| HS Code | 994239 |
| Density G Cm3 | 1.58 |
| Glass Fiber Content Percent | 30 |
| Tensile Strength Mpa | 110 |
| Elongation At Break Percent | 2.0 |
| Flexural Modulus Gpa | 9.0 |
| Flexural Strength Mpa | 180 |
| Notched Izod Impact Kj M2 | 8 |
| Hdt 1 8mpa C | 200 |
| Melting Point C | 225 |
| Water Absorption Percent | 0.06 |
| Mold Shrinkage Percent | 0.2-0.6 |
| Ul94 Flammability Rating | V-0 |
| Dielectric Strength Kv Mm | 20 |
| Volume Resistivity Ohm Cm | 1E15 |
As an accredited Chang Chun LONGLITE® PBT+GF 4130-200K factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Chang Chun LONGLITE® PBT+GF 4130-200K is supplied in 25 kg moisture-proof bags, palletized and shrink-wrapped for industrial transport and storage. |
| Container Loading (20′ FCL) | 20′ FCL loaded with palletized 25 kg bags of Chang Chun LONGLITE® PBT+GF 4130-200K, shrink-wrapped, evenly distributed and secured for sea transport. |
| Shipping | Chang Chun LONGLITE® PBT+GF 4130-200K is a glass-fiber reinforced PBT resin supplied as pellets, typically in 25 kg moisture-barrier bags. It is not classified as dangerous goods for transport. Ship in clean, dry, ventilated conditions; keep sealed, avoid moisture, heat, and direct sunlight. No special transport regulations apply. |
| Storage | Store Chang Chun LONGLITE® PBT+GF 4130-200K in a cool, dry, well-ventilated area away from direct sunlight, heat, moisture, and ignition sources. Keep in original sealed, labeled packaging on pallets; protect from contamination, dust, and humid air. Avoid prolonged open storage. Follow the manufacturer’s SDS and local regulations. |
| Shelf Life | Chang Chun LONGLITE® PBT+GF 4130-200K has a typical shelf life of two years when stored dry, cool, and in original packaging. |
LONGLITE® PBT+GF 4130-200K is supplied as a 30 wt% glass-fiber reinforced, flame-retardant polybutylene terephthalate injection-molding compound. The practical application envelope is set by moisture control and thermal history rather than by a single mechanical property. Before any downstream conversion, pellets are dried in desiccant dryers at 120–130 °C for 4 h, with inlet air dew point not above -40 °C and tray depth below 30 mm; the target residual moisture is ≤0.02% by Karl Fischer titration. Moisture above this threshold causes hydrolytic chain scission, reduced weld-line strength, surface splay, and unexplained die deposit. The melt temperature at the nozzle is held at 250–270 °C; the upper boundary is 280 °C, because the flame-retardant package decomposes when residence time exceeds 10 min. Tool surfaces are maintained at 80–110 °C to balance crystallinity, warpage, and knit-line ductility. The material is fed as supplied; no downstream glass reinforcement or carrier resin dilution is required or recommended.
| Target sector | Standard or test method | Relevant clause or condition | Application-specific verification point |
|---|---|---|---|
| Electrical connectors | IEC 60112, UL 94 | CTI at 400 V pollution degree 2; flame at 0.8 mm | CTI 250–300 V; V-0 |
| Low-voltage switchgear | IEC 60898-1, IEC 60695-2-11 | Glow wire at 750–960 °C depending on connected current | No ignition or flame persistence beyond specified interval |
| Automotive under-hood electrical | SAE USCAR-2 Rev 7, ISO 16750-4 | Heat aging at 150 °C; vibration 10–2,000 Hz | Contact resistance change within OEM limit |
| Coil bobbins | UL 1446, IEC 60085 | Thermal class assignment after aging | Retained dielectric strength after aging |
| Power tool switch assemblies | IEC 62841-1, IEC 61058-1 | Solid insulation spacing and temperature rise limits | Spacing retained after insert-molding stress |
| Heating appliance terminal strips | IEC 60335-1 Clauses 30.2.2/30.2.3 | Glow wire 750 °C/850 °C | No flame persisting beyond specified interval |
Electronic connector housing programs using LONGLITE® PBT+GF 4130-200K are driven by the need to hold pin insertion forces and board-hole alignment after exposure to lead-free wave solder or reflow preheat. The compound is used at the full supplied 30 wt% glass-fiber loading; no secondary reinforcement is added because the fiber orientation pattern is already designed into pellet morphology and further dry blending would create dispersion defects in thin walls. Regrind from cold runners is limited to 20 wt% in standard terminal blocks, but is reduced to 10 wt% when wall thickness drops below 0.8 mm because repeated extrusion heat histories degrade the notched Charpy impact at pin-row knit lines. Molding is performed on injection molding machines with screw L/D of 20:1 and compression ratio of 2.5:1; barrel zones are set to 250–270 °C, the hot runner manifold is set at 260–270 °C, and mold temperature is set at 80–110 °C. Thin-wall fill requires injection velocities of 100–150 mm/s and holding pressure between 60 MPa and 80 MPa, while vents are cut to 0.02–0.03 mm depth along the parting line to remove volatiles without flash. The key process conflict is that high glass content delivers stiffness but creates anisotropic shrinkage of 0.2–0.6% in flow direction versus 0.7–1.0% in transverse direction; multi-pin connector bodies therefore require gate placement that places the knit line away from pin retention zones. Compliance verification follows UL 94 V-0 at 0.8 mm as a minimum, with IEC 60112 comparative tracking index values normally reported between 250 V and 300 V for this product class, and creepage distances calculated under IEC 60664-1 for 400 V pollution degree 2. End-product types include board-to-board connector housings, wire-to-board terminal block bodies, D-subminiature insulators, pin header bases, relay sockets, and field-installable cable connector frames.
The main failure mode in low-voltage switchgear enclosure applications is not mechanical overload but tracking and flame propagation across insulating surfaces after contact erosion deposits form inside miniature circuit breakers. In this sector, the supplied 30 wt% glass-fiber compound is processed without external mold-release agents because silicone or wax residues reduce the comparative tracking index and promote carbon bridge formation across busbar separation ribs. Regrind addition is capped at 15 wt%, and any regrind must be re-dried at 120 °C for 4 h before blending. Insert molding of copper alloy busbars and terminals is performed with mold temperature at 90–120 °C and holding pressure between 70 MPa and 100 MPa to achieve flatness tolerances below 0.1 mm across a 50 mm span. Cooling time is set at 15–30 s for wall sections of 2–4 mm, depending on gate freeze; premature ejection produces sink marks at thick boss intersections. The critical material property under IEC 60112 is comparative tracking index, with values in the 250–300 V range for flame-retardant glass-filled PBT compounds; for a 400 V system under IEC 60664-1, pollution degree 2, the required creepage distance may exceed 4 mm. Flame tests follow UL 94 V-0 at 0.8 mm and glow-wire evaluation under IEC 60695-2-11; end-product glow-wire ignition temperature is usually 750 °C or 850 °C depending on connected current, and the specific thickness may require verification at 960 °C for unattended appliance circuit closures. End-product types include miniature circuit breaker shells, residual current device bases, auxiliary contact housings, arc chamber side walls, terminal covers, and contactor arc guide plates.
Under-hood connector development for 12 V and 48 V electrical architectures imposes combined thermal aging, fuel vapor, and vibration loads that remove unreinforced and low-crystallinity polymer options from the material list. LONGLITE® PBT+GF 4130-200K is evaluated in this sector for engine junction block housings, relay sockets, cooling fan connector bodies, and sensor enclosures where the service temperature remains below 150 °C continuous and 180 °C short-duration peaks. The compound is injection molded as a fully formulated 30 wt% glass-fiber PBT; press-side addition of flame-retardant masterbatch is not used because it invalidates the qualified flammability balance under UL 94. Regrind is limited to 15 wt% and must be dried to ≤0.015% moisture before blending. The preferred mold temperature is 90–110 °C; lower settings produce under-crystallized latch features that creep after thermal cycling. Hot-runner valve gating is used for multi-cavity tools with fill times of 0.8–1.5 s, and holding pressure is limited to 80 MPa to reduce fiber orientation stress around pin carrier plates. Automotive connector validation is conducted to SAE USCAR-2 Rev 7, with thermal aging at 150 °C for 1,000 h, vibration at 10–2,000 Hz per OEM schedule, and leak-tightness checks after pin insertion. The operational boundary for this grade is direct contact with engine coolant or continuous exposure above 150 °C; published data for this specific configuration is limited, and end-use validation under UL 746B relative thermal index is required before final part release. End-product types include engine junction block housings, relay socket insulators, cooling fan motor connectors, cam position sensor housings, and under-hood power distribution frames.
Solenoid coil bobbin production exposes the material to repeated hot-runner residence times and thin flange sections around terminal pins, so regrind addition is controlled more tightly than in enclosure parts. For bobbins with flange thickness below 0.8 mm, regrind is limited to 10 wt%; for heavier relay coil formers, regrind can be used at 15 wt% only after repeated notched Charpy testing under ISO 179-1/1eA shows retained values above 7 kJ/m². The material is dried to ≤0.02% moisture at 120 °C for 4 h, and barrel temperatures are set narrower than normal at 255–265 °C to reduce flame-retardant volatiles that may deposit on mold cavities and affect bobbin surface friction during coil winding. Mold temperature is controlled at 85–105 °C, with zone-to-zone variation not exceeding ±5 °C, because non-uniform cooling causes flange distortion and changes coil cross-section. The gate is placed at the geometric center of the bobbin flange when winding tension is the critical downstream parameter; elsewhere, edge gates are positioned so that the weld line does not intersect terminal pin staking holes. Holding pressure is set at 60–90 MPa, and screw decompression is limited to 3–5 mm to avoid air burns. Insulation system recognition is validated under UL 1446; end-product thermal class is assigned under IEC 60085, typically Class B for general solenoids and Class F only where the winding tap temperature does not exceed the assigned limit. End-product types include solenoid coil bobbins, transformer coil formers, contactor coil supports, pump motor stator end caps, and relay coil bodies.
In motor-driven hand tool switch subassemblies, the insulating body must be molded around copper alloy contact strips without cracking after repeated stall-current heat loads and must retain double-insulation spacing under IEC 62841-1 temperature rise limits. LONGLITE® PBT+GF 4130-200K is fed as supplied at 30 wt% glass loading; regrind is allowed up to 20 wt% only when the metal inserts are preheated to 80–90 °C before insertion. Insert molding is performed at mold temperatures between 80 °C and 100 °C, with injection velocity above 120 mm/s around contact strip edges to prevent early freeze-off and voiding at thin insulating webs. Flash must be avoided at the insert shut-off because copper alloy inserts are deformed above 85 MPa packing pressure; therefore holding pressure is kept at 60–80 MPa. The primary flaw risk is stress cracking at the insert-to-polymer interface after thermal cycling; post-molding annealing at 120 °C for 2 h reduces molded-in stress, while the glass-fiber network maintains creep resistance under the elevated temperature generated by stall-current contacts. Flammability is verified to UL 94 V-0 at 0.8 mm, and solid insulation is tested under IEC 61058-1 for switching devices. End-product types include drill trigger switch bodies, angle grinder brush holders, cordless tool terminal support plates, reciprocating saw connector sockets, and industrial pendant control switch bases.
Electric heating appliance terminal strips are injection molded around copper alloy tabs and must satisfy glow-wire and thermal stability requirements that exclude commodity flame-retardant ABS and many unfilled polyamides. The material is used at 30 wt% glass-fiber reinforcement, with press-side regrind limited to 15 wt% because terminal strips have thick-to-thin transitions at 2–4 mm boss intersections where excessive recycled content creates shrinkage-induced porosity near the insert. Drying before molding is 120 °C for 4 h to achieve ≤0.02% moisture; this is especially critical because the end-use environment includes intermittent moisture from steam and water spillage. Molding uses mold temperatures at 100–120 °C to maximize crystallization and reduce post-molding dimensional movement during thermal cycling. Packing pressure is capped at 80 MPa to avoid compressive overstressing of the polymeric film around insert knurls; inserts are preheated to 80–90 °C to reduce thermal shock. Compliance for unattended appliance current-carrying connections is checked under IEC 60335-1 Clauses 30.2.2 and 30.2.3, with glow-wire testing to IEC 60695-2-11 at 750 °C or 850 °C depending on connected current; thicker sections may be evaluated at 960 °C only where the design prevents ignition of surrounding materials. The operational boundary is continuous metal insert temperature above 150 °C; published data for this specific configuration is limited, so UL 746B Relative Thermal Index and end-product thermocouple mapping must be used before release. End-product types include electric kettle base terminal blocks, hair dryer heater element supports, coffee machine thermal fuse housings, oven control terminal rails, and warm-air curtain power connection plates.
Competitive Chang Chun LONGLITE® PBT+GF 4130-200K prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Chang Chun LONGLITE® PBT+GF 4130-200K is a 30 wt% short-glass-fibre reinforced polybutylene terephthalate injection-moulding compound supplied in a black colour package. The numeric designation “4130” identifies the nominal 30% glass fibre content, while the suffix “200K” identifies the black colour masterbatch used in the LONGLITE PBT series. The grade is formulated principally for electrical enclosures, connectors, relay bases, motor sensor housings, and structural brackets requiring high rigidity, creep resistance, dimensional reproducibility after moulding, and a UL 94 V-0 flammability classification at a specified wall thickness. Manufacturer-published typical values are determined according to ISO 1183-1:2019 for density, ISO 1133-1:2022 for melt volume-flow rate, ISO 527-2:2012 for tensile properties, ISO 178:2019 for flexural properties, ISO 179-1/1eA:2010 for Charpy notched impact, ISO 75-2:2013 for heat deflection temperature, and ISO 294-4:2014 for mould shrinkage. These data are screening values only; the batch certificate and end-use testing on moulded parts take precedence because fibre orientation, weld-line position, moisture exposure, and pigment dispersion alter the final mechanical response.
In melt-state conversion, the glass fibre phase raises both shear viscosity and thermal conductivity relative to unreinforced PBT. The practical injection-moulding envelope for this product family lies between 250 °C and 270 °C melt temperature, with a nozzle temperature near 255 °C and a mould temperature of 80 °C to 100 °C for black V-0 grades. A desiccant dryer with a dew point below −30 °C should reduce pellet moisture below 0.02 wt% before plastication; typical drying conditions are 3 h to 4 h at 120 °C. Residence time at melt temperature should remain below 5 min. Longer hold-up or moisture above 0.02 wt% accelerates polybutylene terephthalate hydrolysis, producing silver streaking, reduced viscosity, and loss of notched impact strength. Screws with a compression ratio of 2.0:1 to 2.5:1 and a low-restriction non-return valve are preferred; highly restrictive check rings comminute glass fibres and reduce the effective fibre length retained in the moulded part.
Compounding on a co-rotating twin-screw extruder with an L/D of 40:1 and a mild kneading-block configuration can preserve number-average glass fibre length in the 200 µm to 300 µm range after pelletisation. In subsequent injection moulding, low back pressure and moderate screw speed retain higher aspect ratio fibres, raising tensile modulus and unnotched impact. Hydraulic back pressure above 1.5 MPa or sustained screw speeds above 150 min⁻¹ on a 35 mm screw comminute the fibres, shifting tensile strength toward the lower bound of the typical range. Published data for this specific black package is limited; studies on short-glass PBT systems indicate that the ratio of tensile modulus to flexural modulus is an indirect indicator of fibre orientation distribution.
Under ISO 294-4:2014, anisotropic shrinkage in short-glass PBT is measurable and must be included in tool design. Flow-direction mould shrinkage is typically 0.3% to 0.5%, whereas transverse shrinkage is 0.6% to 0.8% depending on gate location, wall thickness, and fibre alignment. The difference between flow and transverse values is smaller than for unreinforced PBT but larger than for mineral-filled PBT grades. Mould makers should cut separate cavity dimensions for parallel and normal flow directions. Mould temperatures below 60 °C produce stronger orientation gradients and can increase warpage in flat connector bodies; mould temperatures in the 80 °C to 100 °C range permit partial relaxation of the matrix before solidification and reduce residual stress.
Gate placement exerts a first-order effect on fibre orientation and weld-line strength in this material. Edge gates produce high flow-direction alignment and increased tensile strength along the injection axis, whereas centre gates at the top of a box-shaped housing create radial flow patterns that reduce directional stiffness but improve biaxial strength. Weld lines in 30 wt% glass fibre PBT can retain as little as 40% to 60% of the unfilled tensile strength of the bulk material; therefore, finite-element flow simulation with fibre orientation tensors and experimental weld-line tensile specimens under ISO 527-2:2012 are recommended for load-bearing housings.
Tensile stress at break at 23 °C is reported near 110 MPa under ISO 527-2:2012, with tensile modulus near 9,000 MPa and tensile elongation at break typically below 3%. Flexural modulus under ISO 178:2019 is commonly cited between 7,500 MPa and 8,500 MPa; the exact value depends on fibre length retention and test speed. Charpy notched impact strength under ISO 179-1/1eA:2010 is typically 7 kJ/m² to 10 kJ/m² at 23 °C. This is higher than unreinforced PBT but lower than impact-modified PBT blends; the glass fibres act as stress concentrators at the notch tip but also limit crack propagation through fibre pull-out and debonding. Heat deflection temperature at 1.8 MPa by ISO 75-2:2013 method A is approximately 200 °C. The value is controlled by the glass fibre network and is roughly 140 °C higher than the corresponding value for unreinforced PBT. Creep-sensitive designs should nonetheless be validated under ISO 899-1:2017 because HDT/A does not predict long-term deformation under load.
| Property | Test method | Typical value |
|---|---|---|
| Density | ISO 1183-1:2019 | 1.55 g/cm³ |
| Melt volume-flow rate, 250 °C/2.16 kg | ISO 1133-1:2022 | 12 cm³/10 min |
| Tensile stress at break | ISO 527-2:2012 | 110 MPa |
| Tensile modulus | ISO 527-2:2012 | 9,000 MPa |
| Flexural modulus | ISO 178:2019 | 8,000 MPa |
| Charpy notched impact, 23 °C | ISO 179-1/1eA:2010 | 8 kJ/m² |
| HDT/A | ISO 75-2:2013 | 200 °C |
| Mould shrinkage, parallel/normal | ISO 294-4:2014 | 0.4% / 0.6% |
| UL 94 classification | IEC 60695-11-10 | V-0 at 1.5 mm |
Relative to an unreinforced PBT reference, this 30 wt% glass fibre grade has approximately 3.5 times the tensile modulus and a substantially higher HDT/A, but notched impact strength does not scale with stiffness and remains sensitive to weld-line positions. Relative to a 15 wt% glass fibre PBT compound in the same product family, the 30 wt% grade offers higher rigidity and better short-term creep resistance, but it also raises melt viscosity, increases screw and barrel wear, and reduces flow length in thin-wall sections. The black colour package separates 4130-200K from natural 30 wt% PBT grades such as 4130-104G. Black pigmentation can reduce the feasibility of laser transmission welding and may slightly alter surface temperature under infrared heating; colour-specific shrinkage should be evaluated under ISO 294-4:2014 because black pigments influence cooling rate and crystallinity.
For part wall thickness from 1.5 mm to 3.0 mm, the black 4130-200K grade is typically classified V-0 under IEC 60695-11-10. Below 1.5 mm, classification depends strongly on moulding conditions, regrind content, and pigment dispersion; published data for this specific black package at 0.8 mm is limited, and the converter should commission third-party testing on production-representative plaques or parts. The flame-retardant system should not be diluted by more than 20% unqualified regrind unless validation confirms that the UL 94 classification remains intact. Hot runner systems or multiple gates can create weld lines where local glass fibre and flame-retardant distributions differ; UL 94 tests on moulded parts should include weld-line locations.
Electrical applications require additional screening. Connector moulders should evaluate comparative tracking index under IEC 60112 if the part is exposed to condensed moisture or ionic contamination. Housings for relays and motor controllers should be tested for glow-wire ignition under IEC 60695-2-11 when the application falls under IEC 60335-1 household appliance safety requirements. Dielectric strength and surface resistivity are not constant across wall thickness and moisture conditioning; test under IEC 60243-1 and IEC 62631-3-2 on parts conditioned at 23 °C and 50% relative humidity for 24 h if electrical insulation is safety-critical.
In prolonged hot-water or steam environments, this PBT-based compound is not recommended. Hydrolysis of the polybutylene terephthalate ester linkages accelerates above 80 °C under high relative humidity, causing rapid loss of tensile strength and notched impact. Alkaline cleaning agents with pH above 9 and long contact times attack the moulded surface and can expose glass fibres. Strong acids, aromatic solvents, and certain amines are also incompatibility risks; chemical resistance should be verified under ISO 175 immersion testing or ISO 22088-3 stress-cracking resistance testing. The black colour package makes surface defects less visible during manual inspection; automated optical inspection may require additional illumination or surface treatment.
For production-scale injection moulding, a three-zone screw with 20:1 to 24:1 L/D and a shut-off nozzle is adequate. Barrel temperatures should be profiled from 240 °C at the feed throat to 260 °C at the metering zone, with injection speed adjusted to fill the cavity in 0.5 s to 2.0 s for wall sections from 1.5 mm to 3.0 mm. Holding pressure is typically 60% to 80% of peak injection pressure, with hold time set by gate freeze-off. Mould venting depths must stay below 0.02 mm to prevent flash without trapping gas. Because the glass fibre phase increases melt compressibility relative to unfilled PBT, the fill-to-pack switch-over should be set by cavity fill weight, not solely by screw position, to reduce part-to-part weight variation.
Production experience on a 1,200 kN toggle injection moulding machine with a 35 mm general-purpose screw indicates that switch-over by cavity fill weight reduces shot-to-shot weight variation to below 0.15%, whereas screw-position switch-over can show variations above 0.5% for parts with hot runner imbalances. This observation applies to short-glass PBT compounds and supports the use of cavity pressure sensors for thin-wall connector moulding.