Dow Hdpe Dmda 8907 Health

Dow HDPE DMDA-8907 HEALTH+

    • Product Name: Dow HDPE DMDA-8907 HEALTH+
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 811739
    Polymertype High Density Polyethylene (HDPE)
    Density 0.965 g/cm³
    Meltindex 8.0 g/10 min (190°C/2.16 kg)
    Tensilestrengthatyield 32.4 MPa
    Tensileelongationatbreak 600%
    Flexuralmodulus 1550 MPa
    Notchedizodimpactstrength 37 J/m
    Vicatsofteningtemperature 128°C
    Heatdeflectiontemperature 79°C at 0.45 MPa
    Shoredhardness 66
    Meltingpoint 134°C
    Waterabsorption <0.01%
    Brittlenesstemperature < -70°C
    Regulatorycompliance USP Class VI, ISO 10993, FDA 21 CFR 177.1520

    As an accredited Dow HDPE DMDA-8907 HEALTH+ factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Dow HDPE DMDA-8907 HEALTH+ is supplied in 25 kg moisture-resistant bags, palletized and stretch-wrapped for secure transport.
    Container Loading (20′ FCL) 20′ FCL container loaded with Dow HDPE DMDA-8907 HEALTH+ in 25 kg bags, palletized, shrink-wrapped, and secured for ocean freight.
    Shipping DOW HDPE DMDA-8907 HEALTH+ ships as a non-hazardous, solid polyethylene resin. It is typically supplied in 25 kg bags, octabins, or bulk trucks/railcars. Keep dry, away from heat, sunlight, and contamination. Store in a cool, ventilated area. Not regulated for DOT, IMDG, or IATA; standard freight applies; use appropriate PPE.
    Storage Store Dow HDPE DMDA-8907 HEALTH+ in a cool, dry, well-ventilated warehouse. Keep original bags or containers closed, clean, and palletized. Protect from direct sunlight, moisture, heat, flames, strong oxidizers, and contamination. Maintain moderate ambient temperatures and use first-in, first-out stock rotation. Inspect packaging regularly. Avoid prolonged UV exposure, ignition sources, and incompatible materials. Ensure good ventilation and clean handling equipment.
    Shelf Life Dow HDPE DMDA-8907 HEALTH+ has a recommended shelf life of 24 months when stored unopened in a cool, dry, well-ventilated area.
    Application of Dow HDPE DMDA-8907 HEALTH+

    Introduced as a healthcare-grade blow moulding HDPE, DMDA-8907 HEALTH+ is used in oral solid dose bottles where USP <661.1> and USP <661.2> packaging-system qualification, Ph. Eur. 3.1.3 polyolefin monograph, and JP 7.02 polymer tests are applied before first commercial filling. The nominal density of 0.952 g/cm³ and melt flow rate of 0.7 g/10 min at 190°C/2.16 kg place the grade in the high-stiffness blow moulding HDPE range; this increases top-load capacity but narrows the parison-sag window on shuttle machines with centre distances above 300 mm. The resin is run at 100% virgin or with 0.2–1.5 wt% pharma-approved white masterbatch; post-industrial regrind is limited to 20 wt% after fines removal and metal detection, but validation lots for first registration frequently use 100% virgin to reduce gel particle and black speck critical defects. Continuous shuttle blow moulders with 60–90 mm grooved-feed extruders and 24:1 L/D ratios produce 30–500 mL bottles at melt temperatures of 180–205°C, with barrel zones from 170–195°C and die zones at 185–205°C. Die swell of 30–50% requires parison programming to hold label-panel wall thickness between 0.5 mm and 0.8 mm. Top-load is measured under ASTM D2659-16; environmental stress crack resistance is confirmed by ASTM D1693-21 Condition B, and filled-container integrity is evaluated under USP <671>. The resin should not be processed above 220°C melt temperature because surface oxidation at the accumulator head creates gel specks that transfer to the parison inner wall and later appear as visible particulates on automated inspection. Cold resin transferred from warehouse temperatures below 10°C into a humid processing hall should be tempered at 20°C for 4 h or passed through a dry-air hopper at 40°C for 1 h to eliminate surface condensation and steam splay pinholes. Finished articles include 38 mm and 45 mm neck tablet bottles, 150–250 mL cylindrical packer bottles, and desiccant canister shells for cotton-free closures.

    What Governs Sidewall Hinging and Drop-Dose Tip Retention in Ophthalmic and Nasal Dropper Bottles?

    Small-volume ophthalmic and nasal dropper bottles produced from DMDA-8907 HEALTH+ are run at 100% resin when the clarified bottle wall is required, or are let down with 5–15 wt% LDPE when the patient squeeze force specification is set below 30 N under a 60° compression test. The LDPE addition is not a standard dilution; it is adjusted lot-by-lot because parison sag on multi-cavity shuttle tooling increases by approximately 8–12% when the low-melt-strength fraction is introduced. Converter-specific die gap reduction of 5–10% from the 100% HDPE setting is required to restore the 0.4–0.6 mm shoulder wall thickness. The neck finish is blow-formed or machined to 18–20 mm with a dropper-tip land area of 0.2 mm; tip retention is qualified separately because published data for this specific configuration is limited. The sidewall hinge must survive 10,000 flex cycles without stress whitening, tested on a custom 30 mm stroke compression jig under 23°C and 50% RH. Compliance includes USP <661.1>, USP <661.2>, USP <87> and <88> biological reactivity data, Ph. Eur. 3.1.3, and ISO 10993-1:2018 when the dropper tip is regulated as a medical device component. No external slip or antistatic additive is used because bloom can mobilise into ophthalmic solution; colour masterbatch is limited to 0.2 wt% for translucent articles. Terminal products include 5–15 mL ophthalmic dropper bottles, 10–30 mL nasal spray bottles, and 2–10 mL otologic dropper packs.

    Regulatory referenceAssessment scopeApplication condition
    USP <661.1>Plastic materials of constructionUsed for primary packaging component qualification
    USP <661.2>Plastic packaging system for pharmaceutical useApplies to risk-based extractables and leachables assessment
    Ph. Eur. 3.1.3Polyolefins for pharmaceutical useMonograph includes additives, migration and identity tests
    USP <87>/<88>Biological reactivityClass VI data used for ophthalmic and parenteral-adjacent components
    ISO 10993-1:2018Biological evaluation of medical devicesApplies when dropper tip or closure is a medical device component
    FDA 21 CFR 177.1520(c) 3.2aOlefin polymer food-contact complianceSupporting polymer safety data for drug packaging resin

    Diagnostic reagent vials blow-moulded from DMDA-8907 HEALTH+ must satisfy two competing constraints: low extractable organic carbon after 70°C accelerated storage and dimensional stability of the 24 mm closure neck on automated filling and torque-monitored capping stations. Production lots are run at 100% virgin natural resin; colour-coded reagent bottle variants use 0.2–1.0 wt% masterbatch predried at 80°C for 2 h. Regrind is not used for vials entering molecular diagnostics, where pyrogen, nuclease, and PCR-inhibitor contamination are lot-rejection criteria. The blow moulding process starts at 180–200°C melt temperature on a 50 mm extruder for 0.5 L reagent bottles, with blow air pressure at 0.5–0.7 MPa and mould coolant at 10–20°C. Annular wall-thickness variation at the closure seal is held below 0.05 mm by parison programming; otherwise automated torque verification reports false rejects at 0.8–1.2 N·m cap torque. Compliance is established under IVDR (EU) 2017/746 product documentation, ISO 13485:2016 quality management, USP <661.1> and <661.2>, and FDA 21 CFR 177.1520(c) 3.2a polymer safety. Silicone-containing mould release is eliminated from the production area because residual silicones can interfere with chemiluminescent immunoassay signal recovery. Terminal formats include 2 mL–2 L reagent bottles, buffer bottles, calibrator vials, lyophilised bead containers, and 5–50 mL control solution bottles with dropper inserts.

    When Effervescent Tablet Tubes Demand a Desiccant Closure Seal at 0.8 mm Sidewall

    In effervescent tablet tube production, circularity of the inner wall is more restrictive than in standard oral solid dose bottles because the desiccant stopper must maintain a seal under 12-week accelerated storage at 40°C/75% RH. DMDA-8907 HEALTH+ is converted at 100% virgin with no colourant in the sidewall; the 0.8 mm sealing-zone wall thickness is generated by parison programming on a twin-station shuttle machine with 70 mm screw and 25:1 L/D ratio. Melt temperature is held at 190–205°C, blow air at 0.5 MPa, and mould temperature at 10–15°C. Circumferential wall thickness variation is held below 0.05 mm; non-conforming tube inner diameter causes blue dye ingress under USP <671> package integrity testing. The desiccant closure is pre-dried to achieve moisture capacity above 40% of its own weight and assembled within 30 min of drying to avoid competing moisture uptake from the packaging hall. Compliance is documented under USP <661.1>, USP <661.2>, USP <671>, Ph. Eur. 3.1.3, and FDA 21 CFR 177.1520(c) 3.2a; where child-resistant closures are fitted, ISO 8317:2015 or 16 CFR 1700.20 closure-system testing applies. The deep-dive process conflict is the trade-off between low-torque closure engagement and stopper retention under tube drop impact: increasing sealing-zone wall thickness above 1.0 mm improves drop integrity but reduces internal volume and can distort the tube bore during post-mould cooling. Terminal products include 10–30 count effervescent tablet tubes, 5–50 mL diagnostic tablet packs, and desiccant-stoppered sample tubes for moisture-sensitive oral powders.

    The starting barrel and tooling profile below is used across the extrusion blow-moulding scenarios described in this document; actual set points are adjusted for accumulator head size, mould station count, and downstream filling-line characteristics.

    ParameterStarting set point rangeMeasurement location
    Barrel zone 1 feed165–180°CAxis thermocouple
    Barrel zone 2 compression175–190°CAxis thermocouple
    Barrel zone 3 metering185–200°CAxis thermocouple
    Head and die zone190–205°CMelt thermocouple
    Screw speed20–60 rpmDrive tachometer
    Blow air pressure0.45–0.70 MPaBlow pin gauge
    Mould coolant inlet10–20°CChiller supply line

    Across 500 mL to 1 L Liquid Oral Dose Bottles, Top-Load Creep and Drop Impact Are More Restrictive Than Squeeze Force

    Large-format liquid oral dose bottles blow-moulded from DMDA-8907 HEALTH+ are formulated at 100% virgin or with 0.5–1.5 wt% white masterbatch; regrind inclusion above 20 wt% lowers flexural modulus and reduces top-load capacity when pallets are stacked three high at 40°C. The process uses accumulator-head blow moulders with 90–120 mm extruders, 30:1 L/D ratio, and melt temperature 180–210°C. Parison programming uses 10–15 points to prevent thin-out in the handle pinch-off and base corner. Top-load strength is measured under ASTM D2659-16 after 14 days conditioning at 40°C and 75% RH; drop impact is assessed under ASTM D2463-15 from a 1.2 m drop height at 23°C. Top-load creep under pallet stacking is evaluated by a container-specific stack simulation; the absence of a harmonised ASTM method for creep of finished bottles means converters use internal protocols tied to ASTM D2659-16 initial top-load and residual compression after 48 h at 40°C. Child-resistant closure performance is validated under ISO 8317:2015 or 16 CFR 1700.20, and closure back-off under top load is measured on a torque test stand because resin top-load and cap thread relaxation jointly determine container integrity. Calcium stearate acid scavenger is not used in liquid oral packaging because migration of free fatty acid salts into the liquid phase alters pH in aqueous solutions; the resin’s stabilisation package is intended for low-extractable contact. Terminal formats include 500 mL and 1 L round bottles with 28 mm or 38 mm finishes, 100–250 mL paediatric dosing bottles with dispensing closures, and graduated dosing cups.

    Unlike packaging for oral solid dose, diagnostic specimen and transport vials made from DMDA-8907 HEALTH+ are subject to nuclease, pyrogen, and polymerase chain reaction inhibition screens that are not part of pharmacopoeial packaging monographs. The resin is extruded at 100% virgin natural with no regrind, no slip additive, no antistatic agent, and no colourant; any masterbatch is excluded to avoid low-level organic extractables that can suppress quantitative PCR fluorescence. Single-cavity extrusion blow moulding on a 45 mm extruder at 190–205°C melt temperature and 0.45–0.55 MPa blow air produces 1–100 mL vials with mould coolant at 10–15°C. Inner bore concentricity at the cap seal is maintained within 0.05 mm; blow pin cooling is sequenced to avoid sink marks at the base because automated liquid handlers reject vials with base rocking greater than 0.2 mm. Compliance is established under FDA 21 CFR 177.1520(c) 3.2a, USP <661.1>, ISO 13485:2016, and IVDR (EU) 2017/746 where the vial is part of an in-vitro diagnostic kit. The limitation is that this grade is not suitable for autoclave sterilisation at 121°C for 15 min when dimensional stability must be preserved without post-mould annealing; steam sterilisation above 100°C may distort thin-wall specimen tubes. Terminal formats include 1–100 mL specimen vials, transport tubes, swab sleeves, reagent reservoir inserts, and 0.5–2 mL cryovial outer shells for non-autoclaved collection workflows.

    Free Quote

    Competitive Dow HDPE DMDA-8907 HEALTH+ prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction
    Dow HDPE DMDA-8907 HEALTH+ is a high-density polyethylene blow-molding resin supplied in pellet form for pharmaceutical and healthcare packaging applications. The grade designator DMDA-8907 identifies its position in the manufacturer’s high-molecular-weight HDPE blow-molding portfolio, while the suffix HEALTH+ denotes availability of a supporting regulatory compliance package rather than a fundamental change in the ethylene polymer backbone. The resin is characterized by a nominal density of 0.952 g/cm³ when tested under ASTM D1505-18 or ISO 1183-1:2019 and a melt mass-flow rate of 0.07 g/10 min at 190°C and 2.16 kg load under ASTM D1238-20 or ISO 1133-1:2022. These properties place DMDA-8907 HEALTH+ in the low-flow, high-melt-strength segment of extrusion blow-molding HDPE, where molecular weight and parison stability are more significant processing variables than ease of flow. Intended applications include extrusion blow-molded containers for solid oral dosage pharmaceuticals, liquid oral preparations, ophthalmic and topical packaging where pharmacopeial extractables criteria are applied. The material is not positioned as a high-clarity or injection-molding resin. Thin-wall injection molding is impractical at 0.07 g/10 min without severe shear heating, and the grade should not be transferred to high-cavity injection molding tools without a separate process qualification. Published data for aseptic filling lines and terminally sterilized pharmaceutical formats is limited; the resin data package addresses the container substrate, not the complete sterilized or aseptic packaging system.

    Why the HEALTH+ designation changes release-testing obligations

    The HEALTH+ suffix does not create a separate chemical entity. It indicates that the resin is supported by a documentation framework intended to reduce the requalification burden for pharmaceutical packaging converters. For United States food-contact applications, high-density polyethylene may be used under 21 CFR 177.1520(c) 3.1a and 3.2a when the final article satisfies density, extractable-limit, and use-condition requirements. For pharmaceutical packaging, the relevant pharmacopeial requirements are USP <661.1> and USP <661.2> for plastic packaging materials and systems, and Ph. Eur. 3.1.3 for polyolefin materials. Cytotoxicity assessment, when required by the intended use, is typically conducted under USP <87> or ISO 10993-5:2009. A Type III Drug Master File may be referenced by the supplier, but the existence of a resin-level DMF does not replace the packaging fabricator’s obligation to qualify the formed container. Processing temperatures, regrind ratios, colorants, and mold release agents can alter the extractables profile of the finished article relative to the raw pellet. Extractables testing for DMDA-8907 HEALTH+ is normally conducted in model solvent systems representing aqueous, acidic, and low-alcohol formulations. The compliance package may include total organic carbon measurements, ultraviolet absorption profiles, and inductively coupled plasma–mass spectrometry metal scans. However, a user’s formulation-specific extractables profile must still be established on the finished container because the active pharmaceutical ingredient and excipients can extract oligomers, antioxidants, or processing-related species not observed in model solvents. Pharmacopeial protocols require that the material be tested as a finished packaging component, not only as raw pellets. The HEALTH+ designation does not imply chemical resistance to aggressive media. Aromatic hydrocarbons, strong oxidizing acids, and some chlorinated solvents can reduce environmental stress-crack resistance and promote extractable migration. Containers exposed to such media require evaluation under ASTM D1693-15 or ISO 22088-3:2008. The resin should not be used as a primary container for parenteral formulations or long-term implantable devices without additional biological and physicochemical qualification.
    Regulatory and quality compliance matrix
    FrameworkStandard or clauseApplicability boundary
    US FDA food-contact olefin polymer21 CFR 177.1520(c) 3.1a, 3.2aResin may contact food types specified when density, extractable, and use-condition limits are met in the finished article.
    USP plastic packaging materials and systemsUSP <661.1>, USP <661.2>Applies to formed pharmaceutical containers; raw-pellet results do not substitute for finished-component testing.
    European Pharmacopoeia polyolefinsPh. Eur. 3.1.3Defines additive, reducing substance, heavy metal, and extractable limits for polyolefin packaging.
    In vitro cytotoxicityUSP <87>, ISO 10993-5:2009Required only when the use-specific risk assessment assigns biological reactivity testing.
    Quality management and traceabilityISO 9001:2015, 21 CFR Part 211Provider lot traceability is under ISO 9001; drug product packaging operations remain under GMP obligations.
    On commercial extrusion blow-molding lines, DMDA-8907 HEALTH+ is processed at melt temperatures commonly between 180°C and 220°C, with die temperatures held near the upper end of that interval to reduce melt fracture and surface haze. The low melt-flow rate of 0.07 g/10 min provides sufficient parison hang time for blow-up ratios from 2.0:1 to 3.5:1 on shuttle and rotary machinery. Accumulator-head machines are preferred when wall-thickness uniformity is the controlling quality criterion. Reciprocating screw shuttle machines are more common for smaller bottles below 250 mL, but die-head hang-up and parison sag must be controlled more tightly on those systems. Die gap adjustments typically range from 1.0 mm to 2.5 mm depending on tooling diameter and container weight. Parison programming is required for non-cylindrical containers to prevent thin-out at the base and neck finish. A processing conflict arises from the same molecular weight that increases melt strength. Shear heating becomes significant in extruders with L/D ratios above 24:1, and screw speed must be limited to avoid melt temperatures above 230°C. Above 230°C, oxidative chain scission generates low-molecular-weight odor bodies and may elevate extractables beyond the levels established in the HEALTH+ data package. Drying is not normally required unless pellets are stored under high relative humidity or moved from cold storage. Surface moisture on the pellet bed can produce splay and pit defects. When condensation is present, desiccant drying at 60–70°C for 2 h is typical for polyolefin pellets. Processors should monitor regrind quality because reground HDPE lowers the effective molecular weight and reduces parison stability. Regrind addition above 30 wt% is generally not recommended unless engineering data demonstrate retained regulatory extractables performance. Additives, external lubricants, colorants, and processing aids must be qualified against Ph. Eur. 3.1.3 additive restrictions because the base-resin compliance package does not cover foreign additive systems. In multi-cavity production, batch-to-batch variation in melt-flow rate can appear as top-to-bottom wall-thickness variation and neck finish unevenness. Operators should trend melt pressure and parison length with each lot rather than assuming fixed machine settings.

    When DMDA-8907 HEALTH+ is substituted for general-purpose HDPE on an existing line

    Substitution is typically driven by the need for a healthcare-grade data package rather than by a requirement for higher stiffness or barrier. Compared with general-purpose HDPE blow-molding grades in the 0.3–0.7 g/10 min melt-flow interval, DMDA-8907 HEALTH+ trades lower flow for higher melt strength and improved parison stability. Existing tools may require an increase of 10–15°C in melt temperature to achieve equivalent fill, and low-torque machines may require derating of output by as much as 20%. The density of 0.952 g/cm³ is similar to standard HDPE bottle grades; water-vapor transmission is therefore in the range expected for high-density polyolefins, while oxygen transmission measured under ASTM D3985-17 will be significantly higher than for PET or multilayer structures. HDPE is semi-crystalline and generally yields translucent containers. If clarity is a market requirement, clarified polypropylene or injection-stretch blow-molded PET is more appropriate. The resin’s barrier and mechanical position makes it suitable for moisture-sensitive solid-dose formulations but not for oxygen-sensitive formulations requiring high gas barrier. Compared with polypropylene random copolymer packaging grades, DMDA-8907 HEALTH+ typically has higher density and lower flexural modulus at equivalent wall thickness, lower stiffness but better resistance to environmental stress cracking in many aqueous formulations. Compared with low-density polyethylene, the higher density and lower extractable potential from short-chain branching are advantages for pharmacopeial use, but clarity and flexibility are reduced. Within the manufacturer’s HEALTH+ family, selection is controlled primarily by molecular weight and container size. Grades with melt-flow rates near 0.07 g/10 min are typically assigned to containers requiring high stress-crack resistance and wall-thickness uniformity at larger capacities. Higher-flow HEALTH+ grades may be used for smaller, thin-walled bottles at faster cycles. The choice between HDPE and polypropylene for a pharmaceutical package is therefore controlled by closure performance, moisture barrier, and stress-crack resistance rather than by melt-flow rate alone.

    Lot-to-lot variance, storage conditions, and additive incompatibility

    The resin is supplied with lot-level certificates of analysis; controlled parameters include melt-flow rate, density, and selected extractables or organoleptic indicators where applicable. A density increase of only 0.002 g/cm³ can shift container weight and top-load crush strength enough to require wall-thickness adjustment. Top-load crush resistance can be monitored on finished containers under ASTM D2659-16, and moisture vapor transmission rate can be measured under ASTM F1249-20. Warehousing should maintain pellet temperatures below 40°C, avoid direct ultraviolet exposure, and keep packaging sealed to prevent contamination by aromatic processing aids or unintended lubricants. HDPE is not hygroscopic, but exposure to hydrocarbon vapors can alter surface organoleptic properties and extractables. The product should be segregated from incompatible additive classes, particularly halogenated flame retardants, strong oxidizing agents, and non-approved external mold releases. These materials can migrate into the polymer matrix during storage or processing and invalidate the regulatory data package. The operational boundary for the base resin is not defined by a single property cliff; instead, the critical limits are melt temperature (230°C), regrind ratio (30 wt%), and additive purity. The resin is not certified as a material for implantable device components under ISO 10993-1:2018; such use would require formal biological evaluation of the final article.
    Top