Products

Carbon Printers 3D Print Resin 385nm

    • Product Name: Carbon Printers 3D Print Resin 385nm
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: admin@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    Specifications
    HS Code 288294
    Brand Carbon Printers
    Product Name 3D Print Resin 385nm
    Product Type UV-curable photopolymer resin
    Curing Wavelength 385 nm
    Compatible Printer Types SLA, DLP, and LCD 3D printers that use a 385 nm light source
    Color Grey
    Net Weight 1 kg
    Density Approximately 1.10 g/cm³
    Viscosity Approximately 200-400 mPa·s at 25°C
    Shore Hardness Approximately 80-85 D
    Tensile Strength Approximately 45-55 MPa
    Elongation At Break Approximately 5-10%
    Flexural Strength Approximately 70-80 MPa
    Flexural Modulus Approximately 2000-2500 MPa
    Heat Deflection Temperature Approximately 80°C
    Layer Thickness 0.025-0.1 mm
    Shelf Life 12 months from date of manufacture when stored properly
    Storage Conditions Store in a cool, dry, dark place between 15°C and 30°C, away from UV light
    Odor Low acrylic odor
    Post Curing Requires UV post-curing, typically with 405 nm or broad-spectrum UV light

    As an accredited Carbon Printers 3D Print Resin 385nm factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing
    Shipping
    Storage
    Free Quote

    Competitive Carbon Printers 3D Print Resin 385nm prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Carbon Printers 3D Print Resin 385nm is a liquid acrylate/methacrylate photopolymer formulated for vat photopolymerization equipment using a 385 nm peak-wavelength LED, DLP, or Carbon Digital Light Synthesis light engine. The resin is distinguished from 405 nm materials by the shorter wavelength photochemistry: at 385 nm, photon energy is approximately 3.22 eV versus 3.06 eV at 405 nm, which alters initiator selection, depth of cure, and surface conversion. Typical formulations contain urethane acrylate or epoxy acrylate oligomers, monofunctional and difunctional reactive diluents, an acylphosphine oxide photoinitiator package such as diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide or phenylbis(2,4,6-trimethylbenzoyl)phosphine oxide, and additive packages for pigment dispersion, wetting, and oxygen-mediated dead-zone control. The liquid density for this product class is commonly reported in the range of 1.05–1.15 g/cm³ at 25 °C according to ISO 1183-1:2019, and rotational viscosity measured with a Brookfield viscometer per ASTM D2196-20 falls between 250 mPa·s and 700 mPa·s. The cured-material property envelope for a rigid grade after post-cure is typically tested according to ASTM D638-14, ASTM D790-17, ASTM D256-10, and ASTM D648-18; exact lot-specific values are stated on the supplier certificate of analysis, and published data for this specific configuration is limited where proprietary pigment or stabilizer packages are present.

    385 nm Cure Window and Free-Radical-Acrylate Kinetics

    Photoinitiator response at 385 nm is dominated by acylphosphine oxide photolysis. The free-radical generation rate is a function of incident irradiance, spectral overlap, and initiator concentration; once the surface initiator concentration exceeds 1.5 wt%, depth of cure may fall sharply because the resin becomes optically dense at the working wavelength and incoming photons are consumed in the first 20–40 µm of the layer. This is a distinguishing constraint for 385 nm systems compared with 405 nm systems, where longer-wavelength initiator absorptivity is usually lower and penetration depth is higher. The Jacobs working curve is used to define the minimum exposure energy required for adhesion to the previous layer: Cd = Dp · ln(E0/Ec), where Cd is cure thickness, Dp is penetration depth, E0 is incident energy dose, and Ec is critical energy dose. For clear rigid grades, published working curves commonly place Dp between 120 µm and 180 µm and Ec between 8 mJ/cm² and 20 mJ/cm² at 385 nm. Pigment loading, especially carbon black or titanium dioxide, can increase Ec by a factor of 1.5–3.0 and must be compensated by longer exposure per layer or higher light intensity.

    At low irradiance below 1 mW/cm², the cure front may not reach the intended depth because oxygen influx consumes radicals faster than they are generated. Production-scale failure signatures include interlayer delamination, edge cupping, and soft bottom surfaces on the build platform side. The resin temperature further modifies cure response because viscosity falls with increasing temperature, and the monomer diffusion rate into the polymerisation front rises. A resin conditioned at 30 °C commonly exposes faster than the same lot at 18 °C by 10–20 % for a given layer thickness, though the exact shift is machine- and lot-specific and must be confirmed by a working-curve calibration.

    On the build platform, the resin is conditioned at 25–30 °C before the vat is filled, and low-shear recirculation is maintained through a 10–50 µm filter to remove cured debris. Layer thickness is set between 25 µm and 100 µm. For Carbon M1 and M2 Digital Light Synthesis systems, the oxygen-permeable window maintains a polymerisation-inhibited dead zone of roughly 20–50 µm, which prevents the first cured layer from bonding to the optical window. The dead-zone thickness is affected by oxygen permeability, resin photoinitiator concentration, incident irradiance, and temperature; resin lots with viscosity above 700 mPa·s may require heated vat operation or longer recoating time between layers. Exposure time per layer is derived from the working curve and the measured build-plane irradiance, which for 385 nm LCD/DLP systems is typically 1–5 mW/cm². At 50 µm layer thickness and 2 mW/cm² measured irradiance, a clear resin with Ec of 12 mJ/cm² and Dp of 150 µm may require an incident dose of approximately 18–25 mJ/cm², corresponding to 9–13 s exposure per layer after adhesion overcure is included; however, this must be confirmed on the target machine because optical path losses, window haze, and resin temperature shift the actual cure response.

    Recoating in high-viscosity lots is a bottleneck on high-throughput lines. When a 25 µm layer is formed on a resin with viscosity above 500 mPa·s, resin drainage time can exceed 10 s per cycle if the build plate diameter is large or if the resin contains denser fillers such as silica or alumina. Actual manufacturing platforms therefore use heated vats, blade recoating, or delay loops to prevent layer starvation. Batch-to-batch variation in monomer ratio, inhibitor level, and pigment dispersion also changes the working curve; incoming lots are qualified on a representative calibration part before production release.

    Why Does Oxygen Inhibition Alter Surface Conversion at the Dead Zone Interface?

    Oxygen is a strong inhibitor of free-radical acrylate polymerisation because ground-state triplet oxygen reacts with propagating carbon-centred radicals at rates near diffusion control, generating peroxyl radicals that terminate chains. In vat photopolymerization at 385 nm, the oxygen-permeable membrane deliberately maintains a thin, uncured region at the build interface; below this dead zone, oxygen concentration falls and the polymerisation front propagates once the incident dose exceeds Ec. The surface of the final part, however, remains oxygen-inhibited and may exhibit tack if the layer is the last one cured. Fourier-transform infrared attenuated total reflectance spectroscopy of an uncured layer typically monitors the acrylate C=C twisting vibration near 810 cm−1; after post-cure, residual conversion increases and the absorption peak decreases. Oxygen inhibition also requires a 20–50 % increase in exposure dose for the first burn-in layers to compensate for the high oxygen flux at the window interface. Formulations that contain amine synergists are generally avoided because amine-based additives can migrate to the interface and generate measurable yellowing or premature dark reaction, shifting the working curve and reducing shelf stability.

    Post-cure in a 385–405 nm flood chamber is conducted at an irradiance of 2–5 mW/cm² and a part-surface temperature of 60 °C for 20–60 min, depending on cross-section and mass. A nitrogen blanket at 2–5 L/min reduces oxygen inhibition during the first 10 min of post-cure; without inerting, the part surface can remain underconverted and exhibit reduced hardness according to ASTM D2240-15. The post-cure step raises tensile strength and heat deflection temperature but can reduce elongation at break because additional crosslinking shifts the network structure into a denser, more brittle state. For a rigid 385 nm grade, tensile bars post-cured at 60 °C for 30 min under 3 mW/cm² may reach tensile strength values in the 45–65 MPa range when tested according to ASTM D638-14, while an under-cured batch may remain below 40 MPa and exhibit measurable flexural creep at 0.455 MPa according to ASTM D648-18. Lot release testing is performed on Type IV specimens conditioned at 23 °C and 50 % RH for 24 h; specimens are measured with a calibrated universal testing machine equipped with an extensometer, and the strain rate is set to 5 mm/min for tensile testing.

    Incoming resin lots are inspected by rotational viscometry, FTIR-ATR, and a standardized cure-depth test on a glass slide using a 385 nm LED source at a fixed energy dose. The cure-depth test is compared against the supplier working curve; if the measured Dp deviates by more than ±15 %, the lot is rejected or the exposure recipe is compensated. Contaminants from heated vat elements or from metal build platforms can accelerate radical generation or cause localized gelation; stainless steel 316L build plates are generally compatible, but unpainted aluminum surfaces may release ions that shift inhibitor consumption. Storage is specified at 15–30 °C in sealed polyethylene or polypropylene containers with headspace purged of oxygen, and exposure to ambient light below 450 nm must be minimized. The uncured resin is incompatible with strong oxidizers, copper salts, and amine-functionalized cleaning solvents, all of which can alter polymerization kinetics or cause premature gelation in the vat.

    When 385 nm Resin Replaces a 405 nm Grade in Existing DLP Platforms

    Replacement of a 405 nm resin with a 385 nm grade requires more than changing the exposure time. The optical train of a DLP or LCD printer may include anti-reflection coatings, polarizers, and light guides whose transmission at 385 nm is lower than at 405 nm. Build-plane irradiance must be measured with a calibrated radiometer with a full-width half-maximum bandpass of no more than 10 nm; a value that is 20–30 % lower at 385 nm can move the process out of the resin’s working curve. Recalculation of exposure follows the same Jacobs equation, but the lower penetration depth of the 385 nm resin may require compensation through reduced layer thickness or increased irradiation time. The shorter wavelength also increases photon energy to 3.22 eV, which can promote chromophore degradation and higher yellowing in unpigmented or clear formulations unless hindered amine light stabilizers are present. In contrast, a 405 nm resin may exhibit greater penetration and lower surface inhibition for a given oxygen environment but may require a longer exposure because its photoinitiator absorption cross-section is lower at that wavelength. Published data for this specific configuration is limited where the vat film material and projector optics are proprietary, so a working-curve calibration on the actual machine is mandatory.

    Parameter385 nm resin class405 nm resin class
    Photon energy3.22 eV3.06 eV
    Typical clear-resin penetration depth Dp120–180 µm180–250 µm
    Typical clear-resin critical energy Ec8–20 mJ/cm²12–30 mJ/cm²
    Common initiator absorption band370–410 nm380–430 nm
    Surface tack before post-curemoderatelow to moderate
    Yellowing tendency in clear formulationshigher if unstabilizedlower

    Type-release qualification for the 385 nm resin follows the test matrix in the table below. The supplier certificate of analysis reports lot-specific values for viscosity, density, and photoinitiator content. Tensile and flexural specimens are printed or machined to the geometry required by the relevant standard and post-cured using the same recipe intended for production; if the production post-cure is changed by more than ±5 °C or ±10 min, the mechanical data must be regenerated.

    Test methodPropertySpecimen/conditionReported unit
    ASTM D638-14Tensile strength, tensile modulus, elongation at breakType IV, 5 mm/min, 23 °C, 50 % RHMPa, MPa, %
    ASTM D790-17Flexural strength, flexural modulus3-point bend, 1.3 mm/min, 23 °CMPa, MPa
    ASTM D256-10Notched Izod impact63.5 × 12.7 × 6.4 mm, 23 °CJ/m
    ASTM D648-18Heat deflection temperature at 0.455 MPa and 1.82 MPa120 × 12.7 × 6.4 mm, edgewise°C
    ASTM D2240-15Shore D hardness6 mm plaque, 15 s dwellShore D
    ISO 1183-1:2019DensityLiquid and curedg/cm³
    ASTM D2196-20Rotational viscosityBrookfield, 25 °C, spindle 63mPa·s

    For regulatory compliance, the supplier provides batch-specific REACH and RoHS declarations; FDA 21 CFR 177.2600 or ISO 10993-5 statements are not implied unless separately listed. If the resin is used in biomedical, food-contact, or toy applications, migration testing according to EU 10/2011 or applicable regional standards must be completed on the final printed article because the printed surface and post-cure conversion can alter leachable content.