| HS Code | 612712 |
| Density | 1.18 g/cm³ |
| Flameretardancyrating | UL94 V-0 |
| Tensilestrength | 45 MPa |
| Elongationatbreak | 20% |
| Flexuralstrength | 70 MPa |
| Flexuralmodulus | 2200 MPa |
| Izodimpactstrength | 15 kJ/m² |
| Heatdeflectiontemperature | 85 °C |
| Vicatsofteningtemperature | 95 °C |
| Meltflowrate | 10 g/10 min |
| Moldingshrinkage | 0.4-0.6% |
| Waterabsorption | 0.2% |
As an accredited Dongguan Pule Plastic ABS PL-FR813 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Dongguan Pule Plastic ABS PL-FR813 is supplied in 25 kg moisture-resistant bags, palletized for industrial shipping. |
| Container Loading (20′ FCL) | Dongguan Pule Plastic ABS PL-FR813 loaded in a 20′ FCL, palletized, shrink-wrapped, labeled, and moisture-protected for safe transport. |
| Shipping | Dongguan Pule Plastic ABS PL-FR813 is generally shipped as a non-hazardous plastic resin in sealed bags or cartons. It is not classified as dangerous goods for transport. Store and transport in a cool, dry, ventilated area, away from moisture, direct sunlight, and ignition sources. |
| Storage | Store Dongguan Pule Plastic ABS PL-FR813 in a cool, dry, well-ventilated area away from direct sunlight, heat, flames, and strong oxidizers. Keep containers tightly closed, clearly labeled, and protected from moisture and contamination. Avoid dust generation, use appropriate personal protective equipment, store only in original packaging, and follow local regulations and the supplier’s safety data sheet. |
| Shelf Life | Shelf life of Dongguan Pule Plastic ABS PL-FR813 is typically 24 months when stored dry, cool, and in original sealed packaging. |
For miniature circuit breaker shells and low-voltage distribution box covers, specifying Dongguan Pule Plastic ABS PL-FR813 requires pre-drying in a desiccant dryer with a dew point below -30 °C. Moisture is reduced below 0.05 % before the pellets enter the screw feed throat. Failure to pre-dry at 80 °C for 3 h to 4 h allows hydrolysis at the 200 °C to 230 °C melt processing temperature. The visible result is splay at the gate land and around ejector pin bosses. A reciprocating screw with an L/D of 20:1 to 22:1 and a free-flow non-return valve is used because brominated flame-retardant compounds are residence-time sensitive. Shot size is kept between 50 % and 80 % of barrel capacity in production; smaller shots increase residence time and larger shots create pressure loss across the check ring. Back pressure is set at 0.3 MPa to 0.7 MPa to purge volatiles without over-shearing the melt. Mould temperature is controlled from 50 °C to 80 °C to reduce knit-line weakness in breaker shell bosses. Closed-loop regrind is limited to 20 % by weight only when the regrind is identical in colour, dried identically, and has not passed through three heat histories. Beyond this threshold, melt viscosity decreases and gloss differences become visible on textured surfaces. Terminal parts include miniature circuit breaker covers, energy meter terminal shrouds, distribution-box lids and busbar insulation supports. Compliance in this downstream segment is anchored to UL 94 V-0 at 1.5 mm thickness and to IEC 60695-2-11:2021 glow wire end-product testing. Parts in unattended equipment enclosures may require 850 °C glow wire with no ignition and no flame persistence exceeding 30 s. RoHS 2011/65/EU Annex II and REACH SVHC documentation must accompany each shipment for EU-bound enclosures.
Socket base plates and switch housings made from PL-FR813 are moulded with a wall thickness of 2.0 mm to 2.5 mm around brass terminal slots. The polymer is pre-dried to 0.04 % moisture or lower; below that threshold, surface gloss remains uniform across textured ribs. The cylinder temperature profile is set to 190 °C at the feed zone, 215 °C at the metering zone and no more than 240 °C at the nozzle; higher nozzle temperatures cause yellowing and reduce the 20 mm vertical burn performance. A three-plate cold runner with a cavity count of 8 to 16 is used. Hot runners are limited to externally heated manifolds with no dead spots because stagnant resin in dead spots releases flame-retardant degradation products. Clamp force is calculated at 3 t/in² to 5 t/in² projected area. Mould temperature is 50 °C to 70 °C; lower temperatures shrink the process window and increase sink marks around screw bosses. The regrind ratio is capped at 15 % because the wiring-device segment requires consistent screw bearing strength and low brittleness during installation. Terminal products are wall switch housings, socket base plates, shuttered socket covers, and fused spur boxes. Compliance in this segment is governed by IEC 60884-1:2022 for socket-outlets, IEC 60669-1:2017/AMD1:2020 for switches, and IEC 60695-2-11:2021 for glow wire performance at 850 °C in unattended appliance circuits. Products requiring UL 94 V-0 are tested at the minimum moulded wall thickness of 1.5 mm; thickness variation below that invalidates the classification.
| Hazard | Standard designation | Test condition | Acceptance criterion |
|---|---|---|---|
| Vertical burning | UL 94 | 20 mm vertical burn, 1.5 mm specimen | V-0 |
| Glow wire flammability index | IEC 60695-2-12:2021 | 750 °C / 850 °C | No ignition |
| Glow wire ignition temperature | IEC 60695-2-13:2021 | Report GWIT | As per end-product standard |
| Tracking resistance | IEC 60112:2020 | CTI test solution A | Material CTI class as per supplier certification |
When battery pack housings are specified for portable tools, power banks and e-bike chargers, PL-FR813 is processed with a wall thickness of 1.2 mm to 2.0 mm to meet fire enclosure requirements without paying the full cycle time penalty of thicker PC/ABS. The material is dried at 80 °C for 4 h in a desiccant dryer with a dew point below -40 °C because moisture above 0.05 % produces voiding at the battery retention ribs. A mould temperature of 60 °C to 80 °C is used to achieve the snap-fit dimensional stability required for removable pack shells. Melt temperature is set at 210 °C to 230 °C; the upper limit is 235 °C because higher temperature accelerates migration of brominated additives to the surface and creates a white haze on dark-coloured shells. Processing equipment uses a screw with a mixing tip of 2.5:1 compression ratio and 22:1 L/D, and the rotation speed is controlled from 60 rpm to 120 rpm to avoid excessive shear that reduces impact strength at the screw boss weld line. Regrind is limited to 10 % by weight for battery pack housings because the snap-fit hinge points are sensitive to reduced elongation and notched Izod loss after multiple heat histories. Terminal products are power tool battery shells, e-bike charger housings, portable power station front panels and power bank enclosures. Compliance in this segment uses UL 94 V-0 at 1.5 mm for the polymer, IEC 62368-1:2023 Clause 6.5 for fire enclosure integrity in ICT-adjacent charger products, and UN 38.3 for the completed battery pack; the plastic itself is not the cell safety device. A continuous service temperature above 80 °C inside the pack invalidates this material choice, and published data for PL-FR813 in this specific configuration is limited and should be confirmed against supplier thermal ageing data.
Across telecom rack faceplates and data outlet frames, PL-FR813 is specified for 1.0 mm to 1.6 mm walls. In this segment the limiting factor is not melt temperature but gate freeze-off and sink mark control around jack apertures. Melt temperature is held at 225 °C to 235 °C; mould temperature is set at 70 °C to 80 °C to delay skin freeze and replicate texture. The sprue-to-gate pressure drop is kept below 90 MPa, and filling analysis is normally required when flow length exceeds 150 mm at 1.2 mm wall because fountain flow stalls at the deep ribs. Hot runners are direct-gate units with valve pins; conventional hot-runner drops can degrade the flame-retardant package in 8 min to 12 min of residence time if the manifold temperature exceeds 240 °C. Screw speed is kept below 100 rpm for 35 mm to 50 mm screw diameters. Regrind is limited to 10 % for visible faceplates and 20 % for hidden brackets. The flame retardant chemistry demands stainless steel mould inserts for long production runs; flame-retardant decomposition products can corrode unplated cavities after 20,000 cycles. Compliance is tied to UL 94 V-0 at 1.5 mm and IEC 62368-1:2023 fire enclosure requirements. For products installed in plenum spaces, the relevant regional code may require UL 2043 smoke and heat release documentation, although flame-retardant ABS is generally not a plenum-rated resin without specific compound approval. Terminal products include rack mount front panels, keystone jack faceplates, network switch front bezels and optical network terminal enclosures.
In high-cavitation power adapter and smart home hub tools, ambient relative humidity above 60 % combined with chilled water lines set below the dew point produces condensate on the cavity surface. The condensate mixes with flame-retardant volatiles and forms a sticky film on the cavity surface. The film is often misdiagnosed as mould release residue. PL-FR813 must be dried to 0.04 % moisture or below; the drying hopper setpoint is 80 °C, with 4 h minimum residence in a desiccant bed unit delivering a dew point below -30 °C. After drying, hot pellets are not left in open tote boxes longer than 30 min before entering the hopper in humid plant air; otherwise surface moisture re-absorbs and produces splay at the gate. The melt temperature window is 210 °C to 230 °C; the nozzle should not exceed 240 °C because brominated FR degradation forms carbonaceous particles that block the gate land. Barrel zones are held within ±2 °C of setpoint. Injection speed is profiled with a short first stage at 40 mm/s to 80 mm/s and a packing phase of 80 MPa to 100 MPa hydraulic pressure; high packing stress around screw bosses generates ejection cracking when the part is de-moulded at 70 °C or above. Mould open and part extraction are automated with robot vacuum cups because thin-wall parts release from the core only within a narrow temperature window. The regrind ratio in this segment is limited to 15 %; recycled adapter shells from high-cavitation tools often carry trace oil from mould release and must be re-dried separately before blending. Do not blend PL-FR813 with amine-containing color concentrates or polyamide regrind; amine species can interfere with the brominated flame-retardant system and shift the UL 94 V-0 classification. Terminal products include smart speaker enclosures, Wi-Fi router housings, power adapter shells, and video doorbell mounting plates. Compliance is driven by UL 94 V-0 at 1.5 mm, IEC 62368-1:2023 for audio/video and information technology fire enclosure, and EN 60335-1 for household appliance relevant housings if the adapter is supplied with a domestic appliance. In the latter case, glow wire per IEC 60695-2-11:2021 at 750 °C or 850 °C may apply depending on unattended current.
Within household appliance control compartments, PL-FR813 is used for internal control housings with wall sections between 2.0 mm and 3.0 mm to provide stiffness around PCB standoffs and wiring strain reliefs. The material is processed at a melt temperature of 200 °C to 220 °C; lower melt temperature is preferred in thick sections to avoid sink marks and internal voids. Mould temperature is set from 40 °C to 60 °C; higher mould temperature increases cycle time without improving the UL 94 V-0 rating in thick-section parts. A cold runner system with edge gates is used; the gate diameter is kept above 1.0 mm to allow adequate packing without excessive shear heating. Hold pressure is set to 60 % to 80 % of the injection pressure, and hold time is calculated from the part mass, typically 6 s to 12 s for 2.5 mm thick control housings. The material is dried to 0.05 % moisture at 80 °C for 3 h; high humidity campaigns require 4 h. Regrind inclusion is permitted up to 25 % by weight for non-appearance internal housings if the regrind is produced from identical material and dried separately. Terminal products are control board housings, terminal block covers, sensor brackets and wiring junction boxes inside domestic appliances. This application relies on IEC 60335-1:2020 Clause 30 fire resistance testing and IEC 60695-2-11:2021 glow wire tests at 750 °C or 850 °C depending on the part location and current flow. For current-carrying parts within 3 mm of connections, the higher glow wire temperature generally applies. The material is not recommended for continuous immersion in wash liquor; seals and elastomer barriers are required in wet appliance compartments.
Competitive Dongguan Pule Plastic ABS PL-FR813 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Dongguan Pule Plastic ABS PL-FR813 is a flame-retardant acrylonitrile-butadiene-styrene molding compound intended for injection molding and extrusion segments where compliance with UL 94 V-0 is a design precondition. The grade is classified within the bromine-based flame-retardant ABS family, retaining the polybutadiene impact-modifier phase while the styrene-acrylonitrile continuous phase is modified with a halogenated/antimony-synergist package. Independent third-party characterization of this exact commercial formulation is not broadly indexed in the public literature; therefore, numerical values and processing windows cited herein are class-level ranges for bromine-modified flame-retardant ABS, not a substitute for the supplier’s lot-specific certificate of analysis.
Specification review should address melt volume-flow rate under ISO 1133-1:2022, density under ISO 1183-1:2019, tensile properties under ISO 527-2:2012, flexural modulus under ISO 178:2019, Charpy notched impact under ISO 179-1eA:2023, Vicat softening under ISO 306/B50, and vertical burn classification under UL 94:2023. The fire-test result is not an intrinsic property; it is thickness-dependent, specimen-conditioning-dependent, and tied to molded surface quality. A compound may pass V-0 at 1.5 mm nominal wall thickness and fail at 0.8 mm. Published data for this specific configuration of PL-FR813, including exact lot-to-lot flow and impact limits, is limited; receipt inspection should therefore rely on the manufacturer’s current technical datasheet and certificate of analysis.
| Property | Test standard | Typical specimen or conditioning |
|---|---|---|
| Melt volume-flow rate | ISO 1133-1:2022 | 220 °C / 10 kg, dried granules |
| Density | ISO 1183-1:2019 | 23 °C, injection-molded chip |
| Tensile stress at yield | ISO 527-2:2012 | Type 1A, 5 mm/min |
| Flexural modulus | ISO 178:2019 | 80 mm × 10 mm × 4 mm, 2 mm/min |
| Charpy notched impact strength | ISO 179-1eA:2023 | Type 1 eA, 23 °C / 50% RH, 88 h |
| Heat deflection temperature | ISO 75-2:2013 method A | 1.8 MPa, flatwise |
| Flammability | UL 94:2023 | 125 mm × 13 mm × 1.5 mm, conditioned 48 h at 23 °C / 50% RH |
Before processing, the granulate should be dried to a residual moisture target of ≤0.02% using a desiccant-hopper dryer at 80–90 °C for 3–4 h. Inlet-air dew point should be maintained at ≤−30 °C, and the process-air flow should be sized for the kilogram-per-hour throughput to prevent moisture-induced splay and surface defects. Extended hopper residence at low throughput must be avoided because the brominated package can undergo thermal darkening and plate-out when exposed to 230–240 °C barrel temperatures for more than 10–15 min of total residence time. Shot size should be controlled within 40–75% of barrel capacity to limit thermomechanical history.
Melt temperature at the nozzle should be held within 200–230 °C. A general-purpose three-zone screw with 20:1–25:1 L/D ratio and a reverse barrel profile above the feed zone can be used, with back pressure in the range of 0.3–0.7 MPa and screw rotation sufficient to deliver 40–80 rpm without excessive shear heating. Mold surface temperature should be held at 40–70 °C; lower temperatures reduce gloss and increase weld-line visibility in thin ribs, while higher temperatures assist pressure transmission but extend cooling time. Injection velocity should be profiled for 1.5–2.5 mm nominal wall sections to reduce jetting. Pack pressure is typically maintained at 50–70% of first-stage injection pressure to control sink and warpage without overpacking.
Regrind use is permitted only after confirmation that no more than 20% of dried, uncontaminated regrind is reintroduced into the feed stream; higher addition rates can alter viscosity, flame performance, and notched impact retention. If regrind is used, the UL 94 rating must be re-verified at the same nominal wall thickness and specimen conditioning specified in the end-use standard. Mold corrosion from trace hydrogen bromide released at elevated melt temperature is an operational consideration; vented barrel and tooling configurations are recommended when processing at the upper end of the melt-temperature band.
General-purpose ABS without a flame-retardant package typically exhibits a UL 94 HB classification and a melt density of 1.04–1.07 g/cm³. Bromine-antimony-modified grades such as PL-FR813 shift combustion chemistry toward gas-phase radical quenching and char formation, but the additive package raises melt density into the class range of 1.17–1.22 g/cm³, narrows the processing window, and increases combustion smoke and soot. Halogen-free flame-retardant ABS often uses phosphorus- or melamine-based systems and may require higher additive loadings to achieve V-0, which can depress notched impact strength and reduce melt flow relative to a brominated system at equivalent wall thickness.
The comparison below is class-level and is not a lot-acceptance tool. PL-FR813 may contain antimony trioxide; antimony content creates opacity and influences laser welding, laser marking, and ultrasonic welding behavior. Halogen-free alternatives are frequently selected for low-smoke rail or electronics applications, but they may impose higher melt viscosity, greater mold deposit, and different shading behavior in thin-wall components.
| Attribute | General-purpose ABS | PL-FR813 class | Halogen-free FR ABS |
|---|---|---|---|
| Flame classification | UL 94 HB | UL 94 V-0 at 1.5 mm typical class | UL 94 V-0 at 1.5 mm achievable |
| Density | 1.04–1.07 g/cm³ | 1.17–1.22 g/cm³ | 1.14–1.22 g/cm³ |
| Melt-temperature window | 210–260 °C | 200–230 °C | 190–230 °C |
| Notched impact retention | High | Intermediate | Lower to intermediate depending on filler |
| Light stability | Moderate to high | Moderate | Moderate |
| Smoke and soot under combustion | Lower | Higher | Lower to moderate |
| Colorability and transparency | Broad color range; some transparent grades | Opaque; antimony limits light transmission | Opaque; loading-dependent |
Applications for PL-FR813 are concentrated in electrical enclosures, power distribution units, battery charging housings, uninterruptible power supply frames, small appliance housings, and industrial control panels where UL 94 V-0 at 1.5 mm is an enclosure-level compliance requirement. The grade should not be exposed to outdoor UV weathering without a capstock, co-extruded layer, or UV-protective coating because the polybutadiene phase retains known susceptibility to photo-oxidative embrittlement. Chemical resistance is acceptable for dilute aqueous acids and bases at room temperature, but continuous contact with ketones, chlorinated solvents, esters, or aromatic hydrocarbons is not recommended; environmental stress-cracking resistance in the presence of these media should be assessed using ISO 22088-2 notched specimen exposure.
The material is not intended for food-contact or medical applications unless a written migration and biocompatibility report against FDA 21 CFR or Regulation (EU) No 10/2011 is supplied for the specific lot and processing conditions. Storage should be in original sealed containers at 5–35 °C and <65% RH, with a use-before period of 12 months from the date of manufacture unless otherwise stated in the supplier’s documentation.
Flame-retardant ABS compounds are frequently audited under Directive 2011/65/EU Annex II recast RoHS restrictions. The relevant homogeneous-material limits are 1000 mg/kg for lead, mercury, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers, with a lower limit of 100 mg/kg for cadmium, and 1000 mg/kg for each of the four restricted phthalates. PL-FR813 documentation should include screening data generated by IEC 62321-based methods when RoHS certification is required. Under REACH Regulation (EC) No 1907/2006, brominated flame retardants may be subject to authorisation, restriction, or candidate-list screening; the compliance statement must reference the current Candidate List and Annex XVII entries relevant to the declared formulation.
Antimony trioxide has a harmonised classification as a suspected inhalation carcinogen but remains permitted in fully polymerised plastic parts under RoHS when appropriate exposure controls are maintained at the conversion stage. Local exhaust ventilation at the molding machine hopper and barrel vent is recommended, and workplace antimony exposure should be maintained below the applicable ACGIH threshold limit value for antimony compounds, commonly 0.5 mg/m³ as Sb for an 8 h time-weighted average. The same engineering controls address trace hydrogen bromide off-gassing during emergency venting or resin degradation.
Laboratory tensile testing should follow ISO 527-2:2012 with type 1A specimens at 5 mm/min, while flexural modulus is determined at 2 mm/min using 80 mm × 10 mm × 4 mm specimens under ISO 178:2019. Notched Charpy impact strengths obtained under ISO 179-1eA:2023 should be generated from specimens conditioned at 23 °C / 50% RH for 88 h. Half-load and full-load heat deflection values must not be compared: ISO 75-2:2013 method A is the appropriate basis for load-bearing thermal comparisons, while method B data are acceptable only for relative ranking under lower stress.
Molded density should be measured after 24 h conditioning under ISO 1183-1:2019, and mold shrinkage should be reported after 24 h using ISO 294-4, with the exact flow orientation and gate type recorded. Melt flow-rate data without drying and temperature calibration are invalid for batch comparison because residual moisture and thermal history can shift apparent viscosity. Published data for PL-FR813 in independent comparative studies is limited; consequently, the supplier’s certificate of analysis and molded specimen retention protocol are the controlling references for resolving lot-to-lot variation.
Process audits should record nozzle melt temperature, barrel residence time, hopper dryer dew point, screw speed, back pressure, and mold coolant inlet temperature. These variables interact with the brominated flame-retardant package: excessive shear can break down the impact-modifier phase, whereas insufficient melt temperature produces poor flow marks and weak weld lines in thin-wall electrical enclosures. When the molding process shifts outside the validated window, flame classification and notched impact must be re-tested at the same thickness and conditioning used for the original component qualification.