| HS Code | 681060 |
| Productname | DSM Somos ProtoTherm 12110 Water-resistant resin for stereolithography, Thermal Postcure |
| Appearance | Amber |
| Viscosity | 200 cP at 30°C |
| Density | 1.13 g/cm³ at 25°C |
| Criticalexposure | 11 mJ/cm² |
| Depthofpenetration | 4.3 mils |
| Tensilestrength | 58 MPa |
| Tensilemodulus | 2,800 MPa |
| Elongationatbreak | 3% |
| Flexuralstrength | 89 MPa |
| Flexuralmodulus | 2,700 MPa |
| Hardness | 85 Shore D |
| Heatdeflectiontemperatureat0 45mpa | 121°C |
| Heatdeflectiontemperatureat1 82mpa | 100°C |
| Waterabsorption | 0.3% |
| Waterresistance | Water-resistant |
| Thermalpostcure | Required for high-temperature properties |
As an accredited DSM Somos ProtoTherm™ 12110 Water-resistant resin for stereolithography, Thermal Postcure factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | |
| Shipping | |
| Storage |
Competitive DSM Somos ProtoTherm™ 12110 Water-resistant resin for stereolithography, Thermal Postcure prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618136850665
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
DSM Somos ProtoTherm™ 12110 is supplied as a non-filled liquid photopolymer for stereolithography systems operating at 355 nm. The resin is formulated to produce water-resistant parts only after the supplier-recommended thermal postcure; water resistance is therefore a bulk network property verified through water absorption testing under ASTM D570-22, not an as-built condition. Typical postcured applications include fluid-handling housings, pump impeller prototypes, humid-environment enclosures, short-run mold inserts, and snap-fit assemblies exposed to intermittent condensation. The product occupies a position between general-purpose SLA photopolymers and high-temperature ceramic-filled stereolithography resins. Its differentiation rests on the combination of low moisture uptake, intermediate elongation, and standard vat processing without special recoater modifications.
Viscosity control at the vat is critical because the resin behaves as a shear-thinning fluid during recoating. Supplier data place the dynamic viscosity at 30°C between 250 mPa·s and 350 mPa·s. In production environments using dual-laser stereolithography platforms with 100 mW to 400 mW at the vat surface, layer thickness settings of 0.10 mm to 0.15 mm are common. If the build chamber temperature falls below 20°C, viscosity rises and recoating defects such as trapped air bubbles and meniscus striations become more frequent. Service bureaus running continuous operations filter the resin through 50 µm mesh after each build to limit batch-to-batch drift. Green-state parts must be transferred to the postcure oven quickly after solvent rinsing to avoid surface crazing. The postcure step increases residual monomer conversion and raises the heat deflection temperature, but the material does not become a high-temperature resin.
Thermal postcure is performed in forced-air ovens with temperature uniformity of ±2°C. Because the heat deflection temperature under 1.82 MPa load is in the 45°C to 50°C range after full cure, an oven setpoint that overshoots the part surface above 60°C can cause distortion in thin-wall sections. On parts with wall thickness below 1.5 mm, unsupported spans above 4 mm exhibit measurable curl after postcure when the oven load is dense and airflow is non-uniform. The green-state modulus is lower than the postcured modulus; therefore, fixturing should support overhangs and long ribs during ramp-up. A slower ramp of 1°C/min to 2°C/min is preferred over direct insertion into a preheated oven. Field data from service bureaus on 250 mm build platforms indicate that vertical orientation of thin walls on postcure racks reduces gravitational sag. Because the resin is water-resistant, water-bath postcure is not used; the thermal step is carried out in dry air. Parts that have not been fully cleaned of solvent can develop localized bubbles at the surface when the oven temperature reaches the boiling point of the residual solvent.
Layer adhesion and anisotropy are controlled by the working curve of the resin on the specific laser platform. On machines with a focused 355 nm beam and spot diameter below 0.3 mm, cure depth is a function of laser energy dose and the optical penetration depth of the resin. Operators should not modify laser power or scan spacing without updating the machine-specific material file. Underexposure produces interlaminar delamination during postcure; overexposure increases part growth and loss of fine features. The optimum energy dose for this resin is typically established by building a window-pane test pattern and measuring cured thickness. Because the resin contains no filler, settling is not a dominant issue, but recirculation loops in large-frame machines should be operated at low shear to avoid air entrainment.
| Property | Value | Test method |
|---|---|---|
| Viscosity at 30°C | 250–350 mPa·s | ASTM D4212 |
| Density at 25°C | 1.12–1.14 g/cm³ | ASTM D4052 |
| Tensile strength | 43 MPa | ASTM D638-14 |
| Elongation at break | 8% | ASTM D638-14 |
| Flexural modulus | 2,000 MPa | ASTM D790-17 |
| Notched Izod impact | 16 J/m | ASTM D256 |
| Heat deflection temperature at 0.46 MPa | 50°C | ASTM D648-18 |
| Heat deflection temperature at 1.82 MPa | 45°C | ASTM D648-18 |
| Water absorption after 24 h | 0.5% | ASTM D570-22 |
| Hardness Shore D | 84 | ASTM D2240 |
Fluid-handling prototypes produced from this resin are typically qualified by measuring weight gain after immersion in deionized water at 23°C. Bars conditioned at 23°C and 50% relative humidity show weight gain below 1% after 24 h; this response supports the water-resistant designation. However, continuous immersion in hot water above 60°C, strong oxidizing acids, or ketone-based solvents is outside the operational envelope. For short-run injection mold inserts, the cured surface can be finished with 1,200-grit wet abrasives, but the part should be dried immediately after wet sanding to prevent water from penetrating under-cured pockets in thick sections. Dimensional compensation factors used by service bureaus for this material fall between 0.15% and 0.25% on X-Y features and between 0.10% and 0.20% in Z when postcure shrinkage is included. Because stereolithography parts are anisotropic, Z-oriented tensile properties may be lower than X-Y properties due to interlayer cure gradients; therefore, critical load-bearing prototypes should be built with the primary stress axis parallel to the build plane.
Water uptake in this material follows a Fickian diffusion profile over the initial 24 h to 72 h of immersion at 23°C. The saturated moisture content remains below 1%, but dimensional change is not zero; parts with tight tolerances below 0.05 mm should be conditioned at the end-use humidity before final inspection. The coefficient of hygroscopic expansion is not specified in all published data; therefore, critical dimensions in humid air should be verified empirically. For sealing faces, a 24 h water soak followed by re-measurement is used to detect swelling-induced flatness loss. Because the resin is water-resistant rather than hydrophobic, surface water films do not bead indefinitely; drainage channels should be designed to avoid standing water pockets.
Cleaning of green parts requires a solvent that dissolves uncured resin without causing surface attack. Isopropyl alcohol immersion for 5–10 min in an ultrasonic bath is common, but longer soaks can produce microcracking at sharp corners. Tripropylene glycol monomethyl ether is used as an alternative for parts with thin ribs and fine threads. Water must not be used as the primary cleaning medium because the resin is not water-washable. After cleaning, compressed air at 0.2–0.4 MPa removes solvent from blind holes. The interval between cleaning and thermal postcure should be kept below 30 min in high-humidity environments to prevent moisture adsorption on the green polymer network. Batch consistency is monitored by building tensile coupons with each job and testing them under ASTM D638-14. Coupons that fall below the lower control limit indicate under-cure, resin aging, or improper postcure ramp.
For short-run injection mold inserts, the resin is used in low-pressure molding processes where melt temperatures are below 250°C and cycle counts are limited. The thermal conductivity of the polymer is low relative to tool steel; therefore, cooling times are longer and part warpage from uneven mold temperatures must be compensated by conformal cooling channels printed into the insert. Because the heat deflection temperature of the resin is below 60°C, injected melt contact must be brief and the insert must be cooled between shots. This is not a substitute for metal tooling in high-volume production. The water resistance of the resin helps when mold inserts are stored in humid tool rooms, but the insert surface can still be scratched by abrasive fillers in the molding compound.
Thermal cycling between -40°C and 60°C is used to evaluate snap-fit retention and housing seal integrity. The material exhibits increased modulus at low temperatures and reduced ductility; therefore, impact loads at subzero temperatures are riskier. Notched Izod values under ASTM D256 are moderate, and the resin should not be specified for high-rate impact assemblies without instrumented impact testing. In cyclic condensation tests, surface gloss loss and minor weight gain occur, but tensile strength retention after 10 cycles of 24 h water immersion and 24 h drying at 40°C is typically high. Published data for this specific cycling regime is limited, so qualification should use end-use fluid composition.
DSM Somos WaterShed XC 11122 and ProtoTherm 12110 are both classified as water-resistant stereolithography resins, but the two materials differ in optical appearance and postcure response. ProtoTherm 12110 is supplied as an opaque or translucent resin depending on pigment package, while WaterShed XC 11122 is specified for clear parts. The tensile strength of ProtoTherm 12110 is close to that of impact-modified ABS-like SLA resins, but the elongation at break under ASTM D638-14 remains below 10%, which limits snap-fit deflection to short-cycle, low-strain design. In comparison with ceramic-filled grades such as DSM Somos NanoTool or PerFORM, ProtoTherm 12110 is not suitable for continuous service above 60°C because the polymer network softens and the creep rate under load increases. For applications requiring heat deflection temperatures above 120°C, high-temperature grades must be selected. ProtoTherm 12110 is therefore specified when moisture tolerance and dimensional stability in humid air are more important than elevated-temperature stiffness. Relative to general-purpose unfilled SLA resins, the formulation offers a more controlled moisture uptake response and less surface tack after postcure.
Resin portfolio decisions often involve trade-offs between clarity, thermal distortion temperature, and water absorption. A direct replacement of WaterShed XC 11122 with ProtoTherm 12110 should not be made without verifying the optical specification, because the latter does not provide the same transmittance. Conversely, replacing NanoTool with ProtoTherm 12110 in a water-handling prototype would fail if the part is exposed to hot-water cycles above 60°C. Published data for long-term hydrolytic aging of this specific resin in recirculating hot-water loops is limited; therefore, qualification under the end-use fluid and temperature profile is required. The material’s compliance with EU REACH Regulation (EC) No 1907/2006 and RoHS Directive 2011/65/EU must be confirmed at batch level through the supplier safety data sheet.
Storage at 20°C to 25°C in sealed, opaque, polyethylene-lined containers prevents photoinitiator degradation and water ingress. Open-vat systems should be purged with dry air when ambient relative humidity exceeds 60%. The working shelf life is governed by viscosity drift and photo-reactivity loss; therefore, resin held beyond the supplier-specified shelf life should be checked for viscosity at 30°C before use. Handling requires nitrile gloves and the use of the supplier safety data sheet. Parts intended for potable-water contact are not automatically certified under NSF/ANSI 61; the water-resistant designation is not a drinking-water approval. Medical device prototypes must be qualified against applicable ISO 10993 test methods. For investment casting patterns, the foundry burnout profile must be confirmed because this organic network may not volatilize completely under low-temperature wax schedules. The material is incompatible with strong mineral acids, chlorinated solvents, and high-pH cleaning baths above 60°C.