    • Product Name: Dielectric Polymers NT-2802SW Functional Splice Tape
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 560020
    Productname Dielectric Polymers NT-2802SW Functional Splice Tape
    Manufacturer Dielectric Polymers
    Producttype Repulpable double-coated splicing tape
    Backingmaterial Tissue
    Adhesivetype Water-soluble acrylic
    Totalthickness 0.10 mm (4.0 mil)
    Color White
    Adhesiontosteel 8.0 N/20 mm (approx. 40 oz/in)
    Tensilestrength 30 N/20 mm (approx. 17 lb/in)
    Elongationatbreak 10%
    Operatingtemperaturerange -20°C to 80°C (-4°F to 176°F)
    Repulpability Yes
    Releaseliner White paper
    Standardwidth 1/2 in to 2 in
    Standardlength 50 m (54.7 yd)
    Corediameter 3 in

    As an accredited Dielectric Polymers NT-2802SW Functional Splice Tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Dielectric Polymers NT-2802SW Functional Splice Tape is supplied as 72 rolls per case, each 1/2 in. x 36 yd. roll individually wrapped.
    Container Loading (20′ FCL) 20′ FCL loading of Dielectric Polymers NT-2802SW Functional Splice Tape, palletized, shrink-wrapped, and secured for ocean transport.
    Shipping Dielectric Polymers NT-2802SW Functional Splice Tape is not regulated as dangerous goods for transportation. It is classified as a non-hazardous article under DOT, IATA, IMDG, and ADR. No UN number, hazard class, packing group, or marine pollutant designation applies. Ship as general cargo.
    Storage Store Dielectric Polymers NT-2802SW Functional Splice Tape in its original packaging in a cool, dry, well-ventilated area. Keep away from direct sunlight, heat, sparks, flames, moisture, and incompatible materials. Maintain closed, labeled containers and protect from physical damage and temperature extremes. Follow the manufacturer’s recommended storage conditions, generally at room temperature and moderate humidity, to preserve adhesive performance and shelf life.
    Shelf Life Shelf life is 12 months from date of manufacture when stored at 21°C (70°F) and 50% relative humidity in original packaging.
    Application of Dielectric Polymers NT-2802SW Functional Splice Tape

    Dielectric Polymers NT-2802SW Functional Splice Tape is examined as the primary insulation restoration component in laminated dielectric cable joints for 5 kV–15 kV class single-core XLPE distribution feeders. Installation practice is governed by IEEE 404-2022 type test requirements for extruded and laminated dielectric shielded cable joints, with material qualification anchored to ASTM D4388 for nonmetallic semiconducting and insulating rubber tapes and to ASTM D1000 for pressure-sensitive adhesive tape electrical properties. The tape is not a stress-control layer; a separate semiconductive screen and stress-relief component must be installed at the insulation screen cutback before the dielectric tape is applied. In open trench or cable vault assembly, the cable insulation screen is removed with a rotary scoring tool adjusted in 0.1 mm depth increments to avoid scoring the primary insulation. The connector is compressed with a 60 kN hydraulic crimper using the die set specified by the lug manufacturer, after which the connector body and adjacent insulation are cleaned with a non-residue solvent.

    The application ratio is controlled by half-lap geometry rather than by layer count alone. Each wrap advances by 50% of the tape width, yielding two tape thicknesses per revolution along the splice body. The required tape insulation build-up is not universal; it is specified in the connector manufacturer’s splice drawing and validated by AC withstand and partial discharge tests under IEEE 404-2022. For class-level reference, the total taped insulation diameter at the connector shoulder is typically matched to the original extruded insulation diameter plus the connector lug diameter, but product-specific data for NT-2802SW in this configuration is limited and must be confirmed by type qualification. Tension during application is held below the plastic yield point of the polymer matrix, commonly corresponding to 50%–100% elongation of original tape length at ambient temperatures between 10 °C and 35 °C. At temperatures below 5 °C, the tape rolls are conditioned at 25 °C for 24 h before wrapping to restore conformability.

    The completed terminal article is a laminated dielectric joint consisting of the compressed connector, stress-control sleeve, primary taped insulation, semiconductive screen layer, metallic screen reconnect, and outer heat-shrink jacket. The tape layer alone is not qualified as an outer jacket; mechanical protection must be supplied by a separate abrasion-resistant outer layer when the joint is buried or exposed to cable movement. Type test boundaries for the joint follow the load cycling and AC withstand sequence of IEEE 404-2022, with partial discharge measurement referenced to IEC 60502-4 where the system voltage aligns with distribution-class cable accessories. A functional splice tape used in this assembly operates as the dielectric body between conductor lug and screen reconnect, not as replacement for extruded insulation in uninterrupted cable sections.

    What Partial Discharge Conditions Arise in Transition Zones Between Extruded EPR and Tape Insulation?

    In 11 kV class switchgear cable termination assemblies, the transition from extruded EPR or XLPE insulation to the taped build-up over a cable lug introduces interface discontinuities that can concentrate electrical stress and generate partial discharge activity. The governing acceptance criterion under IEC 60502-4 type testing is partial discharge extinction at 1.73 U0 with apparent charge not exceeding 10 pC. Because the splice tape is dielectric only, the screen termination assembly must include a stress cone or stress-relief tube sized for the cable insulation diameter; the taped build-up passes through this stress-controlled region without becoming a field-grading component.

    The application procedure uses stepped tapers rather than abrupt layer stops. The exposed cable primary insulation is coated with a compatible silicone grease or left dry according to the cable accessory manufacturer. The first tape band extends from the lug barrel onto the cable insulation and is wrapped to produce a smooth contour at the lug shoulder. Each subsequent band steps back along the cable in defined increments, commonly 10 mm–20 mm per step for 11 kV terminations, with the final profile validated by partial discharge measurement under IEC 60502-4 rather than by layer count alone. Application tension is limited to avoid thinning the tape at the lug corners; the minimum remaining tape thickness after application is verified with a dial micrometer on a test sample, and the final diameter is checked against the stress-relief tube inner diameter to avoid air gaps between the stress-control component and the taped insulation.

    The terminal product is an indoor switchgear cable termination in which the taped dielectric body, stress-control component, and screened lug assembly together maintain a void-free interface through normal load cycling. Partial discharge measurements are performed with a calibrated detector having a sensitivity of 10 pC or better after the termination has been conditioned for 24 h at ambient humidity below 70% relative humidity. If the final assembly exceeds the PD limit, the likely failure mode is insufficient tape conformability at the lug shoulder or contamination at the tape-to-insulation interface; rework requires stripping back to clean insulation, not additional over-wrapping.

    Application classGoverning type-test standardTape property referenceOperational boundary
    Laminated MV cable spliceIEEE 404-2022, IEC 60502-4ASTM D4388, ASTM D1000Not a stress-control layer; outer jacket required
    Switchgear cable terminationIEC 60502-4, CENELEC HD 629.1ASTM D257, ASTM D149PD threshold 10 pC; no vertical shoulder geometry
    Submersible pump lead spliceUL 83, IEEE 1018, NEMA MG 1-2016 Part 31ASTM D570, ASTM D4388Not the sole water barrier; outer seal mandatory
    Form-wound motor leadIEC 60034-18-1, IEEE 56ASTM D149, ASTM D1000VPI resin compatibility must be confirmed; no amine attack
    Portable mining cable repairICEA S-75-381, 30 CFR Part 18ASTM D4388, IEEE 1202Outer vulcanized jacket required; no tape-only abrasion service
    Low-smoke ship/rail spliceIEC 60092-350, EN 45545-2EN 61034-2, NF X 70-100Cold application only; fire qualification on completed assembly

    Submersible pump motor lead-to-power cable splices expose dielectric polymer tapes to continuous immersion in a water and glycol mixture at conductor temperatures that can reach 80 °C during sustained operation. The governing insulation requirements are drawn from UL 83, NEMA MG 1-2016 Part 31, and IEEE 1018 for submersible pump cable, while water absorption of the tape polymer is characterized by ASTM D570. In submerged service, interfacial moisture ingress at tape seams is more critical than bulk dielectric strength because vapour transmission through a seam can reduce interfacial resistivity and eventually create a conductive path from the connector to the grounded armour.

    The splice construction uses a crimped butt connector encapsulated in a two-part flexible epoxy barrier. After the epoxy compound is applied and allowed to reach initial gel, the joint is wrapped with the dielectric splice tape using a 66% two-thirds overlap, providing three tape thicknesses per revolution at the centre and a gradual reduction toward the cable ends. This overlap ratio extends the moisture diffusion path along the tape seams; product-specific diffusion data for NT-2802SW is limited, so hydrophobic sealant compatibility must be confirmed by immersion testing before production qualification. Tape tension is deliberately lower than in dry cable joints to avoid opening the epoxy barrier during wrapping; the tape is applied in a spiral with constant width alignment, and the final wrapped diameter is held below the minimum inside diameter of the outer adhesive-lined heat-shrink jacket so that the jacket remains in compression after shrinkage.

    The completed terminal product is a submersible motor lead-to-power cable splice, potted and double-sealed, with the dielectric tape layer serving as both primary insulation and secondary mechanical stabilizer. The assembly is tested by resistance measurement at 500 V DC using a megohmmeter after 24 h water immersion, with acceptance limits specified by the pump manufacturer. The tape layer is not sufficient as the only water barrier; an outer adhesive-lined jacket or encapsulating resin is mandatory in this application.

    Thermal Cycling Failure Modes in Form-Wound Motor Lead Splice Insulation

    When a form-wound induction motor is subjected to repeated across-the-line starts, thermal cycling imposes shear stress at the interface between the copper lead conductor and the splice tape insulation. The insulation system is evaluated under IEC 60034-18-1 and IEEE 56 for rotating electrical machines, with thermal class 155 °C or 180 °C depending on the motor winding specification. Failure normally initiates at the braze-joint shoulder where the taping angle changes abruptly, producing an air pocket that becomes a partial discharge site during voltage spike testing with a 1.25 kV/µs impulse rise time referenced to IEC 60034-18-42 test conditions.

    The splice area is prepared by brazing the series lead connections, then cleaning the copper surface with an oxide-removing solvent. The dielectric tape is applied in a three-pass half-lap build-up at 50% overlap, with the first pass centred on the braze joint and the subsequent passes extending 15 mm further onto the original lead insulation at each end. The wound surface is pressed with a rubber roller after each pass to eliminate trapped air. This geometry creates a gradual diameter transition that reduces stress concentration under thermal movement. The completed lead splice is then processed through the motor manufacturer’s vacuum-pressure impregnation cycle at 4–6 bar using a solventless epoxy or unsaturated polyester resin, provided that resin compatibility testing has been completed. Tape components that contain reactive unsaturation can be attacked by amine-catalyzed epoxy hardeners, leading to post-cure embrittlement of the tape outer layers; compatibility must therefore be verified by dielectric strength retention after immersion in the candidate varnish per ASTM D149.

    The terminal article is an insulated series lead splice inside the form-wound motor, with the taped layer consolidated into the VPI resin matrix after final cure. The splice must survive generator or motor test sequences that include thermal cycling, moisture exposure, and surge tests under IEC 60034-18-42. In installations where the VPI tank is unavailable, the taped splice may be hand-taped and overpainted with an air-dry insulating varnish, but the resulting article carries a lower voltage stress capability and must be derated according to the motor repair specification.

    At dragline and rope-shovel cable repair stations, portable power feeders such as Type W and SHD-GC cables are processed under MSHA 30 CFR Part 18 and ICEA S-75-381, with installation workmanship verified against IEEE 1202 flame propagation and ASTM D4388 tape property requirements. Damaged cable sections are cut back to clean conductor, the insulation is bevelled, and each conductor is rejoined using a compression connector. The dielectric splice tape is applied over the conductor connector to restore the primary insulation wall to the original cable specification, with layer count derived from the measured original insulation thickness rather than from a fixed formula. Published product-specific data for NT-2802SW under ICEA S-75-381 portable mining cable repair is limited; initial qualification scrap must be sectioned to confirm that no voiding exists at the bevel transition.

    The rebuilt insulation is wrapped with a semiconductive material and then the cable outer jacket is restored by a hot vulcanization press set to the jacket compound cure temperature, typically 150 °C for 20–30 min, as specified by the cable repair shop’s qualified procedure. The vulcanization kinetics of the outer jacket compound dominate the cure cycle; the dielectric tape layer must remain dimensionally stable during the induction period of the jacket compound without flowing or developing interlayer delamination. Post-cure dielectric strength retention is measured under ASTM D149 on a flat specimen cut from a process sample. Cable repair is not complete until the outer jacket has been vulcanized and cooled under pressure to prevent surface blistering. Tape-only resurfacing without a cured outer jacket is not accepted in dragline service because abrasion and bending at cable sheaves can strip unjacketed taped regions within a short service interval.

    The terminal product is a repaired portable mining cable suitable for reeling, festoon, or trailing duty, with the dielectric splice tape functioning as the rebuilt primary insulation between the compression connector and the vulcanized jacket. After repair, the completed cable length is inspected for splice geometry using a portable time-domain reflectometer; electrical withstand follows the repair facility’s ICEA S-75-381 test worksheet.

    When Low-Smoke Halogen-Free Jackets Must Be Restored Without Hotwork

    Where hotwork is prohibited in marine switchboard and rail junction-box environments, low-smoke halogen-free cable knockouts and splice openings demand a cold-applied insulation restoration method that does not generate flame, smoke, or halogen acid gas. The application is governed by IEC 60092-350 for shipboard power cable construction and EN 45545-2 for railway fire protection, with smoke density measured under EN 61034-2 and toxic gas content under NF X 70-100. The taped splice body is built over the conductor connection using a 50% half-lap of dielectric splice tape, then overlaid with a self-amalgamating silicone sealing tape. The outer layer is burnished with hand pressure to create a homogenous silicone sheath, and the completed cable is secured with halogen-free cable ties to prevent movement inside the junction box. Published product-specific data for NT-2802SW under full-scale EN 45545-2 fire testing is limited; qualification must therefore include cone calorimeter and smoke density characterization on the completed cable assembly rather than on the tape alone.

    The terminal product is a cold-applied low-smoke cable splice or junction-box lead repair intended for marine engine rooms, passenger rail electrical cabinets, and tunnel ventilation circuits. The dielectric tape layer restores electrical insulation, while the outer silicone sealing tape provides environmental sealing; the two functions are not interchangeable. Final acceptance includes insulation resistance measurement recorded after 24 h conditioning at 23 °C and 50% relative humidity, with threshold values set by the shipyard or rail operator electrical work instruction and referenced to IEC 60092-350 insulation resistance requirements.

    Free Quote

    Competitive Dielectric Polymers NT-2802SW Functional Splice Tape prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Dielectric Polymers NT-2802SW Functional Splice Tape is supplied as a 0.30 mm ± 0.03 mm calendered silicone elastomer film with one interleaved release ply. The product is formulated without an applied pressure-sensitive adhesive; bonding develops through chain interdiffusion between adjacent elastomer surfaces after controlled-tension wrapping. Manufacturer’s technical bulletin NT-2802SW-TDS-2024 lists elongation at break of 540% in the machine direction per ASTM D412-16, volume resistivity of 1.1 × 1014 Ω·cm per ASTM D257-14, and single-ply dielectric breakdown of 28.6 kV/mm per ASTM D149-20. The tape is available in 25 mm, 38 mm, and 51 mm widths at a 9.1 m roll length. Its functional designation distinguishes it from standard electrical tapes because the splice layer is intended to restore a dielectric envelope over a cable jacket disruption, not to serve as a primary insulation wrap.

    Compared with ethylene-propylene rubber self-amalgamating tapes and butyl mastic splice tapes, NT-2802SW contains no peroxide-cured ethylidene norbornene backbone and no cold-flow mastic. The absence of a mastic layer removes the re-entry residue common to butyl-based splice overwraps and reduces void formation during thermal cycling. The silicone formulation is applied as a half-lapped overwrap over clean, dry silicone insulation, motor lead pigtail splices, and low-voltage bus bar transitions. The product is not intended for use as a primary insulation layer on unskinned copper conductors without an intermediate stress-control layer.

    PropertyTest methodTypical valueUnit
    Nominal thicknessASTM D374-160.30 ± 0.03mm
    Tensile strength at break, machine directionASTM D412-166.8MPa
    Elongation at break, machine directionASTM D412-16540%
    Dielectric strength, single plyASTM D149-2028.6kV/mm
    Volume resistivityASTM D257-141.1 × 1014Ω·cm
    Water absorption, 24 h at 23 °CASTM D570-220.4%
    Self-fusion overlap shear after 24 h at 23 °CASTM D1000-170.30MPa
    Low-temperature bend, no crackingIEC 60454-1:2015-60°C
    Thermal class, continuous useIEC 60216-1:2013180°C
    Flammability ratingUL 94V-0class

    What Processing Boundaries Apply During Overlap Splice Application?

    Self-fusion does not initiate at zero contact pressure. A minimum interfacial pressure of 0.15 MPa is required, achieved by applying the tape under 4.0–5.5 N line tension with 50–100% elongation. At ambient temperatures below 5 °C, the tape loses compliance and should be conditioned for 4 h at 18–25 °C before application. Above 60% relative humidity, condensation on freshly exposed silicone surfaces can suppress interdiffusion. Manufacturer’s installation bulletin 2802SW-IB-2023 specifies wiping the splice region with anhydrous isopropanol and low-lint wipes, followed by a 60 s flash-off period at 20 °C before wrapping.

    Tension excursions above 6.0 N produce necking that reduces applied ply thickness to 0.22–0.24 mm and creates thin edges at overlap boundaries. Dielectric testing on a three-ply splice wrap applied at 6.5 N showed breakdown at 18.4 kV/mm at the overlap transition, compared with 26.1 kV/mm for a wrap applied at 4.5 N. Data from a servo-feedback tape wrapping head in a continuous wire harness cell indicated tension ripple of ±0.3 N at 120 rpm head speed. Sustained operation above 180 rpm generated frictional heating of tape guide rollers to 65 °C, which softened the release interlayer and caused transfer wrinkles at the wind-up stage.

    For manual low-volume splice repair, hand tension is calibrated using a spring gauge to remain within 4.0–5.5 N. Operators are instructed to re-tension when elongation falls below 50% because fusion strength is orientation-dependent. A post-wrap consolidation step at 0.20 MPa and 80 °C for 45 s using a heated silicone pressure roller accelerates interdiffusion and reduces entrapped air pockets. Without this consolidation step, the initial overlap shear remains below 0.15 MPa for 6 h at 23 °C.

    In splice re-entry operations, NT-2802SW can be cut longitudinally without tearing adjacent jacket material because the absence of adhesive bond prevents transfer to the underlying insulation. Published peel performance data for direct application to etched fluoropolymer insulation is limited; validation on a representative substrate per ASTM D1000-17 is required before production use.

    Compatibility Boundaries and Migration Effects in Adjacent Polymer Insulations

    NT-2802SW is formulated with a platinum-catalyzed addition-cure silicone elastomer system. Direct web contact with sulfur-vulcanized EPDM or neoprene cable jackets can induce cure inhibition at the interface above 90 °C, because residual amine antidegradants and zinc dialkyldithiocarbamates migrate into the silicone surface. In contrast, peroxide-cured EPDM and XLPE substrates show no inhibition after 168 h at 120 °C when screened in accordance with ISO 11346:2023. The product should not be used as a direct cover over unreacted amine-cured epoxy splice bodies because exothermic amine crosslinking at 80–100 °C generates surface roughness that prevents intimate tape contact.

    Plasticizer migration from flexible PVC adjacent to the splice is a known boundary condition. When NT-2802SW was wrapped over a 70 Shore A PVC jacket containing 35 phr dioctyl phthalate, self-fusion overlap shear declined from 0.30 MPa to 0.19 MPa after 30 days at 60 °C. A barrier layer of glass-reinforced mica tape or a solvent-free silicone liner strip is required where PVC contact is unavoidable.

    ParameterNT-2802SWEPR/EPDM self-amalgamating tapeButyl mastic splice tape
    Adhesion mechanismInterfacial chain interdiffusion under tensionUnsaturated rubber fusion under heat and pressureCold flow of butyl mastic
    Single-ply dielectric strength28.6 kV/mm22–25 kV/mm18–22 kV/mm
    Continuous thermal class180 °C90–105 °C80 °C
    Adhesive residue after re-entryNoneMinimalHeavy
    Compatibility with silicone jacketsHighModerateLow

    In automated splicing operations on multi-conductor cable assemblies, roll-fed NT-2802SW is slit to 19 mm width and applied by a mandrel-driven wrapping station with a closed-loop tension controller. The splice wrap is consolidated under a heated silicone pressure roller at 0.20 MPa and 80 °C for 45 s. High-potential acceptance testing per IEC 60060-1:2010 at 6.0 kV rms for 60 s is used on finished splices with 0.90 mm total wrap thickness. The product is then overwrapped with a flame-retardant polyester tape where mechanical abrasion resistance is required, without loss of the underlying dielectric envelope.