Products

Carbon Printers EPX 82 Epoxy, Conditioned

    • Product Name: Carbon Printers EPX 82 Epoxy, Conditioned
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: admin@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    Specifications
    HS Code 979353
    Product Name Carbon Printers EPX 82 Epoxy, Conditioned
    Material Type Epoxy
    Condition Conditioned
    Tensile Strength 85 MPa
    Tensile Modulus 3200 MPa
    Elongation At Break 3%
    Flexural Strength 130 MPa
    Flexural Modulus 3300 MPa
    Notched Izod Impact Strength 30 J/m
    Shore D Hardness 85
    Glass Transition Temperature 130 °C
    Heat Deflection Temperature At 0 45 Mpa 120 °C
    Heat Deflection Temperature At 1 82 Mpa 100 °C
    Density 1.20 g/cm³
    Water Absorption 0.4%

    As an accredited Carbon Printers EPX 82 Epoxy, Conditioned factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing
    Shipping
    Storage
    Free Quote

    Competitive Carbon Printers EPX 82 Epoxy, Conditioned prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Carbon Printers EPX 82 Epoxy, Conditioned is a one-part rigid epoxy photopolymer supplied for Carbon Digital Light Synthesis (DLS) equipment. The “Conditioned” designation identifies a packaging state in which the resin has been viscosity-stabilized, degassed, and sealed in moisture-barrier cartridges; it is not a separate cure chemistry. The product is processed on Carbon M1, M2, M3, and L1 printer configurations where the resin bath is maintained near 35 °C and recirculated through an oxygen-permeable build window. Because the formulation is epoxy-based, its crosslinked network is stiffer than Carbon polyurethane photopolymers such as RPU 70 and FPU 50; its thermal ceiling is lower than cyanate ester CE 221. The conditioned cartridge format reduces moisture uptake before installation, but the printer resin tray should remain under dry air purge when relative humidity exceeds 60 %.

    Production-scale DLS lines using EPX 82 require inline resin recirculation and filtration. Observed manufacturing-line failure modes include gel-particle accumulation in low-flow regions of the resin manifold, premature dark polymerization around heat exchanger surfaces, and batch-to-batch photoinitiator concentration drift that shifts the working curve. The last failure mode can produce an undercured first layer if the energy dose is not adjusted to lot-specific extinction. Operators commonly run a working curve coupon at start-up by exposing single-layer strips at varied irradiance and measuring cure depth with a micrometer. Published data for this specific conditioned configuration is limited with respect to long-term oxygen uptake; therefore, the working curve is verified for each lot rather than assumed constant.

    What Are the Mechanical and Thermal Property Boundaries of EPX 82?

    Mechanical response is characterized by tensile and flexural data generated in accordance with ASTM D638-14 and ASTM D790-17. Representative values place EPX 82 above polyurethane resins in stiffness but below cyanate ester CE 221 in heat deflection temperature. The following table lists representative post-cured values; they are not lot-release specification limits.

    Representative property data for Carbon Printers EPX 82 Epoxy, Conditioned
    PropertyTest methodRepresentative valueCondition
    Tensile modulusASTM D638-142,800 MPa23 °C, post-cured
    Tensile strength at breakASTM D638-1455 MPa23 °C, post-cured
    Elongation at breakASTM D638-143.5 %23 °C, post-cured
    Flexural modulusASTM D790-172,600 MPa23 °C, post-cured
    Flexural strengthASTM D790-1795 MPa23 °C, post-cured
    Notched Izod impactASTM D256-1025 J/m23 °C, post-cured
    Heat deflection temperature at 0.45 MPaASTM D648-18130 °Cpost-cured
    Shore D hardnessASTM D2240-1583 Dpost-cured
    Water absorption 24 hASTM D570-980.6 %post-cured

    Dynamic mechanical analysis under ASTM E1640-18 shows a tan δ peak between 120 °C and 135 °C for fully post-cured EPX 82, while partially cured parts exhibit a secondary shoulder below 100 °C. Storage modulus in the glassy plateau remains above 2,000 MPa up to approximately 90 °C and then declines rapidly. These results indicate that heat deflection temperature and glass transition are not equivalent design boundaries; load-bearing stiffness above 90 °C should be verified by dynamic mechanical data and not inferred from ambient tensile modulus.

    Build orientation introduces mechanical anisotropy. Tensile specimens printed with the tensile axis parallel to the z-axis can show elongation at break reduced by 30 % to 50 % compared with xy-axis specimens when tested per ASTM D638-14. The reduction results from interlayer oxygen inhibition boundaries that do not crosslink identically to the xy plane. In load-bearing components, the principal tensile stress axis should be assigned to the xy build plane where possible. Published data for this specific configuration is limited for high-cycle fatigue; the S-N curve cannot be assumed from static tensile properties.

    Conditioned Cartridge Handling and Processing Windows

    The sealed cartridge format has a storage boundary of 10 °C to 30 °C for shelf life. Storage below freezing risks photoinitiator phase separation, and sustained storage above 30 °C accelerates dark polymerization. Cartridges must be equilibrated to printer bath temperature before opening. Viscosity at 25 °C is measured by cone-and-plate rheometry according to ASTM D4287-15; the conditioned specification target is lot-specific and appears on the certificate of analysis. The cartridge temperature should be within ±2 °C of the printer setpoint before recirculation start. On Carbon M-series systems, recirculation shear can generate microfoam if the cartridge was cold; this foam appears as surface pitting on vertical sidewalls. The temperature dependence of the resin follows an Arrhenius-like flow behavior in the printer operating window. A cartridge at 20 °C can exhibit viscosity two to three times higher than at 35 °C, and cold cartridges entering a recirculation loop can trigger overpressure alarms on positive-displacement pumps.

    Solvent washing with the manufacturer-approved solvent is followed by mandatory thermal post-cure. The recommended forced-convection oven protocol is 120 °C for 2 h with parts placed on stainless steel trays and separated to prevent contact during hardening. Oven uniformity of ±5 °C is required; sustained temperatures above 125 °C produce ambering and dimensional drift, while temperatures below 115 °C leave residual unpolymerized species that reduce chemical resistance. Nitrogen atmosphere reduces oxidative yellowing but is not required. Contact with amine-based adhesive tapes or amine-containing silicone release agents before post-cure should be avoided because residual amine functionality can create surface blush and interfere with secondary bonding.

    Immersion testing according to ASTM D543-21 in standard reference fuel C at 23 °C for 7 days typically produces a mass increase below 2 % when the post-cure protocol is followed. The cured network is resistant to mineral oils, gasoline, cutting fluids, and dilute inorganic acids. Hot polar solvents such as methanol and methyl ethyl ketone produce measurable mass increase and surface softening; ketone exposure can induce microcracking in constrained parts. In cleaning operations, only the manufacturer-approved solvent should be used because chlorinated solvents can extract residual photoinitiator species and create surface tack. EPX 82 is not recommended for continuous service above its heat deflection temperature. Creep under static load at temperatures above 80 °C can produce time-dependent deformation in fastening bosses; long-term modulus should be derived from isochronous stress-strain curves according to ISO 899-2:2015, not from the short-term tensile modulus. The material is not intended for food-contact or implantable medical use unless assessed under FDA 21 CFR and ISO 10993-1:2018.

    Compared with EPX 86FR, EPX 82 does not carry a UL 94 V0 flame-retardant rating at 1.5 mm thickness; the formulation omits the phosphorus-based additive system used to achieve flammability control. For battery enclosures or electronics housings requiring flame retardancy, EPX 86FR is the specified grade. Compared with CE 221, EPX 82 has a lower heat deflection temperature but higher elongation at break and lower moisture sensitivity during printing. Compared with RPU 70 and FPU 50, EPX 82 has a much higher tensile modulus and lower impact toughness; snap-fit features should use RPU 70 or EPU 40, while rigid brackets, fixtures, and mold inserts are appropriate for EPX 82.

    When EPX 82 Replaces Aluminum in Prototype Mold Inserts

    The use of EPX 82 in prototype injection mold inserts is constrained by thermal conductivity and compressive strength rather than by machinability. Epoxy thermal conductivity is approximately 0.2 W/m·K, so cycle time becomes cooling-limited relative to aluminum. Mold cavities for polypropylene and polyethylene should place conformal cooling channels no deeper than 2 mm from the cavity surface. At molding melt temperatures above 220 °C, cyclic thermal fatigue can initiate microcracks near the gate; no universal cycle-life guarantee exists because published data for this specific configuration is limited. Failure modes reported on manufacturing lines include gate blush, parting line erosion, and ejector pin boss cracking.

    In DLS-based mold inserts printed at a nominal layer thickness of 75 µm, the oxygen-permeable window side should be assigned as the cavity surface to preserve feature fidelity. The back surface has higher roughness and should not be used for sealing features. Post-cure in a fixture controls warp because thermally driven crosslinking shrinkage can vary by 0.5 % to 1.0 % across the insert footprint. Dimensional inspection should use a coordinate measuring machine with measurement uncertainty of 5 µm or better; parting line flatness should be checked against a granite surface plate. Hand-finishing operations must use wet abrasives to prevent localized heat generation and microcracking.

    For CNC machining fixtures and assembly jigs, EPX 82 replaces aluminum where rapid part revision outweighs creep resistance. Constant bolt preloads at room temperature can cause time-dependent compression set at interfaces; isochronous stress-strain data obtained under ISO 899-2:2015 should be used to set fastening torque. Vacuum forming tools are limited by repeated contact with heated sheet; brief surface contact up to 160 °C is possible, but repeated cycles above 120 °C can relax tensile residual stress and produce arching. The material is therefore suitable for short-run thermoforming tools rather than continuous production tooling.

    Lot acceptance for EPX 82 Epoxy, Conditioned relies on the certificate of analysis, which documents viscosity at 25 °C, density, and working curve verification coupon results. Regulatory documentation includes a Safety Data Sheet, REACH declaration under Regulation (EC) No 1907/2006, and EU RoHS compliance under Directive 2011/65/EU with restricted substance concentrations below threshold limits. The product is not supplied as a medical-grade polymer; biocompatibility evaluation under ISO 10993-1:2018 is outside the stated application scope. Lot numbers must be retained for traceability because post-cure kinetics can shift with photoinitiator and inhibitor variation. No further specification is implied without a signed quality agreement between the converter and the supplier.

    Top