| HS Code | 670630 |
| Material Type | High Density Polyethylene (HDPE) |
| Grade | PE100HDH-8M |
| Pe Classification | PE100 |
| Density | 0.959 g/cm³ |
| Melt Flow Rate 190 C 5 0 Kg | 0.8 g/10 min |
| Tensile Strength At Yield | 23 MPa |
| Tensile Strength At Break | 33 MPa |
| Elongation At Break | >600% |
| Flexural Modulus | 1000 MPa |
| Environmental Stress Crack Resistance | >5000 h |
| Vicat Softening Temperature | 125 °C |
| Brittleness Temperature | <-70 °C |
| Carbon Black Content | 2.5% |
| Oxidation Induction Time | >20 min |
| Thermal Conductivity | 0.4 W/m·K |
| Specific Heat | 1.9 kJ/kg·K |
| Linear Thermal Expansion | 1.5E-4 /°C |
| Processing Method | Pipe Extrusion |
| Color | Black |
| Form | Pellets |
As an accredited Chase Plastics HDPE PE100HDH-8M factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Chase Plastics HDPE PE100HDH-8M is supplied in 25 kg bags, 40 bags per pallet (1,000 kg), palletized and stretch-wrapped for shipment. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with palletized 25 kg bags of Chase Plastics HDPE PE100HDH-8M, shrink-wrapped and secured for ocean transport. |
| Shipping | Chase Plastics HDPE PE100HDH-8M is a non-hazardous high-density polyethylene resin. It is not regulated as dangerous goods for road, air, or sea transport. Ship in sealed bags, boxes, or octabins; keep dry and avoid contamination. No UN number, hazard class, or packing group required. |
| Storage | Store Chase Plastics HDPE PE100HDH-8M in a cool, dry, well-ventilated area, away from direct sunlight, heat, flames, and strong oxidizers. Keep in original, closed, labeled containers or bags on pallets, protected from moisture, contamination, and physical damage. Avoid excessive stacking. Store off the floor and away from incompatible materials. Use appropriate PPE and follow the manufacturer’s SDS and local regulations. |
| Shelf Life | No specific shelf life; typically indefinite when stored unopened, dry, cool, and away from UV, moisture, and contaminants. |
Chase Plastics HDPE PE100HDH-8M is handled as a PE100-class high-density polyethylene for pressure pipe and containment applications. The distributor’s certificate of analysis should be checked for lot-specific melt flow, density, and oxidation induction time before line start, because PE100 compounds vary in comonomer type and molecular weight distribution even within the same classification. Under ISO 12162-1:2017, PE100 requires a minimum required strength of 10 MPa at 20 °C for 50 years in hydrostatic testing. The compound is typically processed on a grooved-barrel single-screw extruder with an L/D ratio of 36:1 to 40:1. Temperature profile is staged from 175–190 °C in the feed zone, 200–220 °C in the compression zone, 210–225 °C in the metering zone, and 210–230 °C at the die head. Melt temperature is held within 190–230 °C; excursions above 240 °C accelerate oxidation gel formation and reduce long-term hydrostatic strength after notched pipe testing. Head pressure is normally 150–350 bar depending on pipe diameter and die land length. Screen packs up to 200 µm are used to trap oxidized contaminants; tighter packages raise backpressure and shear heating to the point where the antioxidant package is consumed. Wall thickness is set through vacuum sizing at 15–20 °C water and verified with ultrasonic gauges or circumference tapes. Die mandrel and spider leg design must avoid dead spots because stagnant melt produces crosslinked gels that fail hydraulic pressure tests.
For black potable water pipe, the blend consists of 100 parts virgin PE100HDH-8M with 2.0–2.5 wt% of a PE-based carbon black masterbatch to achieve a final carbon black content of 2.0–2.5 wt% as required by ISO 4427-1. Antioxidant masterbatch is added at 0.2–0.5 wt% to maintain oxidation induction time above 20 min at 210 °C when tested by ISO 11357-6:2018. No desiccant drying is required if pellet surface moisture is below 0.05%; higher moisture produces microvoids at the spider weld line and reduces circumferential tensile properties. Clean in-house regrind from start-up pipes is introduced at 10–30 wt% only after hydrostatic re-qualification under the producer’s ISO 4427 programme. External recycled resin is not used in potable pressure pipe unless it is validated under the same long-term hydrostatic design basis.
Compliance is anchored to ISO 4427-2:2019 for pipe dimensions, ISO 9080:2012 for long-term hydrostatic strength extrapolation, ISO 12162-1:2017 for MRS classification, and ISO 1167-1:2006 for short-term hydrostatic pressure testing. Potable water contact is assessed under FDA 21 CFR 177.1520, EU 10/2011, and NSF/ANSI/CAN 61. Terminal products are municipal water mains, service laterals, irrigation feed lines, and industrial water transfer pipes where buried joints use butt fusion and electrofusion with equipment meeting ISO 21307:2017.
In fuel gas distribution, PE100HDH-8M is processed under the same PE100 classification, but the acceptance envelope changes because the operative failure modes include rapid crack propagation and slow crack growth, not only creep rupture. The S4 critical pressure test of ISO 13477:2008 is performed on notched pipe at 0 °C to determine the critical pressure above which a fast-running crack propagates along the pipe axis. The requirement is that the critical pressure exceeds the maximum operating pressure of the pipeline by a safety margin defined in ISO 4437-1 and EN 1555-1. The notched pipe slow crack growth test of ISO 13479 is run under internal pressure at 80 °C for extended periods; brittle failure before the specified time disqualifies the lot. Gas pipe extrusion therefore requires tighter wall thickness eccentricity control, lower gel counts, and stricter regrind discipline than non-pressure conduits.
The extrusion line uses a grooved-barrel extruder with barrier screw, in-line gravimetric dosing for carbon black or yellow masterbatch, and vacuum sizing. Melt temperature is maintained at 190–230 °C; barrel cooling in the feed zone is applied to prevent premature melting and bridge formation. For black gas pipe, carbon black masterbatch is added at 2.0–2.5 wt% to final carbon black content of 2.0–2.5 wt%. For yellow gas pipe, a non-migratory, cadmium-free organic/inorganic pigment masterbatch is added at 0.3–0.8 wt%; this lower loading reduces particulate contamination but requires dispersion monitoring. In-house regrind from clean, dry start-up pipes is typically limited to 10–30 wt%, but external regrind is generally excluded because notched pipe results can shift. Field experience on older extrusion lines shows batch-to-batch yellow pigment dispersion can produce wall thickness gauge noise, which is controlled by ash testing and X-ray fluorescence spot checks at start-up.
| Test | Standard | Condition | PE100 target |
|---|---|---|---|
| Melt mass-flow rate | ISO 1133-1:2022 | 190 °C, 5 kg | 0.2–1.4 g/10 min typical PE100 pipe |
| Density | ISO 1183-1:2019 | 23 °C | 0.945–0.965 g/cm³ base resin |
| Long-term hydrostatic strength | ISO 9080:2012 | 20 °C, 50 years | 10 MPa MRS |
| Rapid crack propagation S4 | ISO 13477:2008 | 0 °C, notched pipe | P_c above maximum operating pressure |
| Slow crack growth notched pipe | ISO 13479 | 80 °C, hydrostatic | No brittle failure before specified hours |
| Carbon black content | ISO 6964:2019 | 23 °C | 2.0–2.5 wt% |
Terminal products are buried natural gas mains, service risers, and liquefied petroleum gas distribution pipes where electrofusion and butt fusion joints are executed under ISO 21307:2017. The reason gas standards require RCP testing is that a fast-running crack can propagate hundreds of metres at low temperatures; the S4 test is the main control for this failure mode, and it must be repeated when processing conditions alter molecular orientation in the pipe wall.
For flat-die geomembrane lines producing 0.5 mm to 3.0 mm HDPE sheet, PE100HDH-8M is formulated to the cell classification requirements of ASTM D3350-21 when the terminal use is environmental containment. The process is a single-screw extruder with screen changer, flexible die lip, and a three-roll stack. Melt temperature is held at 200–235 °C, and the roll stack is maintained at 60–100 °C to balance surface oxidation, gloss, and residual stress. A carbon black masterbatch concentrate is added at 2.0–3.0 wt% to achieve final carbon black content of 2.0–3.0 wt% and outdoor UV stabilisation. Antioxidant masterbatch addition is 0.3–0.8 wt% depending on the specific geomembrane specification. Processing aid concentrate may be used at 0.02–0.1 wt% to reduce melt fracture at high line speeds; higher loadings are not typical because they can reduce sheet weldability.
Compliance is anchored to ASTM D1505-18 for density, ASTM D1238-20 for melt flow, ASTM D6693-16 for tensile properties, ASTM D5397-20 for stress crack resistance, and ASTM D5890-19 for water vapour permeance. Terminal products are landfill basal liners, capping layers, leach ponds, mining heap leach pads, and secondary containment basins. Welding is performed by hot-wedge and extrusion welding under ASTM D6392-12; joint integrity is checked by vacuum box and air channel methods. Weld failure is often traced to surface oxidation during sheet cooling, so roll temperature is kept below 100 °C to avoid the formation of a weak surface layer that reduces peel strength. Published data for this exact configuration is limited; the ranges above are taken from PE100 geomembrane processing practice.
On corrugated cable conduit lines using moving mould-block corrugators, PE100HDH-8M is processed into structured-wall ducts for power and telecommunication cables. The extruder is normally a single-screw machine with L/D ratio of 30:1 to 36:1; melt temperature is set between 180–220 °C. Blow air pressure inside the tube is maintained at 0.2–0.5 bar and vacuum at 100–200 mbar differential to pull the melt into the corrugator mould blocks. The main production defect is wall thinning at the corrugation inner radius, which is controlled by blow air pressure, screw speed, and melt strength rather than by barrel temperature alone. The blend is normally run with 1.0–2.0 wt% carbon black masterbatch and 2.0–10.0 wt% clean in-house regrind from punching scrap and start-up conduit. No desiccant drying is required unless pellets are stored in outdoor silos with surface moisture above 0.1%. Compliance is governed by EN 61386-1 for conduit systems, UL 651 for HDPE conduit, and ASTM F2160-16 for HDPE communications duct. Terminal products are underground cable protection duct, micro-duct bundles, and air-blown fibre conduit. The process is less sensitive to hydrostatic design basis than pressure pipe, but impact strength and crush resistance after installation are the controlling mechanical properties.
When an accumulator-head blow moulding line is used for UN-rated packagings, PE100HDH-8M is processed at a lower melt temperature than pipe extrusion to preserve parison melt strength. Melt temperature is set at 180–210 °C, blow pressure is 6–9 bar, and mould cooling water is held at 8–20 °C. Parison programming adjusts wall thickness between the pinch-off weld and the sidewall to prevent thin spots at the container corners. For 200 L open-head drums, the die gap is typically 0.6–1.2 mm, and the parison is pre-blown to stabilise the bubble before mould closing. The material must fill the mould without jetting, because weld lines at the pinch-off are the lowest ESCR region. Pinch-off temperature and clamping speed are controlled to avoid excessive orientation that produces brittle failure in drop tests. Published data for this specific grade in UN-certified packagings is often limited to the converter’s internal qualification; the conditions above reflect the standard PE100 blow moulding envelope.
The blend is usually 100 parts PE100HDH-8M with 0.2–0.5 wt% antioxidant masterbatch, 2.0–2.5 wt% carbon black or 0.2–0.8 wt% organic pigment, and 0.05–0.15 wt% fluoropolymer processing aid. Higher processing aid loadings do not improve the surface beyond a loading of 0.15 wt% and may reduce print adhesion on the container sidewall. ESCR is tested under ASTM D1693-15 Condition B, and chemical resistance is evaluated by ASTM D543-21 against the specific fillings. Terminal products are UN-certified 30 L, 60 L, 120 L, and 220 L open-head and tight-head drums, IBC liners, and agricultural chemical containers. UN certification follows drop tests, stacking tests, and hydrostatic pressure tests under ADR/RID and IMDG packaging instructions; the specific drop height and stack duration depend on product relative density and packing group. Incompatibilities include chlorinated solvents and strong oxidisers, which require barrier treatment or an alternative resin system because PE100HDH-8M is a non-barrier olefin polymer unless a barrier layer is coextruded.
Competitive Chase Plastics HDPE PE100HDH-8M prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Chase Plastics HDPE PE100HDH-8M is a high-density polyethylene pipe-grade resin distributed for pressure piping applications. The designation combines the ISO 12162 PE100 classification with a supplier-specific suffix, HDH-8M, for which published third-party data are limited; grade-specific certificate values from the Chase Plastics technical datasheet should be consulted for melt flow rate, density, and additive package. The PE100 classification is assigned when a material demonstrates a minimum required strength of 10 MPa at 20°C for a 50-year service life derived from ISO 9080 regression of ISO 1167 hydrostatic test points. The resin is produced as a bimodal high-density polyethylene with a density range typical of HDPE pipe compounds, 0.950 g/cm³ to 0.965 g/cm³ when measured to ISO 1183-1; the bimodal molecular weight distribution separates the low-molecular-weight fraction needed for extrusion shear flow from the high-molecular-weight fraction that raises slow crack growth resistance and hydrostatic design life.
The design stress for PE100 is calculated using the ISO 12162 minimum required strength of 10 MPa divided by the overall service coefficient of 1.25, yielding a design stress of 8.0 MPa for water at 20°C. Pressure rating follows P = (2σs)/(SDR−1); SDR 17 yields 1.0 MPa (PN10), and SDR 11 yields 1.6 MPa (PN16). These ratings are valid for water at 20°C with 50-year hydrostatic extrapolation; higher temperatures require derating factors under EN 12201-1 or ISO 4427-1. For gaseous fuel distribution, the design stress must be adjusted by the service coefficient and the system-specific design factor given in ISO 4437-3.
Compliance evaluation for PE100HDH-8M is performed at the pipe level, not on raw granules alone. Hydrostatic strength regression under ISO 9080 uses finished pipe specimens tested according to ISO 1167, because extrusion-induced orientation, wall thickness variation, weld lines, and cooling history influence long-term failure behavior. The matrix below summarizes the standards applicable to PE100 pressure pipe compounds.
| Standard | Parameter | Requirement |
|---|---|---|
| ISO 9080:2022 | Long-term hydrostatic strength regression in pipe form | Minimum required strength ≥ 10 MPa at 20°C for 50 years |
| ISO 12162:2009 | Material classification | PE100 |
| EN 12201-1:2011 | Polyethylene materials for water supply | PE100 with design stress 8.0 MPa at 20°C |
| EN 12201-2:2011 | Pipes for water supply | Hydrostatic strength at 20°C and 80°C per ISO 1167 |
| ISO 4437-3:2014 | Gas distribution pipes | PE100 designation; system design factor per national code |
| ASTM D3350-21 | HDPE cell classification | Cell class from certificate of analysis; not assigned here |
Grade-specific measured values for melt flow rate, density, tensile yield strength, elongation at break, and thermal stability are not constant across production lots. Published test data for the HDH-8M suffix are limited; certificate-of-analysis data should be requested for each lot. Where hydrostatic design is required, qualification tests are conducted on finished pipe because extrusion conditions, thermal history, and dimensional tolerances influence final performance more than raw-resin powder properties.
Processing of PE100HDH-8M is constrained by melt temperature limits and shear history. Industrial pipe lines commonly use grooved-feed single-screw extruders with L/D ratios between 30:1 and 36:1. The melt temperature should remain between 200°C and 220°C for most PE100 compounds; excursions above 240°C accelerate oxidation, deplete hindered phenolic stabilizers, and shorten oxidation induction time when measured to ISO 11357-6. Feed-zone settings are typically 180°C to 200°C; compression 190°C to 205°C; metering 200°C to 215°C; die 210°C to 220°C. Head pressure is die-dependent, and line operators should monitor melt pressure and die-lip exit temperature uniformity. Surface moisture from humid storage at relative humidity greater than 60% may produce pinhole defects; pre-dry at 70°C to 80°C for 2 h to 3 h using dehumidified air.
Bimodal high-molecular-weight tail increases shear viscosity; melt fracture may occur if the die shear rate exceeds the critical value for the die geometry and melt temperature. The safe shear-rate window is grade-specific and must be established by die pressure-speed sweeps; published data for this specific configuration are limited. In-house regrind from clean PE100 pipes may be added only after verification of hydrostatic strength per EN 12201-2; national drinking-water approvals may set upper limits. Welding and joining of reclaimed material require case-by-case validation.
Buried potable water distribution lines with intermittent pressure surges represent a primary use. The design pressure is the lower of sustained hydrostatic rating and cyclic surge fatigue; PE100HDH-8M is specified as SDR 17 for 10 bar water networks and as SDR 11 for 16 bar transmission mains. Resistance to slow crack growth is critical at stress risers such as scratches from rock impingement and tap tees. In notched pipe testing under ISO 13479, PE100 resins exhibit extended failure time relative to PE80; however, the HDH-8M grade-specific notched pipe life should be taken from the supplier’s certificate, not from class-average published literature. Jointing methods include butt fusion to ISO 21307 and electrofusion to ISO 12176-2; both require scraping of oxidized skin immediately before welding. Fusion at pipe surface temperatures below 5°C, in wet conditions, or under wind chill without protection reduces weld reliability.
Substitution changes pressure ratings and wall-thickness schedules. Because PE80 uses a minimum required strength of 8 MPa and PE100 uses 10 MPa, the water-service design stress rises from 6.3 MPa to 8.0 MPa at a service coefficient of 1.25. The pressure classes below apply to water at 20°C.
| SDR | PE80 water PN class | PE100 water PN class |
|---|---|---|
| 11 | PN12.5 | PN16 |
| 17 | PN8 | PN10 |
| 21 | PN6 | PN8 |
| 26 | PN5 | PN6 |
At equal outside diameter and pressure requirement, PE100 permits a lower SDR, meaning a thinner wall, increasing internal diameter and reducing material mass per meter. At equal SDR, PE100 permits higher operating pressure. These differences influence pumping energy and surge response; however, lower wall thickness also reduces pipe ring stiffness, and buried-pipe buckling resistance must be re-evaluated according to ISO 9969. PE100HDH-8M should not be substituted into an existing PE80 network solely on pressure rating without checking pipe stiffness and thermal expansion compatibility; thinner-wall PE100 may have lower ring stiffness and higher temperature-induced stress.
PE100HDH-8M’s difference from PE80 and lower-density HDPE grades is most significant in slow crack growth resistance and elevated design stress. The bimodal molecular structure provides a tie-molecule network that resists crack propagation from surface defects and stress concentrations. Test methods include ISO 16770 full notch creep test, ISO 13479 notched pipe test, and ASTM D1693 environmental stress crack resistance; pass/fail thresholds vary by standard and end-use specification. For potable water use, many specifications require an oxidation induction time of at least 20 min at 200°C when measured to ISO 11357-6, but this is a material-consistency indicator, not a substitute for pipe hydrostatic testing.
Operational boundaries include continuous process fluids above 40°C; at 40°C the design stress is reduced by a derating factor of 0.74 for water service under conventional design tables, and at 60°C the factor is 0.50. Incompatibilities include strong oxidizing disinfectants such as chlorine dioxide and ozone at elevated concentrations, which can accelerate oxidative degradation and reduce slow crack growth. Aromatic hydrocarbons, concentrated acids, and ketones may permeate or stress-crack the pipe; chemical resistance should be checked against ISO/TR 10358. Compressed gases outside the scope of ISO 4437 require separate qualification. Outdoor storage requires protection from prolonged ultraviolet exposure; compounds containing 2.0 wt% to 2.5 wt% carbon black provide standard weathering resistance under ISO 4427-1, but uncovered stock should be limited.