. Melt temperature is set at 235–245 °C. Mould temperature is fixed at 60–80 °C. The lower mould temperature is used when maximum crystallinity is not required and cycle time is shortened. However, a mould temperature below 60 °C can increase frozen-in stress at the base of snap fingers. This is a critical processing threshold. For a 2.5 mm wall thickness, the cooling time is typically 20–28 s. Packing pressure is 35–55 MPa. Back pressure is held at 1–2 MPa to avoid excessive fibre breakdown.

    The dissipative additive package is shear-sensitive. High injection speeds often create visible flow lines and local surface resistivity drift. A medium injection speed of 50–80 mm/s is a starting point for a 2.5 mm wall. Weld lines must be moved away from board-guide edges. Gate placement at a non-appearance edge or a fan gate is preferred. Valve gates with restricted tips can shear the conductive network and create an insulating halo around the gate. This halo is measured with a two-point probe. If the gate area reads above 1×109 Ω, the gate design is changed. Regrind content should not exceed 15% if surface resistivity is specified. Higher regrind fractions reduce average glass fibre length and can increase resistivity variance. The final fixture is machined with carbide tooling. Milling creates a thin polymer skin that may be less dissipative. All machined surfaces must be post-verified.

    The terminal components are depanelizing fixtures, router jigs, board shielding frames, and test socket base plates. These parts operate at room temperature with occasional exposure to no-clean flux residues and alcohol cleaning. The material is not recommended for continuous service above 90 °C in this application. Short exposure to a 150 °C selective soldering process is permissible only if verified on the final part geometry. Published data for thermal ageing of this ESD formulation under soldering environments is limited. Validation includes 500 h at 85 °C and 85% RH followed by measurement of surface resistance and tensile strength retention according to ASTM D638-14. The glass-fibre filled PA12 has good toughness, but stress concentrations at sharp internal corners in board nests reduce impact life. A minimum internal radius of 0.8 mm is implemented in fixture CAD data.

    When Fuel Vapour Recirculation Demands Static Dissipation in Injection-Molded Quick Connectors

    Fuel vapour recirculation lines in spark-ignition and hybrid vehicles use injection-molded quick connectors where liquid fuel splash and fuel vapour create a static charge accumulation risk. LV-23 X ESD is a candidate when the connector body must be stiff enough to retain a swivel or latch under SAE J2044 dimensional requirements. The 23% glass fibre filling increases hoop strength and limits creep at elevated under-hood temperatures. The PA12 base provides resistance to automotive fuels, road salt, and zinc chloride. Screening is performed according to ISO 1817 and ASTM D543-14. Static dissipation is required across the inner bore and outer latch surfaces. Compliance testing is performed under SAE J2044 for dimensional acceptance and under ISO 19013-1 for fuel hose interface integrity. The ESD property is checked by IEC 61340-2-3. The surface resistance target is 1×104 Ω to 1×109 Ω depending on the OEM specification. The lower end is sometimes required to prevent charge accumulation in fuel vapour with high flow velocity.

    Drying before moulding is critical. The resin should be dried at 80 °C for 4–6 h to 0.10% maximum moisture. In humid plants with relative humidity above 60%, use hopper dryers with a sealed feed throat. Melt temperature is 240–255 °C. Mould temperature is 70–90 °C. This range supports the roundness of O-ring grooves. Roundness of 0.03 mm is required at the O-ring groove. A side gate at the barb produces a weld line at the opposite side; this must be moved away from the latch retention area. Flow simulation is used to place the weld line in a low-stress zone. Holding pressure of 50–70 MPa is used to fill the barb region without short shots. The gate is located at the non-functional tube end. A tunnel gate with a diameter of 1.0–1.2 mm provides automatic separation but can increase shear. If the latch area shows a resistivity above 1×109 Ω, the gate type is changed to an edge gate with a secondary machining step.

    Fuel exposure validation is required before series production. A test matrix is used. Fluids include CE10, E85, and aged gasoline. The test temperature is 60 °C for 1000 h. Dimensional change, tensile strength, and surface resistance are measured after 24 h, 168 h, 500 h, and 1000 h. The following table defines the test matrix.

    Exposure fluidTest temperatureDurationMeasured property after conditioning
    CE1060 °C1000 hDimensional change per ISO 1817, surface resistance per IEC 61340-2-3
    E8560 °C1000 hDimensional change per ISO 1817, tensile strength retention per ASTM D638-14
    ISO 1817 Liquid C60 °C1000 hDimensional change per ISO 1817, surface resistance per IEC 61340-2-3
    Aged gasoline60 °C1000 hVisual cracking, mass change per ISO 1817, surface resistance per IEC 61340-2-3

    Published data for this specific ESD formulation after E85 exposure is limited. Trials are run on production tooling because the barb and latch geometry influence swelling. Batch acceptance includes a leak-decay test on the moulded connector at the OEM-specified pressure. The terminal components are quick-connector bodies, retainer clips, and emission canister nozzles. Direct methanol fuel lines are excluded unless supported by validated exposure data. The glass fibre content increases the risk of stress cracking at sharp barb transitions. A minimum transition radius of 0.5 mm is maintained. If parts are stored outside sealed bags for more than 8 h in humid air, pre-assembly drying at 80 °C for 2 h is required to restore dimensional stability.

    Powder conveying equipment in ATEX-regulated plants uses LV-23 X ESD for rotary valve end plates, pick-up tube bodies, and dust collector flange adapters. The part is not a grounding path for metal equipment. It is a dissipative structural polymer that limits brush discharge on insulating surfaces. This is relevant to zones classified under Directive 2014/34/EU. The design must comply with EN ISO 80079-36 for non-electrical equipment. Electrostatic performance is evaluated against IEC TS 60079-32-1. The material should maintain surface resistance below 1×109 Ω at 30% RH. This is stricter than cleanroom electronics because powder conveying often occurs in low-humidity environments. The glass fibre content provides dimensional stability on bolted flanges. Creep under bolt load is lower than unfilled PA12. The dry-as-moulded condition is essential. If the part absorbs water from washdown cleaning, the ESD property can drift. The surface must be cleaned with dry wipes or dry compressed air. Steam washdown is not recommended because repeated hot water exposure can plasticize the surface and alter the dissipative network.

    Moulding for ATEX components requires a documented process to avoid non-dissipative skins. Mould temperature is maintained at 80–95 °C. Higher mould temperature increases crystallinity and stabilises the surface resistivity. Melt temperature is 240–250 °C. Hot runner manifolds with a balanced thermal profile are preferred. Cold sprue regrind is limited to 10%. This is lower than in electronics fixtures because a single high-resistance region can invalidate the ATEX assessment. External mould release agents are not permitted. They create an insulating film. If ejection is difficult, a self-releasing steel finish or a dry PTFE-free coating is used only after surface resistivity coupon testing. Screw design uses a low-shear mixing section. A compression ratio of 1.8:1 to 2.0:1 and a screw L/D of 20:1 reduce glass-fibre breakage. Gate size is 1.0 mm for a 3.0 mm wall. Packing pressure is 45–65 MPa. Peak cavity pressure above 80 MPa indicates a tendency for gate blush and local resistivity increase.

    Terminal parts include rotary valve end plates, dust collector nozzle bodies, fluidizing hopper ports, and central vacuum tube fittings. These components are bolted to grounded metal assemblies. A resistance-to-ground measurement is performed on the assembled part. The path through the part should be dissipative, but the polymer is not a substitute for a dedicated copper bonding conductor. For flexible hoses and clamps made from the same grade, the end-to-end resistance is measured after 48 h at 50% RH. The application boundary is continuous service below 80 °C. If the conveyed powder exceeds 80 °C, heat ageing shifts the surface resistivity and can embrittle the glass-fibre network. Published data for this specific ESD formulation under ATEX dust conditions is limited. Testing on production parts is required before designation of the equipment category.

    Battery Module End-Plate Charge Dissipation and Coolant Manifold Exposure

    In lithium-ion battery module assembly, end-plate support frames and coolant port adapters require dimensional stability under stack compression, resistance to glycol–water coolants, and static dissipation to prevent charge accumulation near cell busbars. LV-23 X ESD is processed into cell-carrier side plates, coolant manifold brackets, and module mounting feet. The 23% glass fibre content provides a higher tensile modulus than unfilled PA12 and reduces creep under constant clamp load. The ESD performance is measured with IEC 61340-2-3. Target surface resistance is 1×106 Ω to 1×109 Ω at 23 °C and 50% RH. Flame-retardant requirements depend on module design. Published data for this specific ESD grade under UL 94 is limited and must be confirmed on the final part thickness. Current-carrying parts are not made from this material.

    Coolant exposure is a critical process conflict. The PA12 matrix has lower water absorption than PA6 and PA66. However, prolonged exposure to a 50/50 vol% water–glycol mixture at 65 °C still causes plasticization and a reduction in modulus. The material is conditioned for 1000 h in the coolant mixture. Tensile strength and dimensional change are measured per ASTM D638-14 and ISO 1817. After conditioning, surface resistance is measured again. If the surface resistance shifts above 1×109 Ω, the part may no longer provide ESD control. This is a known failure mode in porous or heavily machined seals. The processing window is therefore set to avoid a highly oriented skin that absorbs coolant differently. Mould temperature is 80–95 °C. Melt temperature is 240–255 °C. Packing pressure is 50–70 MPa. Gate placement at the thickest section avoids packing voids at the coolant port threads. The port thread area is a known leak path if glass fibre orientation creates microcracks.

    End-plate frame tooling uses a sequential valve gate system to control the fibre orientation across the part. The weld line at the centre of the frame must be managed by a planar gate or by an overflow tab. If the weld line is located under the stack compression area, crack initiation can occur after thermal cycling. The part is annealed at 120 °C for 2 h after moulding to stabilise dimensions. Regrind is limited to 15%. Higher regrind results in shorter glass fibre length and a measurable loss in tensile modulus. The final parts are stored in sealed bags. If parts absorb moisture before assembly, dimensional growth can affect stack assembly. Pre-assembly drying at 80 °C for 4 h is used if the parts have been exposed to ambient air for more than 24 h in a humid environment.

    The terminal components are module end-plate frames, coolant manifold brackets, and compression pads. They are not the primary electrical insulation between the battery array and the pack housing. A separate polyamide or polyester film is used for high-voltage insulation. The ESD grade is used to prevent charge build-up on mechanical components. Continuous service temperature is limited to 90 °C under mechanical load. Short-term excursions to 120 °C are acceptable only if validated by heat ageing. The maximum stack compression stress should be kept below 40 MPa at 80 °C. Published data for long-term creep of this specific ESD formulation under stack compression is limited. Module designers apply a safety factor of 1.5 on the glass-filled PA12 tensile modulus when running cell-stack expansion simulations.

    Medical Diagnostic Enclosure Grounding Surfaces Are Not an Implant-Grade Claim

    Medical diagnostic analyser bases, board covers, and cable management frames use LV-23 X ESD where the housing must prevent static discharge near sensitive detector boards. The material provides structural rigidity and low moisture uptake in air-conditioned laboratories. Compliance with IEC 60601-1 is for the finished device, not the moulding compound alone. The ESD surface is tested by IEC 61340-2-3. The target surface resistance is 1×106 Ω to 1×109 Ω. The polymer is not evaluated for long-term tissue contact under ISO 10993-1. If the component is used as a patient-contact housing, additional cytotoxicity and skin irritation testing is required on the final part. This limitation is explicit. The grade should not be described as biocompatible. Clean-room moulding may be required for diagnostic device manufacturers that control particulate contamination.

    Drying is performed at 80 °C for 4–6 h. Residual moisture is kept below 0.10%. Melt temperature is 230–245 °C. Mould temperature is 60–80 °C. Lower mould temperature is used for cosmetic surfaces. However, the lower temperature freezes the surface faster and can create an ESD skin with higher resistivity. For grounded enclosure surfaces, a mould temperature closer to 80 °C is preferred. Injection speed is moderate. High-speed injection can form glass-fibre read-through on exposed surfaces. For a 2.0 mm wall, injection speed is 40–70 mm/s. Packing pressure is 35–55 MPa. Gate location is placed behind a label area. A fan gate is used to reduce jetting. The visible surface can be textured with a fine EDM finish. Texturing depth should be 10–20 µm. Deeper textures can trap disinfectant residues.

    Chemical resistance to disinfectants is a key requirement. Isopropanol 70% and quaternary ammonium compounds at normal use concentrations are generally acceptable for short wipe contact when screened by ASTM D543-14. Oxidative disinfectants such as hydrogen peroxide or chlorine-releasing solutions can cause environmental stress cracking when the part is under moulded-in stress. The glass fibre content amplifies this risk at sharp corners. A minimum internal radius of 1.0 mm is required. Annealing at 120 °C for 2 h after moulding is used to reduce residual stress. Published data for this specific ESD grade under repeated disinfection is limited. Validation should include 500 wipe cycles with the actual cleaning solution. The surface resistance is measured after 100, 250, and 500 cycles. A surface resistance above 1×109 Ω or visible microcracking fails the validation.

    The terminal parts are diagnostic analyser bases, electro-mechanical board covers, and cable management frames. These components are not steam-sterilized. Autoclave exposure is not recommended. If a device requires repeated autoclaving, this material is not appropriate. REACH and RoHS compliance are confirmed for the European Union market. The ESD performance is part of the device risk management file. Production records include drying temperature, melt temperature, mould temperature, and surface resistance on a validation coupon. No conclusion is drawn from a single lot. Batch-to-batch ESD variation is controlled by measuring 3 coupons per 1000 parts.

    Free Quote

    Competitive EMS-Grivory Grilamid LV-23 X ESD Nylon 12, 23% Glass Fiber Filled, Dry prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615365186327

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    EMS-Grivory Grilamid LV-23 X ESD is an injection-molding-grade polyamide 12 compound containing 23% by weight glass fiber reinforcement and an electrostatic-dissipative additive system. The dry designation corresponds to data generated on specimens with residual moisture reduced below 0.10% by weight, consistent with polyamide drying practice described in ISO 1110:2019 and the dry-as-molded condition. The grade is used in precision electronic, fuel-system, and material-handling components where dimensional stability, low moisture uptake, stiffness, and controlled surface resistivity are simultaneous requirements.

    Typical dry-condition mechanical values reported in supplier literature include a tensile modulus of approximately 6,000 MPa and a tensile stress at break near 110 MPa according to ISO 527-1/-2. The density is approximately 1.19 g/cm³ when measured under ISO 1183-1:2019. These values separate the product from non-reinforced polyamide 12, whose dry tensile modulus is approximately 1,500 MPa. The 23% glass fiber content raises heat-deflection performance and reduces isotropic shrinkage, while the ESD package shifts the surface from an insulating range above 10¹² Ω to a dissipative range.

    What drying and melt-processing limits follow from the conductive filler?

    Pre-drying is mandatory when the material has been exposed to ambient humidity above 35% RH. A desiccant dryer with a dew point at or below -40 °C and an air temperature of 80 °C for 4–6 h is recommended to bring residual moisture below 0.10%. Hopper residence time at drying temperature should not exceed 2 h, because prolonged hot-hoper storage can oxidize the conductive additive system and shift surface resistivity upward.

    Injection molding should be performed with a three-zone general-purpose screw having an L/D ratio of 20:1 to 25:1 and a compression ratio of 2.0:1 to 2.5:1. The melt temperature measured at the nozzle is typically 240–260 °C, and the mold surface temperature should remain within 60–100 °C. For thin-wall sections below 1.5 mm, the upper end of the mold-temperature range reduces frozen-in orientation and helps maintain continuity of the conductive network. Back pressure of 5–10 bar hydraulic is used to homogenize the glass fiber without excessive shear heating. Clamp force estimates follow normal glass-filled polyamide practice at 0.5–0.8 kN/cm² of projected part area.

    Excessive residence time above 260 °C can degrade the ESD additive and produce surface streaks on molded parts. Hot-runner systems should be externally heated and controlled to a thermal uniformity of ±5 °C across the manifold and tips. Weld lines are particularly critical in ESD grades because the conductive pathway is interrupted at the flow front merge point. Gate placement should place weld lines away from charge-sensitive functional surfaces, and valve-gate or overflow-well geometries are preferred where multiple gates are unavoidable.

    Surface resistivity and charge decay in low-moisture electronic carriers

    Electrostatic dissipation is characterized by surface resistivity in the range of 10⁶–10⁹ Ω when tested on dry molded plaques according to IEC 62631-3-1 or ASTM D257-14. Volume resistivity is normally in the range of 10⁶–10⁸ Ω·m under the same dry condition. Resistivity values are thickness-dependent and orientation-dependent. Thin walls, high shear, and sharp geometric transitions can reduce the number of connected conductive particles across the measurement path, shifting resistivity by one to two decades without any change in bulk formulation.

    The following table lists representative dry-condition values from EMS-Grivory technical literature for the product. Lot-to-lot tolerance should be confirmed against the current production specification and the actual color batch.

    Representative dry-condition property profile for EMS-Grivory Grilamid LV-23 X ESD
    Property Standard Value Condition
    Density ISO 1183-1:2019 1.19 g/cm³ 23 °C, dry
    Tensile modulus ISO 527-1/-2 6,000 MPa Dry as molded
    Tensile stress at break ISO 527-1/-2 110 MPa Dry as molded
    Nominal strain at break ISO 527-1/-2 4.0% Dry as molded
    Charpy notched impact strength ISO 179-1/1eA 12 kJ/m² 23 °C, dry
    Melting point ISO 11357-1/-3 176 °C 20 °C/min
    Heat deflection temperature ISO 75-1/-2 155 °C 1.80 MPa, dry
    Water absorption ISO 62:2008 1.1% 23 °C, 50% RH equilibrium
    Surface resistivity IEC 62631-3-1, ASTM D257-14 10⁶–10⁹ Ω Dry molded plaque
    Mold shrinkage ISO 294-4 0.25–0.45% Flow direction

    In PCB magazine rails and wafer-handling nests, the 23% glass fiber content raises beam stiffness compared with unfilled polyamide 12. Deflection under self-weight is lower for unsupported spans, allowing tighter dimensional windows in automated assembly. For process capability studies, ISO 294-1 injection-molded plaques should be used to measure surface resistivity at fixed gate location and packing pressure. Flow-direction surface resistivity can be lower by 0.5–1 decade than cross-flow resistivity in film-gated parts, so electrical measurements should be taken at the lowest-orientation region only when the end-use risk assessment requires it.

    When a PA12 GF23 ESD grade replaces unfilled PA12 or PA6 GF25 in fuel-contact clips

    The principal difference from a PA6 GF25 ESD compound is equilibrium moisture uptake. At 23 °C and 50% RH, polyamide 12 absorbs approximately 1.1% moisture according to ISO 62:2008, whereas PA6 with 25% glass fiber typically absorbs 2.5% or more. The lower water uptake reduces hygroscopic swelling and stabilizes the conductive network in humid assembly environments. Compared with unfilled PA12, the 23% glass fiber raises dry tensile modulus from approximately 1,500 MPa to 6,000 MPa and raises heat deflection temperature at 1.80 MPa from about 50 °C to approximately 155 °C, while lowering ductile failure strain.

    Comparative profile of candidate ESD polyamide materials under dry condition
    Property Grilamid LV-23 X ESD Unfilled PA12 dry PA6 GF25 ESD dry
    Density 1.19 g/cm³ 1.02 g/cm³ 1.32 g/cm³
    Tensile modulus 6,000 MPa 1,500 MPa 8,500 MPa
    Heat deflection temperature, 1.80 MPa 155 °C 50 °C 200 °C
    Water absorption at 23 °C, 50% RH 1.1% 1.0% 2.5%
    Surface resistivity 10⁶–10⁹ Ω >10¹³ Ω 10⁶–10⁹ Ω

    In fuel-contact clips, the low moisture uptake of PA12 reduces dimensional change after assembly in humid underhood environments. The glass fiber reinforcement reduces creep under clamp load, but the ESD additive package should not be assumed to be inert in all fuel blends. Compatibility with test fuels should be verified on molded parts according to ISO 175:2010 or ASTM D543-20, including measurement of surface resistivity before and after fuel exposure. Published data for this specific configuration are limited for aggressive oxygenated fuel blends, so qualification on production geometry is required.

    Chemical resistance, service-temperature boundaries, and tooling limitations in dry-as-molded parts

    Polyamide 12 is resistant to aliphatic and aromatic hydrocarbons, lubricating oils, diesel, grease, zinc chloride, and calcium chloride at ambient temperatures. The glass fiber phase is susceptible to acid attack at the fiber-matrix interface when pH falls below 2.0 and temperature exceeds 40 °C. Strong mineral acids, phenols, cresols, and chlorinated solvents at elevated temperature can attack the matrix or induce stress cracking. Chemical exposure should be evaluated on finished parts using ISO 175:2010 or ASTM D543-20, not solely on unreinforced resin-grade data.

    Continuous service temperature in air is limited by oxidative aging rather than by short-term melting point. For polyamide 12 grades, UL 746B relative thermal index values are commonly 65–90 °C for electrical performance and 65–90 °C for mechanical strength without impact, but the exact value for this ESD grade must be confirmed from the supplier’s UL Yellow Card. Processing at the lower end of the melt-temperature range reduces fiber breakage but may increase surface resistivity in thin walls because of reduced conductive-network formation. The processing optimum should be established on the actual mold using surface-resistivity plaques per ASTM D257-14.

    For pneumatic conveyor links and chip-tray stops, the glass-filled ESD grade provides dimensional stability and dissipative behavior under dry indoor conditions. Standardized abrasion tests such as ASTM D4060-19 measure a specific wear mode and do not directly predict part life, so application-specific wear data on the candidate geometry are required. Tooling should use hardened wear-resistant gate inserts because 23% glass fiber accelerates gate and hot-runner tip wear. Gate inserts should be inspected at intervals of 50,000–100,000 cycles when processing glass-filled polyamide. Mold-temperature uniformity across the cavity should be maintained within ±5 °C to avoid differential shrinkage and local variation in surface resistivity.

    Top