    Specifications
    HS Code 280392
    Resin Type Ceramic-filled stereolithography resin
    Cured Color Off-white
    Liquid Density 1.38 g/cm³ at 25°C
    Viscosity 1,200 cps at 30°C
    Tensile Strength 65 MPa
    Tensile Modulus 10,500 MPa
    Elongation At Break 1.0%
    Flexural Strength 115 MPa
    Flexural Modulus 10,000 MPa
    Hardness 95 Shore D
    Heat Deflection Temperature 250°C at 0.45 MPa
    Glass Transition Temperature 100°C
    Water Absorption 0.3%
    Critical Exposure 12 mJ/cm²
    Penetration Depth 0.14 mm
    Postcure UV and thermal postcure required

    As an accredited DSM Somos NanoTool™ Resin for Stereolithography, UV & Thermal Postcure factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing
    Shipping
    Storage
    Free Quote

    Competitive DSM Somos NanoTool™ Resin for Stereolithography, UV & Thermal Postcure prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    DSM Somos NanoTool™ resin for stereolithography, UV & thermal postcure is a mineral-filled, opaque photopolymer formulated for 355 nm laser-based stereolithography systems. The uncured liquid exhibits high low-shear viscosity and requires heated vat conditioning plus positive recirculation to prevent filler stratification. In the as-built green state, parts possess only limited handling integrity; the manufacturer’s published mechanical values are conditional on a two-stage post-processing sequence that combines UV irradiation with a ramped thermal cure. The cured network occupies a specific performance position between unfilled high-temperature SLA resins and machined tooling boards, with a flexural modulus above 9,000 MPa and a heat deflection temperature at 0.46 MPa above 200 °C when tested according to ASTM D648-18.

    Why Does the Postcure Sequence Rather Than Build Parameters Determine Failure Resistance?

    The UV stage initiates radical propagation and partially consumes acrylate and epoxy functions, but the mineral filler restricts chain mobility, leaving residual reactive groups trapped in the semicured matrix. Thermal postcure supplies the activation energy for secondary crosslinking, densifies the network, and relaxes interfacial stress concentrations at the filler–polymer boundary. Tensile specimens built or machined to Type I geometry and tested under ASTM D638-14 after complete postcure exhibit an elongation at break of approximately 1.0 %. The low elongation is the expected consequence of a densely crosslinked, heavily filled network, not an artifact of incomplete polymerization. Tensile strength is approximately 68 MPa, and tensile modulus is approximately 10.2 GPa. Flexural properties tested under ASTM D790-17 show a flexural strength of approximately 107 MPa and a flexural modulus of approximately 9.4 GPa. The notched Izod impact value of approximately 12 J/m measured under ASTM D256-10 defines the product’s principal limitation in impact-loaded tool geometry.

    PropertyTest MethodNominal Postcured Value
    Tensile strength at breakASTM D638-1468 MPa
    Tensile modulusASTM D638-1410.2 GPa
    Elongation at breakASTM D638-141.0 %
    Flexural strengthASTM D790-17107 MPa
    Flexural modulusASTM D790-179.4 GPa
    Notched Izod impactASTM D256-1012 J/m
    Heat deflection temperature at 0.46 MPaASTM D648-18225 °C
    Cured densityASTM D792-201.70 g/cm³
    Water absorption after 24 h immersionASTM D570-980.3 %

    Lot-specific certificates of analysis supersede the representative values listed above. Dimensional and material performance should be confirmed on coupons built in the same orientation and postcure lot as the production parts.

    On 355 nm stereolithography platforms, layer spreading is strongly affected by the filled resin’s rheology. At the build vat temperature of approximately 30 °C, low-shear viscosity is typically greater than 2,000 mPa·s; this is several times the value of standard unfilled SLA photopolymers. Without adequate heating, the recoater blade cannot generate a uniform 0.100 mm layer, and the resulting thickness variation produces delamination or undercure. Idle vats develop sediment; production lines therefore recirculate the resin after downtime and verify filler distribution before starting high-value tool builds. The recirculation history influences cure depth because shear modifies the local filler concentration near the build surface. Process validation on production equipment has shown that consistent heat deflection temperature and flexural modulus require control of vat temperature, recoat speed, and idle-time stirring as a single parameter set.

    The thermal cure stage must be treated as a process control operation, not a superficial drying step. Thick sections can exotherm because residual polymerization enthalpy is released; when the heating rate exceeds the heat-transfer capacity of the part, internal cracking occurs. Ovens used for postcure therefore require active exhaust and temperature uniformity better than ±5 °C. A common industrial control approach is a ramp rate not exceeding 1 °C/min and a final hold in the range 150–200 °C, with the exact value selected from the current manufacturer’s technical data sheet for the part cross-section. The UV postcure is performed in a chamber with spectral output between 300 nm and 400 nm; exposure time is determined by measured irradiance rather than fixed clock time. Because the mineral filler scatters actinic radiation, cure depth at constant laser energy is lower than for transparent unfilled resins. Build parameters must therefore be derived from a dedicated window scan and not copied from other Somos resin profiles.

    When NanoTool Inserts Are Applied Against Glass-Filled Engineering Resins

    Short-run injection molding with unfilled polyolefins is the most commonly reported application for this resin. The high flexural modulus resists core deflection under packing pressure, and the high heat deflection temperature permits limited low-temperature molding without immediate softening. However, the notched Izod value of approximately 12 J/m imposes a design limit on unsupported core pins and sharp corners. Ejection should not apply tensile shock to features below 3 mm in cross-section; draft angles below increase the probability of brittle fracture. When glass-filled polyamide, polycarbonate, or polybutylene terephthalate is molded, the insert is exposed to abrasive filler wear and higher injection pressures. Published tool-life data for this specific configuration is limited; mold trials are required to establish shot counts before production quantities. The product should not be considered a direct substitute for P20 steel, aluminum, or machined epoxy tooling boards because its compressive strength, thermal conductivity, and fracture strain differ substantially. The selection difference from unfilled SLA resins is primarily the exchange of elongation and impact resistance for higher modulus and lower thermal expansion.

    Machined surfaces develop fine mineral dust that accelerates cutting-edge wear. Carbide tooling with reduced feed rates is specified to control edge chipping and breakout along boss and rib features. Because the material is brittle in thin sections, fixture clamping must distribute load over broad pads rather than point contacts. Embedded inserts and threaded features should be installed with low-viscosity adhesives selected for mineral-filled thermoset surfaces; interference fits that generate hoop stress are not recommended.

    Chemical Resistance Boundaries and Contamination Control

    Strong polar solvents, ketones, and alkaline aqueous cleaners degrade the crosslinked network and generate surface microcracking. Cleaning with isopropyl alcohol must follow the current manufacturer’s handling guide and be limited to the shortest duration capable of removing uncured resin. Extensive solvent contact lowers flexural strength measured under ASTM D790-17 and can initiate stress cracking at molded features. Cured water absorption after 24 h immersion is approximately 0.3 % under ASTM D570-98. Insert storage in high-humidity environments should be followed by drying before heating above 100 °C. The product must be handled as a solvent-sensitive, mineral-filled thermoset and is not recommended for components exposed to aggressive brake fluids, esters, or chlorinated solvents.

    Under chemical-management regulations, the material is supplied with safety data sheets and REACH documentation under EC 1907/2006; EU RoHS compliance is confirmed against Directive 2011/65/EU. Because cured SLA parts contain residual photoinitiator fragments, final-article compliance must be evaluated on the actual cured article rather than on the liquid resin alone. Quality control for this product relies on certificate-of-analysis values measured on postcured specimens, not on green-state inspection. Because the mineral filler affects ultrasonic and optical inspection contrast, non-destructive evaluation for internal porosity or delamination typically uses X-ray computed tomography or microsection analysis rather than visible-light inspection. Filler particle settling can create density gradients across a single build; critical inserts are therefore evaluated with flexural coupons from the same build envelope and tested under ASTM D790-17 or ISO 178:2019 to verify lot-level uniformity.

    Electrical connector prototype housings and master patterns for silicone tooling use the product for dimensional stability and high flexural modulus. The filled material is non-conductive and rigid, making it appropriate for dielectric test fixtures when surface resistivity and dielectric strength are verified under the relevant IEC or ASTM test method for the service voltage. Pattern machining must account for brittle edge chipping; low feed rates and sharp carbide cutters are used to reduce breakout along machined surfaces. Bonded assemblies require adhesives that can wet the mineral-filled cured surface, and joint design should avoid peel loads because the substrate cannot yield locally to redistribute stress.