Products

DSM Somos 7120 Epoxy Photopolymer, UV Postcure

    • Product Name: DSM Somos 7120 Epoxy Photopolymer, UV Postcure
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: admin@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    Specifications
    HS Code 584146
    Density 1.13 g/cm³
    Viscosity At 30 C 220 mPa·s
    Tensile Strength 54 MPa
    Tensile Modulus 2.76 GPa
    Elongation At Break 12%
    Flexural Strength 77.9 MPa
    Flexural Modulus 2.21 GPa
    Hardness Shore D 80
    Izod Impact Notched 0.48 J/cm
    Heat Deflection Temperature 60 °C
    Glass Transition Temperature 70 °C
    Water Absorption 0.35%
    Critical Exposure 9.7 mJ/cm²
    Penetration Depth 0.14 mm

    As an accredited DSM Somos 7120 Epoxy Photopolymer, UV Postcure factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing
    Shipping
    Storage
    Free Quote

    Competitive DSM Somos 7120 Epoxy Photopolymer, UV Postcure prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Within the class of stereolithography resins activated by a 355 nm solid-state laser and completed by a separate ultraviolet flood exposure, DSM Somos 7120 Epoxy Photopolymer, UV Postcure functions as a rigid general-purpose epoxy photopolymer. The liquid is a single-component cationic formulation; no thixotropic adjustment or accelerator addition is performed at the vat level. Manufacturer-published liquid-phase viscosity at 30 °C is typically 0.26 Pa·s, equivalent to 260 cP, and liquid density at 25 °C is reported as 1.13 g/cm³. The polymer network forms through ring-opening of epoxy groups initiated by photogenerated acid species, but laser-only conversion leaves a partially cured green state. The designation “UV Postcure” therefore indicates that full mechanical response and chemical resistance are achieved only after the built part is cleaned, dried, and exposed to broad-spectrum UV radiation in a flood chamber. Production uses include rigid prototype housings, master patterns for room-temperature vulcanizing silicone tooling, and investment casting patterns where the cured resin’s dimensional stability and ash characteristics are compatible with foundry processes.

    What Does the Separate UV Flood Exposure Contribute to the Cationic Epoxy Conversion Profile?

    In cationic photopolymerization, photoacid generation by the 355 nm laser pulse produces initiating species within the scanned line, but the network vitrifies rapidly at room temperature. Molecular mobility becomes restricted before all epoxy groups reach high conversion; the green part therefore contains unreacted monomer, low crosslink density, and reduced glass transition temperature. The UV postcure station supplies additional photons in the 320 nm to 390 nm band, usually with simultaneous moderate heating from the lamp cavity, to re-energize dormant chain ends and permit further ring-opening in the vitrified matrix. Manufacturer recommendations typically specify a postcure time of 30 min to 60 min per surface orientation, with larger masses requiring staged rotation to avoid shadowed regions. The effect of incomplete postcure is measurable through a reduction in heat deflection temperature and an increase in solvent uptake; tensile modulus may approach specification while impact strength and hot-wet performance remain depressed. Testing of cured coupons according to ASTM D618-21 at 23 °C and 50 % relative humidity is therefore required before comparing incoming resin batches or qualifying the postcure chamber.

    On a laser-based stereolithography system with a 355 nm source, the resin is typically processed at slice thicknesses between 0.050 mm and 0.100 mm. Thinner layers reduce stair-step artifact on shallow draft angles but multiply build time and recoating cycles; thicker layers increase productivity but produce larger surface discontinuities that must be filled or machined. The low liquid viscosity permits recoat blade travel with limited meniscus drag, but vat temperature should be maintained within the manufacturer-specified range, commonly near 30 °C, to control viscosity and leveling without initiating thermal dark-cure. After the build, the platform is raised and parts are drained before solvent cleaning. Cleaning solvents are selected to dissolve uncured surface resin without penetrating the green network; prolonged solvent immersion produces edge softening and dimensional drift. After cleaning, parts are dried at room temperature or with forced air before entering the UV postcure chamber. A staging fixture should rotate or invert the part so that down-facing surfaces and undercuts receive photon exposure; otherwise under-cured regions can creep under clamp load during downstream machining.

    PropertyTypical valueTest method
    Liquid viscosity at 30 °C0.26 Pa·s (260 cP)ASTM D2196-20
    Liquid density at 25 °C1.13 g/cm³ASTM D4052-22
    Tensile strength56 MPaASTM D638-14
    Tensile modulus2700 MPaASTM D638-14
    Elongation at break5.0 %ASTM D638-14
    Flexural strength84 MPaASTM D790-17
    Flexural modulus2450 MPaASTM D790-17
    Notched Izod impact22 J/mASTM D256-10
    Heat deflection temperature at 0.46 MPa64 °CASTM D648-18
    Heat deflection temperature at 1.82 MPa57 °CASTM D648-18
    Shore D hardness84ASTM D2240-15

    The table reproduces manufacturer-reported typical values as published in supplier technical documentation. These values are not guaranteed limits and are not to be used as design allowables without part-specific validation.

    Processing conflicts arise when the build chamber temperature drifts outside the recommended window. A low vat temperature raises viscosity and produces incomplete recoating, visible as voids on upper surfaces and delamination at layer boundaries; a high vat temperature shortens dark-cure shelf life and may accelerate premature cationic advancement in the vat. On platforms with a tilt-separation mechanism, large flat layers generate higher peel forces than narrow sections; supports should be distributed so that peel stress does not localize at part corners. Green parts are softer and more notch-sensitive than fully cured material, so support removal before UV flood exposure should use flush cutters rather than snapping. The postcure chamber must be monitored with a radiometer because lamp output decays over time; a drop below the lower end of the 320 nm to 390 nm band reduces through-thickness conversion even if surface dry time appears normal. For sections thicker than 6 mm, published data for this specific configuration is limited, and staged postcure with thermal equilibration is advised.

    Incoming batch verification on a production line often includes a viscosity measurement at 30 °C and a cure-depth test on a short build platform. Viscosity readings above the manufacturer acceptance range can sometimes be reduced by raising the vat temperature, but only within the stated maximum; batches with photo-speed drift may require exposure compensation through build software. The single-component cationic resin does not require mixing with an accelerator before charging the vat; however, resin left in an open vat for several days should be stirred gently to homogenize the photoacid generator and dissolved moisture content. Vat films or glass windows must remain free of polymerized crumbs because debris trapped under the recoat blade creates drag lines. These batch and equipment interactions are the main production-scale failure modes observed with epoxy photopolymers of this viscosity class.

    When Rigid Epoxy Accuracy Is Preferred Over ABS-Like Toughness or High-Heat Filled Resins

    In resin selection within the same stereolithography portfolio, DSM Somos 7120 is categorized by higher tensile modulus and lower elongation than ABS-like materials such as DSM Somos NeXt. The low elongation at break, near 5 %, means that snap-fit features and living hinges are not appropriate without stress-relief geometry; ABS-like resins can absorb greater strain before fracture. By contrast, high-temperature filled epoxies such as DSM Somos PerFORM shift heat deflection temperature above 200 °C and are selected for molding inserts or high-temperature wind-tunnel parts. The 7120 heat deflection temperature under a 0.46 MPa load is below 100 °C, making it unsuitable for applications where the part surface is exposed to boiling water, autoclave steam, or repeated solder reflow temperatures. Compared with optically clear resins such as DSM Somos WaterShed XC 11122, the 7120 product is not engineered for low moisture absorption or long-term water-service clarity. Its visible light transmission is lower, and absorbed water plasticizes the network; dimensional change can occur if the part is transferred from a dry room to a humid assembly floor without conditioning. In terms of post-processing, the UV postcure requirement is more stringent than for some laser-only acrylate systems, but the lower viscosity and vat stability make the 7120 formulation easier to recoat across large build zones. Users should not substitute 7120 for USP Class VI or ISO 10993-certified resins unless the intended device is evaluated under the relevant biocompatibility test plan.

    Moisture absorption affects the cured polymer through a measurable depression in heat deflection temperature and tensile modulus after prolonged humidity exposure. Parts held at relative humidity above 60 % should be dried at 40 °C to 50 °C before critical dimensional inspection or mechanical testing; the drying temperature must remain below the heat deflection temperature to prevent creep. The liquid resin is incompatible with free-radical acrylate initiators, strong nucleophiles, and organometallic curing agents not approved by the manufacturer; mixing with other resin families can arrest the cationic cure or generate nonuniform gelation. Vat equipment should be cleaned with the resin manufacturer’s recommended solvent and not with aggressive ketones or chlorinated solvents that can degrade seals and carry residue into subsequent builds. Because the uncured resin is a sensitizer, handling requires nitrile gloves, safety glasses, and local exhaust ventilation; cured parts are non-hazardous for ordinary handling but must not be ground or sanded without dust extraction. The product is subject to chemical inventory reporting under REACH Regulation EC No 1907/2006 and the RoHS Directive 2011/65/EU; a current safety data sheet and regulatory statement should be requested from the supplier for shipment-specific documentation.

    A specific production application is the fabrication of wind-tunnel test models for low-temperature aerodynamic campaigns. After stereolithography build and UV postcure, the surfaces are sanded and filled with a compatible epoxy primer; pressure taps are added by drilling and bonding metal or polymer tubing. The cured resin’s modulus and dimensional accuracy sustain machining, but the maximum stagnation temperature must be kept below the heat deflection temperature of 64 °C at 0.46 MPa. Models used in smoke-visualization tunnels may require additional sealing to reduce surface porosity and moisture uptake. In tooling use, 7120 master patterns are frequently used to cast room-temperature vulcanizing silicone cavities for polyurethane prototypes; the postcured epoxy pattern resists abrasion during demolding and holds dimensional tolerance when stored at stable humidity.

    Top