| HS Code | 258792 |
| Productname | Borealis Borlink XLPE LE4244 |
| Manufacturer | Borealis |
| Polymertype | Peroxide crosslinkable polyethylene |
| Chemicalfamily | Polyethylene |
| Application | High-voltage cable insulation |
| Crosslinkingmethod | Peroxide crosslinking |
| Density | 922 kg/m³ |
| Meltflowrate | 2.0 g/10 min at 190°C/2.16 kg |
| Dielectricconstant | 2.3 at 50 Hz |
| Dissipationfactor | 0.0002 at 50 Hz |
| Volumeresistivity | 1e15 Ω·m |
| Tensilestrength | 25 MPa |
| Elongationatbreak | 500% |
| Hotsetelongation | 100% at 200°C |
| Gelcontent | 80% |
| Moisturecontent | ≤200 ppm |
| Thermalconductivity | 0.25 W/m·K |
| Meltingpoint | 110 °C |
| Pelletform | Cylindrical pellets |
| Color | Natural |
| Processingmethod | Extrusion |
| Crosslinkingtemperature | 180-200 °C |
As an accredited Borealis Borlink XLPE LE4244 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Borealis Borlink XLPE LE4244 is supplied in 25 kg moisture-barrier polyethylene bags, 40 bags per 1,000 kg pallet. |
| Container Loading (20′ FCL) | 20-foot FCL container loaded with palletized Borealis Borlink XLPE LE4244 compound, properly secured and labeled for ocean transport. |
| Shipping | Borealis Borlink XLPE LE4244 is shipped as a non-hazardous solid polyethylene compound in moisture-protected bags/octabins on pallets. Keep dry, cool, and away from direct sunlight; avoid humidity and contamination. No special dangerous-goods classification applies for normal transport. |
| Storage | Store Borealis Borlink XLPE LE4244 in a cool, dry, well-ventilated area, ideally below 30°C, away from direct sunlight, heat, ignition, and oxidizers. Keep in original, tightly closed packaging to prevent moisture ingress and contamination. Avoid elevated temperatures and physical damage; use clean, segregated storage, first-in/first-out rotation, and follow the supplier SDS. Do not store near food or feed. |
| Shelf Life | Shelf life is typically 6 months from production when stored unopened in original packaging, dry, below 30°C, and protected from sunlight. |
In 0.6/1 kV building distribution conductors, Borealis Borlink XLPE LE4244 is specified where the insulation wall must survive installation bending at low ambient temperature and continuous conductor temperatures up to 90 °C. Under IEC 60502-1:2021 and HD 603 S1:2016/A3:2021, the compound is used as the primary insulation on copper conductors from 1.5 mm² to 50 mm²; nominal insulation thickness follows the rated voltage and conductor size, typically 0.8 mm for 1.5 mm² cores and 1.4 mm for 35 mm² cores. The formulation addition ratio is 100% undiluted pellet feed; clean uncrosslinked edge trim may be re-fed at ≤5% by weight only when a gravimetric blender maintains ±0.5% batch accuracy. Pellet density and melt flow rate are controlled by ISO 1183-1:2019 and ISO 1133-1:2022 respectively, because viscosity drift alters head pressure before the scorch margin is detected. Downstream processing begins with 95 °C conductor preheating, followed by a 60 mm single-screw extruder with 24:1 L/D and a low-work metering screw; barrel zone temperatures are held at 110/115/120/120/120 °C so that melt temperature does not exceed 125 °C ahead of the crosshead. The melt enters a dry-curing continuous vulcanisation tube pressurised with nitrogen at 0.8–1.2 MPa; tube temperatures of 250–280 °C trigger peroxide decomposition and crosslink formation while the inert atmosphere limits surface oxidation. After the CV tube, the core is water-cooled in two stages, dried, and spark-tested at 3.5 kV AC to detect insulation pinholes. The terminal product class includes single-core 450/750 V building wire, three-core and five-core 0.6/1 kV distribution cable, and meter-tail insulation where the cured XLPE is protected by a PVC or halogen-free outer sheath.
For automotive primary-wire lines, ISO 6722-1:2021 and OEM specifications such as LV 112-1 define Class B and Class C primary cables with insulation wall thicknesses from 0.20 mm to 0.35 mm on copper strands of 0.35 mm² to 1.5 mm². In this application the compound is processed as 100% ready-to-extrude pellets; downstream addition of dicumyl peroxide, antioxidant, or scorch retarder is not required, and regrind of clean cured-skin-free edge trim is limited to ≤3% to preserve thin-wall melt homogeneity. If regrind is used, the blend is verified by melt flow rate under ISO 1133-1:2022 at 190 °C/2.16 kg before line approval. The downstream process uses a 30 mm single-screw extruder with 24:1 L/D, a pressure-assisted crosshead, and a tip/die set dimensioned for the conductor outer diameter; melt temperature is held at 120 °C ± 5 °C to balance viscosity against premature peroxide decomposition. Conductor preheat at 80–100 °C removes residual drawing lubricant and water, reducing interfacial void formation at the copper-polymer boundary. The covered core enters a horizontal CV tube at line speeds constrained by the scorch limit of the compound, not solely by screw output; at wall thicknesses below 0.25 mm, the residence-time distribution in the crosshead becomes the dominant process variable, and head-pressure fluctuations greater than ±0.5 MPa are an early indicator of melt-temperature deviation. Terminal product types include ISO 6722-1:2021 Class B 105 °C primary wire for engine compartments, 600 V chassis wiring, and automotive sensor leads terminated into sealed connectors.
In photovoltaic DC string cable construction, EN 50618:2014 and IEC 62930:2017 regulate crosslinked insulation for 1.5 kV DC photovoltaic string cables, where the insulation layer is positioned beneath a halogen-free flame-retardant sheath. The compound is applied at 100% pellet feed on tinned copper conductors of 2.5 mm², 4 mm², and 6 mm²; the insulation wall thickness is typically 0.5 mm for 4 mm² conductor, while the outer LSZH sheath contributes the remaining mechanical and flame protection. No external peroxide or silane-grafting additive is added at the cable line; the pre-formulated peroxide system is already dispersed in the polyolefin matrix. The extrusion process uses a 45 mm extruder with a 24:1 L/D low-compression screw, feed-zone temperature 110 °C, and die temperature 120 °C, followed by a dry-curing CCV tube at 0.8–1.0 MPa nitrogen pressure. Curing is verified by the hot set test in IEC 60811-507:2012 at 200 °C and 0.2 MPa; typical acceptance limits are elongation under load ≤175% and permanent set ≤15% after cooling. Cured specimens are also tested to IEC 60811-501:2012 for tensile strength and elongation at break. The finished cable is subjected to damp-heat ageing of 1000 h at 85 °C and 85% relative humidity under EN 60068-2-78, followed by insulation resistance measurement in water at 80 °C, to detect migration or interfacial hydrolysis defects. Terminal products include UV-exposed PV string cables designated H1Z2Z2-K, array jumpers, and DC home-run cables installed in cable trays or directly buried in conduit.
When appliance hook-up wire replaces PVC, UL 758 AWM Style 3173/3266 and IEC 60227-1 cover internal wiring insulated with crosslinked polyolefin where PVC plasticizer migration into polystyrene or polycarbonate housings is unacceptable. The formulation addition ratio for appliance lines is 100% compound; no external plasticizer, heat stabilizer, or filler is added, so volatile outgassing during service is limited to low-molecular-weight peroxide decomposition residues. A 20–30 mm extruder with 20:1 L/D and a thin-wall crosshead applies insulation of 0.20 mm to 0.45 mm over copper strands; melt temperature is capped at 125 °C, and the core is cured in a horizontal CV tube. Terminal product types include refrigerator compressor lead wire, range internal harness wire, and printed-circuit board connection leads where insulation heat deformation is tested by IEC 60811-509:2012. Published data for this specific configuration is limited, so production qualification relies on lot-specific hot set and elongation checks rather than generic process recipes.
For shipboard control circuits rated 0.6/1 kV, the compound is used as a core insulation under IEC 60092-350:2020 and NEK 606:2016 mud-resistant cable requirements. Tinned copper conductors of 0.75 mm² to 2.5 mm² are insulated at 100% pellet feed, with nominal walls of 0.8 mm for 1.5 mm² cores; no halogenated flame-retardant filler or antimony trioxide is introduced into the insulation layer, which keeps the insulation contribution to acid-gas release below the limit in IEC 60754-1:2011 when tested behind the LSZH bedding and sheath. The fibres are laid up in pairs or triples, individually foil-shielded, and protected by a thermoset inner sheath before braid armour and a halogen-free outer sheath are applied. The insulation is applied on a CCV line with a 60 mm extruder at 120 °C ± 5 °C melt temperature, then cured in a pressurised steam or nitrogen tube; steam curing is permitted but requires longer venting to remove water from the core before cabling. Terminal goods include shipboard automation twisted pairs, offshore wind turbine nacelle control leads, and engine-room instrument loops where the compound is not exposed to UV without an outer sheath.
The upper line-speed boundary in 0.6/1 kV distribution cable extrusion is set by flow-induced scorch rather than screw plasticising capacity. High-speed production of 1.5–10 mm² distribution cable insulation poses a specific failure mode: polymer melt stagnating at the breaker plate edge or in the crosshead annulus accumulates heat through viscous dissipation, initiating localised peroxide decomposition and producing hard gel flakes that appear as insulation protrusions. The compound is processed undiluted at 100% pellet feed, with clean edge trim restricted to ≤5%; any higher regrind fraction raises melt viscosity and increases the residence time in the extruder, narrowing the scorch margin. A 60 mm single-screw extruder with 24:1 L/D and a pressure-relieved screen pack of 40/80/40 mesh is used; barrel profile is 105/110/115/120/120 °C, and melt temperature is measured at the head with a flush-mounted thermocouple to detect deviations above 125 °C. Head pressure is maintained between 18 MPa and 28 MPa; prolonged operation above 30 MPa signals blocked screens or inadequate zone temperature control. The dry-curing tube pressure of 0.9–1.2 MPa suppresses void growth from gaseous peroxide byproducts during crosslinking, while tube temperature is stepped from 220 °C to 260 °C to avoid surface overcure before the core reaches full cure. Hot set testing to IEC 60811-507:2012 at 200 °C/0.2 MPa and optical inspection of the cured surface are used to reject scorch-related inclusions. Terminal products are continuous lengths of 0.6/1 kV low-voltage distribution cable for infrastructure feeders and industrial building mains.
Competitive Borealis Borlink XLPE LE4244 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!