| HS Code | 491477 |
| Polymer Type | Silane crosslinkable polyethylene (XLPE after moisture cure) |
| Crosslinking Method | Moisture/silane |
| Density | 0.923 g/cm³ |
| Melt Flow Rate | 0.8 g/10 min (190°C/2.16 kg) |
| Tensile Strength | >17 MPa |
| Elongation At Break | >400% |
| Hot Set Elongation | <175% (200°C, 15 min, 0.2 MPa) |
| Permanent Deformation | <15% |
| Volume Resistivity | >1×10^14 Ω·cm |
| Dielectric Constant | 2.3 (50 Hz) |
| Dissipation Factor | <0.001 (50 Hz) |
| Dielectric Strength | >25 kV/mm |
| Water Absorption | <0.1% |
| Thermal Conductivity | 0.3 W/m·K |
| Brittleness Temperature | -70°C |
As an accredited Borealis Visico XLPE ME4425 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Borealis Visico XLPE ME4425 is supplied in moisture-protective 25 kg polyethylene bags, typically palletized for industrial handling and storage. |
| Container Loading (20′ FCL) | Chemical Borealis Visico XLPE ME4425 is palletized and loaded into a dry, secure, properly labeled 20-foot FCL container. |
| Shipping | Borealis Visico XLPE ME4425 is shipped as non-hazardous, moisture-crosslinkable polyethylene pellets in sealed moisture-proof 25 kg bags or bulk octabins. No UN number, hazard class, or packing group applies. Keep packaging closed, dry, and protected from heat and direct sunlight; store at ambient temperature and follow SDS/local transport regulations. |
| Storage | Store Borealis Visico XLPE ME4425 in its original, sealed packaging in a cool, dry, well-ventilated area protected from direct sunlight, moisture, heat, and ignition sources. Keep containers closed and avoid contamination with dust, water, or incompatible materials. Maintain clear labeling and use first-in-first-out stock rotation. Follow the manufacturer’s safety data sheet and local regulations for storage and handling. |
| Shelf Life | Typically 6–12 months from production when stored dry, cool, and in original unopened packaging, per Borealis recommendations. |
Low-voltage power distribution cable insulation is the highest-volume conversion channel for Borealis Visico XLPE ME4425. The compound is run as a two-part system, with 95.0 wt% ME4425 and 5.0 wt% Ambicat catalyst masterbatch metered by gravimetric feeders into a single-screw extruder. On a 60 mm extruder with a 30:1 L/D barrier screw, barrel setpoints are staggered from 145 °C near the feed zone to 185 °C at the crosshead. Melt temperature at the die is held between 175 °C and 190 °C. The screw speed is adjusted to maintain a melt pressure of 15 MPa to 25 MPa before the breaker plate. The extrudate is drawn onto stranded copper or aluminium conductors from 1.5 mm² to 400 mm², with radial wall thickness from 0.7 mm to 2.0 mm. The hot insulation passes through an air gap of 50 mm to 120 mm, then enters a water trough at 70 °C to 90 °C. Final moisture curing occurs on reel under ambient conditions for 48 h to 96 h, or in a sauna at 80 °C and 85% RH for 6 h to 12 h. The terminal cable is qualified to IEC 60502-1 for 0.6/1 kV systems. Hot-set testing under IEC 60811-507 at 200 °C and 0.20 MPa must show elongation under load below 175% and permanent set below 15%. Tensile retention after ageing in a circulating air oven at 135 °C for 168 h must remain above 75%. This segment tolerates some surface roughness because the outer sheath or armouring hides it, but the insulation must be free of microvoids above 25 µm that could initiate partial discharge in wet underground installations.
Photovoltaic DC string cable insulation exposes ME4425 to a combined thermal, UV, ozone, and damp-heat load that is not present in indoor distribution cable. For 1,500 V DC solar arrays, single-core constructions with tinned copper conductors from 1.5 mm² to 35 mm² are common. The insulation wall is usually 0.7 mm to 1.1 mm thick. Crosslink density in this thin wall is diffusion-controlled. The outer skin cures first and can retard further moisture ingress into the inner layer. The 95:5 catalyst ratio must be held within ±0.3 wt% to prevent surface tack from residual silane and scorch from over-catalysed graft reaction. A 45 mm single-screw extruder with a 25:1 L/D compression screw and a Maddock shear mixer is used, with barrel setpoints from 140 °C to 185 °C and a die melt temperature of 180 °C. After the crosshead, the insulation enters a 75 °C water bath for 15 s to 40 s, then cures on coil in a steam chamber at 85 °C and 90% RH for 8 h. A halogen-free flame-retardant polyolefin sheath is applied in a separate extrusion. The finished cable must pass the EN 50618 requirement for 1.5 kV DC, long-term wet ageing, ozone resistance, UV weathering, and cold impact at -40 °C. Hot-set by IEC 60811-507 is often specified at 200 °C and 0.20 MPa with elongation below 100% to guarantee a gel content above 70%. The insulation must also pass the IEC 62930 damp heat test with insulation resistance above 1,000 MΩ·km after 168 h at 85 °C and 85% RH. Failure modes observed in the field include insufficient cure at the conductor interface, which appears as high hot-set and conductor pull-back during connector assembly. The cure chamber humidity must not fall below 80% RH, otherwise surface crosslinking seals the wall and produces a soft, uncured inner layer.
| Application | Primary standard | Typical wall thickness | Cure condition | Critical test |
|---|---|---|---|---|
| Low-voltage power distribution | IEC 60502-1 | 0.7–2.0 mm | Water bath 70–90 °C, reel cure 48–96 h | Hot set 200 °C, 0.20 MPa |
| Photovoltaic DC string cable | EN 50618 | 0.7–1.1 mm | Steam chamber 85 °C, 90% RH, 8 h | Damp heat after 168 h |
| Automotive primary wire | ISO 6722 | 0.25–1.2 mm | Water bath 50–70 °C, ambient cure | Short-term ageing 150 °C, 240 h |
| Industrial control cable | EN 50288-7 | 0.5–1.5 mm | Humidified air 25–40 °C, 70–85% RH, 24–72 h | Insulation resistance 20 °C, 5,000 MΩ·km |
| Thin-wall appliance wiring | UL 1581, IEC 60332-1-2 | 0.25–0.5 mm | Water bath 30–50 °C, humid cure 80 °C, 85% RH, 4–8 h | Flame propagation VW-1 |
Automotive primary wire insulation uses thin-wall construction and high-speed extrusion, where ME4425 operates alongside electron-beam crosslinked and peroxide-cured compounds. Conductor sizes from 0.35 mm² to 6 mm² are insulated with wall thickness from 0.25 mm to 1.20 mm. Line speeds on 50 mm extruders with 30:1 L/D screws can reach 800 m/min to 1,200 m/min for small conductors. The melt temperature must not exceed 195 °C to avoid premature silanol condensation in the head. Conductor preheat at 80 °C to 120 °C improves adhesion and removes residual moisture. The catalyst masterbatch is let down at 5.0 wt%. Because dwell time in the extruder is short, the silane graft distribution is maintained by a 3:1 compression ratio screw. After extrusion, the coated wire passes through a cooling trough at 50 °C to 70 °C, then is coiled for ambient moisture cure. For automotive thermal class C at 125 °C, short-term ageing is tested at 150 °C for 240 h according to ISO 6722. Tensile strength retention must remain above 80%. Fluid compatibility is tested in gasoline, diesel, engine oil, and battery acid. ME4425 is a non-polar polyethylene, so aromatic fuel absorption can soften the compound unless the specification limits fuel exposure or an outer layer is used. Published data for ME4425 in direct fuel immersion under this specific configuration is limited, and each automotive specification must evaluate end-use fluid combinations. The terminal product is primary wire for engine compartment harnesses where conductor temperature does not exceed 125 °C and where thin-wall insulation reduces harness mass. The silane-cure route avoids peroxide residues and produces low outgassing, which is relevant in sealed connector zones.
In process automation and instrument loop installations, the insulation must preserve low capacitance, high insulation resistance, and stable dielectric strength over decades of installation. ME4425 is extruded onto solid or stranded tinned copper conductors from 0.5 mm² to 2.5 mm². Wall thickness ranges from 0.5 mm to 1.5 mm. The compound is often pigmented in the melt with a polyolefin colour masterbatch at 2 wt% for core identification in multi-pair cables. The catalyst ratio remains 95:5. Because process plants can have high humidity, the moisture cure is intentionally retarded until the cable core assembly is laid up. Partially cured insulation allows tight pair twisting without cracking. The laid-up cable is then stored in a humidified area at 25 °C to 40 °C and 70% RH to 85% RH for 24 h to 72 h. Qualification for instrumentation cable is performed to EN 50288-7. Insulation resistance at 20 °C must exceed 5,000 MΩ·km. Dielectric strength under IEC 60243-1 should be above 20 kV/mm for new cable. After immersion in water at 70 °C for 14 days, insulation resistance should remain above 500 MΩ·km. The material is limited in direct hydrocarbon oil contact. XLPE is not inherently oil-resistant, and cables routed through pump skids should be protected by a metallic braid or an oil-resistant sheath. For signal circuits where flame propagation is governed by IEC 60332-1-2, a halogen-free sheath is typically used because the XLPE insulation itself is not flame-retardant. The terminal product is multi-pair control cable used in chemical, pharmaceutical, and water-treatment plant junctions.
Thin-wall appliance wiring below 0.5 mm radial wall thickness places the silane-cure reaction into a short-diffusion regime. ME4425 is used on tinned copper strands from 0.25 mm² to 1.5 mm². A 45 mm extruder with a 25:1 L/D screw operates at a melt temperature of 185 °C to 200 °C. The die is a pressure tool with a draw ratio of 1.5:1 to 2.5:1. The 95:5 catalyst ratio is maintained. Crosshead pressure is typically 10 MPa to 18 MPa. The extruded insulation passes through a short air gap, then enters a water bath at 30 °C to 50 °C. Immediate quenching in cold water produces a thinner crystalline skin, which improves moisture permeability and reduces cure time. The reel is then held at 80 °C and 85% RH for 4 h to 8 h. The terminal product must meet UL 1581 VW-1 vertical flame propagation for internal wiring in household appliances and power tools. Heat ageing is evaluated at 125 °C for 168 h to IEC 60811-501. Tensile strength and elongation retention must stay above 75%. Shrinkage after ageing below 2% is accepted for most harness manufacturers. The main processing defect in this segment is conductive scorch particles from overcured compound in the crosshead. Screen packs of 100 mesh to 120 mesh are installed downstream of the breaker plate to trap gel particles above 80 µm. This segment is less standard-intensive than automotive, but the cumulative scrap rate determines material acceptance. If ambient RH at the hopper exceeds 60%, the compound must be dried at 50 °C for 4 h before the run.
Residential and commercial building wire in concealed conduit routes imposes different flame-spread and smoke-density constraints than outdoor distribution cable. ME4425 is extruded onto solid copper conductors from 1.5 mm² to 10 mm². Wall thickness is 0.6 mm to 1.0 mm. The insulation is often a dual-layer construction with a coloured XLPE outer skin for phase identification. The catalyst masterbatch is dosed at 5.0 wt%. Extrusion uses a 65 mm extruder with a 25:1 L/D screw. The melt temperature at the die is maintained at 180 °C. The coated wire is quenched in water at 40 °C to 60 °C and then moisture-cured at 70 °C and 80% RH for 12 h. The finished wire must pass IEC 60332-1-2 for single-wire flame propagation. When tested to IEC 61034-2 in a smoke chamber, the XLPE insulation contributes low smoke density compared with PVC compounds. This supports its use in low-smoke building wiring systems. Insulation resistance after 48 h water immersion at 20 °C must remain above 1,000 MΩ·km. The crosslinked polyethylene insulation is rated for continuous conductor temperature of 90 °C in dry environments. A known operational boundary is that the compound is not a plasticised PVC and does not contain halogen or phthalate plasticisers. Halogen acid gas generation can be tested to IEC 60754-1, with conductivity below 2 µS/mm for non-halogenated polyolefin. This building-wire segment therefore places ME4425 between standard XLPE power insulation and low-smoke halogen-free specifications, requiring the processor to control cure uniformity without relying on plasticiser migration or stabiliser volatilisation.
Competitive Borealis Visico XLPE ME4425 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!