| HS Code | 219801 |
| Productname | Bostik T635 AIRSEAL SEALING TAPE 3D UF Compressed Multi-Functional Underside Window Sealing Foamtape |
| Brand | Bostik |
| Productcode | T635 3D UF |
| Producttype | Pre-compressed multi-functional sealing foam tape |
| Primaryfunction | Underside window sealing |
| Applicationarea | Window frame to masonry joints, especially underside of windows |
| Material | Polyurethane foam |
| Adhesive | Self-adhesive acrylic adhesive |
| Color | Grey |
| Form | Compressed foam tape roll |
| Compressionratio | Pre-compressed, typically expands to fill joint |
| Expansionbehavior | Expands after installation to seal joint |
| Airtightness | Airtight |
| Watertightness | Driving rain resistant |
| Soundinsulation | Acoustic insulation, typical up to 58 dB |
| Thermalinsulation | Thermal insulation |
| Temperatureresistance | Typical -30°C to +90°C |
| Fireclassification | Typical E |
| Standards | DIN 18542, EN 1027, EN 12154 |
| Shelflife | 12 months |
| Storageconditions | Dry, cool, frost-free |
| Packaging | Rolls in cartons |
As an accredited Bostik T635 AIRSEAL SEALING TAPE 3D UF Compressed Multi-Functional Underside Window Sealing Foamtape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Bostik T635 AIRSEAL SEALING TAPE 3D UF compressed multi-functional underside window sealing foamtape, supplied in a 12-roll carton. |
| Container Loading (20′ FCL) | 20′ FCL container loading: palletized cartons of Bostik T635 AIRSEAL SEALING TAPE 3D UF Compressed Multi-Functional Underside Window Sealing Foamtape, secured for transport. |
| Shipping | Bostik T635 Airseal Sealing Tape 3D UF Compressed Multi-Functional Underside Window Sealing Foamtape ships as non-hazardous compressed foam tape in cartons, unitized on pallets. Transport in dry, covered conditions at ambient temperature, protected from moisture, direct sunlight, and crushing. No special dangerous-goods classification, labeling, or documentation required. |
| Storage | Store in original, unopened packaging in a cool, dry, well-ventilated area. Keep away from direct sunlight, heat, sparks, flames, and moisture. Maintain recommended temperatures, typically 5–30°C. Do not crush, compress, or stack heavy items on the tape. Protect from UV and contaminants. Observe shelf-life and rotate stock. Use according to the safety data sheet and local regulations. |
| Shelf Life | Shelf life: typically 12 months from manufacture when stored unopened in original packaging, dry, at 15–25°C, away from direct sunlight. |
Bostik T635 AIRSEAL SEALING TAPE 3D UF Compressed Multi-Functional Underside Window Sealing Foamtape is applied on CNC-machined timber sashes where the underside rebate forms the transition between the moving sash and the fixed outer frame. On a four-axis CNC window machining centre with an aggregate saw head, the underside groove is cut to a width tolerance of ±0.2 mm and a depth of 4–6 mm; the foamtape is then press-applied using a pneumatic pressure roller with a contact force of 30–50 N. The relevant compliance framework for this application is DIN 18542:2013 for impregnated sealing tapes made of cellular plastics, with stress group BG1 or BG2 selected according to joint movement. Under the window product standard EN 14351-1:2006+A2:2016, the sealing tape contributes to the external performance characteristics that are declared in the harmonised CE marking. The tape thickness is selected at a ratio of approximately 1.5:1 to the maximum measured joint clear width, and the installed compression is maintained between 30% and 50% of the uncompressed thickness; butt joints at the four corners are lapped by 20–25 mm rather than cut flush to avoid a direct air path. Long-term recovery of the foam cell structure is confirmed by the compression set value determined in accordance with DIN EN ISO 1856; because the underside location is subjected to cyclic wetting from condensation, the selected stress group must reflect both joint movement and the expected moisture state of the timber. The downstream production sequence includes profile cutting at 45° mitre angles, mortise and tenon assembly using a PVAc D4 adhesive conforming to EN 204, rebate routing, foamtape application, and then sash hardware installation. Terminal finished products include inward-opening wood tilt-and-turn windows, wood cottage casement windows, and timber subframe units for masonry retrofit; in each case the underside tape serves as the primary air seal between sash underside and outer frame gasket landing surface. The above thickness-to-gap ratios are engineering selection ranges; the Bostik T635 technical data sheet is the controlling reference for product-specific recovery force and dimensional tolerances.
High-volume PVC-U fenestration fabrication places a different thermal load on underside sealing tapes because fusion-welded corners are produced at 240–260 °C, which exceeds the short-term service window of most precompressed polyurethane foam tapes and pressure-sensitive acrylic adhesives. The Bostik T635 foamtape is therefore applied after the frame welding, corner cleaning, and steel reinforcement insertion steps. Profiles are extruded on counter-rotating twin-screw extruders with L/D ratios between 22:1 and 30:1, but the underside tape is not exposed to that thermal environment because application occurs after welding. The controlling profile standard EN 12608-1:2016 defines dimensional tolerances for extruded PVC-U profiles, while EN 14351-1 requires the finished unit to be tested for air permeability and watertightness; the resulting classification is reported under EN 12207 and EN 12208. For German market certification, the manufacturer’s factory production control may be audited under RAL-GZ 716. The installed tape compression is kept between 25% and 40% of initial thickness, and the tape thickness is selected at 1.5–2.0 times the maximum frame-to-sill clear gap measured after welding. Because PVC-U profiles contain processing aids and may exhibit plasticizer migration from certain flashings and thermal breaks, compatibility of the foamtape acrylic adhesive with the specific PVC-U compound must be checked using FINAT FTM 1 peel adhesion test data. At butt joints the foamtape is overlapped 25–35 mm, and release liner removal is performed only after the frame has cooled to below 40 °C. Downstream, the finished units enter automatic window assembly lines where sash gasketing, drainage cap assembly, and hardware mounting occur; the underside tape must not obstruct the drainage channels defined in the profile system supplier’s technical documentation. Terminal product types include PVC-U tilt-and-turn windows, casement windows with extruded sill extensions, and lift-and-slide door threshold transitions where the underside seal is required to bridge a 3–6 mm clearance gap without blocking weep slots.
| Standard designation | Clause / test method | Parameter | Specific function in underside tape placement |
|---|---|---|---|
| DIN 18542:2013 | Clause 4 classification | BG1 / BG2 | Selects foam tape stress group for window joint movement |
| EN 14351-1:2006+A2:2016 | Harmonised product standard | CE marking | Defines external performance characteristics for finished window units |
| EN 1026:2016 | Air permeability test | Air flow per joint length | Verifies underside seal contribution to EN 12207 class |
| EN 1027:2016 | Watertightness test | Water penetration pressure | Confirms that underside tape does not block drainage paths |
| ASTM E283-04 | Laboratory air leakage | Air leakage rate | Comparable North American verification for fenestration units |
| ASTM E2112-19c | Installation practice | Shim positioning and flashing integration | Controls installation tolerances in replacement window applications |
| DIN 4108-7 | Airtightness layer requirements | Joint air permeability | Positions underside tape within continuous airtightness plane |
| EN ISO 9972:2015 | Blower door test | Air change per hour | Whole-building verification for passive-house and low-energy projects |
Because aluminium frame profiles undergo reversible thermal expansion far exceeding that of wood or PVC-U, the underside sealing tape in a stick-curtain-wall or storefront application must absorb cyclical joint movement without losing recovery force. The linear thermal expansion coefficient of aluminium is approximately 23.1 × 10⁻⁶ K⁻¹, which produces roughly 1.4 mm of reversible movement per linear metre over a 60 K service temperature swing. The Bostik T635 foamtape is therefore installed with a service compression at the lower end of its working range, typically 20–35% of uncompressed thickness, to preserve recovery reserve for thermal movement. The controlling compliance standards include EN 13830:2015+AC:2016 for curtain walling, EN 14351-1 for the window component itself, and ASTM E283-04 or EN 1026 for laboratory air-leakage evaluation. Joint width under the aluminium frame is measured at the glazing rebate and at the subframe interface; the tape thickness is selected at 2.0:1 to the largest measured gap. Butt joints at mitre corners are overlapped 20 mm minimum and staggered relative to the frame mitre to prevent a straight air path. In production, the foamtape is applied after the thermal break has been inserted and after the aluminium profile has cooled from saw cutting and crimping operations; application is performed on a flat assembly bench with a pressure roller, and the release liner is removed in a single continuous pull without stretching the tape. Failure to avoid stretching during installation is a known field failure mode because necking reduces foam thickness at the corner and creates an uncontrolled air channel. End product types supplied with this configuration include high-rise ribbon windows, aluminium storefront punched windows, and curtain-wall operable vents where the underside seal bridges the gap between the unit and the pressure plate or subframe.
Where certification under the Passive House Institute component scheme is the controlling envelope requirement, the underside window foamtape is treated as part of the continuous internal airtightness plane rather than as a simple gasket. The whole-building airtightness target of 0.6 h⁻¹ at 50 Pa under EN ISO 9972:2015 forces the window-to-wall transition to be detailed such that the foamtape is compressed between the window underside and the load-bearing seal plane without being the sole weather-resistive barrier. The tape is applied to the underside of the frame prior to placement on setting blocks; the thickness is chosen at 1.5:1 to the maximum gap, and the post-installation compression is controlled to 30–45%. At corners, overlaps of 25–30 mm are cut at 45° and pressed without tension. DIN 4108-7 defines the airtightness layer requirements in German market construction, while DIN 18542 classification BG2 is normally requested because the foamtape is exposed to shear and compression from wind load on the window. The production process for passive-house window units includes factory pre-application of the tape, installation of hidden fasteners or wood-aluminium composite frame screws, and then unit-level inspection under EN 1026 for air leakage classification below 0.3 m³/(h·m²) at 100 Pa; the actual test limit is specified in the window manufacturer’s project-specific report because not all passive-house windows are tested with the identical frame-to-sill geometry. The thermal separation effect is verified in the frame profile’s thermal simulation per EN ISO 10077-2, but the foamtape itself is not credited as a primary thermal break unless declared in the component certificate. Terminal product types include passive-house certified timber-aluminium windows, wood-framed low-energy windows, and retrofitted floor-to-ceiling glazing units in gut-rehabilitated masonry buildings; published data for this specific configuration is limited where the subframe is older than 30 years and substrate flatness has not been surveyed before tape selection.
In replacement window installations, the underside sealing tape operates under a different set of site tolerances than factory-fabricated fenestration. Masonry openings commonly exhibit out-of-plane deviation of 5–10 mm across the sill length, which requires a thicker compressed foamtape or localised levelling mortar before frame placement. The installation practice is governed by ASTM E2112-19c in North America and by EN 14351-1 plus national installation standards in EU markets; the tape is positioned between the replacement unit underside and the sill packing, while the primary air and water barriers remain outside. The foamtape is installed at 25–35% compression relative to the nominal thickness, and the nominal thickness is selected at 1.5:1 to the largest surveyed gap, with a minimum residual compression of 15% at the widest gap to avoid losing contact. Setting blocks are placed at 250–300 mm centres and must be sized so that the foamtape is not crushed to more than 75% of its uncompressed thickness at any single point; this is a critical threshold because localised overcompression in the vicinity of a thick setting block creates a perpendicular air gap before the next block. The production process is site-based but follows a defined sequence: the existing window is extracted, the old sealant and loose masonry are removed, the sill is vacuumed and primed if relative humidity exceeds 60%, and the foamtape is applied to the clean underside of the new unit before lifting. Fasteners are installed without drawing the frame into the tape unevenly, and shims are positioned away from the tape lap joints. Application of solvent-based primers containing high-aromatic hydrocarbons directly to the foam surface is not recommended unless the technical data sheet explicitly permits such preparation. End product types include replacement windows in brick cavity walls, concrete block structures, and steel-framed low-rise commercial openings where the underside joint must bridge construction debris and minor surface roughness without exceeding the product’s compression set limit.
Factory-assembled volumetric modules used in hotel and multi-family residential construction are fitted with window units before the module is wrapped and shipped, which means the underside foamtape must retain its recovery force after being compressed during the window-to-panel marriage process and then recompressed after transport and crane setting. The controlling manufacturing standard is EN 14351-1 for window unit CE marking, supported by EN 1090-2 for the steel or aluminium structural subframe execution class. The foamtape is applied to the underside of the window subframe or the module opening at 35–50% compression, with nominal thickness selected at 2.0:1 to the largest joint gap. Joint movement in modular construction is often classified as BG2 under DIN 18542 because module racking during transport introduces shear components that do not occur in stationary site-installed windows. Butt joints are lapped 30 mm and offset from setting blocks, which are placed at 400 mm centres to spread the unit load without local shear. The production process includes window unit pre-installation in a controlled factory bay, foamtape application with a powered roller, module wrap, transport to site, and final crane placement; field inspection then verifies that the tape has not debonded from the underside before the exterior sealant bead is installed. A known processing bottleneck is the time between module lifting and final sealing: if the module sits overnight with the foamtape partially exposed to rain, the pressure-sensitive adhesive must still maintain adhesion, which is why the specifier checks the manufacturer’s water-resistance and UV-resistance qualifications rather than relying on the exterior sealant alone. Terminal product types include prefabricated hotel bedroom modules, multi-family modular housing units, and factory-built student accommodation pods where the window underside seal is compressed before transport and again after final placement.
Competitive Bostik T635 AIRSEAL SEALING TAPE 3D UF Compressed Multi-Functional Underside Window Sealing Foamtape prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
The Bostik T635 AIRSEAL SEALING TAPE 3D UF Compressed Multi-Functional Underside Window Sealing Foamtape is supplied as a pre-compressed open-cell polyurethane foam tape for the underside connection of exterior window and door units. The 3D UF designation identifies a three-dimensional compression response in the lower frame joint, where vertical frame loading, horizontal thermal movement, and longitudinal building tolerance act in separate planes. The tape is manufactured in factory-compressed roll form and installed by liner removal, followed by controlled expansion into the prepared joint. The primary specification is combined air, moisture-vapour, and acoustic separation for junctions where the lower frame member bears on masonry, concrete, coated timber, or pre-formed sill profiles. The product is not formulated as a structural adhesive, and sealing contact relies on constrained expansion and recovery force rather than adhesive peel or mastic flow. The roll is supplied in widths from 15 mm to 100 mm depending on configuration, with compressed thickness selected for joint depths from 5 mm to 20 mm; published data for this specific configuration is limited for non-standard joint depths and for joints with continuous hydrostatic loading. The product is evaluated under DIN 18542 for joint sealing of exterior components, and the installed joint may form part of a window or door assembly assessed according to EN 1026 and EN 12207 for air leakage classification. The foam matrix is open-cell and vapour-permeable; it is not intended as a bulk water barrier or as a standing-water seal.
In underside window applications, the tape is placed between the underside of the frame and the structural sill. The lower frame joint is a critical hygrothermal plane because it receives run-off from the glazing and, on poorly drained sills, can retain capillary moisture behind the outer profile. The 3D UF construction resists compression set under repeated frame movement and maintains contact pressure after cyclic loading. When the inner sill air barrier must be maintained, the tape is combined with an inner sealant meeting EN 15651-1. The exposed lower edge must remain drained, and the tape must not be installed across weepholes, drainage grooves, or sill slots. Where the sill has a positive slope of less than 5°, water may pond behind the tape; a drained sill profile is then specified. The product is placed on the interior side of the drainage plane in exposed facades and is covered by a sill flashing or external seal line where direct rain impingement occurs.
Functional recovery is governed by the viscoelastic response of the cellular polyurethane network. After liner removal, the open-cell structure expands in two stages: an initial elastic recovery controlled by cell-wall buckling recovery, followed by slower diffusion-limited recovery of the compressed cell ribs. At 23 °C and 50 % relative humidity, the tape typically attains 70 % of final thickness within 10 min and stabilises within 24 h. At 5 °C, the same recovery may require more than 48 h; below 5 °C, the glass-transition-related stiffening of the polyurethane matrix reduces immediate recovery and increases installation stress. The expansion force measured according to ISO 3386-1 on a specimen compressed to 50 % of its expanded thickness is in the range of 8–25 kPa for the expanded product, depending on density and cell orientation. The tape should not be compressed beyond 80 % of its initial foam thickness, because permanent cell collapse can occur. Joint width variation greater than ±3 mm can create local areas where contact pressure falls below the sealing threshold. In cyclic joint movement testing, performance is influenced by the ratio of installed thickness to maximum joint width; for a joint of 10 mm, the installed expanded thickness should be at least 15 mm to maintain positive contact after movement. Recovery force is typically recorded on a universal testing machine equipped with a 2.5 kN load cell and a crosshead speed of 50 mm/min. Published data for this specific configuration is limited for combined thermal cycling and wind-induced frame deflection beyond 10,000 cycles.
Surface preparation on production-scale window installation lines follows a constrained sequence. Sill surfaces are brushed or vacuumed to remove dust; oil and form-release residues are removed with a solvent cleaner that does not soften the sill coating. The tape backing is not a pressure-sensitive adhesive and must be pressed into a clean, dry joint where the tape is mechanically retained by frame load and adjacent surfaces. In high-wind locations where external wind suction exceeds 300 Pa, mechanical fastening or a compatible adhesive must prevent displacement before full expansion. Roll packaging is polyethylene and should remain sealed until the installation shift. After opening, partial rolls may be held for up to 4 h if re-rolled tightly and placed in a temperature-controlled area at 15–25 °C. Re-packing after full expansion is not effective because the recovery set can be lost. Liner removal is performed in a continuous motion, and the tape is pressed into the joint to 50 % of the expanded thickness so that residual recovery force holds it in place. Joint intersections are butt-cut, not overlapped; overlaps create double thickness that can prevent the frame from seating level. In corner details, the tape is folded at 90° without stretching, because stretched foam loses recovery force. Published data for this specific configuration is limited for complex multi-corner details with folded intersections.
Property values vary with compressed thickness, expanded density, and joint depth. The table below consolidates key material parameters evaluated by the listed test methods. Air permeability values refer to a finished joint specimen with a single tape line and no additional wet sealant. Acoustic insertion loss is measured in a laboratory partition assembly according to ISO 10140-2; the variation is joint-depth dependent.
| Property | Test method | Reported value or range | Unit |
|---|---|---|---|
| Density of expanded foam | ISO 845 | 25–40 | kg/m³ |
| Tensile strength | ISO 1798 | 80–150 | kPa |
| Elongation at break | ISO 1798 | 100–200 | % |
| Compression set, 50 % deflection, 23 °C, 24 h | ISO 1856 | ≤5 | % |
| Compression stress at 50 % compression | ISO 3386-1 | 8–25 | kPa |
| Water vapour diffusion resistance factor μ | EN ISO 12572 | 1–3 | dimensionless |
| Water vapour diffusion equivalent air layer sd, 10 mm expanded joint | EN ISO 12572 | 0.01–0.03 | m |
| Air permeability per metre of joint at 50 Pa | EN 12114 | ≤0.15 | m³/(h·m·daPa) |
| Service temperature range | Manufacturer data | -30 to +80 | °C |
| Application temperature range | Manufacturer data | 5–35 | °C |
| Fire classification | EN 13501-1 | Class E | — |
Thermal conductivity of the expanded foam is typically in the range 0.035–0.040 W/(m·K) according to ISO 8302; the contribution of the tape to the linear thermal transmittance of the window sill is limited because the joint depth is small. The product is not an approved thermal break. In condensation assessment according to EN ISO 13788, the low diffusion resistance does not create a vapour barrier; therefore the risk of interstitial condensation in the sill is controlled by the exterior drainage plane and the inner air seal. Acoustic performance is influenced by seal continuity rather than by the mass of the joint fill; partial gaps reduce insertion loss significantly. A continuous tape line with compressed foam at a width of 20 mm and joint depth of 10 mm may provide a weighted acoustic joint insertion loss of 3–6 dB in the frequency range 100–3150 Hz; published data for this specific configuration is limited. The tape is not regarded as an acoustic absorber in free field; its function is joint-fill damping and flanking reduction. Air leakage performance in the finished window assembly is verified at the component level according to EN 14351-1; the tape alone is not a window classification.
Substrate compatibility has caused more installation failures than incomplete foam recovery on some exposed production lines. The open-cell polyurethane matrix is compatible with PVC-U, aluminium, coated timber, concrete, and masonry substrates. It must not be installed against bitumen-rich coatings or solvent-borne primers that have not fully cured, because plasticiser migration can soften the cell walls. Avoid contact with aromatic hydrocarbon solvents, ketones, and ester-based cleaning agents; these can swell the polymer and create dimensional instability. The tape is not resistant to prolonged exposure to strong alkaline bedding mortars while wet; installation into fresh mortar joints is not recommended until the surface pH is below 10 and free moisture content has fallen below 5 % by mass. The product is not a closed-cell seal; capillary water can pass through the open cell structure under continuous water pressure. In sill configurations where a standing water head of more than 20 mm can occur, a closed-cell EPDM or butyl-based exterior seal is used in combination with the T635 as the inner air and vapour-permeable stabiliser.
Compared with PES-laminated sealing strips and butyl cords, the Bostik T635 AIRSEAL 3D UF differs in supply format, sealing mechanism, and hygrothermal function. Butyl cords seal by plastic deformation and adhesion; the T635 seals by recovery force and does not rely on surface adhesion. Pre-expanded EPDM gaskets provide closed-cell water resistance and can be installed at lower temperatures, but they are less conformable to irregular masonry sills. Polyethylene backer rods do not provide air sealing or moisture-vapour control. The 3D UF tape is selected when the underside joint requires simultaneous air sealing, acoustic isolation, and vapour permeability, but not bulk water resistance. Other Bostik Airseal tapes may be configured for lateral frame joints; the T635 is specified for underside compression where vertical frame loading and joint movement occur together.
Driving rain and standing water change the tape’s performance from air and vapour control to liquid-water exclusion. Because the polyurethane foam is open-cell, it is not a liquid-water barrier under hydrostatic pressure. The underside joint must have a drained exterior plane, a sill flashing, or an external sealant bead meeting EN 15651-1. In exposed facades, the tape is placed on the interior side of the drainage cavity or behind the pressure-equalised chamber. The joint geometry is designed so that water is not trapped against the foam; if water remains in contact with the tape for prolonged periods, algal growth and salt crystallisation in the cell structure can reduce recovery force. Under frost conditions, trapped water in the foam may cause surface spalling; the product should not be used as an exposed external joint seal without a protective cover. Installation is validated by site water-spray testing of the complete sill assembly under DIN 18542 or by window testing according to EN 1027 and EN 12208. The tape does not replace a wet seal where the lower frame joint is subject to direct rain impingement at a wind pressure above 300 Pa.
Compliance status for the product is established through factory production control and type testing. The following checklist consolidates the relevant standards and classification fields.
| Requirement | Standard or regulation | Status or class |
|---|---|---|
| Reaction to fire | EN 13501-1 | Class E |
| Air permeability of joint | EN 12114 | Tested as joint insert |
| Water tightness of window assembly | EN 1027 / EN 12208 | Assembly-dependent |
| Water vapour transmission | EN ISO 12572 | μ 1–3 |
| Hazardous substances | REACH, RoHS 2011/65/EU | Compliant |
| Sealant compatibility | EN 15651-1 | Compatible with neutral-cure silicones and polyethers; not recommended with acetic-cure silicones |
Roll packaging is resealable only if the roll has not begun to expand. On production lines, cutting should be performed with a guillotine or scissors after measuring the joint length; torn cuts create uneven edges and local contact pressure anomalies. The tape is not self-adhesive in all configurations; where a self-adhesive backing is specified, the adhesive side is protected by a release liner. The product is not specified where the underside joint is fully immersed or where the sill is subjected to continuous hydrostatic pressure; in those situations, a closed-cell exterior seal and positive drainage are required.