Clariant Pepr92735g5nat Lldpe 5 Glass Fiber Chemically Coupled

Clariant PEPR92735G5NAT LLDPE, 5% Glass Fiber, Chemically Coupled

    • Product Name: Clariant PEPR92735G5NAT LLDPE, 5% Glass Fiber, Chemically Coupled
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 839969
    Productname Clariant PEPR92735G5NAT
    Manufacturer Clariant
    Material LLDPE
    Glassfibercontent 5%
    Chemicalcoupling Yes
    Color Natural
    Density 0.950 g/cm³
    Meltflowrate 9.0 g/10 min
    Tensilestrengthatyield 24.1 MPa
    Tensilestrengthatbreak 41.4 MPa
    Elongationatbreak 9.0%
    Flexuralmodulus 1.93 GPa
    Flexuralstrength 55.2 MPa
    Notchedizodimpact 53.4 J/m
    Unnotchedizodimpact 534 J/m
    Heatdeflectiontemperatureat1 8mpa 93.3 °C
    Meltingpoint 125 °C
    Processingmethod Injection Molding
    Processingtemperature 190-230 °C
    Moldtemperature 20-60 °C
    Moldshrinkageflow 0.005 cm/cm
    Moldshrinkagetransverse 0.010 cm/cm

    As an accredited Clariant PEPR92735G5NAT LLDPE, 5% Glass Fiber, Chemically Coupled factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Clariant PEPR92735G5NAT LLDPE, 5% Glass Fiber, Chemically Coupled comes in 25 kg polyethylene-lined paper bags, 40 bags per pallet (1,000 kg).
    Container Loading (20′ FCL) 20′ FCL container loading for Clariant PEPR92735G5NAT LLDPE, 5% glass fiber, chemically coupled: palletized bags, shrink-wrapped, secured for ocean shipment.
    Shipping Clariant PEPR92735G5NAT LLDPE with 5% glass fiber and chemical coupling ships as non-hazardous polymer pellets. It is not regulated for DOT, IMDG, or IATA transport. Package in sealed moisture-barrier bags or boxes; keep dry, clean, and at ambient temperature. Avoid excessive heat, UV, and contamination.
    Storage Store in a cool, dry, well-ventilated warehouse away from direct sunlight, heat, and ignition sources. Keep original containers or liners tightly sealed to prevent moisture pickup and contamination. Avoid excessive stacking, crushing, or UV exposure. Maintain clean handling areas; segregate from incompatible materials. Follow the manufacturer’s SDS and local regulations for safe storage, housekeeping, and inventory rotation.
    Shelf Life Store in a cool, dry place in sealed containers; shelf life is typically 12 months from date of manufacture.
    Application of Clariant PEPR92735G5NAT LLDPE, 5% Glass Fiber, Chemically Coupled

    What Mould-Filling Pressures Govern Injection-Moulded Pallet and Crate Production?

    In returnable transport packaging, the transition from unfilled LLDPE to a 5% chemically coupled glass-fibre compound is driven by racking endurance limits and pallet bending stiffness rather than tensile yield. For injection-moulded export pallets and collapsible crates, mechanical verification includes ISO 8611-1 bending and corner drop protocols and ISO 8611-2 block stacking tests; static racking in beam storage is frequently specified at residual deflection below 2.0% after 800 kg load cycles on a EN 15512 racking frame with 1000 mm beam spacing. The compound is processed at 100 wt% when a flexural modulus of 1000–1300 MPa at 23 °C per ISO 178 is required. For large mouldings where flow length exceeds 800 mm, the compound is blended with an MFI-matched unfilled LLDPE at 30–50 wt% of total charge, reducing effective glass fibre content to 1.5–2.5 wt% and lowering melt viscosity to approximately 85–90% of the unfilled carrier measured at 190 °C/2.16 kg according to ISO 1133-1. Production is executed on accumulator-assisted injection moulding machines with 800–2500 t clamp force, a 25:1 L/D general-purpose screw, melt temperature 195–230 °C, mould temperature 15–40 °C, and holding pressure 60–100 MPa. Pre-drying at 80 °C for 2–4 h is required when storage relative humidity exceeds 60%. Moulded terminal articles include one-piece export pallets, collapsible distribution crates, dairy delivery cases, and injection-moulded hopper bins. The main processing conflict is warpage caused by fibre orientation at gate junctions; it is controlled with multiple pin gates rather than direct sprue gating, and gate spacing is kept below 300 mm to avoid anisotropic shrinkage.

    Automotive HVAC Duct Wall Rigidity, Creep, and Flammability Compliance

    Because automotive interior parts must retain shape after heat ageing without exceeding cabin toxicity thresholds, 5% glass-coupled LLDPE is used in low-pressure air duct sections and seat base carriers where unfilled LLDPE would creep beyond dimensional tolerance. Compliance for the finished article starts with ISO 3795 or FMVSS 302 horizontal burn rate, typically limited to 100 mm/min; original equipment specifications frequently add VDA 278 thermal desorption limits for volatile and semi-volatile organics and ISO 4582 colour change after 1000 h xenon arc weathering. The compound is processed at 100 wt% for seat base frames requiring a flexural modulus above 1100 MPa. For thin-wall HVAC ducts with wall thickness 1.5–2.0 mm, it is diluted with unfilled LLDPE at 50–70 wt% while retaining an effective glass content of 2.5–3.5 wt%. Injection moulding on 1200–2200 t machines uses melt temperatures 195–225 °C, hot-runner valve gates of 2.0–3.0 mm diameter, and filling velocities below 120 mm/s to limit glass fibre breakage at sharp duct radii. Terminal components include seat base frames, door panel carriers, trunk side trim, and HVAC ductwork. The operational boundary is continuous air temperature of 80 °C; above this, duct sections must be re-evaluated for sag under ISO 306 Vicat softening. Published data for this specific chemically coupled LLDPE in automotive UV and VOC screening is limited; therefore, final part validation is required at Tier 1 level before release.

    Electrical raceway sections extruded from LLDPE modified with short glass fibre are evaluated principally for dimensional stability under heat and for low-voltage insulation creep rather than tensile strength. The relevant installed-product standards are IEC 61386-1 and IEC 61386-21 for non-metallic rigid conduits, UL 94 HB at 3.0 mm thickness, IEC 60695-2-11 glow wire at 850 °C, and RoHS 2011/65/EU Annex II substance restrictions. The compound is processed at 100 wt% for rigid slotted wall cable ducts and inspection chamber covers that require flexural modulus above 900 MPa at 23 °C per ISO 178. For conduit with outer diameter ≤ 50 mm and wall thickness ≤ 2.5 mm, the compound is let down at 25–40 wt% with a high-molecular-weight LLDPE of melt index 1.0–2.0 g/10 min to maintain ring deflection resistance while extending continuous extrusion run time without melt fracture. Production uses single-screw extruders with 30:1 L/D and barrier screws at melt temperature 180–210 °C, die temperature 200–215 °C, and vacuum calibration at −0.6 to −0.8 bar to hold outer diameter within ±0.3 mm. Terminal parts include corrugated outdoor conduits, slotted wire ducts for control panels, underground cable junction boxes, and street lighting base covers. The main batch-to-batch variance is fibre distribution in thin walls; incoming lots are screened by ash content per ISO 3451-1 and melt flow rate per ISO 1133-1 before extrusion.

    When Vibration Damping and Cold Impact Resistance Govern Washing Machine Base Frames

    Vibration frequencies below 40 Hz in appliance bases transmit through injection-moulded materials as flexural fatigue, and unfilled LLDPE can accumulate set after repeated spin cycles; load-bearing geometry therefore demands a higher modulus without sacrificing weld-line impact strength. Electrical safety compliance for finished appliances is assessed under IEC 60335-1 and IEC 60335-2-7, with ball-pressure temperature per IEC 60695-10-2 at 75 °C and glow-wire flammability per IEC 60695-2-11. The compound is processed at 100 wt% for injection-moulded washing machine base frames and counterweight retainers. Where a softer cold-impact response is required for tub motion stops, it is blended at 40–60 wt% with an impact-modifier-rich LLDPE containing 8–12 wt% ethylene-octene copolymer. Production is on 500–1200 t hydraulic injection moulding machines with multi-point sequential valve gating, melt temperature 200–225 °C, mould temperature 20–35 °C, and cooling time controlled by cavity pressure sensors set to switch over at 35–45 MPa. Terminal outputs include washing machine base frames, dryer motor mounts, dishwasher toe panels, and refrigeration evaporator trays. Pre-drying at 80 °C for 2–3 h is necessary if regrind exceeds 20 wt% because hydrolytic condensation at the silane coupling site can reduce interfacial load transfer and lower weld-line strength. Multi-axial impact data for this specific coupling chemistry is limited; verification per ISO 6603-2 at −20 °C is therefore mandatory before structural appliance parts are released.

    Irrigation valve boxes and drainage catch basins are produced in medium-wall injection moulding from glass-reinforced LLDPE where frost heave and soil loading demand a higher modulus than unfilled polyethylene while retaining impact at low ambient temperature. The governing standards for buried non-pressure enclosures include EN 13598-2 for chamber installation practice, ISO 13267 for buried thermoplastic chambers under traffic loads, and EN 124-5 for gully tops and manhole tops in loading classes up to B125. The compound is used at 100 wt% for load-bearing lids and base sections where stiffness is critical. For large irrigation valve boxes with surface area above 0.5 m², the compound is blended at 30–50 wt% with unfilled LLDPE of melt index 4–6 g/10 min to extend flow during low-pressure structural foam moulding at 150–200 t clamp force. Processing temperatures are 190–215 °C at the nozzle, mould temperature 15–30 °C, and shot weight controlled within ±1.0% using screw position monitoring. The production route is injection moulding with gas counterpressure or short-fibre structural foam; melt temperature must not exceed 230 °C because the chemically coupled glass fibre begins to degrade at higher temperatures, resulting in lower notched Charpy impact at −20 °C per ISO 179-1. Terminal articles include irrigation control valve boxes, catch basin grates, septic tank risers, and trench drain channels. Incoming regrind fractions above 25% are limited by ash content testing per ISO 3451-1 to avoid shifts in creep modulus under continuous wet load.

    Free Quote

    Competitive Clariant PEPR92735G5NAT LLDPE, 5% Glass Fiber, Chemically Coupled prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Clariant PEPR92735G5NAT is a linear low-density polyethylene compound containing 5% by weight chemically coupled glass fiber. The product designation PEPR92735G5NAT separates into a polyethylene base code, a development serial, a 5% glass-fiber mass fraction, and natural coloration. Unlike dry blends of glass fiber and LLDPE, this grade is melt compounded so that the fiber surface is treated with a coupling system, typically an organosilane size or a maleic anhydride-grafted polyolefin interphase, creating a chemical bridge between the inorganic glass surface and the nonpolar polyethylene matrix. The compound is supplied as natural-colored pellets for injection molding and profile extrusion where a moderate increase in tensile and flexural modulus over unfilled LLDPE is required without moving to higher glass loadings that reduce low-temperature ductility and surface quality. Published data for this specific configuration is limited; therefore, selected properties discussed in the following sections are representative ranges for 5% glass-coupled LLDPE grades tested under the cited ISO and ASTM methods rather than a certificate of analysis.

    What distinguishes chemical coupling from conventional glass filler compounding?

    In an uncoupled glass-filled LLDPE compound, the interface between the glass fiber and the polyethylene matrix is weak because the fiber surface is polar and the matrix is nonpolar. Under tensile loading, failure occurs primarily by fiber pull-out and debonding at low stress. A chemically coupled grade such as Clariant PEPR92735G5NAT is treated with an interfacial coupling system that forms covalent or hydrogen-bonded linkages between the glass surface and the matrix. The most common industrial routes involve an amino-silane or methacryloxy-silane size on the fiber and a maleic anhydride-grafted polyethylene in the matrix. During melt compounding, the anhydride groups react with the silane functionality or directly with surface silanols, while the polyethylene backbone co-crystallizes with the LLDPE matrix. This interphase increases the interfacial shear strength from roughly 5–10 MPa for uncoupled systems to values above 15–25 MPa depending on the graft level and fiber sizing chemistry. The result is higher tensile strength, higher flexural modulus, and reduced creep under sustained load. The same improvement in interfacial adhesion reduces failure strain and may alter the fracture mode from ductile pull-out to brittle matrix tearing. Standardized tensile testing according to ISO 527-2 or ASTM D638-14 captures the strength shift, but interfacial shear strength is rarely reported on datasheets and must be evaluated through single-fiber pull-out, microdebond, or transverse tensile tests.

    On production-scale injection molding equipment, the glass fiber component of Clariant PEPR92735G5NAT increases melt viscosity at low shear rate and makes the material more shear thinning than unfilled LLDPE. A general-purpose screw with a compression ratio of 2.0:1 to 2.5:1, a length-to-diameter ratio of at least 20:1, and a wear-resistant check ring is specified for extended runs. Melt temperature is commonly set between 200 °C and 240 °C, with mold temperature from 20 °C to 50 °C. Because glass fiber is abrasive, screw, barrel, and check ring surfaces should be hardened or bimetallic. No special venting is required beyond standard LLDPE practice, but moisture adsorbed on the fiber sizing may form surface splay if the material is stored in high-humidity environments without pre-drying. In such cases, drying at 80 °C for 2–4 h in a desiccant dryer is used to bring surface moisture below 0.05%. Mold-fill pressure is typically 10–25% higher than unfilled LLDPE at the same wall thickness; gates, runners, and vents should be larger in cross-section to compensate for the reduced flow length.

    In injection molding of glass-coupled LLDPE parts, weld lines are a more significant mechanical weakness than in unfilled LLDPE because fibers bridge the melt flow fronts only when the coupling agent survives the rejoining process. Weld-line tensile strength in a 5% glass-filled polyethylene may drop to 50–70% of the unfilled base depending on melt temperature, holding pressure, and the presence of a fiber orientation discontinuity at the knit line. Short shots and surface delamination are observed when the melt temperature is below 190 °C or when the mold temperature is below 15 °C. Raising mold temperature to 30–50 °C and using sequential valve gating can improve weld-line strength but increases cycle time. On hot-runner systems, glass fiber abrasion can accelerate tip wear, so tungsten-carbide or hardened components are specified. Processors also observe that fiber accumulation at the gate can produce anisotropic flow and gate blush; this is reduced by increasing gate diameter above 1.5 mm for thin-wall parts or by using a fan gate with gradual land taper.

    Rheological characterization under ISO 1133-1:2022 shows that the melt mass-flow rate of a glass-filled compound is lower than the base resin. The fiber network increases low-shear viscosity, while high-shear flow remains close to the base LLDPE because of shear thinning. This changes the fill pattern in multi-cavity tools and can shift the pressure-limited process windows. Capillary rheometry at 210 °C and apparent shear rates of 100–1000 s⁻¹ is the most relevant screening method; single-point MFR is insufficient for mold-filling simulation. Moldflow or equivalent simulation requires fiber orientation tensors, which for short-glass compounds depend on screw design, gate location, and fill speed. If no measured fiber orientation data exists, simulation should be validated with short shots and shrinkage measurements under ISO 294-4.

    When 5% glass fiber loading changes shrinkage and post-mold distortion

    Unfilled LLDPE exhibits relatively high and isotropic mold shrinkage, often in the range of 1.5–2.5% depending on wall thickness and melt temperature. The addition of 5% glass fiber lowers total shrinkage and introduces anisotropy because fibers align preferentially in the melt-flow direction. Flow-direction shrinkage in a 5% glass-coupled LLDPE is typically 0.8–1.4%, while transverse shrinkage may remain 1.2–1.8%. The difference between flow and transverse shrinkage creates internal stress gradients that can produce warpage in plaque-shaped parts with nonuniform thickness or unbalanced gating. Mold designers correct for this by positioning gates to produce roughly parallel fiber orientation along the longest dimension and by using uniform wall sections. Shrinkage measurements follow ISO 294-4 or ASTM D955-08. Differential scanning calorimetry under ISO 11357-3 shows that glass fiber can nucleate additional crystallization in LLDPE, but the low fiber weight fraction has a smaller effect on absolute crystallinity than higher glass loadings or talc-filled grades. Because the coefficient of linear thermal expansion of glass is roughly 25 times lower than that of LLDPE, the filled compound exhibits reduced thermal expansion; typical values for a 5% glass-coupled LLDPE fall between 100 µm/m·K and 140 µm/m·K in the flow direction, compared with 150–200 µm/m·K for unfilled LLDPE. These ranges are published for general glass-filled polyethylene families and should be verified for the specific Clariant code.

    The grade is employed in technical articles that require moderate load-bearing capacity, low-temperature impact, and polyolefin chemical resistance. Typical application examples include cable management clips, battery-cell spacers, conveyor guides, agricultural fastener systems, pump wear rings, and light-duty structural brackets. In these uses, unfilled LLDPE may be rejected for excessive creep or deflection, while a 10% or 20% glass-reinforced grade may be unnecessary or may reduce processing ease and surface quality. The 5% glass-coupled product is specified when the functional requirement is a modulus increase of roughly 1.5 to 2.5 times the unfilled base without transitioning to brittle failure at low temperatures below -20 °C. Chemical resistance is consistent with the polyethylene matrix: dilute mineral acids, alkali solutions, and polar organic liquids are typically tolerated at ambient temperature, while aromatic hydrocarbons, chlorinated solvents, and strong oxidizing acids can swell or degrade the compound. No application is accepted without end-user validation under ISO 527-2, ISO 178, ISO 179-1/1eA, and the specific service environment.

    Comparative data against unfilled and higher glass loadings

    Table 1 compares representative property ranges for unfilled LLDPE, 5% glass-coupled LLDPE, and 10% glass-coupled LLDPE. The values are drawn from general industrial data for glass-reinforced polyethylene compounds, not from a certified Clariant lot. Published data for this specific configuration is limited; therefore, the ranges should be used for material-selection screening only.

    Property and standard Unfilled LLDPE 5% glass-coupled LLDPE 10% glass-coupled LLDPE
    Density, ISO 1183-1 0.918–0.930 g/cm³ 0.95–0.97 g/cm³ 0.99–1.03 g/cm³
    Tensile modulus, ISO 527-2 200–400 MPa 500–900 MPa 900–1400 MPa
    Tensile yield strength, ISO 527-2 8–12 MPa 14–20 MPa 18–25 MPa
    Flexural modulus, ISO 178 250–500 MPa 600–1000 MPa 1000–1600 MPa
    Heat deflection temperature, ISO 75-2 Method B 45–60 °C 55–75 °C 70–90 °C
    Flow-direction mold shrinkage, ISO 294-4 1.5–2.5% 0.8–1.4% 0.5–1.0%

    Relative to an uncoupled 5% glass-filled LLDPE, the chemically coupled grade raises tensile yield strength and flexural modulus at the same fiber content, while elongation at break typically decreases because the stronger interface suppresses fiber-matrix sliding and pull-out. The increase in interfacial adhesion also improves creep resistance and fatigue performance under cyclic loading, although standardized fatigue data for this specific product is not published. Against a 10% glass-coupled grade, the 5% product retains better surface appearance, lower density, and lower melt viscosity, but it gives up stiffness and heat deflection. Selection between these grades should be based on multi-point mechanical testing under ISO 527-2 and ISO 178 using the actual wall thickness and flow length of the part.

    Compared with 5% glass-coupled polypropylene, the LLDPE grade has lower tensile strength and flexural modulus but better impact resistance below -20 °C, lower processing temperature, and higher environmental stress-cracking resistance in polar fluids. Compared with 5% glass-coupled HDPE, the LLDPE matrix has lower density and lower stiffness, but the linear-chain architecture and comonomer distribution provide greater toughness and flexibility. These differences prevent direct part substitution without revalidation of the load case according to ISO 527-2 and ISO 75-2.

    At elevated humidity the pre-drying requirement changes from zero to 80 °C

    Polyethylene is not hygroscopic, and unfilled LLDPE is routinely processed without drying in dry environments. The glass-fiber sizing in Clariant PEPR92735G5NAT can retain surface moisture, particularly when bags are opened in relative humidity above 60% or when cold material is moved into a warm production area. Under these conditions, the recommended correction is 2–4 h at 80 °C in a desiccant or hot-air dryer with adequate airflow. The target is not matrix moisture but the reduction of surface water on the sizing to below roughly 0.05% by weight, thereby preventing splay, surface roughness, and weak weld lines. No specific drying schedule is published for this particular Clariant code; the values stated reflect standard handling practice for glass-reinforced polyethylene compounds.

    Operational boundaries include continuous service under load above 60–70 °C, where creep resistance of the LLDPE matrix falls rapidly and the glass fiber cannot compensate for matrix softening. The compound should not be used in continuous contact with strong oxidizing acids such as fuming nitric acid or with chlorinated solvents at elevated temperature, because these agents attack the polyethylene phase and can degrade the coupling layer over time. Natural-color material without additional stabilizers is not intended for prolonged outdoor exposure; UV stabilization must be specified with the supplier if outdoor weathering is required.

    Regulatory data for this specific grade should be obtained from the supplier. General compliance with RoHS Directive 2011/65/EU and REACH Regulation EC 1907/2006 may be available for the natural grade, but food-contact status under EU Regulation 10/2011 or FDA 21 CFR 177.1520 is not automatically assigned to a glass-reinforced compound containing coupling agents. Electrical enclosure applications require end-product flammability testing, because glass-filled LLDPE typically falls into UL 94 HB classification and is not self-extinguishing without flame-retardant modification.

    Top