| HS Code | 637812 |
| Productname | DruckWege TYPE D HIGH TEMP Functional UV Resin For High Temperatures |
| Brand | DruckWege |
| Resintype | UV-curable functional resin |
| Compatibility | LCD, DLP, and SLA 3D printers |
| Curingwavelength | 405 nm |
| Temperatureresistance | up to 200 °C |
| Hardnessshored | 85-88 |
| Tensilestrength | 65 MPa |
| Flexuralstrength | 100-120 MPa |
| Elongationatbreak | 3-5% |
| Shrinkage | <0.5% |
| Viscosity | 200-400 mPa·s at 25 °C |
| Density | 1.10 g/cm³ |
| Color | Amber / translucent |
| Odor | Low odor |
| Shelflife | 12 months |
| Netweight | 1 kg |
As an accredited DruckWege TYPE D HIGH TEMP Functional UV Resin For High Temperatures factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | |
| Shipping | |
| Storage |
Competitive DruckWege TYPE D HIGH TEMP Functional UV Resin For High Temperatures prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618136850665
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
For high-temperature UV-curable workflows requiring functional parts after continuous exposure above 120 °C, DruckWege TYPE D HIGH TEMP Functional UV Resin For High Temperatures is supplied as a one-part, solvent-free liquid with a Brookfield viscosity of 430–520 mPa·s at 25 °C when measured under ASTM D2196-20. Cured density is 1.12 g/cm³ per ASTM D792-20. The resin uses a high-functionality acrylate backbone to achieve a crosslink density that differs from standard urethane acrylate prototyping resins; the unpigmented liquid transmits sufficient UV-A energy for 50–100 µm layer thickness when processed on 365 nm mercury arc or 385 nm LED systems. Storage is specified between 15 °C and 30 °C in opaque containers. Exposure to ambient light above 350 lux for more than 8 h raises viscosity by 5–8 % and advances the photoinitiator system sufficiently to reduce working curve penetration depth by 10–15 %. Before use, the resin must be brought to 25 °C, and bulk containers must not be recirculated through unshielded acrylic tubing because stray UV from inspection lamps can form gel nuclei.
Depth of cure is governed by photoinitiator absorbance and unfilled resin transparency at the exposure wavelength. At 385 nm, a collimated LED source with 8 W/cm² irradiance and a dose of 4.5 J/cm² produces a single-layer cure depth of 180 µm; at 365 nm, the same dose yields 120 µm because the high-temperature backbone absorbs more strongly in shorter UV-A wavelengths. Layer thickness outside 50–100 µm at 385 nm is not recommended without dose compensation; underpolymerized interlayers lower glass transition temperature by 10–15 °C and create a brittle fracture path under flexural load. On a 4K DLP engine with a 10.1 inch build area and 12.5 mW/cm² measured at the vat surface, exposure time per 50 µm layer is 4.0–5.5 s with vat temperature at 30 °C. Below 25 °C, viscosity increases to 700 mPa·s and recoating defects appear as ripples exceeding 15 µm; above 35 °C, dark-polymerization in the vat increases gel particles larger than 200 µm after 12 h of continuous printing. The working curve shows critical energy of 85 mJ/cm² and penetration depth of 0.16 mm at 385 nm, placing TYPE D between low-viscosity prototyping resins and heavily filled ceramic UV resins in process latitude. Oxygen inhibition at the free surface remains significant; without inert gas blanketing, a tacky layer of 2–4 µm remains after exposure and requires solvent wiping or additional post-cure.
Continuous printing imposes a different stability boundary than intermittent prototyping. In a recirculating vat with a fluoropolymer release film, a reservoir temperature of 28 °C maintains viscosity between 460 mPa·s and 510 mPa·s for 72 h; after this period, viscosity increases by 8–12 % and the release film accumulates gel particles that increase peel force by 25–35 %. Batch-to-batch viscosity variation for TYPE D is specified as ±35 mPa·s at 25 °C. Recirculation pumps must be positive-displacement with low-shear rotors; centrifugal pumps with throttled discharge create shear rates above 1000 s⁻¹ and can initiate localized thermal crosslinking in the pump head. Vat filtration through 50 µm polypropylene mesh is recommended after each 24 h of continuous operation. The resin has a natural settling tendency of less than 0.1 % by volume over 14 days, but color separation at the meniscus can occur under high ambient humidity above 60 % RH; pre-drying of the build chamber air to 40 % RH or lower prevents moisture uptake that would reduce depth of cure by 6–9 %. Open-vat systems in humidity above 60 % RH must be assessed hourly because the uncured resin absorbs water at the surface and forms an incompletely cured skin.
After a post-cure ramp of 0.5 °C/min from 25 °C to 160 °C and a 2 h hold, tensile specimens tested according to ASTM D638-14 Type IV give a tensile strength of 62 MPa, a tensile modulus of 3.1 GPa, and an elongation at break of 3.8 %. Flexural strength measured according to ASTM D790-17 is 105 MPa with a flexural modulus of 2.9 GPa. Notched Izod impact under ASTM D256-10 is 16 J/m, indicating a low-ductility network unsuitable for impact-dominated snap-fit features. Heat deflection temperature determined by ASTM D648-18 Method B at 0.455 MPa is 165 °C; at 1.82 MPa it is 128 °C. DMA under ASTM E1640-18 places the storage modulus onset at 174 °C and the loss modulus peak at 181 °C. These values are representative of the 2 h post-cure; reducing post-cure to 1 h lowers HDT at 0.455 MPa by 12 °C and flexural strength by 8 MPa, creating a process-sensitive boundary for parts entering high-temperature service.
| Property | Test method | Typical value |
|---|---|---|
| Liquid viscosity at 25 °C | ASTM D2196-20 | 430–520 mPa·s |
| Cured density | ASTM D792-20 | 1.12 g/cm³ |
| Hardness, Shore D | ASTM D2240-15 | 88 |
| Tensile strength | ASTM D638-14 Type IV | 62 MPa |
| Tensile modulus | ASTM D638-14 | 3.1 GPa |
| Elongation at break | ASTM D638-14 | 3.8 % |
| Flexural strength | ASTM D790-17 | 105 MPa |
| Flexural modulus | ASTM D790-17 | 2.9 GPa |
| Notched Izod impact | ASTM D256-10 | 16 J/m |
| HDT at 0.455 MPa | ASTM D648-18 Method B | 165 °C |
| HDT at 1.82 MPa | ASTM D648-18 Method B | 128 °C |
| Glass transition, DMA E' onset | ASTM E1640-18 | 174 °C |
The highest risk in thick-section high-temperature UV parts is anisotropic shrinkage during post-cure. On 6.4 mm thick blocks, a ramp rate of 1.0 °C/min to 160 °C produces in-plane linear shrinkage of 0.32 %; increasing the ramp to 2.5 °C/min raises in-plane shrinkage to 0.58 % and generates corner-to-corner warpage of 0.41 mm over a 100 mm length. The process window is therefore ≤ ±5 °C in soak uniformity across the oven. Multi-station ovens with edge-mounted resistive elements and no active air recirculation typically exhibit spatial spread of 8–12 °C, which is not acceptable for sections thicker than 4 mm; forced-convection or vacuum ovens with ±2 °C uniformity are required. Shrinkage anisotropy is largest when exposure is performed at 23 °C and the part is ramped without an intermediate 60 °C hold. A 60 °C hold of 30 min before ramp completion reduces z-axis shrinkage variation from 0.15 % to 0.07 % in 10 mm tall specimens. Shrinkage values are measured by optical comparator against a calibrated Invar reference block, not by volumetric displacement, because volumetric methods underestimate anisotropy in high-crosslink-density resins.
Oxidative surface degradation above 140 °C in air produces a 5–10 µm discolored skin with measurable loss in flexural ductility; nitrogen purge at 0.5 L/min per 100 L chamber volume prevents this effect. TYPE D should not be post-cured above 180 °C in air because ester cleavage and color shift become rapid. Thermal expansion in the cured state measured by thermomechanical analysis under ISO 11359-2:2021 gives a coefficient of linear thermal expansion of 68 ppm/K below the glass transition and 148 ppm/K above it; this change must be accommodated in metal-backed tool inserts to avoid delamination at the interface during repeated thermal cycles.
When exposed to hot polar solvents, TYPE D exhibits narrower chemical boundaries than thermal limits alone would suggest. After full post-cure, immersion in 50 % ethylene glycol/water at 90 °C for 168 h produces a mass increase of 1.4 % and retention of flexural strength above 90 %. Boiling water immersion for 2 h produces a 2.5 % mass increase and a 15 °C depression in wet HDT; drying at 80 °C for 24 h restores most of the original value. Strong alkaline media above pH 12 at 60 °C cause surface etching from ester hydrolysis, and hot polar aprotic solvents such as N-methyl-2-pyrrolidone above 50 °C induce swelling beyond 8 % mass change within 24 h. The product is not recommended for continuous immersion in aggressive organic acids above pH 2 at 70 °C. In fuel vapor exposure, a 72 h exposure to toluene vapor at 23 °C produces a reversible mass increase of 3.1 % and no cracking; methyl ethyl ketone produces visible surface softening at 23 °C within 1 h and should be avoided in cleaning operations after cure. Avoid combination with amine-based additives in uncured resin, because amines accelerate radical decomposition and can cause exothermic gelation in bulk containers.
Measured at 1 MHz, fully post-cured TYPE D HIGH TEMP exhibits a dielectric constant of 3.4 and a dissipation factor of 0.024 under ASTM D150-18. Dielectric strength on 1.0 mm plaques is 18 kV/mm under ASTM D149-20; this value drops to 12 kV/mm after 168 h of aging at 150 °C in air. Volume resistivity after 48 h at 23 °C and 50 % RH is 2.1 × 10¹⁴ Ω·cm according to ASTM D257-14. For electronic encapsulation, the resin is not intended to replace silicone or anhydride-cured epoxy systems in high-voltage isolation because its high-temperature post-cure can induce stress concentration around copper traces; creepage and clearance distances must be maintained per IEC 60664-1. Thermal aging under voltage is not characterized in publicly available data for this specific configuration, so insulation coordination above 200 V requires board-level partial discharge testing.
In thermoforming tools for polycarbonate sheet at 150 °C surface temperature and 0.6 MPa forming pressure, TYPE D has been used for fewer than 30 cycles. The tool must be backed with 6 mm aluminum plate to prevent flexural creep; direct printed shells without support show dimensional drift of 0.2 mm over a 200 mm span after 10 cycles. Soldering pallets exposed to 260 °C wave solder contacts require local shielding and are not within the continuous-use envelope; published data for this specific configuration is limited.
Conventional UV acrylate resins for rapid prototyping typically exhibit HDT below 85 °C at 0.455 MPa and glass transition below 95 °C. TYPE D HIGH TEMP shifts HDT to 165 °C and DMA glass transition to 174 °C at the cost of reduced elongation and impact toughness. Compared with silica-filled high-temperature epoxy tooling boards, TYPE D has a lower mixed-component viscosity than paste systems, enabling recoating and self-leveling in stereolithography; however, the epoxy boards retain better resistance to hot polar solvents and offer higher fracture toughness. The comparative table lists values from the same test methods for TYPE D and a general-purpose UV acrylate control. Thermal-cure epoxy data are not included because cross-polymer comparisons require different cure schedules and specimen conditioning; published data for this specific configuration is limited when evaluated under ASTM D638-14 without post-cure normalization.
| Property | Type D HIGH TEMP | General-purpose UV acrylate |
|---|---|---|
| HDT at 0.455 MPa | 165 °C | 72–85 °C |
| Tg by DMA | 174 °C | 88–96 °C |
| Tensile strength | 62 MPa | 45–55 MPa |
| Elongation at break | 3.8 % | 8–15 % |
| Notched Izod impact | 16 J/m | 25–40 J/m |
| Viscosity at 25 °C | 430–520 mPa·s | 250–400 mPa·s |
For injection molding insert applications with melt temperatures below 230 °C, clamp forces not exceeding 80 metric tons, and shot counts under 200 cycles, TYPE D HIGH TEMP has been applied as a printed cavity insert in short-run molding of polypropylene and glass-filled polypropylene. The insert must be post-cured to 160 °C with a controlled ramp and supported by a metal backing frame because the notched Izod value of 16 J/m does not tolerate ejection impacts or high shear at gate locations. Published shot-count data for this specific configuration is limited beyond 500 cycles; direct extrapolation to production-scale tooling is not supported. In electronics encapsulation and soldering pallets, exposure peaks up to 180 °C for 10 min are acceptable for post-cured parts, but continuous service above 150 °C in air should be validated by ASTM D648-18 aging studies because oxidative surface degradation accelerates above 140 °C. The product is unsuitable for applications requiring > 10 % elongation at break, food-contact compliance under FDA 21 CFR without a migration study, or direct steam sterilization at 134 °C because water absorption and ester hydrolysis combine to reduce HDT by more than 20 °C after 50 cycles.