| HS Code | 504186 |
| Density | 0.922 g/cm3 |
| Melt Index | 1.5 g/10 min at 190°C/2.16 kg |
| Melting Point | 110°C |
| Vicat Softening Point | 88°C |
| Tensile Strength At Break Cured | 20.7 MPa |
| Tensile Strength At Yield Cured | 10.3 MPa |
| Elongation At Break Cured | 500% |
| Flexural Modulus | 0.241 GPa |
| Hardness Shore D | 50 |
| Volume Resistivity | 1e16 ohm·cm |
| Dielectric Constant | 2.3 |
| Dissipation Factor | 0.0005 |
| Dielectric Strength | 20 kV/mm |
| Water Absorption | 0.100% |
| Brittleness Temperature | -70°C |
| Silane Graft Level | 1.0% |
| Crosslinking Method | Moisture cure |
| Thermal Stability | 260°C |
As an accredited Dow SI-LINK XLPE DFDA-6451 NT factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Dow SI-LINK XLPE DFDA-6451 NT is packaged in sealed 25 kg moisture-barrier bags, palletized for shipment and storage. |
| Container Loading (20′ FCL) | Load Dow SI-LINK XLPE DFDA-6451 NT into a 20-foot FCL container under dry, clean conditions with secure stowage. |
| Shipping | Dow SI-LINK XLPE DFDA-6451 NT is normally not regulated as dangerous goods for transport (DOT/IMDG/IATA). Ship in original sealed, moisture-barrier packaging in clean, dry containers at ambient temperature. Protect from heat, sunlight, and contamination; secure pallets, use appropriate handling equipment, and follow SDS/local regulations. |
| Storage | Store Dow SI-LINK XLPE DFDA-6451 NT in original, sealed containers in a cool, dry, well-ventilated area away from direct sunlight, heat, ignition sources, and moisture. Keep containers closed when not in use and protect them from physical damage. Because the product is moisture-curable, exclude humidity and water; use first-in, first-out rotation and avoid prolonged outdoor storage. |
| Shelf Life | Typically 6 months from manufacture when stored unopened in original packaging in a cool, dry place at recommended temperatures. |
When a 0.6/1 kV single-core installation cable is manufactured with moisture-cured silane XLPE insulation, the extrusion line is typically built around a 60 mm single-screw extruder with a 30:1 L/D ratio, a compression ratio of 2.5:1, and a crosshead die sized for conductor cross-sections from 1.5 mm² to 16 mm². DFDA-6451 NT is fed at 100 parts by weight; no separate catalyst masterbatch is metered because the compound is supplied with the silane-graft and catalyst package incorporated. Where the cable specification requires coloured insulation for circuit identification, a silane-curable colour masterbatch is added at 1.0–2.0 wt%, not as a universal concentrate based on incompatible LDPE carriers. Barrel zone settings are maintained at 150 °C, 160 °C, 170 °C, 175 °C, 180 °C, and 180 °C from hopper to die, with melt temperature kept below 190 °C. Exceeding 200 °C initiates premature silanol condensation in the screw channel and produces die deposit, surface pinholes, and high hot set values. The extrudate is cooled and immediately wound; crosslinking is then completed in a moisture-curing sauna at 85 °C and 90 % relative humidity for 6–24 h, depending on insulation wall thickness and conductor cross-section. Compliance for this product class is verified through EN 50525-3-41 for 450/750 V XLPE-insulated flexible single-core cables, IEC 60332-1-2 for single-cable flame propagation, and IEC 60811-501 for hot set testing under 0.2 MPa at 200 °C; the required hot set elongation is ≤175 % and permanent set after unloading is ≤15 %. Terminal products include single-core XLPE building installation wires in green/yellow, blue, brown, black, and grey, with conductor operating temperature rated at 90 °C and short-circuit temperature of 250 °C. The main production failure observed on line is centre-pipe moisture ingress into the package after exposure to ambient humidity above 60 % RH; sealed aluminium-lined bags and dry-air purged dosing hoppers are used to prevent pre-curing granules that increase melt pressure and reduce output.
In PV system wiring, EN 50618:2014 and IEC 62930:2017 impose long-term wet-thermal ageing at 85 °C and 85 % relative humidity for at least 1,000 h, followed by insulation resistance and tensile retention verification. DFDA-6451 NT is run as the insulation layer in a single-core construction with tinned copper conductors from 1.5 mm² to 35 mm²; for outdoor service the natural compound is let down at 96–97 wt% with a carbon black/HALS masterbatch at 3–4 wt% to provide UV opacity and limit photo-oxidative chain scission. When the cable is also required to meet IEC 60332-1-2 single-flame propagation, a halogen-free flame-retardant masterbatch can be incorporated at 10–18 wt%, but the resulting increase in melt viscosity reduces line speed and requires a 60 mm or 90 mm extruder with L/D 30:1 and a high-wear barrel. The insulation is applied at wall thickness 0.8–1.2 mm depending on conductor size and voltage class; a low-pressure crosshead die is operated at 100–180 bar melt pressure, and the conductor is preheated to 80–120 °C to control insulation eccentricity below 0.05 mm. After extrusion, the cable is cured in a wet sauna at 85 °C and 90 % RH for 12–24 h; degree of crosslinking is checked by hot set according to IEC 60811-501, with elongation ≤175 % at 200 °C under 0.2 MPa. Terminal types include EN 50618 class H1Z2Z2-K and IEC 62930 PV1-F single-core solar cables rated 1.5 kV d.c. and UL 4703 listed PV wire rated 2,000 V. The primary failure mode is interfacial adhesion loss between insulation and tinned copper conductor after prolonged damp heat; therefore manufacturers apply an adhesion promoter or a thin co-extruded semiconductive adhesion layer. Data for DFDA-6451 NT in heavily filled flame-retardant PV grades is limited; formulation validation under full UL 4703 thermal ageing is required before high-volume production.
On production lines, moisture-cured PV insulation failure is most frequently traced to incomplete cure at the conductor interface rather than bulk under-crosslinking, because the tinned copper surface retains moisture and creates a local condensation sink. Monitoring cure degree by hot set on the insulation slab is insufficient; manufacturers therefore strip the conductor and run tear-adhesion checks after 85 °C/85 % RH ageing. The stabilizer package of DFDA-6451 NT is not a substitute for a UV-protective sheath compound; where dual-layer constructions are used, the insulation is not exposed directly to UV, and the sheath compound is selected independently under EN 50618 weathering requirements.
| Application class | Primary standard | Critical test method | Threshold / condition | Typical additive ratio |
|---|---|---|---|---|
| Building installation wire | EN 50525-3-41 | IEC 60811-501 hot set | ≤175 % at 0.2 MPa, 200 °C | 1.0–2.0 wt% colour masterbatch |
| Photovoltaic DC cable | EN 50618:2014, IEC 62930:2017 | 85 °C/85 % RH, 1,000 h damp heat | Tensile retention and insulation resistance | 3–4 wt% carbon black/HALS masterbatch |
| Automotive primary cable | ISO 6722-1:2011, LV 112-1:2010 | Long-term oven ageing | ≥70 % elongation retention after 3,000 h at 150 °C for Class D | 1–2 wt% metal deactivator/heat stabiliser masterbatch |
Thin-wall automotive primary cable extrusion using DFDA-6451 NT normally runs on a 30 mm single-screw extruder with L/D 25:1 and a crosshead designed for conductor cross-sections from 0.35 mm² to 6.0 mm². The compound is processed at melt temperatures of 175–185 °C to avoid premature crosslinking while maintaining sufficient drawdown for insulation thicknesses of 0.20–0.40 mm. The formulation is based on 100 parts by weight of DFDA-6451 NT; for ISO 6722-1:2011 Class C and Class D thermal ageing requirements, a metal deactivator/heat stabiliser masterbatch is added at 1–2 wt% to suppress copper-catalysed oxidative degradation at the conductor boundary. The addition is made at the throat through a gravimetric feeder because weight loss caused by unstable masterbatch dispersion creates localised insulation thinning and dielectric breakdown during 2.5 kV spark testing. Compliance is assessed against ISO 6722-1:2011 for road vehicle cables, LV 112-1:2010 for German OEM requirements, and SAE J1128 for North American low-tension primary cable. Long-term heat ageing is evaluated according to the standard oven method; Class D requires tensile elongation retention above 70 % after 3,000 h at 150 °C. The extruded insulation is moisture-cured at 85 °C and 90 % RH for 12–24 h on reels with perforated flanges. Terminal products include thin-wall single-core automotive primary cables of Class B, C, or D construction, commonly specified in OEM harness drawings as 0.35 mm², 0.5 mm², 0.75 mm², 1.0 mm², 1.5 mm², and 2.5 mm² sections. The main production constraint is the narrow processing window caused by the difference between the 200 °C scorch threshold of the silane compound and the high melt temperature needed for thin-wall drawdown; screw speed and die land length are adjusted to keep melt pressure between 150 and 250 bar.
In UL 758-listed appliance wiring, DFDA-6451 NT is run as a 100 parts by weight insulation compound with 2–4 wt% of a silane-curable colour concentrate for AWM colour code compliance; the concentrate level is adjusted for wall thicknesses from 0.25 mm to 0.76 mm. A silicone process aid is added only when wire surface roughness or high-speed payoff instability is observed on lines running above 300 m/min; the typical dosage is 0.5–1.0 wt%. The extrusion line comprises a 45 mm single-screw extruder with L/D 26:1, a crosshead die with a 35:1 draw ratio, and a water trough with a first-stage temperature of 60 °C followed by 20 °C cooling. Melt temperature is controlled at 170–185 °C; exceeding 190 °C triggers premature crosslinking and increases die drool frequency. After extrusion, the product is crosslinked in a sauna at 85 °C and 90 % RH for 12–24 h. Compliance is verified under UL 1581 with the VW-1 vertical flame test, tensile strength and elongation at 136 °C for 168 h, and cold bend at −40 °C. Under CSA C22.2 No. 210, the insulation is also rated for 105 °C continuous service. Terminal products include AWM hook-up wires rated 125 °C, 600 V, in 30 AWG to 16 AWG sizes, used for internal wiring of household appliances, transformers, and electronic equipment. The main operational boundary is that the compound should not be dried in hot-air hopper driers above 60 °C, because adsorbed moisture in the silane compound can initiate localised microgel formation and cause pinholing during thin-wall extrusion.
The masterbatch carrier must be a silane-curable polyethylene with similar melt viscosity; the use of standard ethylene-vinyl acetate or LDPE colour carriers at the same addition level creates phase separation, reduces surface smoothness, and can shift the hot set performance beyond the UL 1581 limit. Amine-based organic pigments and amine heat stabilisers are excluded from the masterbatch specification because they interfere with the silanol condensation catalyst system. Production experience indicates that batch-to-batch MFR variation outside the supplier control band alters back pressure by 10–15 % and requires screw speed adjustment to keep insulation thickness within the AWM dimensional tolerance.
For industrial control cable insulation converted from 70 °C PVC to 90 °C XLPE in wet processing environments, DFDA-6451 NT permits a reduction in insulation wall thickness while retaining the 300/500 V or 0.6/1 kV rating and increasing continuous conductor temperature from 70 °C to 90 °C. The compound is supplied as a ready-to-run silane XLPE; no catalyst masterbatch letdown is used. Where bundle flame behaviour must meet IEC 60332-3-22 Category A/F, 8–20 wt% halogen-free flame-retardant masterbatch is incorporated, with the lower addition used for shielded paired constructions and the higher addition for unshielded multicore bundles. The masterbatch is metered gravimetrically at the extruder throat; the barrel profile is 140 °C, 155 °C, 165 °C, 175 °C, 180 °C, and 185 °C with a melt filter pack of 100/80/40 mesh to remove crosslinked gel particles larger than 200 µm. A 60 mm single-screw extruder with L/D 30:1 and low-shear barrier screw is used; melt temperature is held at 175–185 °C. The primary insulation layer is applied over tin-plated copper conductors of 0.5 mm² to 2.5 mm²; multi-pass cabling and overall braid or LSZH sheath follow. Moisture curing is conducted after twisting, because the heat of curing can relax twist geometry if performed on single cores before stranding. Crosslinking is verified by hot set per IEC 60811-501: elongation ≤175 % at 200 °C and 0.2 MPa. Terminal product types include EN 50288-7-compliant multi-element instrumentation cables for chemical plants, water treatment lines, and humid motor-control centres. The main limitation is that the silane compound must not be stored above 30 °C in contact with high ambient humidity; opened boxes are used within 8 h or kept under dry nitrogen. Incompatibility with peroxide-cured XLPE regrind is significant because residual peroxide decomposition products generate free radicals that alter silane grafting uniformity.
Competitive Dow SI-LINK XLPE DFDA-6451 NT prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!