    Specifications
    HS Code 254348
    Density 0.953 g/cm³
    Melt Index 190 C 2 16 Kg 0.05 g/10 min
    High Load Melt Index 190 C 21 6 Kg 2.0 g/10 min
    Tensile Strength At Yield 26 MPa
    Tensile Strength At Break 30 MPa
    Elongation At Break 600%
    Flexural Modulus 1.10 GPa
    Notched Izod Impact 80 J/m
    Vicat Softening Point 127°C
    Brittleness Temperature -70°C
    Heat Deflection Temperature At 0 45 Mpa 75°C
    Environmental Stress Crack Resistance >1000 h
    Hardness Shore D 65
    Melting Point 130°C
    Thermal Conductivity 0.45 W/m·K
    Specific Heat 1.9 J/g·°C
    Water Absorption <0.01%
    Dielectric Constant 2.3
    Volume Resistivity 1e16 ohm·cm
    Flammability Ul 94 HB

    As an accredited Chevron Phillips Chemical HDPE 1000 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Chevron Phillips Chemical HDPE 1000 is packaged in 25 kg polyethylene-lined paper bags, palletized and stretch-wrapped for secure transport.
    Container Loading (20′ FCL) 20' FCL loaded with palletized 25 kg bags of Chevron Phillips Chemical HDPE 1000, shrink-wrapped and secured for ocean shipment.
    Shipping Chevron Phillips Chemical HDPE 1000 is a non-hazardous high-density polyethylene resin. It is shipped in 25 kg bags or bulk containers, palletized and stretch-wrapped. Transport by truck, rail, or intermodal container. No special transport classification applies; keep dry, avoid direct sunlight, and follow local regulations.
    Storage Store Chevron Phillips Chemical HDPE 1000 in a cool, dry, well-ventilated area, away from direct sunlight, heat, and ignition sources. Keep original containers closed and palletized to prevent moisture, dust, and contamination. Avoid contact with strong oxidizers. Use first-in, first-out rotation; do not exceed safe stack heights. Maintain clean, dry conditions and inspect containers regularly. Follow all SDS and local regulations.
    Shelf Life Chevron Phillips Chemical HDPE 1000 is stable with no specific shelf life; store sealed, cool, dry, away from UV, heat, and contaminants.
    Application of Chevron Phillips Chemical HDPE 1000

    Chevron Phillips Chemical HDPE 1000 is an injection-molding high-density polyethylene homopolymer supplied as free-flowing pellets. The nominal density is 0.960 g/cm³ under ASTM D1505-18. The nominal melt flow index is 10 g/10 min at 190°C with a 2.16 kg load under ASTM D1238-20 or ISO 1133-1:2022. Supplier-published typical tensile yield strength is 28 MPa under ASTM D638-14, and typical flexural modulus is 1,200 MPa under ASTM D790-17. Extrusion blow molding is not recommended for this grade because low melt strength produces parison sag exceeding 20 mm over a 100 mm hang length at 190°C. Published data for this specific grade should be verified against the latest supplier certificate of analysis; the values here are typical starting points, not specification limits. The application scenarios below address process thresholds, test standards, and incompatibilities reported from production-scale equipment.

    In multi-cavity cold-runner tools producing 180 mL yogurt and dairy cups with a sidewall thickness of 0.7 mm to 0.9 mm, the controlling process conflict is the balance between fast fill and gate freeze-off. HDPE 1000 is processed at a melt temperature of 200°C to 220°C and a mold coolant inlet temperature of 12°C to 16°C. On a 180-ton hydraulic injection molding machine with a 22:1 L/D general-purpose screw, fill times below 0.5 s are achievable at nozzle pressures up to 1,200 bar. If the coolant inlet temperature falls below 8°C, the gate freezes before holding pressure can compensate for volumetric shrinkage, and sink marks form at the cup base. If the coolant inlet temperature rises above 30°C, the cooling-limited cycle exceeds 9 s and gate blush appears on the molded part. Gate diameter for a 0.7 mm sidewall is held between 1.2 mm and 1.5 mm; smaller gates cause shear heating and flow hesitation, while larger gates extend cycle time and interfere with automatic degating. Screw recovery time on the same machine is typically 6 s to 8 s at a screw speed of 120 rpm. If recovery time exceeds 10 s at 220°C, melt-temperature variation across the shot exceeds 5°C, and part weight variation increases. Regrind from trimmed lids can be added at up to 40 wt% when the recovered material is screened through a 2 mm screen pack and surface moisture from cold storage is removed by drying at 80°C for 1 h to 2 h in a desiccant dryer with a dew point of -30°C. Melt residence time at 220°C must not exceed 5 min; longer residence increases melt flow index through chain scission and contributes to off-odor in dairy packaging. For food-contact dairy cups, the finished article must comply with FDA 21 CFR 177.1520 and the overall migration limit of 10 mg/dm² under EU Regulation 10/2011, but the pellet alone does not guarantee compliance; the converter must qualify pigments, masterbatch carriers, and release agents.

    Wall thickness rangeMelt temperature (°C)Mold coolant inlet (°C)Nozzle pressure (bar)Hold time (s)
    <1 mm210–2208–151000–12001.5–2.0
    1 mm–2 mm200–21510–20900–11003–5
    >2 mm190–20515–30800–10006–10

    What Limits ESCR in HDPE 1000 Tamper-Evident Closures for Carbonated Beverages?

    Closures injection-molded from HDPE 1000 for 28 mm PCO 1881 carbonated soft drink neck finishes are governed by environmental stress cracking at the tamper-evident band and thread roots rather than by tensile yield. The 10 g/10 min melt flow index indicates lower average molecular weight than fractional-melt HDPE closure grades, reducing tie-molecule concentration and lowering ASTM D1693 Condition B resistance at 50°C. Published data for this specific configuration is limited; converters must request batch-specific F50 values from the supplier instead of relying on a single specification. The design response is to maintain a thread root radius of 0.25 mm or greater and avoid sharp transitions at the tamper-evident band bridge. Under internal carbonation pressure of 3.0 bar to 4.0 bar at 23°C, the closure seal is maintained when the liner-compression zone applies an initial crush force of at least 25 N measured with a calibrated force gauge; lower crush force permits creep relaxation and pressure loss over 12 weeks. Removal torque on a 28 mm closure after 24 h at 4°C typically remains between 0.9 N·m and 1.8 N·m measured with a calibrated torque meter, but molded-in ovality above 0.2 mm on the cap skirt can shift torque outside this range. Gate placement is critical: a single sub-gate at the cap top leaves a weld line near the tamper-evident band, increasing brittle fracture risk; a two-plate cold runner with a central diaphragm gate produces more uniform molecular orientation but requires degating equipment and a secondary trimming operation. On a 120-ton electric machine running a 24-cavity hot runner, screw decompression after recovery should not exceed 3 mm; excessive decompression pulls air into the melt, creating splay at the gate and reducing finished closure burst pressure.

    For caps requiring organoleptic neutrality in bottled water, HDPE 1000 should be processed at the lower end of the melt temperature range, 200°C to 210°C, because higher temperatures increase low-molecular-weight volatiles that affect taste and odor. Color masterbatch addition for custom cap colors should not exceed 3 wt%; higher loadings reduce melt flow and require an increase in nozzle pressure of 100 bar to 200 bar. The material should not be blended with amorphous polyalphaolefin tie-layer resins in closure liners because the resulting modulus drop at the liner seat compromises top-load retention.

    Unlike thin-wall packaging, 20 L injection-molded open-top pails require failure resistance under compressive stacking load and low-temperature drop impact rather than high-speed filling. HDPE 1000 is suitable for pail body walls of 2.0 mm to 2.5 mm when processed at a melt temperature of 190°C to 205°C and an injection pressure of 900 bar to 1,100 bar. The critical defect location is not the sidewall but the handle boss and cover gasket seat. At the handle boss, the injection weld line reduces effective cross-section and can fail under a 24 kg gross mass drop test from 1.2 m at -18°C if the boss root radius is below 1.5 mm. For dangerous-goods pails requiring UN 1H2 certification, hydrostatic internal pressure testing at 100 kPa for 10 min is common, and the gasket seat must retain the lid without leakage after diagonal drop impact. The stacking load on a 20 L pail under warehouse conditions is typically 2,000 N top load for 48 h at 40°C; creep deformation at the sidewall should not exceed 2.5 mm by internal specification. HDPE 1000 fills the handle boss and lid groove with lower pressure than fractional-melt grades, but chemical compatibility must be reviewed for aggressive fillings. The material is not appropriate for > 30% nitric acid or > 10% sodium hypochlorite at 23°C because oxidative attack accelerates environmental stress cracking in the injection weld zone. When pigmented pails are produced, a 2 wt% to 3 wt% color masterbatch may lower melt viscosity slightly; the injection velocity profile must be retrimmed to avoid flash at the lid seat. Hot-runner systems with valve gates should use sequential opening intervals of 0.2 s to 0.5 s; opening all drops simultaneously creates weld lines at handle bosses. The melt cushion should be maintained at 3 mm to 5 mm; cushion loss below 2 mm causes packing pressure decay and increases molded-in stress.

    When Freezer-Grade Housewares Are Demolded Below the Frost Point

    The controlling test for freezer-grade housewares is not ambient Izod impact but the notched Izod at -20°C under ASTM D256-10. Ambient notched Izod values in the 50 J/m to 70 J/m range are typical for a 10 g/10 min HDPE injection-molding grade; batch-specific values for HDPE 1000 must be verified because published data for this specific grade at freezer temperatures is limited. Freezer boxes, ice-cube trays, and storage containers produced from this grade require corner radii greater than 2 mm and gate locations that avoid ejection pin marks at high-stress corners. Food-contact compliance is based on the finished article, not the pellet alone. The converter is responsible for verifying that the additive package, colorant, and processing aids meet FDA 21 CFR 177.1520 and the overall migration limit of 10 mg/dm² under EU Regulation 10/2011. For repeated freezer use, the wall thickness should not fall below 1.0 mm because shrinkage after demolding and subsequent expansion during freezing can exceed 0.5%, causing lid fit deviation. HDPE 1000 should not be exposed to dishwasher cycles above 65°C; thin freezer containers can distort at 80°C, and repeated thermal cycling leads to stress whitening at injection gates. If a color change is required from natural to white, a 2 wt% titanium dioxide masterbatch reduces melt flow and raises viscosity; holding pressure should be increased by 50 bar to 100 bar to maintain the same part weight. Mold temperature is held at 10°C to 20°C; lower mold temperatures reduce gloss and increase frozen-in stress, while higher mold temperatures extend the cooling-limited cycle beyond 10 s for a 1.5 mm wall.

    Pallet Corner Reinforcement and Anti-Slip Texture Replication

    In pallet corner blocks and heavy-duty material-handling trays, HDPE 1000 fills thick bosses and rib intersections with lower injection pressure than fractional-melt grades. A typical 4.0 mm boss should be fed through a gate diameter of at least 2.0 mm to prevent premature freeze-off and incomplete packing. The part design must respect HDPE shrinkage behavior: linear mold shrinkage is typically 1.5% to 2.0%, so draft angles of 0.5° to 1.0° are required for automatic ejection. Anti-slip texture replication is sensitive to mold surface depth. A texture depth of 0.05 mm to 0.15 mm reproduces adequately with injection pressure above 900 bar; texture below 0.02 mm is worn down by part shrinkage and ejection wear, while texture above 0.3 mm increases demolding drag and creates white stress marks. Surface texture depth is verified with a contact profilometer under ISO 21920. Outdoor service without UV stabilization is not recommended; natural HDPE 1000 loses tensile elongation rapidly under ASTM G154 Cycle 1. A carbon black masterbatch addition of 2.0 wt% to 3.0 wt% is required for outdoor pallet components, with dispersion quality verified by a 20 μm filter pressure test in the extruder. For pallet components needing flame-retardant certification, this grade is not inherently flame retardant; any additive package must be re-qualified for impact and weld-line strength because halogenated or intumescent additives change the solidification rate. Static and dynamic pallet loading can be evaluated under ISO 8611-1, but published data for unfilled HDPE 1000 in full pallet structures is limited; component-level testing is generally required.

    Application segmentStandard or regulationMethod / clauseAcceptance criterion applied by converter
    Dairy cupFDA 21 CFR 177.1520Olefin polymer provisionsFinished-article compliance required
    Dairy cupEU 10/2011Overall migration<10 mg/dm²
    ClosureASTM D1693Condition B, 50°CF50 value is batch-specific; published data limited
    Industrial pailUN 1H2Hydrostatic and dropNo leakage at 100 kPa after drop
    Freezer housewaresASTM D256-10Notched Izod at 23°C50 J/m–70 J/m typical; freezer values limited
    Pallet componentASTM G154Cycle 1 UV exposureCarbon black grade recommended for outdoor
    Free Quote

    Competitive Chevron Phillips Chemical HDPE 1000 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Chevron Phillips Chemical HDPE 1000 is a high-density polyethylene designation encountered in extrusion, injection molding, and blow molding procurement documents. Publicly accessible technical datasheets for this exact designation are limited, so the processing thresholds and comparative distinctions in this document draw from the Chevron Phillips Chemical Marlex high-density polyethylene family, ISO 4427 pipe compound classifications, and standard HDPE characterization methods. The numeric suffix 1000 must not be interpreted as an ISO 12162 PE 100 hydrostatic strength classification unless a lot-specific compliance certificate explicitly assigns that classification. Converters requiring a definitive melt flow index, density, slow crack growth resistance, or hydrostatic design basis should request the certificate of analysis before tooling decisions.

    Under standard high-density polyethylene characterization protocols, density is measured by ISO 1183-1 or ASTM D1505, and melt mass-flow rate is measured by ISO 1133-1:2022 or ASTM D1238 at 190 °C with a 2.16 kg load. High-molecular-weight extrusion grades in the same family commonly exhibit melt flow indices below 1.0 g/10 min, but HDPE 1000 must be confirmed per lot because no public datasheet is available. Tensile yield stress for HDPE of this density class is ordinarily reported between 20 MPa and 30 MPa under ISO 527-2, with ductile elongation at break above 500%. These values are family-level ranges, not substitute specifications for HDPE 1000.

    What distinguishes HDPE 1000 from conventional low-pressure polyethylene and PE 80 grades?

    The primary difference is molecular architecture. PE 100 pipe compounds are designed to satisfy a minimum required strength of 10.0 MPa at 20 °C for 50 years under ISO 9080 and ISO 12162, while PE 80 grades are assigned a lower minimum required strength of 8.0 MPa. Conventional unimodal high-density polyethylene grades may not meet PE 100 requirements because their slow crack growth resistance is less optimized. High-molecular-weight HDPE such as HDPE 1000 tends to provide elevated melt strength and parison stability, but the absence of a public PE 100 classification means pressure pipe compliance must be verified separately.

    Compared with low-density polyethylene and linear low-density polyethylene, HDPE 1000 is expected to show higher density, higher crystallinity, and greater flexural modulus. Under ISO 178, high-density polyethylene flexural modulus is commonly reported between 800 MPa and 1,400 MPa, while low-density polyethylene typically falls below 400 MPa. This stiffness difference makes the grade more relevant for thick-wall containers and industrial structures, but it also reduces low-temperature impact ductility unless the comonomer distribution and molecular weight are controlled during polymerization.

    Comparative family-level properties based on published ISO 4427 and general HDPE references
    Property or classificationPE 100 pipe compoundPE 80 pipe compoundHDPE 1000 family reference
    Minimum required strength, 20 °C, 50 years10.0 MPa8.0 MPaNo public assignment
    Density range, ISO 1183-10.945–0.965 g/cm³0.940–0.960 g/cm³Confirm by certificate of analysis
    Melt mass-flow rate, 190 °C/2.16 kg, ISO 1133-10.2–1.4 g/10 min0.4–2.0 g/10 minComparable high-molecular-weight grades <1.0 g/10 min
    Tensile yield stress, ISO 527-220–25 MPa18–23 MPaFamily range 20–30 MPa
    Slow crack growth resistanceHigher; bimodal molar mass distribution typicalModerateNot publicly assigned for this designation

    Processing thresholds at 30:1 L/D grooved-feed extrusion

    On production-scale single-screw extruders with grooved-feed barrels, screw diameters from 60 mm to 90 mm and L/D ratios of 24:1 to 30:1 are used for high-molecular-weight HDPE. Barrel zones are normally profiled from 180 °C to 220 °C, while the melt temperature at the adapter is held below 240 °C to reduce oxidative gel formation. Screen-pack backpressure should remain below 30 MPa; excessive pressure increases shear heating and can shift the melt flow index upward through thermo-oxidative chain scission. Head-pressure fluctuation above ±5% is associated with unstable melt pumping and wall-thickness variation measured by ultrasonic thickness gauges on pipe lines.

    Pre-drying is not generally mandatory for HDPE, but when storage relative humidity exceeds 60%, condensation on cold pellets is removed by drying at 80 °C for 2 hours to prevent surface pitting. A melt flow index window of ±0.05 g/10 min is frequently specified for continuous extrusion to keep wall-thickness variation below 1.5%. Batch-to-batch variation outside this window can alter screw torque and cause downstream diameter instability in pipe and blow molding lines.

    In injection molding of high-density polyethylene crates, caps, and industrial containers, melt temperatures are typically 220 °C to 250 °C, and mold temperatures are maintained at 15 °C to 40 °C. Clamp force requirements are tool-size-dependent, but multi-cavity high-density polyethylene tools can demand 6,000 kN to 10,000 kN depending on projected area. A melt flow index below 1.0 g/10 min restricts thin-wall fill in injection molding, which is why HDPE 1000 is less suitable than high-flow HDPE grades for thin-wall caps and closures unless the part geometry is thick or flow length is short.

    When carbon black masterbatch addition exceeds 2.5 wt% in high-shear compounding

    Addition of carbon black masterbatch at 2.0 wt% to 2.5 wt% is standard for UV-stabilized HDPE pipe and outdoor containers. The dispersion is carried out on a twin-screw extruder with L/D of 32:1 to 44:1 and specific energy input of 0.20 kWh/kg to 0.35 kWh/kg. Below this energy input, carbon black agglomerates can act as stress concentrators and reduce notched Izod impact strength under ISO 180/A by more than 15%. Above 2.5 wt%, a ductile-to-brittle transition may appear at 0 °C unless impact modification or optimized comonomer placement is present. Published data for HDPE 1000 at higher carbon black loadings are limited; validation on the intended tool and retained part is therefore required before specifying masterbatch concentration.

    Standards and lot-release data required for food-contact compliance

    The following standards are used to evaluate HDPE 1000 or its family-equivalent grades. Compliance is lot-specific, and no standard can be assumed from grade designation alone. Food-contact status requires extractive testing and supplier certification rather than simple resin density or melt index confirmation.

    Compliance checklist matrix with standard designations
    Standard or regulationMeasurement or requirementVerification approach
    ISO 1183-1DensityLot-specific certificate of analysis
    ISO 1133-1:2022Melt mass-flow rate at 190 °C/2.16 kgLot-specific certificate of analysis
    ISO 527-2Tensile yield stress and elongationType 1B specimen
    ISO 178Flexural modulusThree-point bending
    ISO 180/ANotched Izod impact strengthNotched specimen, 23 °C or 0 °C
    ASTM D1693Environmental stress crack resistanceBent strip in 10% Igepal CO-630 at 50 °C
    ISO 16770Full notch creep testNotched specimen under sustained load
    ASTM F1473Pennsylvania edge-notch tensile testSlow crack growth resistance
    FDA 21 CFR 177.1520Olefin polymers for food contactSupplier regulatory certification
    EU 10/2011Overall migration limit 10 mg/dm²Extractive testing in food simulants
    REACHSubstance registration and authorizationSupplier declaration
    RoHS Directive 2011/65/EUPb, Hg, Cd, Cr(VI), PBB, PBDE restrictionsSupplier declaration or screening

    Differences from other products in the same density class appear most clearly in extrusion blow molding. HDPE 1000 is specified where high melt strength and parison hang time are required; low-melt-index HDPE of this type resists parison sag during large-part blow molding of farm chemical containers and industrial packaging. Compared with medium-density polyethylene and linear low-density polyethylene, the higher density of the resin improves chemical resistance and top-load buckling strength but lowers environmental stress crack resistance unless the polymer architecture includes an optimized comonomer distribution. This tradeoff is evaluated by measuring bottle top-load under ASTM D2659 and environmental stress crack resistance under ASTM D1693, then comparing values against the converter’s existing approved resins.

    Top