| HS Code | 352773 |
| Manufacturer | DuPont |
| Brand | Sclairfilm |
| Grade | GL-1 |
| Productname | DuPont™ Sclairfilm® GL-1 LLDPE Film, Laminating, 76 µm Thickness |
| Producttype | LLDPE Film |
| Material | Linear Low Density Polyethylene (LLDPE) |
| Function | Laminating |
| Thickness | 76 µm |
| Density | 0.92 g/cm³ |
| Meltingpoint | 120-125 °C |
| Tensilestrength | 25-35 MPa |
| Elongationatbreak | 500-700% |
| Tearstrength | 200-500 g |
| Haze | 5-10% |
| Gloss | 70-90 |
| Coefficientoffriction | 0.2-0.4 |
| Heatsealable | Yes |
| Surfacetreatment | Corona treated |
| Appearance | Transparent |
| Color | Clear |
| Form | Roll |
| Application | Flexible packaging lamination |
As an accredited DuPont™ Sclairfilm® GL-1 LLDPE Film, Laminating, 76 µm Thickness factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Supplied as one roll per carton, the 76 µm DuPont™ Sclairfilm® GL-1 LLDPE laminating film is individually packaged. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with palletized DuPont™ Sclairfilm® GL-1 LLDPE laminating film, 76 µm; dry, secured, ambient, moisture-protected, no stacking. |
| Shipping | DuPont™ Sclairfilm® GL-1 LLDPE Film, Laminating, 76 µm, ships as non-hazardous film rolls on pallets, stretch-wrapped and secured. Store cool, dry, ventilated, away from sunlight, heat, ignition, moisture, dust, and sharp objects. Transport in covered trucks; avoid compression and temperature extremes. No special hazard classification. |
| Storage | Store at ambient room temperature in a cool, dry, well-ventilated area away from direct sunlight, heat, sparks, and ignition sources. Keep sealed in original packaging until use. Protect from moisture, dust, oils, solvents, oxidizers, and physical damage. Do not crush or stack heavy objects on rolls. Maintain moderate temperature and humidity; avoid extreme conditions. Follow manufacturer’s storage guidance. |
| Shelf Life | Shelf life is 24 months from date of manufacture when stored in original packaging in a cool, dry, well-ventilated area, away from sunlight. |
In dry-bond retort pouch structures, DuPont™ Sclairfilm® GL-1 LLDPE Film, Laminating, 76 µm Thickness is placed as the inner sealant web adjacent to a 9 µm aluminium foil barrier and a reverse-printed 12 µm polyester outer web. The three-layer build is processed on a solventless adhesive laminator equipped with a 3-roll application station; adhesive coat mass is held between 1.6 g/m² and 2.0 g/m², and the laminated reel is cured at 45 °C for 72 h before slitting. Heat seal performance of the 76 µm LLDPE layer is evaluated per ASTM F88/F88-21 using a 25 mm wide specimen with jaw pressure of 0.3 MPa; on production impulse sealers, plateau seal strengths above 120 °C jaw temperature are typically recorded from 18 N/25 mm to 25 N/25 mm for LLDPE/foil/PET laminates, though published data for this specific film grade is limited. Hot tack, measured under ASTM F1921-18, should be verified on the actual packaging line because dwell time and cool-back distance on rotary band sealers can shift the hot-tack window by ±10 °C. Regulatory compliance for food contact follows FDA 21 CFR 177.1520(c) for olefin polymers and European Commission Regulation (EU) No 10/2011; the finished laminate must meet an overall migration limit of 10 mg/dm² in food simulant D2 at 121 °C for 30 min when retorting is specified. The terminal pouch is a retortable ready-to-eat meal pack processed at 121 °C for 30 min in water-immersion retort equipment with counterpressure of 0.18 MPa, after which visual inspection per ASTM F1886/F1886-22 is used to reject channel leakers.
In medical device sterile barrier systems conforming to ISO 11607-1:2019, the 76 µm GL-1 LLDPE film functions as a lamination sealant web against medical-grade paper or Tyvek. The converter applies a two-part polyester-polyurethane adhesive at 2.5 g/m² to 3.0 g/m² dry coat mass using a gravure cylinder with 140 lines/cm screen and 60–70 °C three-zone drying. Lamination nip temperature is maintained at 65 °C, and finished reels are post-cured at 35 °C and 50% RH for 5 days. The seal curve generated on a laboratory heat sealer per ASTM F88/F88-22 must demonstrate a predictable peel transition from 105 °C to 140 °C, with no film splitting below 2.0 N/15 mm. Pouches are subjected to ethylene oxide sterilization under ISO 11135:2014, typically at 55 °C and 30–60% RH with a dwell of 2 h, followed by aeration for 12 h at 40 °C. For gamma sterilization, process validation per ISO 11137-1:2006/Amd 1:2013 uses a dose of 25 kGy to 40 kGy, and the film must be checked for embrittlement by tensile elongation retention per ASTM D882-18; published data for this specific film after gamma irradiation is limited, so dose mapping must be performed on finished pouch configurations. Cytotoxicity of the final laminate is screened per ISO 10993-5:2009 and ISO 10993-12:2012 using cell culture extraction at 37 °C for 24 h. The terminal converted product is a form-fill-seal pouch for syringes or catheters, sealed at 125 °C, 0.4 MPa, and 0.8 s dwell on rotary equipment, with visual seal width controlled between 6 mm and 10 mm.
Laminated structures for liquid herbicide, fungicide, and water-soluble fertilizer sachets often position the 76 µm GL-1 LLDPE film as the sealing layer inside a reverse-printed biaxially oriented polyamide or metallized polyester barrier. The conversion route uses a two-component solvent-based polyurethane adhesive at 2.0–2.5 g/m² dry weight, applied on a comma-blade coating head and dried through a four-zone oven with temperatures from 50 °C to 90 °C. The filled sachet must withstand a 1.0 m drop test per ISTA 3A and a burst test of 30 kPa per ASTM F1140/F1140-21 without seal delamination. Environmental stress crack resistance is relevant because agricultural active ingredients contain aromatic solvents and surfactants; LLDPE sealant layers are selected for short-chain branch distribution that reduces crack propagation under ASTM D1693-21 constant-strain conditions, but the end user must pre-test each formulation at 50 °C for 14 days because published compatibility data for this specific film grade is limited. The lamination process should maintain a film web tension of 0.8 N/mm to 1.2 N/mm on a centre-driven unwind to avoid transverse gauge banding that can open channels in vertical form-fill-seal corners. Seal integrity is verified per ASTM F2338-09(2020) using a vacuum decay pressure differential of 4.6 kPa, while leak detection on the fill line uses a pressure decay threshold of 5% over 5 s. The terminal product is a single-dose crop protection sachet with seal width of 8 mm, processed on a stick-pack VFFS machine at 60 packs/min and hot-bar temperature of 130 °C.
The regulatory status for the three lamination routes described above is consolidated into a single control matrix. The matrix lists the binding acceptance criteria that a converter must verify on each new substrate combination.
| Application route | Reference method | Test condition | Acceptance limit |
|---|---|---|---|
| Retortable food pouch | ASTM F88/F88-21, ASTM F1921-18, EU 10/2011 | Seal jaw 120–140 °C, simulant D2 121 °C 30 min | Seal strength ≥ 18 N/25 mm; overall migration ≤ 10 mg/dm² |
| Medical sterile barrier | ISO 11607-1:2019, ASTM F88/F88-22, ISO 10993-5:2009 | Peel 105–140 °C; gamma 25–40 kGy | Peel ≥ 2.0 N/15 mm; no cell lysis above grade 2 |
| Agricultural chemical sachet | ASTM D1693-21, ASTM F1140/F1140-21, ASTM F2338-09(2020) | 50 °C 14 days; burst 30 kPa | No failure in 10 specimens within 48 h; no leak at 4.6 kPa |
Thermal lamination of printed paper, book covers, and identification cards uses the 76 µm GL-1 LLDPE film as a protective overlay after corona treatment. The laminating line is configured with a chrome-plated steel roll at 135 °C and an 80 Shore A rubber backing roll, with nip pressure held at 0.4 MPa and line speed from 12 m/min to 18 m/min. Under these conditions the film softens sufficiently to flow into paper fibre interstices, producing peel adhesion to coated paper that is measured per ASTM D1876-23 with a 25 mm strip; values below 2.0 N/25 mm indicate insufficient thermal penetration and require either an increase in roll temperature of +5 °C or a reduction in line speed of 2 m/min. Edge trimming is performed with rotary slitting blades set to a side trim of 3 mm, and rewind tension is capped at 0.6 N/mm to prevent blocking on the hard chrome surface. Compliance for graphic arts applications follows REACH obligations for substances of very high concern and, where the laminated article is used in children’s books, EN 71-3:2019+A1:2021 migration limits for nine trace elements. The finished printed product is a menu card, technical manual cover, or personnel identification badge with a total thickness increase of 76 µm and single-film optical haze measured per ASTM D1003-21 below 5%.
In reflective insulation facings for HVAC ductwork and pipe insulation, the 76 µm GL-1 LLDPE film is laminated to aluminium foil or metallized polyethylene terephthalate to form a vapour barrier and abuse-resistant outer ply. The process runs on a solventless laminator with a two-component polyurethane adhesive at 1.8 g/m² applied via a five-roll heated coating head at 40 °C, followed by lamination nip at 60 °C and a 24 h cure at 30 °C. Water vapour transmission of the finished laminate is measured per ASTM F1249-20 at 38 °C and 90% RH; for a laminated foil structure, the barrier is diffusion-limited by the foil, but pinholes introduced by thermal expansion during lamination can raise the transmission rate above 0.1 g/m²/day, so pinholing is checked with a light box per ASTM F1886/F1886-22 on 1 m² samples. The LLDPE layer must also pass a low-temperature flex test at -20 °C for 500 cycles using a Gelbo flex tester to screen for crack formation, because HVAC exterior runs can cycle from -15 °C to 65 °C within a single day in arid climates. Flammability of the facing product is assessed per ASTM E84-23 with a flame spread index of 25 or less and smoke developed index of 50 or less where local mechanical codes require Class A facings. The terminal product is a reinforced insulation facing roll with width of 1.2 m, sold in lengths of 50 m, and bonded in the field with a 75 mm overlap using pressure-sensitive tape.
Vertical form-fill-seal packaging for frozen vegetables and IQF seafood uses the 76 µm GL-1 LLDPE film as the sealant ply in a duplex or triplex lamination with oriented polypropylene or polyethylene terephthalate. The converter laminates the film at a line speed of 180 m/min with solventless adhesive at 1.5 g/m²; curing continues for 48 h at 35 °C. The packaging line operates at 80 packs/min with jaw temperature of 135 °C and jaw pressure of 0.35 MPa. Cold-temperature seal strength is checked per ASTM F88/F88-22 after conditioning the sealed pouch at -18 °C for 24 h; a minimum of 12 N/25 mm is required because frozen distribution subjects the seal to flexural stresses during pallet stacking. Puncture resistance is tested per ASTM F1306-21 using a 0.5 mm probe at 305 mm/min, with a pass threshold of 15 N for the finished lamination; this property is relevant for IQF shrimp and mixed vegetable packs containing sharp ice crystals. Compliance follows FDA 21 CFR 177.1520(c) and EU 10/2011, but the converter must confirm that the adhesive system is not a source of primary aromatic amines above 0.01 mg/kg in the final article. The terminal package is a 750 g pillow pack with a lap seal width of 10 mm, transferred directly to a spiral freezer at -30 °C and held for 20 min before case packing.
Competitive DuPont™ Sclairfilm® GL-1 LLDPE Film, Laminating, 76 µm Thickness prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
DuPont™ Sclairfilm® GL-1 is a linear low-density polyethylene film supplied at 76 µm nominal thickness (0.076 mm, approximately 3.0 mil) and classified for laminating applications. The grade name GL-1 identifies a laminating web rather than a shrink, overwrap, or coextruded sealant film. Because public technical data for this specific configuration is limited, the supplier certificate of analysis must be treated as the controlling source for density, melt-flow rate, additive package, tribological data, and corona-treatment level. In a converted laminate, the GL-1 web generally functions as an inner ply or sealant layer behind a dimensionally stable front web such as poly(ethylene terephthalate), oriented polyamide, or biaxially oriented polypropylene. The product contributes toughness and sealant functionality; it is not marketed as a barrier polymer and does not replace polyvinylidene chloride, ethylene vinyl alcohol, or aluminium foil in high-barrier constructions.
In duplex and triplex flexible packaging structures, a 76 µm LLDPE web changes roll-handling and converting economics compared with a 12 µm or 15 µm oriented polyester front web. LLDPE exhibits a comparatively low elastic modulus and high elongation at yield; on slitter-rewinders and laminators, the film therefore demands lower unwind and rewind taper tension than oriented polyester or biaxially oriented polypropylene. Without such compensation, thin-gauge LLDPE rollstock can develop telescoped rolls, baggy edges, or repeat-length drift during coating. Because the public literature does not provide the tensile modulus of GL-1 specifically, incoming lot data under ASTM D882 should be compared with the incumbent web before setting machine parameters.
Because the film is a polyethylene laminating web and not a barrier film, oxygen and water-vapour transmission rates will be higher than those of aluminium foil, metallized polyester, polyvinylidene chloride-coated films, or EVOH-containing structures. If a package requires moisture or oxygen barrier, the GL-1 web must be paired with an appropriate barrier front or middle web. Water-vapour transmission of the unsupported film may be measured by ASTM F1249; oxygen transmission may be measured by ASTM D3985. Those values are relevant only for shelf-life modeling of the entire finished structure, not as stand-alone performance indicators.
Storage history is an incoming quality parameter. Corona treatment on polyethylene decays through surface-energy relaxation and migration of low-molecular-mass species; a roll stored at elevated warehouse temperature may meet the original dyne specification at goods receipt and still fail on the laminator after a delay of several days. A converter should therefore re-check the corona-treated surface immediately before coating with ASTM D2578. Condensation created by moving cold rollstock into a warm, humid converting hall also reduces effective surface energy; a dew-point management protocol is a practical operational boundary. Published storage-time data for this GL-1 configuration is limited, so qualification under the converter’s own warehouse temperature and relative humidity conditions is required.
Nominal thickness is a sales value; the actual process control is based on average gauge, transverse profile, and the location of repeated high spots. Film thickness may be measured according to ISO 4593 or ASTM D6988. At 76 µm, a one-micrometer deviation is 1.3% of nominal gauge. A uniform overall drift is generally less damaging than a repeating gauge band produced by die-lip fouling, chill-roll vibration, or worn haul-off rolls, because a repeating band creates periodic adhesive thickness variation and differential winding hardness. The supplier lot certificate should be read for average thickness, transverse maximum-minimum range, and graphical profile before the roll is accepted.
For adhesive lamination, the functional surface parameter is wetting tension. Corona-treated LLDPE rollstock is commonly specified at a minimum 38 mN/m using ASTM D2578. Insufficient treatment produces adhesive de-wetting and low peel strength; excessive treatment can create a brittle oxidized surface and increase the risk of roll blocking. The adhesive supplier’s documented lower and upper dyne limits are the controlling process window, not a generic film-industry rule. Because LLDPE treatment decays with time, edge and center checks should be taken no earlier than the shift in which the roll is to be coated.
If a migrating slip package is present in GL-1, coefficient of friction values determined by ASTM D1894 or ISO 8295 can change with roll aging and temperature. For laminating webs, a high level of slip additive on the non-coated surface can transfer to idler rollers and reduce machine-direction traction; on the coated surface, blooming amides may weaken adhesion if the film is not retreated. Published additive data for this GL-1 grade are limited, so roll-handling settings should not be based on coefficient-of-friction figures from a different Sclairfilm product or a generic LLDPE supplier datasheet.
Roll geometry, static-charge build-up, and tension-control architecture also determine whether the web can be processed at production speed. A 76 µm LLDPE web can accumulate static charge on the unwind and transport sections of the laminator; static dissipators are typically placed before the corona treater and before the coating head. Thin-gauge LLDPE is more elongation-prone than polyester or polyamide, so ultrasonic or line-scan tension measurement provides more stable control than a simple dancer assembly. During acceleration or splice cycles, rapid tension spikes can create micro-waviness, adhesive skip, or baggy edges that remain visible in the finished laminate.
In extrusion lamination, the function of the GL-1 web is to supply a finished sealant surface rather than to be melt-extruded. The web passes through the nip with a molten polyethylene tie layer; the corona-treated side is presented to the interface in most constructions. If the treatment level is below the molten-resin supplier’s recommended threshold, the film may show poor interlaminar bond; if the treatment level is too high, surface oxidation can reduce sealant performance on the outward side. The laminator operator should therefore distinguish between the corona-treated side and the slip-treated reverse side before web path alignment.
At the same nominal gauge, LLDPE film generally displays higher elongation at break and higher protrusion puncture resistance than high-pressure LDPE when measured under ASTM D882 and ASTM D5748. The linear molecular architecture of LLDPE distributes mechanical stress through short-chain branches, whereas high-pressure LDPE has long-chain branching and can localize strain more readily during puncture events. High-pressure LDPE, however, is often specified for blown-film clarity and easier extrusion processing. Whether GL-1 matches the haze and gloss of a high-pressure LDPE laminating web must be verified using ASTM D1003 and ASTM D2457, because the lamination adhesive layer can hide but not eliminate base-film optical differences.
Heat-seal behavior is a critical substitution criterion. LLDPE films can exhibit a broader hot-tack plateau than high-pressure LDPE, but the actual seal initiation temperature, plateau width, and hot-tack strength depend on comonomer type, density, and additive package. The supplier should be requested to provide seal data determined under ASTM F88/F88M and ASTM F1921 for the GL-1 grade before form-fill-seal jaw temperatures and dwell settings are fixed. If no published data exists for this specific configuration, sealing process development should be conducted on the actual laminating line rather than by analogy to another LLDPE film.
Within the Sclairfilm product family, GL-1 is differentiated by its laminating designation and 76 µm gauge. A Sclairfilm film sold for shrink, overwrap, or general packaging use may have a different surface treatment, slip and antiblock loading, or winding finish. A processor cannot assume interchangeability based on thickness alone; the supplier should confirm that the lot was dressed for lamination and that the winding side orientation is correct for the intended coating deck.
Optical performance is another area where substitution should be checked on the finished laminate rather than on the base film alone. A 76 µm LLDPE web generally has different optical characteristics from a cast polypropylene laminating web. The adhesive may fill some surface roughness but can also introduce its own haze after cure. Acceptance limits should therefore be written for the clear duplex or triplex laminate using ASTM D1003 and ASTM D2457, not for the unsupported film.
For a reference LLDPE density of 0.920 g/cm³, the nominal basis weight of a 76 µm film is 69.9 g/m², with an approximate area yield of 14.3 m²/kg. The actual basis weight is calculated from the lot-specific density in the certificate of analysis. This conversion is useful when estimating roll length, finished package weight, or adhesive coverage across large production campaigns.
Solventless polyurethane adhesive systems apply a very low adhesive film, typically in the range of 1.5 g/m² to 2.5 g/m² depending on the structure. At these coating weights, the surface topography of a 76 µm LLDPE web can influence bond uniformity. A film with high haze, rough chill-roll texture, or heavy antiblock may need a higher coat weight or a change in surface treatment to maintain the same peel strength. Surface checks should be made at both edges and the center immediately before the coating station using ASTM D2578; preferential treatment decay often appears at roll edges exposed to ambient storage conditions.
On a solventless laminator, web tension and acceleration ramps are more critical with LLDPE than with oriented PET or oriented polyamide. Because LLDPE elongates at low tensile stress, rapid speed changes during splice phases can produce transient elongation that alters the adhesive coating register and final roll hardness. The unwind brake, laminating nip, and rewind axis should be tuned as a closed-loop tension control system; a converter may need to reduce acceleration jerk limits below those used for a 12 µm polyester web. If the film carries a migrating slip additive, the film side to be coated should be the corona-treated side specified for lamination, and the reverse side should be assessed for coefficient of friction using ASTM D1894 to ensure the finished roll can pass through bagmaking and form-fill-seal operations.
Adhesive selection is outside the film datasheet, but a boundary condition applies. Some solventless and solvent-based adhesives contain amine catalysts or co-reactants that can interact with oxidized polyolefin surfaces; whether such interactions are relevant for a given GL-1 treatment level must be evaluated by peel-strength testing under ASTM F904 or ASTM D1876. The film itself is polyethylene and is generally resistant to many adhesive solvents, but solvent retention in the laminate can soften the LLDPE surface and should be controlled by the adhesive supplier’s coating and drying parameters.
The following non-exhaustive methods are commonly used in incoming quality control and laminate qualification. The presence of a standard in this table does not itself certify a particular GL-1 lot; certification must be obtained from the supplier’s regulatory and lot-specific documentation.
| Standard / Method | Property | Incoming inspection function |
|---|---|---|
| ISO 4593 / ASTM D6988 | Film thickness | Average gauge, transverse profile, high-spot detection |
| ASTM D882 | Tensile properties | Machine-direction and transverse-direction strength, elongation, modulus comparison |
| ASTM D2578 | Wetting tension | Corona-treatment level before adhesive coating |
| ASTM D1894 / ISO 8295 | Coefficient of friction | Slip consistency in bagmaking and packaging |
| ASTM D1003 | Haze | Optical quality after lamination |
| ASTM D2457 | Gloss | Surface appearance on exposed layers |
| ASTM D5748 | Protrusion puncture resistance | Toughness of sealant ply |
| ASTM F88/F88M | Seal strength | Heat-seal performance after lamination |
For food-contact applications, a polyethylene-rich film may be evaluated under 21 CFR 177.1520 for the United States and EU Regulation No 10/2011 for the European Union, provided that the specific grade and its additive package fall within the supplier’s positive-list declaration. The final laminated structure, including adhesive, ink, and any secondary web, is a separate regulatory article and must be assessed under the relevant migration or extraction protocols. The film’s polyethylene base does not remove the need for total migration testing if the package contains fatty, aqueous, acidic, or alcoholic food simulants selected under EU Regulation No 10/2011 or the applicable national standard.
Operational boundaries for GL-1 should be taken from the supplier certificate of analysis. General polyethylene handling rules apply: the film should not be stored in direct contact with strong oxidizing agents, should not be exposed to corona higher than the recommended treatment level, and should not be processed with wet rolls after cold-room or refrigerated transport. For retort, dry-heat sterilization, or aggressive chemical packaging, suitability must be validated on the finished laminate; a 76 µm LLDPE laminating web is not by itself a high-temperature barrier or a retort-grade structure. Because published data for this specific configuration is limited, existing laminating recipes should be revised only after comparing lot-specific tensile, thickness, surface-treatment, and seal data with the incumbent film.