    Specifications
    HS Code 516486
    Productname Chesterton 850 Premium Sealing Tape
    Brand Chesterton
    Producttype PTFE thread sealing tape
    Material Virgin PTFE
    Color White
    Temperaturerange -450°F to 500°F (-268°C to 260°C)
    Pressurerating Up to 10,000 psi (690 bar)
    Density 1.3 g/cm³
    Thickness 0.0035 in (0.09 mm)
    Width 1/2 in (12.7 mm)
    Length 260 in (6.6 m) per standard roll
    Certifications MIL-T-27730A, NSF/ANSI 61
    Chemicalresistance Resistant to most chemicals, acids, alkalis, solvents, and gases
    Application Sealing threaded pipe joints for water, steam, chemicals, gases, and hydraulic systems
    Shelflife Indefinite

    As an accredited Chesterton 850 Premium Sealing Tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Chesterton 850 Premium Sealing Tape is packaged in 1/2-inch by 260-inch rolls, 12 rolls per box.
    Container Loading (20′ FCL) Chesterton 850 Premium Sealing Tape is loaded into a 20-foot FCL, palletized, shrink-wrapped, and secured under dry conditions for transport.
    Shipping Chesterton 850 Premium Sealing Tape is not classified as dangerous goods for transport. It has no UN number, hazard class, or packing group. Ship as general, non-hazardous cargo under normal freight conditions. No special labels, placards, or emergency response information required.
    Storage Store in a cool, dry, well-ventilated area away from direct sunlight, heat, and ignition sources. Keep containers tightly closed, upright, and clearly labeled. Protect from moisture, dust, and physical damage. Separate from strong oxidizers and incompatible materials. Avoid excessive temperatures. Maintain good housekeeping and follow local regulations and the manufacturer’s safety data sheet. Use original packaging. Store at ambient temperature.
    Shelf Life Shelf life is indefinite when stored in original packaging in a cool, dry area, away from direct sunlight and extreme temperatures.
    Application of Chesterton 850 Premium Sealing Tape

    On chlor-alkali auxiliary headers where saturated brine at 82 °C and 32 wt% sodium hydroxide circulate through Schedule 80 CPVC and titanium threaded connections, Chesterton 850 Premium Sealing Tape is applied as a skived PTFE thread sealant on ASME B1.20.1 tapered threads up to DN 50. The installation sequence begins with a solvent wipe of the male thread crests and roots, followed by two to three wraps on DN 25 and smaller joints and three to four wraps on DN 32–DN 50 joints, leaving the first thread uncovered to prevent tape fragments from entering the pump suction strainer. The tape is pressed into the thread roots with a hand roller, and the joint is made up to hand-tight plus one-half turn; the diametral interference of the tapered thread planes produces a leak-tight seal at 6.9 bar hydrostatic test pressure. Resin control is referenced to ASTM D3308, and indirect food-contact suitability for perfluorocarbon resins is evaluated under FDA 21 CFR 177.1550. Parallel straight threads under ISO 7-1 are excluded from this sealing method because the tape cannot maintain radial load without taper. The result is a brine/caustic line that after 72 h static pressure decay testing at 1.5 times operating pressure shows no seepage at the thread root.

    What Limits Breakaway Torque After 60 Days in 98% Sulphuric Acid Storage Lines?

    Concentrated sulphuric acid lines present a thread-sealing problem that is controlled by the dehydrating strength of the acid rather than by direct degradation of the tape. On carbon steel 98% sulphuric acid storage and transfer lines, threaded instrument isolation valves are wrapped with Chesterton 850 Premium Sealing Tape before assembly into Schedule 80 carbon steel sockets. Sulphuric acid at 35 °C–45 °C aggressively attacks most hydrocarbon-based thread compounds but does not chemically degrade PTFE in this service. The limiting variable is not attack on the tape but moisture ingress at the male thread root that promotes iron sulphate accumulation and raises breakaway torque during maintenance. A three-wrap application on DN 15 and DN 20 instrument nipples produces a compressed tape layer of approximately 0.075 mm–0.10 mm after torqueing, sufficient to fill the helical clearance without reducing the wrench flats’ contact area. Joints are made up with a calibrated torque wrench to 68 N·m for DN 20 carbon steel-threaded nipples and are then subjected to a 24 h hold at 1.5 times the storage tank nitrogen blanket pressure of 0.35 bar. The terminal assembly is a sulphuric acid tank nozzle connection with a vapor-phase corrosion allowance of 3 mm. Re-taping over corroded threads is not permitted because pitting depths greater than 0.25 mm reduce sealing reliability. The assembly boundary is anchored to ASME B31.3 process piping requirements and NACE TM0169 corrosion monitoring criteria.

    For pharmaceutical water-for-injection distribution loops constructed from 316L stainless steel with 0.6 µm electropolished surfaces to ASME BPE, Chesterton 850 Premium Sealing Tape seals threaded instrument tees and sampling valve bodies where orbital welding is not practical. The installation procedure follows a two-wrap maximum on DN 10–DN 20 tapered stainless steel threads because excess tape thickness increases tensile stress on the female thin-wall tee and generates particulate shedding into the low-velocity dead leg. After wrapping, the male thread is cleaned with a lint-free wipe moistened with 70% isopropanol, and the joint is assembled with a gap-free thread engagement of at least six full threads. The tape resin is evaluated under FDA 21 CFR 177.1550 for perfluorocarbon resins and USP <661> for plastic materials of construction. Leachables from the PTFE are below the total organic carbon action limit of 500 ppb and the conductivity action limit of 1.3 µS/cm at 25 °C in cold water-for-injection. The finished connection is a sanitizable sampling drop with no visible thread crevice corrosion after 50 clean-in-place cycles at 80 °C. The tape is not used on orbital-welded or hygienic clamp connections because the crevice itself can retain cleaning solution and the tape may prevent full metal-to-metal contact in clamp geometry.

    Operating boundaryControlling standard or methodLimiting value
    PTFE thread-sealing tape resin propertiesASTM D3308Elongation minimum 25%
    Oxygen service wetted-surface contaminationCGA G-4.1Hydrocarbon residue below 5 mg/m²
    Water-for-injection leachablesUSP <661>, USP <643>, USP <645>TOC below 500 ppb; conductivity below 1.3 µS/cm at 25 °C
    Fire sprinkler hydrostatic testNFPA 1313.8 bar or 1.5 times working pressure
    Threaded joint leak-path fillASME B1.20.10.075 mm–0.10 mm compressed tape layer

    Oxygen-enriched Thread Sealant Heat Release and Autogenous Ignition Boundaries

    In oxygen piping and valve assemblies for 93% oxygen enrichment at 15 bar, selection of Chesterton 850 Premium Sealing Tape is conditional on an oxygen cleaning protocol. PTFE is not flammable in the manner of hydrocarbon-based pastes, but heating under adiabatic compression can release sufficient energy to ignite the tape if metallic particle contamination or hydrocarbon films are present. The tape is stored in sealed polyethylene bags and handled with nitrile gloves, then applied at two wraps on DN 8–DN 12 instrument tubing compression adapters cleaned in accordance with CGA G-4.1. Assembly is completed using an oxygen-safe assembly lubricant only on the nut bearing surfaces, never on the threads themselves. The construction is evaluated for oxygen compatibility under ASTM G63 on a representative coupon, with the acceptance window set below the maximum oxygen service temperature of 60 °C for the valve body. The cleaned assembly is a bagged oxygen injection skid for ozone generation where the thread sealant does not introduce hydrocarbon contamination above 5 mg/m². The exclusion condition applies to liquid oxygen siphons and quick-disconnect couplers where high-velocity particle impact can raise the local heat release rate beyond the test envelope.

    Wet-pipe steel branch lines require a sealant that does not shred into the sprinkler orifice. On galvanized steel threaded drops to residential sprinklers, Chesterton 850 Premium Sealing Tape is applied over the male thread after the first two threads, with three wraps on DN 25 threads and four wraps on DN 32–DN 40 branch outlets. The installation torque for DN 25 galvanized fittings is limited to 40 N·m–55 N·m, and the joint is not backed off after make-up because partial reverse rotation creates a leak path through the compacted tape. NFPA 13 requires a hydrostatic test at 13.8 bar or 1.5 times the system working pressure, whichever is higher; the taped joint remains leak-free during the 2 h test. The installed branch line passes the NFPA 13 visual installation inspection and initial flow test without thread leaks. The limiting condition is that the tape is not used on dry pipe or preaction systems with compressed air residual oil carryover above 1 mg/m³ unless the threads are solvent-cleaned first, because oil-laden air can convert the PTFE surface into a particle-attracting film that increases the chance of clogging sprinkler discharge orifices.

    When Sodium Hypochlorite Injects into Filtered Effluent at pH 6.5–7.5

    In wastewater disinfection skids where 12.5% sodium hypochlorite is metered into filtered effluent, the injection quill and flow cell bodies are threaded into PVC and CPVC socket fittings. Chesterton 850 Premium Sealing Tape is used because it does not react with hypochlorous acid at pH 6.5–7.5, whereas many linseed-oil-based joint compounds saponify and soften PVC socket walls. The tape is applied in three wraps on DN 15 and DN 20 threads and compressed by one full turn beyond hand-tight; the resulting cold flow of the PTFE fills the spiral leak path without inducing a hoop stress above 6.9 MPa in Schedule 80 CPVC. Torque wrench calibration is maintained on a 90-day interval to control batch-to-batch variability in compressed tape thickness. After assembly, the joints are pressure-tested at 10.3 bar for 15 min and then flushed with 20 bed volumes of filtered water to remove tape debris. The delivered skid-mounted sodium hypochlorite dosing line maintains microbiological reduction below 100 CFU/100 mL in the contact chamber effluent. The tape is not applied to threads already contaminated with silicone release agents or pipe dope; residue from these materials prevents adequate PTFE cold flow and lowers the joint’s pressure retention below the test threshold.

    Avoiding Galling on Titanium Instrument Nipples in Marine Cooling Loops

    Seawater cooling loops fitted with titanium instrument nipples demand a thread sealant that reduces galling and separates titanium from 90/10 copper-nickel female sockets. Chesterton 850 Premium Sealing Tape is used on DN 8–DN 12 nipples at a two-wrap schedule because thicker tape layers can cause excessive radial force and initiate stress corrosion cracking at the copper-nickel socket root. Published torque-to-breakaway data for this specific tape on titanium-to-copper-nickel threads is limited; the 25 N·m value for DN 12 is obtained from fitting manufacturer assembly tables and adjusted downward from the dry metal torque to account for the lower coefficient of friction of PTFE. The joint is torqued to 25 N·m for DN 12, and the exposed first thread is rinsed with demineralized water to remove copper ion residue before the loop is filled with filtered seawater at 35 °C. The tape barrier lowers the mixed-potential corrosion current at the thread interface, and a 90-day inspection interval monitors for crevice corrosion underneath the tape edge. The instrumentation tap remains serviceable through a 6-month ballast water treatment campaign without loss of thread integrity. The boundary condition is that the tape is not a substitute for sacrificial anode protection, nor is it rated for ferrous fittings in stagnant seawater where microbiologically influenced corrosion can penetrate the thread root.

    Free Quote

    Competitive Chesterton 850 Premium Sealing Tape prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Chesterton 850 Premium Sealing Tape is supplied as a continuous, self-adhesive expanded polytetrafluoroethylene tape manufactured for form-in-place gasket service on flanged joints, pump casings, gearboxes, and irregular machined closures. The model designation 850 distinguishes the product from filled PTFE sheet and thread-sealing tape. Roll widths commonly stocked range from 3.2 mm to 25.4 mm; standard thicknesses are 1.0 mm, 1.5 mm, 2.0 mm, and 3.2 mm. The base material is expanded PTFE without glass, silica, carbon, or elastomeric binder. The single-face pressure-sensitive adhesive is a positioning aid only and is not considered part of the sealing barrier.

    Manufacturer-published operational limits place the tape in continuous service from -268 °C to 260 °C, with pressure capability from full vacuum to 83 bar. The upper temperature is governed by PTFE chain scission and the onset of fluorine-containing decomposition products, not by adhesive softening. The pressure rating is conditional on flange stiffness, bolt spacing, flange surface finish, and applied seating stress. Published data for this specific configuration is limited for cyclic service above 204 °C or for bolt stress below 7 MPa on steel flanges. The pressure capability is not an intrinsic property of the tape alone; it is a system property requiring adequate gasket width, rigid flange geometry, and correct bolt preload. A gasket width of at least 10 mm is assumed for the 83 bar rating, and narrow tapes or flexible flanges reduce the allowable pressure.

    What distinguishes expanded PTFE tape from skived PTFE and filled sheet gaskets?

    The dominant variable is compressibility under the seating stress available from standard bolting. Expanded PTFE contains a fibrillated node-and-fiber structure that collapses into flange roughness features at moderate load, whereas skived PTFE sheet is dense and non-porous. A rigid skived PTFE gasket can require seating stress above 25 MPa to seal a wavy flange surface, while expanded PTFE tape of this class typically seals at 7 MPa to 14 MPa. Filled PTFE sheet products improve creep resistance by adding glass, carbon, or mineral reinforcement, but the discrete filler particles can impinge on polished metal and initiate surface scoring. Chesterton 850 is manufactured without filler, so the process-contact surface contributes no metallic ions or leachable reinforcement residues.

    The following comparative data are product-class ranges drawn from published gasket literature and should be verified against the current Chesterton 850 technical datasheet before design calculations:

    Material systemCompressibility (ASTM F36)Recovery (ASTM F36)Continuous temperature ceilingTypical seating stress
    Expanded PTFE tape35–60%8–15%260 °C7–14 MPa
    Skived PTFE sheet1–3%0–1%260 °C25–40 MPa
    Glass-filled PTFE sheet5–12%2–5%260 °C15–25 MPa
    Flexible graphite sheet30–40%10–18%450 °C10–18 MPa

    Flexible graphite offers a higher thermal ceiling, but its electrically conductive nature can promote galvanic corrosion on stainless steel flanges in moist environments. Expanded PTFE is non-conductive and avoids that galvanic couple. The trade-off is higher creep: PTFE cold flow under sustained load requires re-torque, while graphite retains seating stress more effectively. The adhesive layer also differentiates 850 from non-adhesive expanded PTFE tapes. Non-adhesive tapes require external alignment fixtures and can shift during closure; the adhesive-backed product remains in position without clamping. The adhesive does not contribute to sealing, and the joint should not be designed on the assumption that the adhesive will fill a flaw.

    Leakage-Path Formation on Damaged Flange Faces Under Thermal Cycling

    Field service on production-scale flanged equipment shows that leakage is often preceded by surface irregularities created by erosion, weld spatter, or mechanical damage. Chesterton 850 is applied where flange out-of-flatness is as high as 0.5 mm and where a rigid sheet gasket cannot conform. The expanded structure compresses at low stress and flows into serrations of 3.2 µm Ra without requiring plastic deformation of the metal. On a DN 600 reactor body flange with a measured out-of-flatness of 0.3 mm, a single 2.0 mm layer installed at 10 MPa has maintained a leak-tight seal over 10 thermal cycles from 25 °C to 150 °C when the re-torque procedure is followed. Published data for this specific configuration is limited, but the failure mode observed on similar annular groove flanges involves loss of residual seating stress on cool-down when re-torque is omitted.

    Installation begins with solvent degreasing of the sealing faces using isopropanol or acetone. The tape is applied without stretching because stretching reduces cross-sectional thickness and creates thin lanes. Tape ends are cut on a 45° scarf joint and overlapped by 5 mm to 10 mm. The adhesive layer holds the tape during vertical installation but does not provide the seal; bolt-induced compression creates the sealing interface. Multiple tape layers may be used to correct gross surface defects, but the total stack height should not exceed 3.2 mm unless flange rotation and bolt length have been re-evaluated. Surface finish controls the quality of the sealing interface. The tape seals against machined flange surfaces from Ra 1.6 µm to Ra 6.3 µm. On surfaces smoother than Ra 0.8 µm, the lack of mechanical interlock can allow creep and radial movement; on surfaces rougher than Ra 12.5 µm, single-layer thickness may be insufficient to fill the peak-to-valley distance and a two-layer stack is required.

    Bolt preload is applied in three equal increments of 30%, 60%, and 100% of target torque in a star pattern. Target assembly stress for this product class is 7 MPa to 14 MPa on carbon steel flanges and 4 MPa to 8 MPa on FRP or glass-lined flanges. After 24 hours at ambient temperature, re-torque is performed to the target value. PTFE cold flow produces a seating stress loss of 15% to 25% during the first day; without re-torque, blowout margin can drop below design values on flanges operating above 40 bar. The assembly sequence follows the flange qualification principles of ASME PCC-1, but final torque is determined by the flange material specification and bolt grade. In saturated steam service at 150 °C and 6 bar, the tape is typically installed as a single layer on raised-face flanges. Because PTFE has a coefficient of thermal expansion approximately 10 times that of carbon steel, heating from ambient to operating temperature expands the gasket and can cause extrusion if initial seating stress exceeds 14 MPa. Over-compression above 18 MPa produces permanent thinning, reduces recovery, and results in leak-tightness loss on cool-down. The compressed thickness should be maintained within 20% of the original value. These values are consistent with the creep-relaxation behavior measured under ASTM F38 for expanded PTFE gasket materials.

    When large-diameter FRP flanges require low seating stress

    On fiberglass-reinforced plastic piping, allowable bolt stress is lower than on steel. A rigid filled PTFE gasket may require more than 15 MPa to seal, while Chesterton 850 seats at 4 MPa to 8 MPa. Applying the rigid gasket to a DN 300 FRP flange can produce flange rotational deformation and uneven compression. The expanded tape permits sealing of surfaces with out-of-flatness up to 0.4 mm without exceeding the flange moment capacity. Gasket width is selected so that the compressed tape remains within the flange raised face. For a DN 150 Class 150 raised-face flange, a 12.7 mm wide tape is commonly used; for a DN 400 flange, a 19.0 mm wide tape may be required to prevent intrusion into the bore. The tape should be centered on the raised face and not allowed to enter the process stream because fragments can detach and contaminate downstream instrumentation.

    Use of the 850 tape as a substitute for tapered pipe thread sealant is not recommended. Tapered pipe threads require a thin PTFE film to act as a lubricant and filler; the expanded tape is too thick for thread root engagement and can prevent proper makeup. For threaded connections, a separate thread-sealing tape is used. Swelling of PTFE is effectively zero in common solvents; the material does not exhibit the volume change seen in nitrile or EPDM gaskets. The lack of swelling maintains dimensional stability but also removes the self-sealing swell response that some elastomeric gaskets provide in water service. Mechanical compression, rather than media absorption, must generate the seal.

    Chemical service boundaries restrict PTFE beyond its thermal limit

    Chesterton 850 Premium Sealing Tape is resistant to aqueous mineral acids, alkalis, aliphatic and aromatic solvents, chlorinated organics, and oxidizing media within the stated temperature window. The material is not recommended for molten alkali metals, elemental fluorine gas, chlorine trifluoride, or other strong fluorinating agents because reaction with the polymer matrix becomes significant above 150 °C. In hydrofluoric acid service up to 90 °C, PTFE has shown acceptable inertness in standard immersion testing under ASTM D543; however, the adhesive backing is not part of the chemical barrier and may soften under prolonged contact with ketones or esters. For those duties, the adhesive layer is removed or shielded by a full-width PTFE overlap.

    Oxygen service is restricted to low-pressure, low-temperature conditions. Published data for this specific configuration is limited; in high-pressure gaseous oxygen systems above 20 bar, adiabatic compression within the porous expanded PTFE structure may generate localized temperatures sufficient for ignition. A separate oxygen-compatible sealing product should be selected when oxygen purity exceeds 99.5% or when flow velocity exceeds 30 m/s. The evaluation of nonmetallic materials in oxygen-enriched environments is guided by ASTM G63 and ASTM G88.

    Compliance Matrix for 850 in Food, Pharmaceutical, and Industrial Contact Applications

    Standard or regulationScopeApplicable status
    FDA 21 CFR 177.1550PTFE as a food-contact componentApplicable to the PTFE matrix when supported by manufacturer declaration
    USP Class VIPlastic material biological reactivityApplicable to non-porous PTFE film form
    EU 1935/2004Materials intended for food contactCompliant subject to supporting declaration
    REACHRegistration, evaluation, authorisation of chemicalsNo SVHC above 0.1% w/w
    RoHS 2011/65/EURestriction of hazardous substancesNo restricted substance over threshold

    The adhesive carrier film is not intended for direct food contact, and the adhesive side should be oriented away from the product stream. In pharmaceutical split-body pumps, the tape is installed so that only the non-adhesive PTFE edge is exposed to the process fluid. Vacuum service below 1 mbar absolute requires a continuous PTFE butt joint with no exposed adhesive because outgassing of the adhesive layer can degrade chamber pressure. Storage of rolled tape should avoid direct sunlight and temperatures above 30 °C to prevent adhesive transfer. The product has no specific shelf-life limit when the release liner remains intact.

    Top