| HS Code | 273914 |
| Material Type | Peroxide crosslinked polyethylene (PE-Xa) |
| Color | Blue |
| Density | 0.955 g/cm3 |
| Melt Flow Rate 190 C 2 16 Kg | 2.0 g/10 min |
| Crosslinking Degree | >70% |
| Tensile Strength At Break | >20 MPa |
| Elongation At Break | >400% |
| Thermal Conductivity | 0.40 W/mK |
| Coefficient Of Linear Thermal Expansion | 1.4e-4 1/K |
| Specific Heat Capacity | 2.0 kJ/kgK |
| Water Absorption | <0.01% |
| Service Temperature Range | -40°C to +95°C |
| Maximum Operating Pressure | 10 bar at 95°C |
As an accredited Borealis BorPEX PE-Xa HE2558 Blue factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Borealis BorPEX PE-Xa HE2558 Blue is supplied in 25 kg moisture-proof polyethylene bags, palletized and clearly labeled. |
| Container Loading (20′ FCL) | A 20′ FCL dry container loaded with palletized Borealis BorPEX PE-Xa HE2558 Blue, securely strapped and wrapped for ocean transport. |
| Shipping | Shipping description: Borealis BorPEX PE-Xa HE2558 Blue, crosslinkable polyethylene compound, non-hazardous plastic pellets. Not classified as dangerous goods for road, sea, or air transport; no UN number required. Ship in sealed, moisture-resistant bags or containers. Protect from heat, sunlight, moisture, and contamination; avoid prolonged UV exposure. |
| Storage | Store Borealis BorPEX PE-Xa HE2558 Blue in a cool, dry, well-ventilated area, protected from direct sunlight, UV, heat, moisture, and contamination. Keep in original sealed packaging, away from ignition sources and incompatible materials. Avoid prolonged high temperatures and physical damage; use oldest stock first. Do not store outdoors or near oxidizing agents. Observe local regulations and manufacturer’s SDS/label instructions. |
| Shelf Life | Typical shelf life is six months when stored dry, below 30°C, in original sealed packaging, and away from direct sunlight. |
Monolayer pipe extrusion from Borealis BorPEX PE-Xa HE2558 Blue is specified for potable hot and cold water distribution where the finished pipe is certified under ISO 15875 in Europe and ASTM F876/F877 in North America. The peroxide crosslinking route creates carbon–carbon bridges between adjacent polyethylene chains; gel content determined by ISO 10147 is maintained above 70 % after the crosslinking tunnel, because lower gel fractions produce local regions with reduced environmental stress crack resistance under chloraminated potable water. Chlorine resistance is evaluated under continuous-flow oxidative testing according to ASTM F2023, where time to failure is compared with the pipe manufacturer’s regression curve. In service, the pressure-temperature rating of the extruded pipe is based on long-term hydrostatic strength extrapolation according to ISO 9080; typical continuous operating temperatures for potable hot water are 60 °C to 70 °C, with short-term excursions to 95 °C permitted only within the declared class limits. Extruder barrel temperatures must remain below the peroxide decomposition onset specified for the compound; premature decomposition inside the screw generates microgel particles that create surface roughness, dimensional instability, and reduced burst pressure in ISO 1167 hydrostatic tests. The compound does not require hopper drying under normal closed-warehouse conditions, but condensation from cold outdoor storage should be removed with dehumidified air at 60 °C for 2 h to 4 h before start-up. Cold-expansion joining of the crosslinked pipe is standard for potable systems; the network must exhibit sufficient crosslink density to recover from expansion ratios on the order of 15 % to 25 % without splitting. The pipe is not rated for compressed air or fuel gas service, and compatibility with oxidative disinfectants above drinking-water residual concentrations must be validated by site-specific testing.
| Code | Scope | Relevant test condition |
|---|---|---|
| ISO 15875-1 | General requirements for crosslinked polyethylene pipe systems | Classification of PE-Xa material |
| ISO 15875-2 | Pipe dimensions and physical characteristics | Wall thickness, SDR, appearance |
| ISO 1167 | Thermoplastics pipes for fluid conveyance | Hydrostatic pressure resistance at 20 °C, 60 °C, 95 °C |
| ISO 9080 | Plastics piping systems for hot and cold water | Long-term hydrostatic strength extrapolation |
| ISO 10147 | Crosslink density measurement | Gel content by solvent extraction |
| ASTM F876/F877 | US requirements for PEX tubing systems | Potable hot and cold water distribution |
| ASTM F2023 | Oxidative resistance of PEX tubing | Hot chlorinated water exposure |
Radiant floor heating circuits are less demanding in peak temperature than radiator systems, but they impose sustained hoop stress at supply temperatures between 35 °C and 45 °C for operating lifetimes that may exceed 50 years. The governing failure mode is slow crack growth initiated by residual stresses at pipe-to-fitting connections and at bending radii below 5×D, where D is outer diameter. In barrier pipe constructions, the base HE2558 Blue layer is coextruded with an EVOH oxygen barrier attached via polyolefin tie layers; the oxygen permeation limit of the finished multilayer pipe is tested under DIN 4726 at 40 °C, and the accepted value for barrier pipe is below 0.1 g/(m³·d). The crosslinking step must produce a uniform gel fraction through the wall because oxygen barrier pipe has a maximum barrier-layer elongation limit; local under-crosslinked regions show higher thermal expansion and lower creep resistance, causing long-term barrier-layer cracking at the pipe bend. In production, the crosslinking tunnel is profiled so that the pipe surface receives sufficient heat without degrading the outer EVOH layer; infrared pyrometers monitor surface temperature continuously and line speed is trimmed when deviation exceeds the validated profile window established during qualification. Hydrostatic design stress for floor heating pipe is assigned by the pipe manufacturer after 8760 h testing at 60 °C and 95 °C under ISO 1167.
Outdoor hydronic snow- and ice-melting systems embed PE-Xa circuits in concrete or asphalt at depths of 50 mm to 100 mm, requiring the pipe to tolerate thermal expansion of the slab, variable wetting, and intermittent freeze-thaw cycling. The heat-transfer fluid is typically a propylene glycol-water mixture at 30 vol% to 40 vol%; above 50 vol% glycol, heat capacity declines and pump head increases, while below 25 vol% freeze protection becomes inadequate in exposed manifolds. Supply temperatures rarely exceed 45 °C in snow-melting service, but the pipe must withstand repeated thermal cycling between cold start-up and short design heat loads without losing burst strength. Because the pipe is buried in a large thermal mass, the extruded wall must be free of gel defects; microgel clusters formed during premature peroxide decomposition act as stress concentrators when the slab contracts at night. The blue compound provides no additional protection in this application; its function is identification of the hydronic circuit in junction boxes. Piping runs should be pressure-tested with water at 1.5 times the design pressure for 24 h before the slab is poured, following local plumbing code, and then tested again after curing to detect construction damage.
Low-temperature district heating networks operating with supply water at 60 °C to 70 °C and return water below 45 °C use flexible polymer service pipes in pre-insulated twin-pipe or single-pipe configurations. Under these conditions, PE-Xa derived from HE2558 Blue is evaluated for continuous operating pressure at design life by the ISO 9080 regression curve rather than by short-term burst alone. The compound’s blue colour marks the heating-water flow or return line when two blue and red or two blue and black pipes are installed in the same casing, reducing the chance of cross-connection at the manifold. District heating service pipe is frequently installed in drained conduits or buried directly in wet soil; external HDPE insulation casing protects the pipe from mechanical damage, but the service pipe must tolerate axial movement and occasional condensation on the outer surface. Because the crosslinked network is not thermoplastic, butt fusion is not applicable; mechanical compression fittings or press fittings are used, and the pipe ends must be re-rounded after cutting. During heat-up after commissioning, the pipe expands and may require expansion loops or anchor spacing designed for the actual temperature difference between installation temperature and service temperature. The maximum continuous operating temperature is declared by the pipe manufacturer and is normally limited to 70 °C at the design pressure for this service class; short-term excursions above 80 °C are accepted only when the system pressure is reduced according to the pipe rating curve.
Radiant cooling and chilled-water distribution in commercial and residential buildings circulates water at 16 °C to 18 °C, usually above the indoor dew point to prevent condensation on panel surfaces. The extruded PE-Xa pipe is installed in ceiling plaster or wall panels, where oxygen ingress is less severe than in buried floor pipe but still present in open hydronic circuits. Crosslinked polyethylene has lower thermal conductivity than copper, so design software uses a thermal resistance value for the pipe wall; wall thickness and SDR must be entered consistently with the extruded pipe dimensions. In cooling mode, the pipe operates under low mechanical stress, but the system still requires hydrostatic testing to 1.5 times the design pressure because hidden leaks in ceiling voids cause long-term building damage. The blue base layer is acceptable for closed chilled-water loops when the system is protected by an external oxygen barrier or corrosion inhibitor, but it is not by itself an oxygen diffusion barrier. Water treatment should maintain pH between 8.0 and 9.0 and dissolved oxygen below 0.1 mg/L in closed loops to avoid pitting corrosion of metal components.
Closed-loop hydronic heating and cooling circuits with ferrous pumps, steel panels, and mixed-metal fittings require the finished pipe to include an oxygen barrier layer, and the coextrusion of an EVOH layer over Borealis BorPEX PE-Xa HE2558 Blue is performed in a dedicated multilayer die before the thermal crosslinking step. The EVOH layer is not crosslinked by the peroxide route and must be protected from moisture absorption, which is why specific pre-drying of EVOH resin and a low-stress die gap are maintained. The pipe structure typically consists of an inner PE-Xa base layer, a polyolefin tie layer, an EVOH oxygen barrier, a second tie layer, and an outer polyethylene skin; the adhesion between the EVOH and tie layers is measured after crosslinking because residual peroxide decomposition products and heat can plasticise the EVOH and reduce interfacial strength. Production lines for barrier pipe use a coextrusion head with spiral mandrel distribution, and the melt temperature of the outer layer is kept below the peroxide decomposition onset while the crosslinking tunnel is set to deliver heat rapidly enough to crosslink the thicker base layer but not so high that the EVOH exceeds its degradation limit. The finished barrier pipe is tested to DIN 4726 for oxygen diffusion at 40 °C; the maximum oxygen permeation rate is 0.1 g/(m³·d), and a single batch may require destructive testing of the layer thickness distribution through the pipe circumference. This coextruded structure is the standard configuration when HE2558 Blue is converted into pipe for embedded floor heating, radiator connections, and snow-melting circuits with steel manifolds.
Competitive Borealis BorPEX PE-Xa HE2558 Blue prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!