| HS Code | 450212 |
| Manufacturer | Changzhou Helilai |
| Product Name | ABS FRABS-HA-102 |
| Material Type | Flame-retardant ABS (FRABS) |
| Grade | FRABS-HA-102 |
| Flame Retardant | Yes |
| Processing Method | Injection molding |
As an accredited Changzhou Helilai ABS FRABS-HA-102 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Changzhou Helilai ABS FRABS-HA-102 is supplied in 25 kg moisture-proof bags, palletized for industrial handling and storage. |
| Container Loading (20′ FCL) | Changzhou Helilai ABS FRABS-HA-102 is loaded in a 20′ FCL container, palletized, shrink-wrapped, and secured for dry export transport. |
| Shipping | Changzhou Helilai ABS FRABS-HA-102 is supplied as flame-retardant ABS pellets, typically in 25 kg moisture-barrier bags on pallets. Ship as non-hazardous general cargo; keep dry, cool, ventilated, away from direct sunlight and ignition sources, and avoid bag damage or contamination. |
| Storage | Store Changzhou Helilai ABS FRABS-HA-102 in a cool, dry, well-ventilated warehouse, away from direct sunlight, heat, moisture, and ignition sources. Keep containers sealed, clean, and palletized; prevent physical damage. Store separately from strong oxidizers and acids. Maintain good housekeeping and static control, rotate stock, and follow the manufacturer’s SDS and local regulations. |
| Shelf Life | Changzhou Helilai ABS FRABS-HA-102 has a typical shelf life of 12 months when stored dry, cool, and in original sealed packaging. |
Changzhou Helilai FRABS-HA-102 is processed into miniature circuit breaker bodies, residual current device bases, and surge protective device housings where a stable flame rating must coexist with low warpage and dimensional repeatability after ejection. The first process variable on the production floor is not the melt temperature but residual moisture; a desiccant-wheel dryer set to 80 °C with a dew point of -40 °C is used for 4 h, and vented-air drying is rejected when ambient relative humidity exceeds 60 %. The dried pellets are plasticised in a straight-through screw with L/D between 20:1 and 25:1, compression ratio between 2.0:1 and 2.5:1, and shot size held between 40 % and 70 % of barrel capacity, because over-residence in the barrel degrades the flame retardant package before the melt reaches the cavity. Barrel zones are maintained from 200 °C to 230 °C, the nozzle is held below 230 °C, and maximum cumulative residence time is capped at 5 min. Mold surface temperatures of 50 °C to 70 °C are required to avoid microcracking around crimped brass terminals and metal inserts. A UL 94 V-0 rating on a 2.0 mm plaque does not automatically confer a V-0 result on a 0.75 mm snap-fit rib, because the flame retardant behavior is thickness-dependent and gate location–dependent; published data for this specific HA-102 configuration is limited, so finished-part requalification at the production wall thickness is mandatory before tool release. Regrind is limited to 20 % by weight and is never blended with general-purpose ABS, because inconsistent flame retardant dispersion across regrind lots increases afterflame time at the gate region. Temperatures above 240 °C cause acidic decomposition products that deposit on mold vents and create surface blush, while temperatures below 200 °C produce short shots and weak weld lines in thin ribs. In breaker housings, gate location is shifted away from the arc chamber because weld lines aligned with contact separation zones reduce arc tracking resistance and can fail the finish-goods dielectric check.
In charge control modules for alternating-current wall boxes, the first processing conflict is thermal residence during hot-runner gating. The electronic power boards inside a wall-mounted electric vehicle supply equipment unit require an insulating enclosure that satisfies fire propagation, glow wire, and creepage distance rules under IEC 61851-1 and IEC 62196. For this housing, the hot-runner manifold is held no more than 10 °C above the front-zone melt temperature, because externally heated nozzle dead spots create black specks that mark flame retardant decomposition. Mold-fill simulation should use a melt viscosity curve fitted to the supplier’s melt mass-flow rate under ISO 1133-1:2022; published data for this specific grade is limited, so the batch certificate of analysis must correct the model before cutting steel. Outdoor installation is not addressed by the flame retardant package alone, because flame-retardant ABS with a butadiene-rich rubber phase embrittles under prolonged UV exposure; the component survives only when it is protected by a painted metal cover, overmolded with a weatherable capstock, or installed in a covered location. Mounting bosses must be checked for low-temperature impact resistance, and brittle fracture of thin-wall bosses at -25 °C can be expected if the boss geometry is not modified; the design rule used on the production line is a minimum boss outer diameter of 2.5 mm plus twice the thread minor diameter. Final assembly testing follows IEC 60695-2-11 at the end-product temperature, not merely at the material’s GWFI value, because the glow wire interacts with terminals, relays, and potting compounds in the finished part. Sink marks near standoffs must be measured before creepage distance is certified, because a 0.2 mm sink can reduce the clearance between live metal and a grounded enclosure wall below the minimum creepage required by IEC 60664-1.
The discrepancy between a UL 94 V-0 plaque rating and a finished-part glow wire result becomes visible when an air fryer controller housing, a washing machine drain pump cover, or a coffee boiler junction box is submitted to household appliance safety testing. The appliance fire risk is evaluated by applying a glow wire at 650 °C, 750 °C, or 850 °C depending on the monitored current, supervision status, and location of live parts. The material’s UL 94 V-0 rating is not equivalent to a glow wire pass, because vertical-burn testing evaluates a clamped strip under a controlled ignition source, while glow wire testing places a heated resistive element on an assembled enclosure that contains conductors and terminals. Material suppliers should provide data under IEC 60695-2-12 for glow wire flammability index and IEC 60695-2-13 for glow wire ignition temperature, while the finished product is tested under IEC 60695-2-11. In this segment, FRABS-HA-102 is selected only after the circuit condition is defined, because a shift from 650 °C to 850 °C can move a flame-retardant ABS from no ignition to sustained ignition if the wall thickness below the test point is less than 1.5 mm. Tooling uses pin gates on hidden side walls rather than sprue gates on visible faces, because flame-retardant ABS shows gate blush on high-gloss control fronts. The mold is warmed to 60 °C, and the packing curve is stepped from 60 MPa to 35 MPa over 4 s to reduce gate-area stress. When a live connector carries more than 0.2 A in an unattended appliance, the typical end-product requirement is a 750 °C glow wire test; parts with a 1.0 mm wall often fail at the weld line, not on the flat surface, because the weld line represents a local thickness and orientation discontinuity. The corrective action is to vent the weld line area, slow the injection speed to 55 % of the cavity maximum fill rate, and place a flow leader along the noncritical edge so the melt front meets at a less stressed region.
Because the fire enclosure standard evaluates the complete part rather than a flat plaque, office automation rear covers and printer power-supply trays processed from FRABS-HA-102 must be validated with ventilation slots, snap features, and mounting bosses intact. The barrel is set from 200 °C to 220 °C for these large-area molds, and the critical quality variable is flatness after ejection, not initial flame rating. Mold texturing requires a draft angle of 0.5 % to 0.7 % on side walls because flame-retardant ABS fills with a more viscous melt front than general-purpose ABS; insufficient draft produces scuffing and white stress marks on black or dark gray covers. Hot-runner valves are sequenced to eliminate gas traps at the junction of the power-supply pocket and the outer rim, with gas vent depth kept at 0.015 mm to 0.025 mm and vent land limited to 2.0 mm. The heat deflection temperature of this material class under ISO 75-2:2013 method A typically falls between 80 °C and 95 °C at 1.82 MPa; final-part validation therefore includes a 72 h thermal soak at 70 °C with the cover mounted on the chassis to measure snap-fit creep. The material is not used adjacent to fuser rollers in electrophotographic printers because continuous local temperatures above 90 °C exceed the practical service range of unmodified flame-retardant ABS; those zones require a polyester or polycarbonate blend. For external desktop equipment, a 2.0 mm wall is normally suitable for the fire enclosure function under IEC 62368-1, but a wall thickness below 1.2 mm requires requalification because ventilation slots and snap features behave differently from a flat material plaque when exposed to an internal fault ignition source.
For plug-in wall adapter shells, travel charger bodies, and power strip end caps, the processing envelope changes because wall sections are often 0.8 mm to 1.5 mm, and the flow length-to-thickness ratio can exceed 150:1 in multi-cavity tools. FRABS-HA-102 is processed with a rapid injection speed and a cushion of 4 mm to 6 mm to maintain a stable melt seal, because insufficient cushion produces shot-to-shot variation in packing pressure, which shifts the ultrasonic weld collapse distance and creates false rejects on the weld line. Mold temperature in thin-wall adapter shells is raised to 65 °C to extend fill length, but clamp force is not increased to overcome poor venting; burn marks appear at the end of fill when the gas vent depth is insufficient, and these marks are especially visible in white flame-retardant grades. Ultrasonic welding uses a 20 kHz system with a shear joint interference of 0.3 mm; flame-retardant additives reduce the available melt film temperature, so the amplitude and trigger force are raised 10 % to 15 % above general-purpose ABS settings. Wall adapters are additionally tested for abnormal heat from a plugged-in transformer coil; a V-0 rating alone does not prevent the plug blade from rotating if the material softens too much. The Vicat softening point is measured under ISO 306 Method B50 on every incoming lot, because a drop of more than 5 °C signals excessive regrind or contamination by general-purpose ABS. Compliance documentation for adapter shells follows IEC 62368-1 for information technology equipment or IEC 60335-1 for household appliance-associated power supplies; the governing standard must be declared before a resin lot change, because a material approved for a monitor power adapter does not automatically cover a kitchen-appliance power module.
| Application segment | Standard/Test Method | Critical Check for FRABS-HA-102 |
|---|---|---|
| Low-voltage circuit protection | UL 94, IEC 60695-2-12 | V-0 at finished-part minimum thickness; weld-line position |
| Household appliance controls | IEC 60335-1 Clause 30.2, IEC 60695-2-11 | End-product glow wire temperature, current > 0.2 A |
| EVSE charge control | IEC 61851-1, IEC 62196 | Low-temperature boss impact, UV protection, creepage after sink |
| IT/AV fire enclosures | IEC 62368-1 | Fire enclosure function at 1.2 mm to 2.0 mm |
| Insulation coordination | IEC 60664-1, IEC 60112 | CTI versus pollution degree, surface cracking |
| Mechanical performance | ASTM D638-14, ISO 178, ISO 179-1:2010 | Tensile, flexural, notched impact at service temperature |
Building automation controller bases, HVAC relay covers, and indoor security camera mounts processed from FRABS-HA-102 are typically dark gray or black to stabilize the flame-retardant heat history and to hide UV-induced color shift in window-adjacent installations; the dominant failure observed on the production line is not flammability but stress crack formation along molded-in terminal slots after humidity cycling. The material is dried to a residual moisture target below 0.05 %, and the packing profile is kept moderate because overpacking around terminal slots creates internal stress that relaxes under 85 °C and 85 % relative humidity and opens microcracks between live terminals. The material’s surface resistivity under ASTM D257 is commonly reported at 10^14 Ω or higher for this class, but the electrical insulation value is irrelevant if stress cracks bridge the creepage path. For 24 V bus-powered controllers, the creepage distance requirements under IEC 60664-1 are lower than for mains voltages, but the component still functions as an insulating barrier between the printed circuit board and a grounded steel backplate. The material should not be solvent-bonded with ketone-based solvents, because these attack the rubber phase and initiate environmental stress cracking along weld lines; mechanical fasteners or ultrasonic welding are used instead, with the horn frequency selected as 15 kHz or 20 kHz according to wall thickness and joint geometry. Published data for this specific grade under damp heat cycling is limited, so electrical strength after 1000 h at 85 °C and 85 % relative humidity should be verified on the finished controller assembly before production release.
Static electricity meter housings, disconnect switch covers, and grid-meter terminal shrouds specify flame retardant ABS because the enclosure must hold live metrology boards and screw terminals without adding a separate insulating liner. Under IEC 62052-11 and IEC 62053-21, the energy meter is tested for heat, fire, and electrical insulation under specified environmental conditions; the polymer must maintain its insulation coordination after damp heat, not only at ambient laboratory conditions. FRABS-HA-102 is injection molded here with a melt temperature of 210 °C to 230 °C and a mold temperature of 60 °C, and the pressure-holding phase is kept short to avoid excessive residual stress around the terminal block windows. The main risk in this application is not a continuous flame but a high-voltage arc across a contaminated surface; the comparative tracking index measured under IEC 60112 must be checked against the pollution degree defined in IEC 60664-1, because a low CTI value forces the terminal pitch to be opened beyond what the compact meter housing allows. Printed result labels and laser marking should be tested on molded plaques, because flame-retardant ABS can exhibit poor laser contrast in dark colors and may require a silicone-free marking compound. The terminal seals must be tested for torque retention after 500 h at 80 °C; low-molecular-weight flow additives can migrate to the surface and reduce screw retention if the material is overdried or overheated. Published data for this specific grade under metering end-product standards is limited, so a full compliance test on the complete meter is required before certification bodies accept the housing as an insulation barrier.
Competitive Changzhou Helilai ABS FRABS-HA-102 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Changzhou Helilai FRABS-HA-102 is a flame-retardant acrylonitrile-butadiene-styrene compound supplied in pellet form for injection moulding and, where the supplier’s processing guide permits, narrow-profile extrusion of electrical and electronic enclosure components. The grade belongs to the manufacturer’s halogenated FR ABS portfolio. The designation does not by itself define minimum wall thickness for flammability; the current UL 94 yellow card and the supplier’s batch certificate are the authoritative sources for the exact class, thickness, and colour range. The material is intended for components that require self-extinguishing vertical burn behaviour while retaining sufficient melt-viscosity reduction for thin-wall cavities. Compared with unmodified ABS, the flame-retardant system narrows the permissible thermal processing window and alters the balance of melt volume-flow rate, notched impact, and heat deflection temperature.
Incoming resin acceptance should include melt volume-flow rate by ISO 1133-1:2022, density by ISO 1183-1:2019, and moisture by ISO 15512. These values should be trended across at least five consecutive lots, because a single point does not establish lot-to-lot variance. On injection moulding machines with clamp force between 800 kN and 1600 kN, drift in apparent viscosity can move the filling pattern in a multi-cavity tool, particularly when the runner system is unbalanced or when the cavity contains narrow pin cores and blade-like ribs. Cavity-pressure sensors with a sampling rate of at least 1 kHz are preferred for separating resin variation from machine and non-return valve variation. If the material is moulded on a hot-runner system, no manifold zone should be left stagnant during cycle interruptions, and the manifold temperature must remain below the supplier’s maximum melt-temperature ceiling.
The product is commonly proposed for thin-wall electrical enclosures, power adapter shells, switch covers, sensor housings, and similar components where the wall section is below 2.5 mm. For any specific component, the flow-length-to-wall-thickness ratio, gate land dimensions, and packing pressure are more relevant than a single melt-flow value. Spiral-flow testing may be used as a comparative tool, but production tool results are required for release; published data for this specific configuration is limited.
A specification review should be organized around the methods listed below. These methods provide comparable specimen-level data but do not replace end-product fire testing at the moulded wall thickness.
| Property | Method | Unit | Evaluation basis |
|---|---|---|---|
| Density | ISO 1183-1:2019 | g/cm³ | Report against supplier certificate of analysis |
| Melt volume-flow rate | ISO 1133-1:2022 | cm³/10 min | Supplier-specified temperature and load |
| Tensile stress at yield | ISO 527-2:2012 | MPa | Conditioned at 23°C / 50% RH |
| Tensile strain at break | ISO 527-2:2012 | % | Test speed per supplier datasheet |
| Flexural modulus | ISO 178:2019 | MPa | Test speed 2 mm/min |
| Notched Izod impact | ISO 180/A | kJ/m² | Type A notch, edgewise impact |
| Vicat softening temperature | ISO 306/B50 | °C | 50 N load, 50°C/h heating rate |
| Heat deflection temperature | ISO 75-2:2013 | °C | Method A, 1.8 MPa |
| Mould shrinkage | ISO 294-4:2018 | % | Parallel and perpendicular to flow |
| Vertical burning | IEC 60695-11-10:2013 | class | Minimum thickness from UL yellow card |
| Glow-wire flammability index | IEC 60695-2-12:2021 | °C | Plaque or part thickness must be reported |
| Comparative tracking index | IEC 60112:2020 | V | Solution A, production colour |
| Ash content | ISO 3451-1:2019 | % | Method A or B per supplier |
| RoHS restricted substances | 2011/65/EU | mg/kg | Supplier declaration per Annex II |
| REACH SVHC | 1907/2006 | % w/w | Article 33 communication if applicable |
Values in a certificate of analysis are single-point results on standardized specimens conditioned according to ISO 291; they are not design allowables. For continuous use, the relative thermal index from UL 746B must be obtained from the current UL yellow card. Any substitution of another grade should be validated under the same specimen region of the moulding, because knuckle lines, weld lines, and gate-induced orientation can reduce performance below nominal data. Published data for this specific configuration is limited; therefore, the supplier’s certificate of analysis and current UL file are the controlling input to material release.
Halogenated flame-retardant ABS systems generally degrade at elevated temperature; in brominated-antimony formulations, decomposition can become rapid above 240°C, although the exact onset for FRABS-HA-102 must be taken from supplier thermogravimetric data. The process temperature must be measured at the melt, not only at the barrel wall, because shear heating behind the check valve can be 10–20°C higher than the barrel setpoint. Melt residence time should be kept to the supplier-specified maximum. If the supplier does not provide a numerical maximum, the plant should use the shortest residence time consistent with complete plasticization and should validate it with a fill-and-hold study. Over-temperature exposure can reduce the UL 94 performance of the compound even when the part visually appears acceptable.
Screw design influences the temperature peak. A general-purpose screw with a compression ratio above 2.5:1 may over-shear a flame-retardant grade if operated at high back pressure. Screws with L/D ratio between 20:1 and 22:1 and a low-shear mixing profile are common. The non-return valve should be inspected frequently because accumulated deposit can reduce sealing and increase recovery time. Injection speed should be balanced to allow adequate fill through restrictive sections without producing excessive shear. If the material is processed on an extrusion line, screen packs should be selected to avoid melt-temperature rise, and breaker plates should be cleaned at regular intervals.
Mould temperature between 40°C and 70°C is typical for FR ABS. Lower temperatures may reduce gloss and increase frozen-in stress; higher temperatures may increase cooling time without a proportional gain in dimensional control because ABS is amorphous. Turbulent-flow water units with sufficient flow rate are required; a mould-temperature controller that cannot hold the setpoint within ±5°C can create local shrinkage variation. For tight-tolerance parts, the cooling circuit should be balanced so that cavity and core temperatures differ by no more than the supplier’s recommended differential.
Because halogenated flame-retardant packages can release acidic degradation products during moulding, tool steel selection and maintenance are part of the process window. Vents, cores, ribs, and gate lands should be inspected at intervals specified by the processor; mould deposit in these regions can reduce venting and increase local shear, which further accelerates decomposition. Hard-chrome plating or stainless tool steels with high chromium content can reduce corrosion, but no tooling material eliminates the source of degradation. A vent depth of 0.02–0.03 mm is common for ABS, but flame-retardant ABS may require more frequent cleaning because residue closes vents and raises cavity pressure. If cavity pressure rises without a change in injection setpoints, the tool should be cleaned before adjusting the process. Direct gas extraction at the mould parting line and local exhaust over the clamp are used on production lines to remove volatile compounds. Operators should not increase melt temperature to clear short shots caused by blocked vents; instead, the vents should be cleaned and the shot size re-checked.
The flame-retardant activity of halogenated ABS depends on gas-phase radical scavenging and, in many systems, char promotion by antimony trioxide synergy. Final performance is not solely controlled by additive loading; dispersion and phase distribution can shift both flammability and notched impact. If the flame-retardant package is poorly dispersed, the material may exhibit brittle domains, anisotropic shrinkage, and uneven vertical burn results. A twin-screw compounding line with screw speeds of 200–400 rpm and L/D ratio of 40:1 is representative for FR ABS concentrate manufacture, but the manufacturing route for FRABS-HA-102 is proprietary and not publicly available. Incoming pellet homogeneity should be monitored by density, ash content per ISO 3451-1:2019, and melt-flow repeatability across multiple samples.
Regrind from sprues and runners should be added only within the level specified by the supplier. Uncontrolled regrind addition can depress flame retardancy, lower notched Izod impact, and increase variability in glow-wire results. If regrind is used, it must be sieved to remove fines, dried under the same conditions as virgin resin, and not mixed with other polymer types. Even small amounts of polycarbonate, HIPS, or acetal contamination can create delamination or flammability defects; the feed station must be cleaned when changing from another resin. Published data for this specific configuration is limited in public literature, so the processor should generate in-house data at the proposed regrind percentage before releasing production.
Table 2 presents class-level differentiation. It is not a substitute for grade-specific values, and all flammability comparisons require the same wall thickness and same specimen preparation.
| Material class | Flammability behaviour | Mechanical and thermal position | Processing limitation |
|---|---|---|---|
| Unmodified ABS | Typically UL 94 HB or no vertical rating | Lower heat deflection than flame-retardant grade; good impact | Wide processing window; not suitable for live-part enclosures requiring V-0 |
| FRABS-HA-102 | Manufacturer-designated flame-retardant; class and minimum thickness from UL yellow card | High-flow positioning; notched impact and HDT must be confirmed from datasheet | Narrow melt-temperature window; drying required; mould deposit possible |
| FR HIPS | V-0 possible at specified thickness | Lower surface hardness and chemical resistance than ABS | Wider processing window but lower stiffness; may require more flame-retardant addition |
| PC/ABS | V-0 possible at specified thickness | Higher HDT and notched impact; higher melt viscosity | Requires PC-class drying; higher melt temperature; more expensive tooling and energy input |
| PVC/ABS | V-0 possible; char-forming halogenated system | Good chemical resistance; lower thermal stability | Sensitive to residence time; acidic decomposition risk |
Vertical burn classification is thickness-dependent; a material rated V-0 at 1.5 mm may not retain that class at 0.8 mm. The comparison with other classes must therefore be based on the same part geometry, colour concentrate, regrind level, and moulding conditions. FRABS-HA-102 should be compared with standard FR ABS within the same supplier’s portfolio using the same test plaque and same gate location, because the high-flow modification may shift notched impact, heat deflection, and mould shrinkage. In applications requiring contact with live electrical terminals, the comparative tracking index and glow-wire end-product tests are more important than the material’s tensile or flexural values. Published data for this specific configuration is limited; no class-level table substitutes for the current yellow card and the supplier’s certificate of analysis.
Final part qualification for FRABS-HA-102 should include vertical burning on the thinnest and thickest section of the moulded component, glow-wire exposure at the specified end-product temperature, and comparative tracking index on the same colour and regrind ratio as production. The moulder must not assume that natural-resin UL 94 data apply to coloured or filled components; pigments and antistatic masterbatches can move the rating by one class at a given thickness. For snap-fit or load-bearing designs, standard notched Izod or Charpy specimens do not capture gate-induced molecular orientation and sharp-corner stress concentration; prototype parts should be tested under the actual loading rate and temperature. The final user of the grade should retain the supplier’s certification file and inspect every receipt lot against the test matrix in Table 1 until sufficient lot data are available to justify reduced incoming testing. If outdoor service or prolonged contact with hydrocarbon-based cleaning agents is anticipated, the supplier should be asked for stress-cracking and weathering data; ABS flame-retardant grades are generally not intended for continuous outdoor UV exposure without a protective cap layer or UV package. Published data for this specific configuration is limited in the open literature; therefore, the manufacturer’s certificate, UL yellow card, and application-specific qualification remain the controlling documents for Changzhou Helilai FRABS-HA-102.