| HS Code | 991462 |
| Density | 0.922 g/cm3 |
| Melt Index | 0.50 g/10 min (190°C/2.16 kg) |
| Tensile Strength Cured | 17.2 MPa (2500 psi) |
| Elongation At Break Cured | 500% |
| 100 Modulus Cured | 8.3 MPa (1200 psi) |
| Hardness | Shore D 50 |
| Dielectric Constant | 2.3 at 60 Hz |
| Dissipation Factor | 0.0005 at 60 Hz |
| Volume Resistivity | 1E15 ohm-cm |
| Dielectric Strength | 700 V/mil (27.6 kV/mm) |
| Brittleness Temperature | -70°C |
| Vicat Softening Point | 90°C |
| Water Absorption | <0.1% |
| Moisture Cure Condition | 48 h at 90°C in water |
| Thermal Conductivity | 0.3 W/m-K |
| Coefficient Of Linear Thermal Expansion | 1.5E-4 /°C |
As an accredited Dow SI-LINK XLPE DFDA-5451 NT factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaged in 25 kg polyethylene-lined paper bags, palletized, for handling and storage of Dow SI-LINK XLPE DFDA-5451 NT. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with Dow SI-LINK XLPE DFDA-5451 NT in original sealed packaging, evenly stowed and secured for transport. |
| Shipping | Dow SI-LINK XLPE DFDA-5451 NT is shipped as non-hazardous polyethylene compound pellets. It is not regulated for transport under DOT/IATA/IMDG. Keep containers sealed and dry; protect from moisture, contamination, and excessive heat. No special shipping labels are required. |
| Storage | Store Dow SI-LINK XLPE DFDA-5451 NT in original, sealed containers in a cool, dry, well-ventilated area, away from direct sunlight, heat, ignition sources, and moisture. Keep containers closed when not in use, avoid prolonged high-temperature exposure, and follow the SDS and first-in/first-out stock rotation. |
| Shelf Life | Shelf life is typically 12 months from manufacture when stored unopened in a cool, dry, well-ventilated area per Dow’s datasheet. |
Low-voltage building wire insulation at 600 V class is produced with DFDA-5451 NT as a 95.0:5.0 wt% dry blend of SI-LINK base compound and catalyst masterbatch, metered through a gravimetric hopper blender with ±0.3 wt% tolerance. The downstream extrusion line uses a 60 mm single-screw extruder with L/D 24:1, barrier screw geometry, 2.8:1 compression ratio, and 80/120/80 mesh screen pack. Barrel zone settings progress from 140 °C at the feed throat to 195 °C at the die, while copper conductors from 1.5 mm² to 240 mm² are preheated to 80–120 °C before entering the crosshead. Insulation wall is controlled at 0.76–2.40 mm, with eccentricity monitored by X-ray diameter gauges. The hot extrudate passes through a 70–80 °C water trough and then enters an 80 °C immersion cure bath for 4–8 h; residence time is set by wall thickness and conductor thermal mass. Crosslinking proceeds after extrusion through hydrolysis of alkoxysilane groups to silanols, followed by tin-catalysed condensation to siloxane networks. Cure state is verified by hot creep testing under UL 2556 rather than by post-extrusion electron beam or continuous vulcanization. Compliance is anchored to UL 44 for XHHW-2/RHW-2 thermoset insulation and NFPA 70 Article 310. Physical properties are tested under UL 2556 or ASTM D638, and melt flow rate is characterized by ASTM D1238 at 190 °C, 2.16 kg. Finished terminal products are XHHW-2 and RHW-2 building wires rated 90 °C wet/dry, installed in conduit and raceways for commercial and residential branch circuits. The operating boundary includes a 30 min open-bag exposure limit at ambient relative humidity above 60%, pre-drying of hygroscopic colour concentrates at 70 °C for 3 h, and exclusion of metallic stearate lubricants that can accelerate premature silanol condensation at the die lip and generate surface pitting on 0.76 mm walls.
DFDA-5451 NT is evaluated in thin-wall automotive primary wire where electron-beam crosslinked polyethylene would otherwise be specified, but only for harness sections that remain within the thermal class established by the complete cable construction. The formulation is a 95.0:5.0 wt% dry blend of base compound and SI-LINK catalyst masterbatch. When colour masterbatch is required for harness coding, it is pre-dried to 0.03 wt% moisture or less and added at 1.0–3.0 wt%, while the catalyst masterbatch level is kept at 5.0 wt% to avoid under-cure in walls below 0.40 mm. The extrusion line for thin-wall primary wire typically uses a 50 mm single-screw extruder with L/D 24:1, screw cooling in the feed zone, and vacuum sizing. Conductor sizes from 0.35 mm² to 2.5 mm² are preheated to 90–110 °C, and insulation is applied at 0.20–0.40 mm wall. In production, die build-up from low-molecular-weight silane oligomer migration becomes the primary line-stop defect when melt temperature at the die exceeds 210 °C, because silanol condensation is initiated before the melt leaves the tooling. Curing is carried out after coiling in a steam room at 60 °C and 95% RH for 24 h, or in an 80 °C water bath for 4–6 h, depending on wall thickness and conductor thermal inertia. Compliance standards for the segment are ISO 6722-1:2011 and SAE J1128, with thermal overload, abrasion resistance, and insulation volume resistivity determined on the complete wire. North American automotive primary wire specifications require compliance with SAE J1128 dimensional and performance requirements, while export programs apply ISO 6722-1:2011. Terminal products include SAE J1128 thin-wall primary wire where a moisture-cured XLPE insulation wall is accepted. Published data for full ISO class qualification of this compound in high-temperature engine-compartment locations is limited; cable-level thermal endurance testing under ISO 6722-1:2011 is therefore required before a specific conductor size and harness configuration is released for engine-compartment service.
Appliance internal wiring production with DFDA-5451 NT is configured for 0.45–0.80 mm insulation walls over 0.5–2.5 mm² stranded copper conductors, using a 95.0:5.0 wt% catalyst masterbatch letdown and 1.0–3.0 wt% pre-dried colour concentrate for circuit identification. The process runs on 45 mm or 60 mm single-screw extruders with L/D 20:1–24:1 and medium-compression screws at 2.5:1–3.0:1. Die melt temperature is held between 180 °C and 200 °C, and melt residence time above 200 °C is limited to minimize premature silanol condensation. Post-extrusion curing uses either an 80 °C water bath for 4–6 h or an ambient warehouse cure of 7 days at 50% RH minimum. Accelerated ambient cure at lower humidity produces under-crosslinked walls that fail hot creep tests, so production planning in dry climates requires forced-humidification chambers. The relevant compliance framework is UL 758 Appliance Wiring Material with physical property verification under UL 2556, and IEC 60335-1 for internal wiring in household and similar appliances. Where 105 °C dry ratings are specified, the completed AWM construction is submitted for full component recognition because the insulation alone cannot carry the rating without terminal and connector validation. Terminal products are crosslinked polyethylene AWM constructions used as internal point-to-point wiring in appliances, HVAC equipment, and office machines. Formulation boundaries exclude amine-based flame retardants and metallic stearate dispersion aids, both of which have caused premature catalyst activation and poor surface finish on production extrusion equipment. Only hygroscopic colour concentrates with 0.03 wt% maximum moisture are used, and open hopper residence beyond 20 min in high-humidity plants is avoided.
For direct-burial underground service entrance cable under UL 854 and NFPA 70, DFDA-5451 NT is processed as a moisture-cured primary insulation over soft-annealed copper strands from 2.08 mm² to 107 mm², with the standard 95.0:5.0 wt% blend of base compound and SI-LINK catalyst masterbatch. The process window is tighter than building wire because wet electrical stability is a pass/fail criterion after long-term water immersion. Conductor preheat is set at 100–120 °C, a 60 mm single-screw extruder with L/D 24:1 and 2.8:1 compression ratio is used, and the applied insulation wall ranges from 1.10 mm to 2.40 mm. The hot extrudate is cooled in a 70–80 °C water trough and then immersion-cured at 80 °C for 6–10 h. Cure completeness is checked by gel content according to ASTM D2765 or hot creep under UL 2556, because incomplete crosslinking at the conductor surface layer causes low insulation resistance after wet ageing. UL 854 also imposes sunlight resistance where the cable may be exposed. The natural translucent base compound is combined with a UV-stabilised carbon black concentrate pre-dried to 0.03 wt% maximum moisture, and the addition level is calculated so that the catalyst masterbatch letdown is not shifted by more than 0.2 wt% from the 5.0 wt% target. Terminal products include USE-2 underground service entrance conductors and RHW-2 wet-rated distribution conductors with a 90 °C wet/dry temperature rating. The key production limitation is that the cable must not be subjected to wet dielectric acceptance testing before reaching 90% of final crosslink density. Field failures on accelerated line starts have occurred when cure bath residence was shortened below the minimum wall-thickness-derived setting, producing localized under-cure in the insulation layer adjacent to the conductor.
In industrial control and machine tool wiring, DFDA-5451 NT functions as the inner crosslinked polyethylene insulation of multi-conductor constructions where the outer jacket, not the insulation monolayer, provides oil resistance and flame-rated performance. The base blend is 95.0:5.0 wt% SI-LINK catalyst masterbatch, dry-blended in a guarded hopper system to keep moisture below 0.03 wt%. Extrusion takes place on 50–65 mm single-screw lines with L/D 24:1, barrier screw geometry, and 80/100/80 mesh screen packs. Conductors from 0.82 mm² to 2.08 mm² are preheated to 90–110 °C, and insulation wall thickness is controlled between 0.50 mm and 1.20 mm for a 600 V control circuit rating. After extrusion, the cores are cooled in 70–80 °C water and moisture-cured for 8–12 h at 80 °C or 48 h at 60 °C and 95% RH. This cure step is completed before stranding into multi-conductor assemblies and subsequent jacketing. North American compliance is anchored to NFPA 79, UL 13, and UL 758 AWM, with IEC 60502-1 used for export low-voltage cable construction. Flame propagation, cold bend, and oil resistance are evaluated on the completed cable, not on the DFDA-5451 NT insulation alone. Terminal products include NFPA 79 machine tool wire, control cable cores, and tray cable insulation where crosslinked polyethylene is specified. The main formulation boundary is that flame-retardant fillers are not compounded into the insulation. Attempts to add brominated or phosphate flame retardants have produced premature crosslinking and rough surface finish on production extrusion lines, so flame-rated constructions must achieve their rating through jacket compounds or tape layers.
Competitive Dow SI-LINK XLPE DFDA-5451 NT prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!