| HS Code | 802185 |
| Density | 3.62 g/cc |
| Tensile Strength Yield | 10.3 MPa |
| Tensile Strength Break | 10.3 MPa |
| Elongation At Break | 2.0 % |
| Tensile Modulus | 1.72 GPa |
| Flexural Modulus | 1.72 GPa |
| Flexural Strength | 20.7 MPa |
| Compressive Strength | 34.5 MPa |
| Hardness Shore D | 67 |
| Impact Strength Notched Izod | 0.107 J/cm |
| Thermal Conductivity | 0.49 W/m-K |
| Cte Linear | 5.0 µm/m-°C |
| Specific Heat | 1.0 J/g-°C |
| Melting Point | 130 °C |
| Maximum Service Temperature Air | 80 °C |
| Flammability Ul94 | HB |
| Water Absorption | 0.01 % |
As an accredited Ecomass Technologies HDPE 3620BX60 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Ecomass Technologies HDPE 3620BX60 is supplied in 25 kg (55 lb) moisture-resistant bags, typically palletized for industrial handling. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): Ecomass Technologies HDPE 3620BX60 in 25 kg bags, palletized, shrink-wrapped, and secured for safe ocean transport. |
| Shipping | Ecomass Technologies HDPE 3620BX60 is a non-hazardous, high-density polyethylene composite supplied as pellets. It ships in sealed bags, pails, or drums at ambient temperature. Keep containers closed, dry, and protected from extreme heat, sunlight, and moisture. No special DOT placarding or temperature control is normally required. |
| Storage | Store Ecomass Technologies HDPE 3620BX60 in a cool, dry, well-ventilated area, away from direct sunlight, heat, flames, acids, solvents, and strong oxidizers. Keep original containers sealed, labeled, and off the floor. Avoid moisture, excessive stacking, and physical damage. Follow local regulations and SDS recommendations. Use appropriate PPE when handling. Maintain stable temperature and humidity. Do not eat, drink, or smoke in storage areas. |
| Shelf Life | Shelf life is approximately 24 months when stored in a cool, dry, well-ventilated area in original, unopened packaging. |
Components in diagnostic X-ray equipment that require space-efficient attenuation without cast lead are produced from high-density polyethylene filled with tungsten-based particulate at a nominal density of 3.60 g/cm³ when tested to ISO 1183-1:2019. In Ecomass Technologies HDPE 3620BX60, the high-density polyethylene matrix carries the filler phase at a loading that supports attenuation across the 60 kVp to 150 kVp diagnostic range, with lead equivalence values determined by the end-user under IEC 61331-1:2014 and IEC 61331-3:2014. This application segment uses the compound as a ready-to-mould material at 100% by weight; clean in-house regrind from sprues and runners may be re-introduced at 10–15 wt% only after density checks on the regrind fraction, because non-uniform filler distribution in reused material changes attenuation linearity in multi-cavity tools. The primary downstream process is reciprocating-screw injection moulding with a screw L/D ratio of 18:1 to 22:1, barrel temperatures from feed to nozzle of 180°C, 195°C, 210°C, and 220°C, and mould temperature of 20–60°C. Terminal products include collimator housings, syringe shields, vial transport sleeves, and scatter-suppression panels located adjacent to flat-panel detectors.
On production-scale lines the defining process conflict is the narrow window between incomplete fill and filler-phase separation in walls below 2.0 mm. Injection speed is normally set at 30–80 mm/s, with switch-over by screw position rather than hydraulic time, and cushion maintained at 4–8 mm to avoid decompression at the screw tip. Clamp force is calculated as 4.5–6.0 t/in² of projected area; for thin-wall diagnostic accessories with wall stock below 2.5 mm, the required clamp force rises to 5.5–7.0 t/in² to prevent flash at the elevated melt pressures used. Venting depth is critical: tools must be vented at the end of flow with land depths of 0.02–0.04 mm to prevent gas entrapment that appears as surface pitting and attenuation voids on radiographic QA film. The compound does not require desiccant drying under normal indoor storage due to the hydrophobic HDPE matrix, but condensation at RH > 60% is removed by 2 h at 70°C in a desiccant dryer before hopper loading. Abrasive tungsten filler accelerates screw and barrel wear; bimetallic barrels and hardened chrome-plated screw flights are normally specified after 50,000 cycles on machines without surface treatment.
| Parameter | Standard / method | Typical condition |
|---|---|---|
| Compound density | ISO 1183-1:2019 | 23 °C, water immersion |
| Tensile properties | ISO 527-2:2012 | 5 mm/min |
| X-ray protective device | IEC 61331-1:2014 | 60–150 kVp |
| Restricted substances | IEC 63000:2016 | RoHS 2011/65/EU |
| Skin-contact biocompatibility | ISO 10993-5:2009 | extract dilution |
Nuclear medicine shielding components are differentiated from diagnostic X-ray parts by isotope-specific scatter and thicker wall sections that sit outside the 100–511 keV photon energy window. For Ecomass Technologies HDPE 3620BX60, the material is used for Tc-99m generator surrounds, PET transport vial shields, radioiodine therapy vial sleeves, and brachytherapy seed storage pots. The primary compliance framework is the IAEA transport safety regime under SSR-6 (Rev. 1) for Type A packaging if the shielding component forms part of a certified container, supplemented by source classification under ISO 2919:2012. The formulation is processed at 100% as supplied for monolithic shielding; when a two-shot construction is required to add a decontaminable surface layer, the shielding core remains 100% HDPE 3620BX60 and the skin layer is unfilled HDPE at 1.5–2.0 mm, which must not be included in attenuation calculations because it contributes negligible lead equivalence. Thick-wall injection moulding is the dominant downstream process for wall sections of 10–25 mm; gates are sized at 40–60% of nominal wall thickness, with holding pressure applied until gate freeze rather than by fixed timer. Terminal products include generator shields, dose calibrator liners, PET transport vial containers, and shielded unit-dose carriers.
Field data from thick-wall runs show that centre-shrink porosity occurs when mould temperature falls below 30°C and holding pressure is released before the gate freezes. Packing pressure is typically held at 70–90 MPa for 8–15 s per 10 mm of wall section; when ambient relative humidity exceeds 60%, pellet surface moisture produces surface splay even though HDPE is not hygroscopic, so hopper drying at 70°C for 2 h is used. The high filler content lowers thermal conductivity relative to metal shields, so cooling time scales nonlinearly with wall thickness; production cycles for 20 mm walls can exceed 180 s until the centre reaches an ejection temperature below 70°C. One operational boundary is the upper continuous service temperature of 65°C; sustained exposure above this value causes creep that can alter shielding geometry and compromise the source-to-shield distance. The material should not be exposed to strong oxidizing acids or to solvent systems that attack high-density polyethylene, including hot benzene and chlorinated hydrocarbons at elevated pressure.
Rotating-equipment counterweights, flywheel masses, pump impeller balancing rings, and centrifuge rotor counterweights require a combination of high density, dimensional reproducibility, and the ability to be insert-moulded over metallic hubs. In this segment, the product is specified according to ISO 1940-1:2003 balance quality grades; compound density is verified to ASTM D792-20, and moulded shrinkage is checked to ISO 294-4:2018 because imbalance shift after post-mould crystallization is unacceptable. The addition proportion is 100% Ecomass Technologies HDPE 3620BX60 by weight; mass tuning after moulding is performed by machining rather than dry-blending with unfilled HDPE, because dry-blending at 5–15 wt% unfilled HDPE creates density inhomogeneity that can move the centre of gravity by more than the balance tolerance. Downstream processing is insert injection moulding over preheated brass or steel bushings; inserts are heated to 110–130°C to avoid cold-insert sink and post-mould cracking. Melt temperature is held at 200–225°C, injection pressure at 90–130 MPa, and mould temperature at 25–45°C. Terminal product types include fan balancing disks, crankshaft harmonic damper masses, centrifuge balance rings, and counterweight blocks for medical rotary equipment. Press-fit installation is limited to 0.3–0.5% interference on the inner bushing because the semi-crystalline matrix with high filler loading has reduced strain at break relative to unfilled HDPE; validation must be performed by testing the bushing pull-out force after thermal cycling from -20°C to 65°C.
Enclosures for gamma and beta sources, storage cabinet liners, and modular shielding blocks that were previously fabricated from cast lead sheet are candidates for the tungsten-filled HDPE grade when the assembly must avoid mixed-metal waste streams or reduce surface contamination hazards. Under this substitution, the component is evaluated against the radiation protection requirements of IAEA GSR Part 3, with outer surfaces tested for accessible dose rate rather than a fixed thickness equivalence; the material is also screened against REACH Annex XVII and RoHS 2011/65/EU because the absence of metallic lead simplifies end-of-life classification. The material is processed at 100% by weight for compression-moulded modular blocks with wall thicknesses from 10 mm to 40 mm, using press pressure of 10–20 MPa and platen temperature of 190–210°C. For thinner equipment covers, injection moulding at 210–230°C is used with a regrind limit of 10 wt% after density verification. Terminal products include source transfer cask liners, glovebox wall saddles, beta sample container overlays, and interlocking modular shielding panels. The main process restriction is the 65°C continuous service ceiling; enclosures in direct contact with heated process equipment require thermal isolation to prevent creep that closes interlock gaps or reduces panel thickness.
Dental and veterinary X-ray accessory moulding uses the compound for collimation cones, handheld X-ray unit housings, and portable veterinary collimator shields where repeated drop loading at 1.0 m onto concrete must not produce cracks that propagate along knit lines. For Ecomass Technologies HDPE 3620BX60, the specification pathway includes IEC 60601-1-3:2008 for radiation protection in diagnostic X-ray equipment and ISO 10993-10:2021 for skin sensitization because handheld units involve operator skin contact. The material is used at 100% by weight as the shielding core; when a soft-touch or cleanable outer surface is needed, a two-shot process with an unfilled HDPE skin of 1.5–2.0 mm is used, but attenuation calculations exclude the skin. The downstream process is injection moulding with hot-runner valve gates; gate diameter is set at 1.5–2.5 mm for nominal walls down to 2.2 mm to reduce jetting and filler-phase separation at the gate. Terminal product types include dental intraoral X-ray cone covers, handheld X-ray fluorescence analyzer housings, veterinary portable collimators, and bitewing sensor positioning shields.
Production-scale moulds for multi-cavity dental accessory tools show cavity-to-cavity density variation when the cold-runner diameter is below 6.0 mm, because the dense melt loses heat rapidly in long runner legs and creates differential packing. Melt temperature is therefore held at 215–230°C with back pressure of 0.5–1.5 MPa; increasing injection pressure above 150 MPa does not improve centre-line packing and accelerates check-ring and screw-tip wear. Ejection should not occur above 70°C to avoid post-mould shrinkage that distorts collimation edges; cooling time for thin walls is 2.5–3.0 s/mm² of nominal wall thickness. Because the high-density filler is abrasive, short shots caused by check-ring leakage are a known failure mode after approximately 30,000–50,000 cycles on unhardened reciprocating screws; process monitoring of cushion position is used to detect the onset of non-return valve wear.
Portable X-ray fluorescence analyzers, nuclear density gauges, and industrial level transmitters require compact source holders and detector shields that combine impact resistance with stable shielding geometry in handheld and field-deployed tools. Ecomass Technologies HDPE 3620BX60 is used for source collimator blocks, detector housings, and source shutter bodies in these devices; compliance is assessed under IEC 61010-1:2010 for electrical safety of laboratory equipment and, where applicable, IAEA GSR Part 3 for source shielding. The composition is processed at 100% by weight without dilution; if recycled material is re-introduced from parts reject streams, it is limited to 5 wt% because particle-size reduction during regrind can change the apparent attenuation cross-section in thin regions. The downstream process is injection moulding with a shot size that should occupy 40–75% of the barrel capacity to minimize residence time; melt temperature is 200–220°C, mould temperature 30–50°C, and screw back pressure 0.3–0.8 MPa. Terminal products include portable XRF window shields, source shutter housings for nucleonic gauges, and detector collimator bodies. Prolonged residence times above 15 min at 220°C should be avoided because filler settling in the barrel front section can generate density stratification; when the machine is paused, the barrel should be repeatedly purged every 10–15 min or the rear zone reduced to 150°C.
Competitive Ecomass Technologies HDPE 3620BX60 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Ecomass Technologies HDPE 3620BX60 is a high-density polyethylene matrix composite carrying a high-loading radiopaque filler system. The product designation encodes a nominal specific gravity of 3.62 g/cm³ and the BX60 filler architecture. Published component-level data for this specific compound remain limited; however, the product family is supplied as pelletized feedstock for injection molding, profile extrusion, and compression molding on conventional thermoplastic equipment. The grade is specified where lead-free mass addition, vibration damping, or low-energy X-ray attenuation is required without the regulatory burden associated with elemental lead. Density is measured by ASTM D792-20 or ISO 1183-1:2019, and melt flow rate is determined by ASTM D1238-13 at 190°C/2.16 kg. These two values are commonly used for incoming inspection because they correlate with filler loading and mold-filling capability.
The addition of a radiopaque filler to a semicrystalline HDPE matrix raises melt viscosity at low shear rates while preserving shear-thinning behavior above approximately 100 s⁻¹. For high-density polyethylene compounds in the 3.6 g/cm³ density class, processing requires a general-purpose screw with L/D ratio between 20:1 and 24:1 and compression ratio between 2.5:1 and 3.5:1. Melt temperature is maintained between 190°C and 240°C, with mold temperature set between 20°C and 60°C. Back pressure is held between 0.3 MPa and 0.7 MPa to avoid over-shearing the filled melt. Injection speeds below 100 mm/s often produce flow lines and short shots in thin-wall sections because the filled compound exhibits reduced viscous heating compared with unfilled HDPE. Pre-drying at 80°C for 2–4 h is recommended when resin moisture exceeds 0.05 wt% or when ambient relative humidity exceeds 60%; otherwise surface splay and internal porosity may develop in molded parts. Production-scale experience on 150–250 tonne clamp-force machines shows that consistent shot-to-shot density requires closed-loop cushion control within ±2 mm and nozzle temperatures that avoid cold-slug formation.
Compounding of filled HDPE in the 3.6 g/cm³ density class is performed on intermeshing co-rotating twin-screw extruders with L/D ratios between 40:1 and 52:1 to disperse the radiopaque filler without degrading the polyethylene matrix. Strand pelletizing requires water-bath temperature control below 30°C; elevated pelletizing water temperatures lead to pellet agglomeration and irregular feed in subsequent injection molding. Batch-to-batch density variation is controlled by gravimetric feeder accuracy of ±0.5% on filler and polymer streams and by in-line density verification on molded plaques. Screw and barrel wear is more severe than unfilled HDPE because the filler package raises melt viscosity and abrasiveness; hardened tool steel and periodic flight inspection are specified. Barrel residence time should not exceed 10 minutes above 230°C, because extended residence generates polyethylene chain scission and black specks.
Gate sizing for this compound follows a conservative approach: round or rectangular edge gates with a minimum depth of 50% of the nominal wall thickness are preferred; pinpoint gates below 1.0 mm diameter are avoided because high filler loadings cause localized shear heating and gate blush. Mold shrinkage is anisotropic and lower than unfilled HDPE, typically constrained by filler volume fraction; data from ASTM D955-21 for comparable high-density polyethylene compounds in this density band fall between 0.8% and 1.5% in the flow direction and 1.0–2.0% cross-flow. Ejection draft angles of 1°–2° are used to compensate for the compound's higher modulus and lower ductility. Venting depth should not exceed 0.02 mm to prevent flash while allowing gas escape from moisture or filler decomposition products. These tooling constraints are derived from filled-polyethylene injection molding practice rather than from grade-specific published data, which remains limited.
Tensile testing of high-loading filled HDPE composites in the 3.5–3.8 g/cm³ density range typically shows tensile yield strength between 18 MPa and 24 MPa and tensile elongation at break between 3% and 8%. The filled material has higher flexural modulus than unfilled HDPE, generally between 1.5 GPa and 2.5 GPa per ASTM D790-17 or ISO 178:2019, while notched Izod impact strength determined by ASTM D256-10/ISO 180/A remains in the 30–60 J/m range. The primary trade-off is ductility: unfilled HDPE elongates significantly more under tensile load, whereas the filled grade fractures at lower strain. This difference directly influences snap-fit and press-fit design. Heat deflection temperature at 1.8 MPa, measured by ASTM D648-18 or ISO 75-2/B, is generally 60–80°C for filled HDPE grades, sufficient for many industrial housings but not for continuous service above 90°C. The exact certified values for Ecomass HDPE 3620BX60 should be verified against the manufacturer's prevailing certificate of analysis; the ranges stated here are representative of the product class.
| Property | Test designation | HDPE 3620BX60 class | Unfilled HDPE | Lead-filled HDPE analog |
|---|---|---|---|---|
| Density | ASTM D792-20 | 3.60–3.65 g/cm³ | 0.95–0.97 g/cm³ | 4.0–6.0 g/cm³ |
| Tensile yield strength | ASTM D638-14 | 18–24 MPa | 20–30 MPa | 8–15 MPa |
| Tensile elongation at break | ASTM D638-14 | 3–8% | 300–700% | 2–10% |
| Flexural modulus | ASTM D790-17 | 1.5–2.5 GPa | 1.0–1.4 GPa | 2.0–4.0 GPa |
| Notched Izod impact | ASTM D256-10 | 30–60 J/m | 60–120 J/m | 15–40 J/m |
| Heat deflection temperature at 1.8 MPa | ASTM D648-18 | 60–80°C | 50–70°C | 50–80°C |
Radiation absorption in the 25–150 keV photon energy range depends on filler effective atomic number and mass thickness. A 3.62 g/cm³ composite can replace lead sheet in certain low-energy X-ray housings only if wall thickness is increased to compensate for density difference; published data for this specific configuration is limited. Calculations should use measured attenuation coefficients from specimen testing under IEC 61331-1:2014 or comparable narrow-beam geometry rather than density scaling alone.
Material selection for radiation-shielding components typically begins with photon energy, particle fluence, and cumulative dose requirements. HDPE 3620BX60 occupies an intermediate density band that is unsuitable for high-energy gamma shielding where tungsten-loaded grades above 10 g/cm³ are commonly used, but it is appropriate for low-energy X-ray equipment, collimator housings, and source holders where moderate attenuation and lead-free status are required. The material has been adopted in dental radiographic accessories, isotope transport containers, and counterweights for medical devices; however, published field evaluations for these applications are scarce, and each design must be validated by direct dosimetry because filler distribution and part thickness influence beam hardening and scatter.
Compared with unfilled HDPE, HDPE 3620BX60 provides higher density, higher stiffness, lower elongation, and lower thermal expansion, but also lower impact resistance and more demanding molding behavior. Compared with lead-filled polymer systems, the Ecomass compound avoids lead, cadmium, and mercury restrictions under RoHS Directive 2011/65/EU as amended by (EU) 2015/863, and simplifies end-of-life disposal. However, the lower density means greater wall thickness is needed to achieve equivalent lead equivalence in some low-energy shielding scenarios. Compared with tungsten-loaded HDPE grades with densities above 6 g/cm³, HDPE 3620BX60 is more easily processed but provides less photon attenuation per unit thickness. The selection therefore depends on whether minimum weight, minimum thickness, or regulatory simplicity is the controlling requirement.
Within the Ecomass high-density polyethylene line, the 3620BX60 designation differs from lower-density HDPE grades by filler loading and from higher-density tungsten-containing grades by effective atomic number. The intermediate density produces a specific attenuation coefficient that is lower than grades carrying 90 wt% tungsten, but the less abrasive filler package reduces screw wear and permits higher regrind inclusion under validated conditions. Published data for this exact grade are limited; however, the density range bisects the selection space between a standard 2.5 g/cm³ HDPE composite and an 11 g/cm³ tungsten-loaded HDPE shielding grade. Distributor annotations sometimes identify the BX60 suffix with a nominal 60 wt% radiopaque filler system; the exact compositional split is not consistently disclosed and should be confirmed with Ecomass Technologies.
Chemical resistance follows the HDPE matrix: the material resists dilute acids, alkalis, and aqueous salt solutions at ambient temperature but is attacked by strong oxidizing acids, aromatic hydrocarbons, and halogenated solvents under stress. Environmental stress cracking resistance measured by ASTM D1693-21 decreases as filler loading increases; users should expect lower ESCR than unfilled HDPE and should specify finite strain testing for parts with molded-in inserts. Moisture absorption remains below 0.1 wt% at 23°C/50% RH when measured by ISO 62:2008. Thermal expansion for composites in this density class is typically lower than unfilled HDPE, reducing dimensional growth in outdoor enclosures but increasing risk of differential expansion at metal insert interfaces.
| Requirement | Standard/Reference | Status/Test |
|---|---|---|
| Restriction of hazardous substances | RoHS 2011/65/EU + (EU) 2015/863 | Lead-free radiopaque filler system |
| REACH SVHC | EC 1907/2006 | No SVHC above 0.1 wt%; lot certification required |
| Density | ASTM D792-20 / ISO 1183-1:2019 | 3.60–3.65 g/cm³ typical |
| Melt flow rate | ASTM D1238-13 at 190°C/2.16 kg | 2–8 g/10 min typical for product class |
| Tensile yield strength | ASTM D638-14 / ISO 527-2:2021 | 18–24 MPa typical |
| Flame performance | UL 94 HB | Conditional on part thickness; test plaque required |
Because the grade is delivered in pelletized form, moisture management during storage influences downstream consistency. Silos and gaylords should be kept sealed, and material exposed to ambient air for more than 24 h should be re-dried before molding. Feed throat temperature should remain below 50°C to prevent premature melting and bridging. Conveying systems should use low-angle hoppers and avoid long-radius bends that generate fines; fines act as nucleation sites and create visual defects in molded parts. Static-weighting applications include flywheel counterweights, vibration-damping base plates, and radiation-shielding collimators. In rotating equipment, the higher density of HDPE 3620BX60 reduces the volume required for a given mass compared with unfilled HDPE, but machining operations generate fine filler-containing swarf that requires standard particulate controls.
Operational boundaries include a maximum continuous service temperature below 90°C, pre-drying at 80°C for 2–4 h when ambient relative humidity exceeds 60%, and incompatibility with strong oxidizing acids and certain chlorinated solvents at elevated temperature. The compound should not be exposed to ultraviolet radiation for extended outdoor service unless a UV-stabilized additive package is incorporated. Repeated reprocessing above 5 wt% regrind is not recommended without lot validation because filler distribution and impact performance may shift. The material does not carry a general FDA 21 CFR 177.1520 food-contact clearance; use in food-contact applications requires direct verification. Published data for this specific configuration is limited; prospective users should request the manufacturer's certificate of analysis and lot-to-lot density data before setting production acceptance limits.