    HS Code 269194
    Product Name DruckWege TYPE D STANDARD High Precision UV Resins
    Product Type UV photopolymer resin
    Compatible Technologies SLA, DLP, LCD
    Wavelength 405 nm
    Color Transparent
    Viscosity 150-250 mPa·s at 25°C
    Density 1.05-1.15 g/cm³
    Shore Hardness 80-85 Shore D
    Tensile Strength 45-60 MPa
    Elongation At Break 5-10%
    Flexural Strength 70-90 MPa
    Flexural Modulus 2000-2500 MPa
    Shrinkage <0.5%
    Layer Thickness 25-100 µm
    Packaging 500 g, 1000 g
    Shelf Life 12 months

    As an accredited DruckWege TYPE D STANDARD High Precision UV Resins factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing
    Shipping
    Storage
    Free Quote

    Competitive DruckWege TYPE D STANDARD High Precision UV Resins prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    DruckWege TYPE D STANDARD High Precision UV Resin is supplied as a rigid, unfilled acrylate-based photopolymer for masked stereolithography, digital light processing, and laser-galvanometer systems operating in the 385 nm to 405 nm spectral window. The product designation identifies a high-precision variant within the DruckWege resin range; the formulation is intended to retain fine feature definition, reduced long-term moisture drift, and repeatable green-part handling stiffness compared with general-purpose rapid model resins. In production-scale 405 nm LCD printers with measured irradiance between 4.0 mW/cm² and 6.5 mW/cm² at the resin plane, similar high-precision rigid photopolymers have been processed at 50 μm layer thickness with exposure times from 1.8 s to 3.2 s per layer. These process values are class-reference data rather than certified TYPE D STANDARD values; published data for the DruckWege-specific configuration is limited where the supplier has not issued lot-specific certificates.

    Uncured resin should be stored away from UV and blue-light sources at 20 °C to 30 °C and conditioned to 25 °C before use to reduce viscosity drift. For machines operating in humid rooms, resin left in open vats beyond 24 h may require gentle mixing or desiccant conditioning to restore photoinitiator and pigment dispersion. The addition of amine-based additives must be avoided because premature aminolysis of acrylate esters can produce dark-cure instability and surface tack. Operators should confirm that the printer resin tray, build platform coating, and release film are compatible with acrylate-based photopolymers; fluoropolymer films are standard, but silicone-coated release layers can exhibit dewetting with some high-precision acrylate formulations.

    What Is the Photopolymerization Window for TYPE D STANDARD?

    Photopolymerization depth in high-precision acrylate systems follows a logarithmic dependence on incident energy; the critical exposure required to cure a 50 μm slice therefore depends on photoinitiator concentration, pigment loading, and light penetration depth. Acylphosphine oxide photoinitiator packages are common in 405 nm resins because their absorption tail permits through-cure without the severe surface haze associated with shorter-wavelength UV initiators. Cure-depth studies for similar rigid acrylate formulations show that an increase in exposure energy by may extend cure depth by 40 μm to 80 μm, depending on inhibitor concentration and absorptive additives. The exposure window narrows at layer heights below 25 μm because light scattering and sidewall overgrowth become more sensitive to local irradiance nonuniformity.

    Oxygen inhibition at the resin-vat interface is a critical boundary condition. Dissolved oxygen in the uncured resin consumes photo-generated radicals and can reduce surface conversion, producing weak first-layer adhesion. For comparable high-precision resins, first-layer exposure is often raised by to relative to normal layer exposure, and bottom-layer counts of 4 to 8 are retained to stabilize the build. Diagnostic exposure arrays from 20 s to 80 s per first layer are used on production equipment to identify the minimum cohesive-failure threshold for a given release film. Lot-to-lot variation in optical density or pigment dispersion can shift optimal exposure by 10% to 15%; in-line exposure calibration is therefore recommended when changing lot, machine, or film type.

    Machine calibration should be based on an exposure test rather than a fixed time. A stair-step or hatch-overgrowth diagnostic printed at 50 μm layer height can reveal under-cure as interlayer delamination and over-cure as edge growth beyond the nominal geometry. For features requiring dimensional tolerance tighter than ±0.1 mm, build orientations that place critical surfaces parallel to the build plane are preferred because layer stair-stepping dominates surface error. No product-specific dimensional-capability data for DruckWege TYPE D STANDARD at 25 μm layer height have been published in accessible technical literature; capability must be validated on the actual printer and post-cure system.

    Dimensional Stability, Shrinkage, and Part Accuracy

    High-precision rigid photopolymers commonly exhibit linear polymerization shrinkage from 0.3% to 1.0% when evaluated by ASTM D6289-08. Most shrinkage occurs during photopolymerization rather than during thermal post-cure. In materials of the TYPE D STANDARD class, shrinkage control is achieved through high-molecular-weight oligomers, reduced monomer dilution, and controlled crosslink density; however, published data for the specific DruckWege formulation are limited. Shrinkage compensation in the build software must be validated separately from resin viscosity and tensile data, because compensation factors shift with part wall thickness, infill pattern, and local light dose.

    Moisture uptake in comparable rigid high-precision resins measured according to ASTM D570-22 generally falls between 1.0% and 2.5% after 24 h immersion. This uptake is partially reversible in thin sections but can temporarily lower glass transition temperature by 3 °C to 8 °C and produce dimensional swelling. For metrology fixtures, master patterns, or fit-check parts exposed to ambient humidity above 60% RH, dimensional measurement should be performed after conditioning at 23 °C and 50% RH. The use of ISO 2768-1 tolerance classes is recommended only for post-cured parts, because secondary cure can alter constrained dimensions by 0.05% to 0.2%.

    After build completion, green parts are drained under amber or yellow lighting to prevent uncontrolled photopolymerization. Cleaning in 99% isopropyl alcohol or tripropylene glycol monomethyl ether is performed in an ultrasonic bath at 25 °C to 30 °C for 3 min to 6 min. Prolonged solvent exposure above 10 min can craze thin walls and extract uncured low-molecular-weight acrylates, reducing the post-cure glass transition by 5 °C to 10 °C in similar rigid photopolymer systems. After washing, parts should be blown dry with filtered compressed air at 0.5 bar to 1.5 bar and allowed to reach solvent-free mass before final cure.

    Post-cure is typically performed at 405 nm in a chamber delivering 10 mW/cm² to 40 mW/cm² for 15 min to 60 min. A thermal post-cure at 40 °C to 60 °C may accelerate conversion but increases thermal warping risk in asymmetric sections. Chamber temperature should be held within ±5 °C of the defined setpoint to avoid differential expansion between thick and thin regions. Degree of conversion may be monitored by FTIR methacrylate peak decay at 810 cm⁻¹, rather than by fixed time alone. Incompletely post-cured parts may exhibit surface tack, reduced solvent resistance, and lower HDT values when tested by ASTM D648-18.

    When TYPE D STANDARD Replaces General-Purpose Model Resin in Prototyping Lines

    Compared with general-purpose rapid photopolymers, high-precision formulations usually exhibit lower uncured viscosity, higher green modulus, and lower critical-exposure variation across the build area. A shift from a general-purpose model resin to DruckWege TYPE D STANDARD changes support removal force, post-cure expansion, and exposed-edge overgrowth. General-purpose resins often tolerate layer-time variations of ±20%; high-precision resins may narrow that latitude to ±10% or less because the same optical absorbance that sharpens edges also reduces overexposure tolerance. Production-scale failures observed with similar high-precision resins include vat-wall crystallization when stored below 15 °C, build-plate delamination from first-layer oxygen inhibition, and surface pitting caused by particulate contamination from reused cleaning solvent.

    Support removal from TYPE D STANDARD class parts should be performed before post-cure when the resin is still in a lower-modulus green state. Cutting or snapping supports after full post-cure can introduce microcracks at support tips, particularly in stiff high-resolution materials with tensile modulus above 1.8 GPa. In production lines, support-contact marks are reduced by using spherical contact tips and depths below 0.15 mm. For parts with fine negative features, compressed-air or low-pressure solvent flushing after support removal is required to prevent uncured resin accumulation in blind holes and channels.

    Comparative performance envelope for rigid photopolymer classes; values are published ranges for industrial resin classes and are not DruckWege-specific lot data.
    ParameterHigh-precision classGeneral-purpose model resinEngineering rigid resinTest method
    Viscosity at 25 °C150 mPa·s to 650 mPa·s200 mPa·s to 1200 mPa·s500 mPa·s to 3000 mPa·sISO 2884-1
    Tensile strength40 MPa to 65 MPa30 MPa to 50 MPa70 MPa to 90 MPaASTM D638-14
    Tensile modulus1.8 GPa to 2.8 GPa1.0 GPa to 2.0 GPa2.5 GPa to 4.0 GPaASTM D638-14
    Flexural strength60 MPa to 100 MPa50 MPa to 80 MPa100 MPa to 150 MPaISO 178:2019
    Heat deflection temperature at 0.45 MPa50 °C to 75 °C45 °C to 60 °C80 °C to 120 °CASTM D648-18
    Linear shrinkage0.3% to 1.0%0.8% to 1.5%0.2% to 0.8%ASTM D6289-08

    Differences from flexible, castable, and engineering resins are equally process-relevant. Flexible resins exhibit lower Shore D hardness and higher elongation but cannot maintain fine negative features under load. Castable resins leave low ash residue after burnout; DruckWege TYPE D STANDARD is not intended for investment casting because its acrylate backbone may leave carbonaceous residue that exceeds typical foundry ash limits. Engineering rigid resins provide higher heat deflection temperature, often above 80 °C, but their higher viscosity and tighter process latitude may be unnecessary for high-precision model and fixture production.

    Compliance, Cleanup, and Waste-Handling Requirements

    Industrial use requires verification against the applicable regulatory framework. Acrylate monomers and photoinitiators in UV resins are subject to REACH 1907/2006 registration obligations and may require workplace exposure assessment under national chemical safety requirements. The cured article should be screened for heavy metals under RoHS 2011/65/EU when electrical or electronic equipment applications are intended. Mechanical property verification is typically performed according to ASTM D638-14 and ISO 527-2:2012 for tensile properties, ISO 178:2019 for flexural properties, ISO 868:2003 or ASTM D2240-15 for Shore hardness, ASTM D648-18 or ISO 75-2:2013 for heat deflection temperature, and ISO 175:2010 for chemical resistance.

    Compliance verification matrix for DruckWege TYPE D STANDARD production use.
    Standard or regulationScopeRelevant evaluation
    REACH 1907/2006Registration and safe use of monomers and photoinitiatorsSupply-chain safety data sheet review; workplace exposure limit assessment
    RoHS 2011/65/EURestriction of hazardous substances in homogeneous materialsX-ray fluorescence screening of cured parts for lead, mercury, cadmium, hexavalent chromium, PBB, and PBDE
    ASTM D638-14Tensile properties of plasticsPost-cured specimen tensile strength, modulus, elongation
    ISO 527-2:2012Tensile test conditions for plasticsAlternative tensile verification with international equivalence
    ISO 868:2003 / ASTM D2240-15Durometer hardnessShore D hardness after complete post-cure
    ASTM D648-18 / ISO 75-2:2013Deflection temperatureHeat deflection temperature at 0.45 MPa
    ASTM D6289-08Shrinkage during cureDimensional change from liquid to cured state
    ISO 175:2010Chemical resistanceMass and dimensional change after solvent immersion

    Uncured resin must not be discharged to water or placed in unsealed municipal waste. Residual liquid waste is polymerized under UV lamps or mixed with a controlled UV-cure waste solidification agent before disposal according to local chemical-waste regulations. Cleaning solvents containing dissolved acrylate residues should be segregated and handled as hazardous solvent waste. During ultrasonic cleaning with isopropyl alcohol, explosion-proof ventilation is required where airborne isopropanol concentrations approach 2% by volume, the lower flammability limit. Nitrile gloves and chemical-splash eye protection are required for handling uncured resin; skin contact with uncured acrylate may cause sensitization with repeated exposure. The operational boundaries for DruckWege TYPE D STANDARD therefore include controlled storage temperature, exposure calibration, solvent compatibility, post-cure dose verification, and full compliance review of the specific lot certificate and safety data sheet before transfer to production.