Products

Borealis Visico MDPE ME4425/LE4462

    • Product Name: Borealis Visico MDPE ME4425/LE4462
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: sales8@sinochem-nanjing.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 734062
    Density 0.933 g/cm³
    Meltflowrate 0.7 g/10 min (190°C/2.16 kg)
    Tensilestrength 20 MPa
    Elongationatbreak 500%
    Flexuralmodulus 700 MPa
    Meltingpoint 125 °C
    Vicatsofteningtemperature 115 °C
    Dielectricconstant 2.3
    Volumeresistivity 1E15 Ω·cm
    Dielectricstrength 25 kV/mm
    Waterabsorption <0.01%
    Thermalconductivity 0.33 W/mK
    Hardnessshored 55
    Brittlenesstemperature -70 °C
    Color Natural

    As an accredited Borealis Visico MDPE ME4425/LE4462 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Borealis Visico MDPE ME4425/LE4462 is packaged in 25 kg moisture-resistant polyethylene bags, palletized and shrink-wrapped for secure transport.
    Container Loading (20′ FCL) 20′ FCL container loading: Borealis Visico MDPE ME4425/LE4462 polyethylene resin, palletized bags, evenly distributed, secured, and dry for ocean freight.
    Shipping Borealis Visico MDPE ME4425/LE4462 is shipped as non-hazardous polyethylene pellets in moisture-proof 25 kg bags on pallets or in bulk containers. Keep dry, cool, ventilated, and away from direct sunlight, heat, and ignition sources. Store indoors, protect from moisture and contamination; normal industrial hygiene applies. No special dangerous-goods classification.
    Storage Store Borealis Visico MDPE ME4425/LE4462 in a cool, dry, well-ventilated area away from direct sunlight, heat, flames, and ignition sources. Keep in original sealed packaging on pallets to prevent moisture, dirt, and contamination. Maintain moderate ambient temperatures, avoid prolonged UV exposure, do not stack excessively, and follow local regulations and the supplier’s safety data sheet.
    Shelf Life Shelf life is 24 months from production when stored unopened in dry conditions below 30°C.
    Application of Borealis Visico MDPE ME4425/LE4462

    Aerial Bundled Conductor Insulation: The 0.6/1 kV Overhead Network Case

    The ME4425 two-component silane crosslinkable MDPE system is metered into low-voltage aerial bundled conductor insulation lines where the finished cable must satisfy IEC 60502-1:2021 for 0.6/1 kV operation and withstand outdoor UV ageing. The formulation is locked to a 95:5 weight ratio of ME4425 base compound to LE4462 catalyst masterbatch; the catalyst is dosed by gravimetric feeder at the extruder hopper with a tolerance of ±0.2 wt%, because catalyst starvation below 4.5 wt% disrupts silane condensation network formation and produces under-cured insulation that fails hot set testing after ageing. Extrusion of the insulation layer is performed on a single-screw extruder with an L/D of 24:1 to 30:1, a compression ratio between 3.0:1 and 3.5:1, and an aluminium foil-lined hopper to exclude airborne moisture; barrel temperatures are held between 150°C and 180°C, with melt temperature maintained below 200°C to prevent premature scorch in the screw flights. The insulated conductor is cooled in a water trough and wound onto moisture-barrier pallets; crosslinking proceeds in a steam sauna or hot water bath at 70°C to 90°C for a residence time set by insulation wall thickness and verified by IEC 60811-507 hot set testing at 200°C under 0.2 MPa, with elongation under load no greater than 175% and permanent set no greater than 15%. The final product is carbon black-filled, UV-stabilised XLPE-insulated aerial bundled conductor used in overhead low-voltage distribution networks, where the black MDPE insulation layer retains dimensional stability at continuous conductor temperatures up to 90°C.

    Experience from production-scale lines shows that the main processing bottleneck in this configuration is not extrusion but the moisture-curing step once insulation wall exceeds 1.2 mm; water diffusion through the carbon black-filled MDPE matrix follows a Fickian profile that forces cure tunnel residence time to increase by a factor of approximately four when wall thickness doubles. Thermal runaway in the barrel, often initiated by a worn screw tip or blocked screen pack, creates local temperatures above 200°C and crosslinked gel specks that pass through the screen pack and appear as surface pimples in the final insulation; this failure mode is controlled by monitoring head pressure and melt temperature alarms rather than by increasing screw speed. The ratio of ME4425 to LE4462 must be revalidated after screen pack changes because catalyst-rich zones can form if feeder calibration drifts, leading to variable hot set elongation per IEC 60811-507 and brittle under-cured insulation on the next reel.

    In overhead service drop and street lighting cable insulation, the gravimetric feeder doses 5.0 wt% of LE4462 catalyst masterbatch into ME4425 at a 95:5 ratio, and the tolerance is maintained by in-line weight-per-metre monitoring because drift below 4.5 wt% produces under-cured insulation that fails hot set testing after conditioning. Compliance with IEC 60502-1:2021 for 0.6/1 kV service drop cable and with IEC 60811-501 for mechanical properties is evaluated on samples taken after 24 h of conditioning in 23°C water; the insulation must demonstrate tensile strength of at least 12.5 MPa and elongation at break of at least 200% before and after ageing. The downstream process uses a pressure die with an induction-heated head and a vacuum sizing trough to control eccentricity below 5%; after extrusion, the cable passes through a curing tunnel maintained at 85°C and 80% relative humidity, with line speed adjusted so that insulation gel content measured by ASTM D2765:2016 exceeds 65%. The final product is an overhead service drop or street lighting cable with a black moisture-crosslinked MDPE insulation layer that remains flexible during installation and does not embrittle under ultraviolet exposure.

    What Limits Extrusion Line Speed Before Premature Scorch Occurs?

    Underground low-voltage distribution cable insulation in continuously wet trench environments is fabricated with the same 95:5 ME4425 to LE4462 let-down ratio, but the processing window is narrower because insulation wall thickness is typically 1.0 mm to 2.0 mm and moisture diffusion becomes the rate-limiting step in crosslinking. The extrusion equipment for this construction is a single-screw extruder with a screw length of 30:1 L/D and a water-cooled feed zone, followed by a long cooling trough and a steam cure chamber; barrel temperatures are profiled from 140°C at the feed throat to 180°C at the die, and melt temperature must not exceed 200°C because the silane graft reacts with residual moisture on the carbon black carrier and forms gel particles that accumulate on the breaker plate. Compliance is assessed against IEC 60502-1:2021 for 0.6/1 kV underground cables, with mechanical properties after wet conditioning evaluated according to IEC 60811-501 and hot set testing according to IEC 60811-507; where a cable specification requires acceptance values after wet ageing, exact thresholds are drawn from the applicable type test, and published data for this compound in aggressive soil simulant is limited. The final product is a black XLPE-insulated underground distribution cable installed directly in soil or duct, where the moisture-cure crosslinked MDPE layer resists water treeing better than thermoplastic low-density polyethylene but is not rated for direct burial in chemically aggressive soils without a protective sheath.

    A second production-scale issue arises when the line is restarted after a brief stoppage: residual heat in the die head can raise melt temperature above 200°C within 3 min to 5 min, and the silane graft can react with moisture adsorbed on the carbon black surface to form gel particles that block the die land. Operators therefore purge with a low-melt-index polyethylene before shutdown and restart with a slow screw ramp to avoid a pressure spike. The moisture-cure step for underground cables is validated by gel content extraction per ASTM D2765:2016, and where wall thickness exceeds 2.0 mm, specified cure time in 80°C water is extended by a diffusion-derived factor; published data for this specific configuration is limited, so each construction requires a floor trial with thermocouple-in-insulation cure monitoring rather than reliance on a fixed line speed.

    For control and instrumentation cable insulation in industrial plant trays, the compound is extruded as a thin-wall layer with a target thickness of 0.4 mm to 0.8 mm, and the LE4462 catalyst masterbatch is metered at 5.0 wt% via a miniature gravimetric feeder fitted to a 20:1 L/D single-screw extruder. The screw speed is set to limit melt temperature to 175°C to 190°C; a vacuum vent is not used because the compound is moisture-sensitive, and the hopper is blanketed with dry nitrogen at a dew point below -40°C. Melt flow rate of the base compound is checked per ISO 1133-1:2022 with a 2.16 kg load at 190°C; batch-to-batch variation outside the supplier band indicates residual moisture or catalyst dispersion problems. The downstream process employs a thin-wall pressure die and a water cooling trough followed by an ambient cure rack in a controlled room at 50% to 60% relative humidity, with cure completion verified by hot set testing per IEC 60811-507. Control cable compliance is assessed under IEC 60502-1:2021 for the 0.6/1 kV rating and, where flame retardance is specified, the black MDPE insulation is used only under a flame-retardant sheath tested to IEC 60332-1-2; the MDPE layer itself is not a flame-retardant compound and should not be specified as a fire-performance insulation. The final product is a screened control or instrumentation cable with moisture-crosslinked MDPE insulation for petrochemical, water treatment, and power plant tray installations, where the insulation resists wet condensation but is not exposed to continuous conductor temperatures above 90°C.

    When Building Wire Retrofits Require Moisture-Cured XLPE Without Peroxide Decomposition Products

    Building wire insulation produced from the ME4425 system is specified for humid retrofit installations where the cable must meet IEC 60502-1:2021 for rated voltages up to 0.6/1 kV, and where the installer requires a moisture-cured XLPE insulation without peroxide decomposition residues in the polymer matrix. The compound is prepared at the extruder by adding 5 parts of LE4462 catalyst masterbatch to 95 parts of ME4425 base resin, with the ratio checked every 30 min by gravimetric throughput logging; deviations outside ±0.3 wt% trigger automatic shutdown of the extrusion line. The downstream process uses a single-screw extruder with an L/D of 24:1 and a compression screw of 3.2:1 compression ratio, a core tube die, and a water bath held at 40°C to 60°C for initial cooling before the cable enters a curing chamber at 80°C and 85% relative humidity. The final product is a single-core or multi-core building wire with a black moisture-crosslinked MDPE insulation layer that meets the mechanical and hot set requirements of IEC 60811-501 and IEC 60811-507; the insulation is not intended for direct exposure to oil or ester-based hydraulic fluids, and those environments require an additional sheath.

    When water treatment plant cable insulation must withstand prolonged immersion and intermittent chlorine-containing humidity, ME4425 is processed on a 30:1 L/D single-screw extruder with a dual-wall die for a 0.7 mm nominal insulation wall, using a 95:5 let-down ratio and a melt temperature of 165°C to 185°C; the line includes a closed-loop water curing trough maintained at 75°C for rapid silanol condensation. The insulation is tested for hot set elongation and permanent set according to IEC 60811-507, and the finished cable is evaluated under IEC 60502-1:2021 for 0.6/1 kV operation in wet and humid plant areas; the black MDPE compound contains sufficient carbon black for UV stabilisation but is not formulated for chlorine dioxide disinfection baths, so those installations require a chemically resistant oversheath. The final product is a moisture-crosslinked MDPE-insulated power cable for immersion, pump, and valve applications in water treatment facilities, where the insulation must withstand continuous wet service but is not suitable for direct contact with strong oxidising agents.

    Free Quote

    Competitive Borealis Visico MDPE ME4425/LE4462 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@sinochem-nanjing.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    Top