| HS Code | 582709 |
| Density | 1.13 g/cc |
| Tensile Strength Ultimate | 35.0 MPa |
| Elongation At Break | 15 % |
| Modulus Of Elasticity | 1.60 GPa |
| Flexural Strength | 50.0 MPa |
| Flexural Modulus | 1.60 GPa |
| Hardness Shore D | 80 |
| Izod Impact Notched | 0.250 J/cm |
| Glass Transition Temp | 45.0 °C |
| Water Absorption | 0.30 % |
As an accredited DSM Somos 7120 Epoxy Photopolymer, Green Parts factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | |
| Shipping | |
| Storage |
Competitive DSM Somos 7120 Epoxy Photopolymer, Green Parts prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618136850665
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
DSM Somos 7120 Epoxy Photopolymer is an unfilled stereolithography resin that cures into opaque green parts under 355 nm solid-state laser irradiation. The liquid is formulated as a low-viscosity epoxy system; representative values include a density of 1.13 g/cm³ at 25 °C and a viscosity of approximately 250 cP at 30 °C. This viscosity range supports rapid recoating in vat photopolymerization platforms operating at 100 µm and 150 µm layer thicknesses. Because curing proceeds through a cationic mechanism, polymerization continues after laser exposure through dark cure. As-built green parts therefore exhibit time-dependent modulus and residual solvent sensitivity until a defined post-cure interval has been completed. The green state is characterized by low stiffness, susceptibility to indentation, and sensitivity to prolonged immersion in aggressive cleaning solvents. In typical handling, parts are washed with isopropanol or tripropylene glycol monomethyl ether using automated centrifuge or 40 kHz ultrasonic stations for 5–10 min, then dried with filtered compressed air before thermal post-cure.
On production stereolithography machines fitted with a recoater blade gap of 100 µm, the material’s low viscosity reduces recoating forces but requires close control of vat temperature. Below 20 °C, viscosity rises sufficiently to induce blade chatter and layer-thickness variation. Above 30 °C, thermal thinning can destabilize the meniscus and produce nonuniform wetting across the build platform. A consistent build chamber environment of 20–30 °C and 30–50 % relative humidity is therefore recommended for dimensional reproducibility. At relative humidity above 60 %, absorbed water can delay green-strength development and promote interlayer delamination during post-cure. Extended open-vat exposure in such conditions may require conditioned air purge or desiccant dryers on the resin chamber. The resin should be stored in sealed, opaque containers; repeated freeze–thaw cycling is not recommended because condensation can accelerate hydrolysis of residual epoxide groups at the liquid surface.
Green-state stability is governed primarily by residual photoacid concentration, solvent retention, and moisture uptake. The epoxy network is mildly hygroscopic. Water absorption after 24 h immersion is 0.4–0.6 % according to ASTM D570-98, but continuous exposure in a high-humidity vat can create a surface-tack condition that is not fully reversed by thermal post-cure. In practice, parts built at relative humidity above 60 % have shown delayed hardness development after the same 60–80 °C post-cure schedule. The effect is more pronounced in thin sections below 1.0 mm, where water ingress occurs through both surfaces and reduces the glass-transition contribution to green modulus. For critical parts, gravimetric monitoring of green samples before and after post-cure provides a useful release criterion: a mass loss of less than 0.2 wt% during post-cure is generally associated with low residual solvent and low absorbed water, although published data for this specific configuration are limited.
Resin temperature also interacts with dark-cure kinetics. At higher temperatures, cationic dark cure proceeds faster, but the same condition lowers viscosity and may increase the tendency of high-aspect-ratio supports to shift during recoating. At lower temperatures, dark cure slows and the green part remains soft longer, increasing the risk of deformation during support removal. Operators on sandblasting or support-removal stations should delay aggressive support removal until the part has reached a visible surface hardness sufficient to resist fingernail indentation. Thermal post-cure is typically 30–60 min at 60–80 °C, followed by dimensional stabilization at 23 °C and 50 % relative humidity for at least 24 h before metrology. Thin ribs and unsupported spans may require fixture support during post-cure because the material softens before final crosslink density is achieved.
Representative cured properties are summarized in Table 1 for fully post-cured specimens. Flexural modulus spans 1900–2400 MPa and tensile modulus spans 2100–2600 MPa, placing the resin in the intermediate-stiffness range of unfilled epoxy stereolithography materials. Notched Izod impact is 0.25–0.35 J/cm according to ASTM D256-10, which is lower than many engineering ABS-like photopolymers. Snap-fit and living-hinge features are therefore not recommended; if load-bearing clips are required, the design should incorporate root radii larger than 1.0 mm and avoid sharp re-entrant corners. Heat deflection temperatures of 55–65 °C at 0.46 MPa and 50–55 °C at 1.82 MPa restrict direct use in underhood automotive zones, steam autoclave cycles, and continuous service above 45 °C under load.
| Property | Typical value | Test method |
|---|---|---|
| Liquid density at 25 °C | 1.13 g/cm³ | ASTM D4052-22 |
| Viscosity at 30 °C | 250 cP | ASTM D2196-20 |
| Tensile modulus | 2100–2600 MPa | ASTM D638-14 |
| Tensile strength | 40–50 MPa | ASTM D638-14 |
| Elongation at break | 5–10 % | ASTM D638-14 |
| Flexural modulus | 1900–2400 MPa | ASTM D790-17 |
| Flexural strength | 65–75 MPa | ASTM D790-17 |
| Notched Izod impact | 0.25–0.35 J/cm | ASTM D256-10 |
| Heat deflection temperature at 0.46 MPa | 55–65 °C | ASTM D648-18 |
| Heat deflection temperature at 1.82 MPa | 50–55 °C | ASTM D648-18 |
| Shore D hardness | 84–86 | ASTM D2240-15 |
| Water absorption, 24 h | 0.4–0.6 % | ASTM D570-98 |
Unlike optically clear low-moisture stereolithography resins such as DSM Somos WaterShed XC 11122, Somos 7120 is not specified for transmittance or flow-visualization testing. The opaque green surface provides visual contrast for inspection of fillets, shutouts, and hand-finished regions, but it cannot serve as a transparent window or microfluidic visualization section. Compared with high-temperature filled epoxy resins, Somos 7120 is unfilled and produces lower tool wear during bench-top post-machining. Carbide end mills and silicon carbide sanding media do not encounter abrasive mineral filler. However, the unfilled network also yields lower notched impact than mineral-filled systems. The low liquid viscosity is advantageous for vat drainage and resin recycling, but it requires more frequent resin level checks because the thin meniscus is less forgiving of platform tilt or uneven recoater blade wear.
Amine-based surface hardeners, ammonia-containing cleaning fluids, and high-pH aqueous baths should be avoided. Amines attack the epoxy network and can soften post-cured surfaces, while strongly alkaline cleaners can promote surface hydrolysis over repeated cycles. Acidic mold release systems may quench residual cationic species and leave a tacky surface. Before applying RTV silicone tooling to a pattern, a full post-cure of 30–60 min at 60–80 °C should be completed. Insufficient post-cure has been observed to permit migration of low-molecular-weight species into platinum-cure silicone, inhibiting catalyst activity at the pattern interface. This effect is not unique to Somos 7120, but the low post-cure temperature requirement makes it manageable with standard convection or UV post-cure chambers equipped with nominal 365–405 nm broadband sources.
In prototype and tooling applications where an opaque green visual reference is needed for surface-defect detection, the material is typically assigned to concept models, functional prototypes, and master patterns for room-temperature RTV molding. It can be used for investment casting patterns when the burnout schedule reaches the ash threshold of the cured epoxy system, though published burnout residue data for this specific configuration are limited and foundry-specific validation is required. For jigs, fixtures, and inspection gauges that remain below 45 °C under load, the material provides a stable thermoset platform. Prolonged outdoor UV exposure can cause surface oxidation and color shift; parts intended for such exposure require a protective coating or acceptance of cosmetic change. Compliance statements for RoHS 2011/65/EU and REACH 1907/2006 should be confirmed against the specific batch certificate because the formulation contains photoacid generators and epoxide monomers subject to substance-level reporting thresholds.
Process boundaries are consolidated in Table 2. These limits are derived from vat photopolymerization equipment behavior and should be treated as release windows rather than absolute material limits. Builds outside the recommended envelope may still produce dimensionally useful parts, but rejection rates for interlayer delamination, surface tack, and post-cure distortion increase when multiple boundaries are exceeded simultaneously.
| Process variable | Recommended window | Observed effect outside window |
|---|---|---|
| Build chamber relative humidity | 30–50 % RH | Above 60 % RH may delay green strength and cause surface tack; below 30 % RH can increase static charge on recoater surfaces |
| Resin vat temperature | 20–30 °C | Below 20 °C can cause recoater blade chatter; above 30 °C can destabilize meniscus control |
| Post-cure temperature | 60–80 °C for 30–60 min | Below 60 °C requires longer dwell; above 80 °C can distort thin unsupported sections before crosslink completion |
| Layer thickness | 100–150 µm | Above 150 µm may reduce overlap and green strength in low-energy regions of the scan field |
| Green-part cleaning solvent immersion | 5–10 min | Extended immersion can plasticize the green surface and increase post-cure warp |
Dimensional control for 100 mm bar specimens after full post-cure is typically evaluated on coordinate measuring machines following stabilization at 23 °C and 50 % relative humidity. The layerwise build process introduces anisotropic shrinkage, with through-thickness change usually larger than in-plane change. Shrink compensation factors should be calibrated on the specific stereolithography platform and scan strategy rather than copied from other resin systems. Thin walls below 1.0 mm tend to retain less residual stress after post-cure than thick bulk sections, but they also respond more strongly to moisture absorption. For close-tolerance features, the recommended approach is to build a calibration artifact with representative wall thickness, separation plane, and support density before committing to full production geometry.