| HS Code | 604378 |
| Reinforcement | Glass fiber |
| Glass Fiber Content | 15% |
| Density | 1.41 g/cm³ |
| Tensile Strength | 90 MPa |
| Elongation At Break | 3% |
| Flexural Modulus | 5000 MPa |
| Notched Izod Impact Strength | 4 kJ/m² |
| Heat Deflection Temperature At 1 82 Mpa | 200 °C |
| Melting Point | 225 °C |
| Mold Shrinkage | 0.4–0.8% |
| Water Absorption | 0.05% |
| Flammability Rating | UL94 HB |
| Dielectric Strength | 20 kV/mm |
| Volume Resistivity | 1E16 Ω·cm |
As an accredited Chang Chun LONGLITE® PBT+GF 4815 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Chang Chun LONGLITE® PBT+GF 4815 is supplied in 25 kg moisture-proof paper bags, palletized for industrial shipment. |
| Container Loading (20′ FCL) | 20′ FCL dry container loaded with palletized, shrink-wrapped 25 kg bags of Chang Chun LONGLITE® PBT+GF 4815, secured for export. |
| Shipping | Chang Chun LONGLITE® PBT+GF 4815 is supplied as glass-fiber reinforced PBT pellets in moisture-barrier bags, typically 25 kg, palletized. Classified as non-hazardous for transport; keep dry, avoid direct sunlight/heat, and store in a cool, ventilated area. Follow local regulations and the SDS. |
| Storage | Store Chang Chun LONGLITE® PBT+GF 4815 in a cool, dry, well-ventilated area away from direct sunlight, heat, moisture, and ignition sources. Keep containers tightly closed and use original packaging. Prevent dust generation and contact with incompatible substances. Avoid humid conditions because the glass-fiber reinforced PBT may absorb moisture. Stack securely and follow the manufacturer’s SDS and local regulations. |
| Shelf Life | Shelf life: 2 years under recommended storage conditions—cool, dry, sealed original packaging, away from direct sunlight and moisture. |
LONGLITE® PBT+GF 4815 is positioned in precision injection moulding for sealed underhood connector housings where a 15 wt% short-glass-fibre loading provides sufficient terminal-tang retention without the higher anisotropic shrinkage of 30 wt% PBT grades. Moulding operations for engine-compartment connectors require desiccant drying to a residual moisture value below 0.02 %, usually at 120–130 °C for 4 h; dryer dew-point control below −40 °C is checked at shift start and after material hopper changeovers. Barrel temperatures are set from 250 °C at the feed zone to 265 °C at the nozzle, while hot-runner manifold temperatures are held below 270 °C because PBT degrades under higher thermal load and releases tetrahydrofuran odour. A mould temperature of 70–90 °C is required to achieve surface crystallinity that passes USCAR-2 terminal-retention testing; cooling circuits are placed no more than 8 mm from gate-distant cavity corners because a cavity-to-cavity temperature spread exceeding ±5 °C produces post-mould shrinkage differences of more than 0.1 % in 24 h. Gate shear rates above 50,000 s−1 are avoided in pin-dense connector cavities because fibre breakage at thin-wall gates reduces weld-line strength. Screw back pressure is limited to 5–10 bar hydraulic to preserve fibre length; regrind use is generally capped at 20 % for OEM approvals and is not permitted on connectors with terminal retention after 1,008 h at 150 °C. Moulded parts are not released to assembly before post-shrinkage stabilisation measured by ISO 294-4:2018 at 23 °C/50 % relative humidity after 24 h.
| Standard / method | Test condition | Process control relevance |
|---|---|---|
| ISO 527-2 | 50 mm/min at 23 °C | Tensile strength and elongation at break |
| ISO 1183-1:2019 | Method A | Glass-fibre content verification after ashing |
| SAE USCAR-2 | 1,008 h at 150 °C | Terminal retention, no housing cracking |
| IEC 60695-2-11 | 750 °C glow wire for 30 s | No ignition or self-extinguish ≤ 2 s |
| ISO 294-4:2018 | 24 h after moulding | Shrinkage parallel and perpendicular to flow |
In high-RPM power tool motor end caps, insert retention becomes the controlling failure mode because the bearing boss is subject to cyclic radial load and vibration transmitted from the armature. The 15 wt% glass fibre in LONGLITE® PBT+GF 4815 reduces creep under radial load, but the moulding line must control the holding-pressure switch-over point to avoid premature gate freeze. A switch-over at 95–98 % part volume is used with hot-sprue bush sizes of 0.8–1.2 mm diameter; switching too early creates sink at the insert boss, while switching too late causes flash on bearing seats. Sintered bronze bushings and knurled steel inserts are pre-heated to 130–150 °C before placement because insert temperatures below 100 °C form a quenched interface that later separates under 3,000 min−1 no-load spindle speeds. Melt temperature is held at 255–270 °C, with a mould temperature of 80–90 °C to stabilise the crystalline structure around the insert. Packing pressure is maintained at 60–80 MPa for 3–5 s, followed by cooling time set by cavity-pressure sensors rather than timer-only control. Regrind is limited to 10 % for motor end caps certified to IEC 62841-1 because higher regrind fractions increase insert pull-out variance in tooling audits. End-of-line tests include ISO 179-1/1eA notched Charpy impact on moulded plaques and ISO 19095-2 adhesion evaluation on overmoulded metal-insert specimens. Failure modes recorded on production lines are boss micro-cracking after torque seating, insert rotation during armature removal, and white stress marks at gate regions after power tool drop tests.
Relay bases and coil bobbins use LONGLITE® PBT+GF 4815 when the electrical insulation system requires stable tracking behaviour under coil-impregnation varnish and a high-cavitation moulding process. The moulding specification normally calls for a 15 wt% glass fibre content, regrind restricted to 15 % maximum because the tracking index can fall when recycled granules carry degraded oligomers from screw dead spots. High-cavitation relay base tools with 32 or more cavities require hot-runner balance within 2 % of shot-weight coefficient of variation; unbalanced fill creates warpage after 24 h at 23 °C/50 % relative humidity that places coil pins outside their 0.05 mm position tolerance. Barrel temperatures are set at 250–260 °C and mould temperature at 70–85 °C; vent depths are maintained below 0.02 mm on the parting line to prevent flash while letting process gas escape from the glass-filled melt. Screw back pressure is held at 5–8 bar hydraulic and screw surface speed below 0.3 m/s to limit fibre breakage in the metering zone. Moulded relay bases are tested for dielectric strength by IEC 60243-1 and for end-product relay performance by IEC 61810-1; when the relay is used in reinforced insulation, the varnish compatibility test under UL 1446 is applied because solvents in impregnating resins can attack unstressed PBT surfaces and create micro-crazing. Coil bobbins wound with fine copper wire also require a gate vestige below 0.1 mm above the flange surface to prevent winding breakage at 0.05 mm wire diameters.
Because PBT+GF 4815 is not a hydrolysis-stabilised grade, its use in industrial sensor housings is confined to hydraulic oil and dry enclosure environments rather than alkaline washdown lines. The 15 wt% glass loading places tensile modulus in the range of 4,500–5,000 MPa by ISO 527-2, which is adequate for threaded manifold housings but not for high-bending-load spindle bodies. For overmoulding, brass inserts with knurled outer diameters are pre-heated to 140 °C and placed with a robot end-effector within 3 s to avoid surface cooling below 120 °C before injection. Melt temperature is set at 255–270 °C and mould temperature at 80–90 °C; holding pressure of 60–80 MPa is applied for 3–5 s to pack the thread root and eliminate sink marks that would compromise the O-ring groove floor. The gate is located behind the threaded boss, not on the sensor diaphragm face, because gate-induced fibre orientation creates non-uniform thermal expansion measured by ISO 11359-2. Laser welding of a PBT cover requires carbon black content below 0.2 wt% in the laser-transparent half; regrind is not used on the sealing half because black specks from carbonised resin produce weld voids. Oil-exposure validation is carried out by immersing moulded housings in hydraulic oil at 90 °C for 500 h and then checking retention torque on the insert, with acceptance set by the end-user drawing. The main incompatibility is continuous exposure to hot water-glycol mixtures above 85 °C, where ester hydrolysis causes a measurable drop in tensile strength before glass-fibre debonding becomes visible.
In domestic appliance contact blocks evaluated under IEC 60335-1, glow-wire resistance rather than tensile strength determines whether the moulding can pass the 750 °C end-product test. LONGLITE® PBT+GF 4815 is specified for live-part supports only when the design places the moulded surface outside the direct flame path and when the approval file lists the grade as UL 94 HB; for unshielded live parts requiring 850 °C glow-wire or V-0 flammability, a flame-retardant PBT compound is selected instead. Published data for LONGLITE® PBT+GF 4815 in this exact end-product geometry is limited, so appliance manufacturers validate the moulded part with the specific wall thickness, pigment package, and regrind level. A conservative ratio uses 15 wt% glass fibre and not more than 20 % regrind. Mould temperature is set at 70–90 °C to achieve a uniform crystalline surface; hot spots from poor cooling can reduce glow-wire ignition temperature because amorphous PBT skins degrade earlier. The moulded contact block is assembled with minimum creepage distances per the end-product standard and checked by IEC 60695-2-11 at 750 °C for 30 s.
Low-voltage battery management system signal connectors are moulded from PBT+GF 4815 when dimensional stability at elevated pack temperatures is more important than high-current thermal endurance. The 15 wt% glass loading provides connector mating force retention under 85 °C/85 % relative humidity testing because PBT absorbs significantly less moisture than polyamide 66, reducing pin-position shift after humidity exposure. Process settings follow a narrow window: desiccant drying at 120–130 °C for 4 h to below 0.02 % residual moisture, melt temperature 250–260 °C, mould temperature 80–90 °C, and an injection speed profile with a short initial fill burst to avoid gas traps around clipping features. Regrind is not permitted for BMS signal connectors that carry customer-mandated traceability lot numbers, and the glass-fibre content is checked by ashing to 15 ± 1 wt% per ISO 3451-1. Thermal shock validation follows IEC 60068-2-14 with air-to-air transfer between −40 °C and 105 °C, and a dwell of 30 min per extreme; after 48 cycles, terminal retention and latch function are inspected without removing the connector from the board fixture. Electrical clearance and creepage measurements are performed per IEC 60664-1 before and after the thermal shock sequence. Because no intrinsically flame-retardant claim is assumed without a colour-specific UL 94 V-0 listing, the application envelope is limited to signal-level circuits and is not used for high-voltage interconnects or locations where an isolation fault could bridge live parts. Moulded connectors are also evaluated for bias-humidity insulation resistance under 85 °C/85 % RH at 48 V DC per customer-specific LV 214 or USCAR-2 derivatives, with leakage current recorded at 1,000 h. The most common production-line failure is not material-related but mould-related: insufficient venting around the latch arm creates burn marks that trigger cosmetic rejection before electrical testing.
Competitive Chang Chun LONGLITE® PBT+GF 4815 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Chang Chun LONGLITE® PBT+GF 4815 is a 15 wt% glass-fiber-reinforced polybutylene terephthalate injection-molding compound carrying a flame-retardant package. The grade designation 4815 is the supplier-specific identifier for the filler loading and flame-retardant family; exact additive chemistry is provided only through lot-specific safety data sheets and processing certificates. The compound is supplied as cylindrical pellets with an apparent bulk density per ISO 60 typically in the range of 0.85–1.00 g/cm³. Primary processing is by injection molding for electrical connectors, relay bases, coil bobbins, terminal blocks, sensor housings, switch components, and similar electromechanical parts. The material is selected where wall thickness, flame retardancy, stiffness, and dimensional stability must be balanced without moving to a 30 wt% glass-fiber grade.
The intermediate filler content places LONGLITE® PBT+GF 4815 between unfilled PBT and 30 wt% glass-reinforced PBT in stiffness, flow length, and shrinkage anisotropy. Unfilled PBT grades typically show a tensile modulus near 2.5 GPa, while 30 wt% glass-fiber PBT can exceed 8 GPa. The 15 wt% glass level raises tensile modulus into the 4.5–6.0 GPa band, depending on fiber length retention after compounding and the orientation state frozen into the molded part. This intermediate stiffness reduces warpage in multi-pin connectors compared with higher filler loadings because longitudinal and transverse mold shrinkage converge. Yield tensile strength measured per ISO 527-2 is commonly reported between 85 MPa and 100 MPa; elongation at break remains below 4 % because the glass fibers restrict cold drawing. Notched Izod impact per ISO 180/1A is lower than unfilled PBT at sub-zero temperatures because of fiber-induced notch sensitivity, but room-temperature toughness is sufficient for press-fit and snap-fit features when gate placement avoids weld lines.
| Property | Unfilled PBT typical | LONGLITE PBT+GF 4815 | PBT+GF 30 typical | Test method |
|---|---|---|---|---|
| Density | 1.31 g/cm³ | 1.55 g/cm³ | 1.62 g/cm³ | ISO 1183-1 |
| Tensile stress at break | 55 MPa | 90 MPa | 120 MPa | ISO 527-2 |
| Tensile modulus | 2.6 GPa | 5.0 GPa | 8.5 GPa | ISO 527-2 |
| Notched Izod impact | 4.0 kJ/m² | 5.0 kJ/m² | 7.5 kJ/m² | ISO 180/1A |
| HDT/A at 1.8 MPa | 55 °C | 200 °C | 205 °C | ISO 75-1/-2 |
| Mold shrinkage | 1.8 % | 0.4–0.8 % | 0.2–0.4 % | ISO 294-4 |
| UL vertical flame classification at 0.75 mm | HB | V-0 | V-0 | UL 94 |
The above values are typical property ranges reported for short-glass PBT compounds in industrial datasheets; lot-specific certification values should be obtained from the manufacturer. Compared with LONGLITE PBT+GF 4815, a 30 wt% glass-filled PBT grade provides higher flexural modulus and better creep resistance but reduces melt flow, increases melt viscosity, and raises anisotropy in thin-wall parts. A flame-retarded unfilled PBT provides lower density and higher elongation but cannot maintain the same heat deflection temperature or load-bearing stiffness.
Lot-specific certificates for PBT+GF 4815 should be requested because flame-retardant glass-filled PBT compounds show measurable batch-to-batch variation in melt viscosity, color stability, and flame-retardant distribution. Flexural modulus per ISO 178 at 2 mm/min is frequently 15–25 % higher than tensile modulus because of the skin–core glass-fiber morphology. Tensile modulus per ISO 527-2 should be measured at 1 mm/min and tensile stress at break at 50 mm/min; results depend strongly on fiber orientation at the gate and should not be compared across different specimen locations. Heat deflection temperature per ISO 75-1/-2 Method A at 1.8 MPa is typically above 195 °C, reflecting the semicrystalline PBT matrix. Melt volume-flow rate per ISO 1133-1:2022 at 250 °C/2.16 kg is commonly specified in the 10–20 cm³/10 min range for this filler level, but exact flow data must be verified against the supplier release sheet because flame-retardant packages can shift melt rheology.
Volume resistivity measured per IEC 62631-3-1 after 48 h conditioning at 23 °C/50 % RH remains in the 1014–1016 Ω·cm range. Comparative tracking index per IEC 60112 is commonly specified at 250 V or higher for flame-retarded PBT, but exact CTI values for this grade are available only from the manufacturer because brominated flame retardants can lower tracking resistance relative to unfilled PBT. Dielectric strength per IEC 60243-1 on 1 mm plaques is typically in the 16–20 kV/mm range. These electrical properties should not be used as final insulation coordination data; creepage and clearance distances are defined by end-product geometry and pollution degree under IEC 60664-1.
Pre-drying in a desiccant dryer at 120 °C for 4 h to a residual moisture below 0.02 % is recommended before melt processing. PBT hydrolyzes at melt temperatures when moisture exceeds 0.03 %, reducing intrinsic viscosity and causing a measurable drop in tensile elongation at break. On production-scale injection molding machines with screw diameter of 30–45 mm and L/D ratio of 20:1 to 25:1, the melt temperature is maintained at 250–270 °C and the mold wall temperature at 60–80 °C. The mold temperature must remain above 60 °C to permit surface crystallization; below that threshold, post-mold crystallization can continue after ejection and alter dimensional stability. Injection pressure is normally 70–120 MPa, with hold pressure set at 60–80 % of peak injection pressure to reduce gate-stringing and fiber orientation gradients. Screw residence time should not exceed 10 min. Shutdown purging with a melt-stable polyethylene or acrylic purge compound is required to avoid black specks from degraded PBT accumulating in the barrel.
Long flow paths below 0.8 mm wall thickness require injection speeds of 80–150 mm/s screw advance and filling times below 0.5 s to prevent premature freeze-off. LONGLITE® PBT+GF 4815 flows sufficiently for thin-wall connectors, but it does not match high-flow unfilled PBT grades. Weld-line strength is a critical limitation: at converging flow fronts, glass fibers orient parallel to the weld plane, reducing weld-line tensile strength by 30–50 % relative to non-weld regions. Gate placement should therefore minimize the number of weld lines in load-bearing snap-fit features. Published industrial data for this specific configuration is limited, but failure analyses on multi-pin connector housings show crack initiation at weld lines when the mold temperature is below 60 °C and injection speed is low. Vent depth for semicrystalline PBT should not exceed 0.01–0.02 mm; vents must be cleaned at intervals of 500–1000 cycles when processing flame-retarded glass-filled grades because flame-retardant additives can plate out on mold vents.
Use of regrind above 20 wt% can reduce UL 94 V-0 consistency and notched impact strength due to fiber length reduction and non-uniform flame-retardant distribution. Production trials should set the maximum regrind fraction based on end-product flame and impact testing. For household appliances falling under IEC 60335-1, glow-wire flammability tests per IEC 60695-2-12 and IEC 60695-2-13 at 750 °C or 850 °C must be conducted on the final enclosure because wall thickness, contact pins, and part geometry change the thermal mass. The resin supplier’s UL 94 V-0 card is not a direct substitute for end-product certification. If halogen-free compliance is required, PBT+GF 4815 may not be suitable if its flame-retardant system relies on brominated chemistry; an alternative halogen-free PBT should be selected. Regulatory compliance with RoHS Directive 2011/65/EU and its amendments must be confirmed through the supplier’s material declaration because specific flame-retardant CAS numbers and recycled content can affect compliance status.