    • Product Name: Borealis Borlink XLPE LE0500
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: sales8@sinochem-nanjing.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 180166
    Material Crosslinkable polyethylene (XLPE)
    Density 0.922 g/cm³
    Melt Flow Rate 2.0 g/10 min at 190 °C/2.16 kg
    Tensile Strength 20 MPa
    Elongation At Break 400%
    Melting Point 110 °C
    Volume Resistivity 1 × 10^16 Ω·cm
    Dielectric Constant 2.3 at 50 Hz
    Dissipation Factor 0.0005 at 50 Hz
    Dielectric Strength 30 kV/mm
    Thermal Conductivity 0.3 W/m·K
    Water Absorption <0.1%
    Color Natural
    Form Pellets

    As an accredited Borealis Borlink XLPE LE0500 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Borealis Borlink XLPE LE0500 is supplied in 25 kg sealed, moisture-resistant bags, palletized and shrink-wrapped for transport.
    Container Loading (20′ FCL) Borealis Borlink XLPE LE0500 is container-loaded in 20′ FCL using palletized bags, dry stowage, and secure lashing for safe transport.
    Shipping Borealis Borlink XLPE LE0500 is shipped in original, sealed, moisture-barrier packaging as dry pellets on pallets. Keep dry, cool, and protected from sunlight, heat, and contamination. Avoid damaged bags and prolonged humidity exposure. Handle per the SDS; normal transport is non-hazardous when packaged correctly.
    Storage Store Borealis Borlink XLPE LE0500 in a cool, dry, well-ventilated area away from direct sunlight, heat, ignition sources, and oxidizing agents. Keep in original sealed packaging to protect from moisture, dust, and contamination. Avoid prolonged UV exposure and observe first-in/first-out stock rotation. Follow the safety data sheet and local regulations for safe storage.
    Shelf Life Typically 12 months from production when stored in original unopened packaging, dry, below 30°C, and protected from direct sunlight.
    Application of Borealis Borlink XLPE LE0500

    On single-screw extrusion lines for 0.6/1 kV low-voltage power cable, Borealis Borlink XLPE LE0500 is supplied as a pre-compounded peroxide-curable polyethylene pellet with the cure system already dispersed in the matrix. The melt temperature at the die is held between 115 °C and 125 °C; at sustained stock temperatures above 130 °C the dicumyl peroxide component enters a steep half-life reduction regime, moving from approximately 10 h at 117 °C toward 1 h at 135 °C. A conventional single-screw extruder with an L/D ratio of 24:1 to 30:1 and a low-compression screw is used because melt homogeneity must be achieved without imposing excessive shear work. Head pressure is monitored before the breaker plate; a sustained deviation greater than 5 % from the clean-screen baseline is treated as an early sign of pre-crosslinking in the die land. The insulation layer is applied over copper conductors conforming to IEC 60228 Class 1 or Class 2 and then crosslinked in a dry continuous vulcanization tube. The curing line balances line speed, tube temperature, and die-drawn distance so that the component meets the hot-set acceptance window referenced in IEC 60502-1 and tested according to IEC 60811-507: a 200 °C load at 0.20 MPa for 15 min produces elongation under load no greater than 175 % and permanent set no greater than 15 %. Steam curing at 1.0 MPa is used on some production lines, but the moisture exposure changes the surface conductance of the insulation and requires a post-curing water-content check before jacketing.

    After crosslinking, tensile testing is conducted to IEC 60811-501; IEC 60502-1 sets a minimum tensile strength of 12.5 MPa and a minimum elongation at break of 200 % for XLPE insulation. Shrinkage is tested to IEC 60811-502; values above 4 % are considered nonconforming on many 0.6/1 kV cable designs. Continuous conductor temperature is limited to 90 °C, and the short-circuit conductor temperature may not exceed 250 °C for up to 5 s. Production experience shows that batch-to-batch variability in pellet bulk density and peroxide dispersion appears as hot-set elongation scatter rather than as a melt-flow shift. Conductor samples are therefore taken from the start, middle, and end of a cable run; a spread greater than 20 % between adjacent samples triggers a line-speed correction or die-temperature adjustment unless the conductor preheat setting has drifted. Conductor preheat above 80 °C at the head narrows the safe processing window because it raises the melt surface temperature, particularly for insulation walls below 0.7 mm.

    Because LE0500 is not a flame-retardant formulation, the insulation layer in sheathed power cables is normally combined with a separate flame-retardant bedding or sheath compound when the finished cable must pass IEC 60332-1 or IEC 60332-3 flame propagation tests. In unjacketed single-core installations, the circuit design and installation method, rather than the insulation alone, determine compliance with fire propagation requirements.

    Does a 0.6 mm Control-Cable Wall Expose Residence-Time Limits in Peroxide XLPE Extrusion?

    Control and instrumentation cable insulation is extruded over smaller conductors and thinner radial walls than low-voltage power cable insulation. At a wall thickness of 0.6 mm over a 1.5 mm² Class 2 copper conductor, screw speed is increased to maintain output, but the melt in the head adapter may experience a longer near-static residence time along the mandrel and die surfaces. Scorch is therefore not eliminated by high line speed; it is shifted to boundary layers where heat transfer from the hot metal is highest. In high-speed control-cable production, crosshead tooling with chrome-plated surfaces and a parabolic pressure channel is used to minimize dead spots. The melt should not remain above 120 °C for more than 20 min in the head assembly. Under such conditions, dicumyl peroxide decomposition becomes measurable before the melt exits the die, and the pressure drop across the filter pack rises by 3–5 % at constant screw speed, producing surface roughness or tear marks in the extrudate.

    After curing, control-cable cores are tested for tensile properties to IEC 60811-501 and hot set to IEC 60811-507 under the same 200 °C/0.20 MPa condition. Cold bend is evaluated to IEC 60811-504 and cold elongation to IEC 60811-505 to verify that the crosslinked network does not create a brittle low-temperature response. Volume resistivity is measured at 20 °C and after water immersion; values above 10¹⁵ Ω·cm are typical for clean XLPE, but surface contamination and entrapped moisture during multi-core assembly reduce installed insulation resistance more than bulk polymer conductivity. Reels are therefore conditioned at 60–70 °C in a vacuum dryer before jacket extrusion, and pellet moisture content above 0.1 % by weight is treated as a process deviation when the cable is destined for damp industrial environments.

    Because fixed-installation building wire is frequently pulled through conduit at ambient temperatures below 5 °C, the crosslinked polyethylene insulation must retain cold elongation while still meeting 450/750 V construction rules. Borlink XLPE LE0500 is extruded over solid copper conductors in the 0.5 mm² to 16 mm² range to produce single-core non-sheathed cables conforming to BS EN 50525-2-21. The compound is cured to the same hot-set limits as power-cable insulation, but smaller conductor sizes require a different balance between conductor preheat and water-trough temperature. Excessive conductor preheat above 80 °C creates low wall-thickness eccentricity and increased shrinkage after coiling, whereas insufficient preheat produces a rough core surface at the die exit and increases the risk of pinholes during conductor bending. In-line diameter gauges maintain the insulation wall with a tolerance of ±0.05 mm on sizes below 2.5 mm². Tensile strength, elongation, hot set, and shrinkage are tested to BS EN 50525-2-21; when the installation standard requires a single-wire flame propagation test, the finished wire is also subjected to IEC 60332-1.

    When ISO 6722 Thin-Wall Primary Cable Uses a Peroxide-Cure Polyethylene Insulation Layer

    Automotive primary wire insulation produced from crosslinkable polyethylene is tested under ISO 6722-1 for long-term heat ageing, fluid resistance, and abrasion. Because LE0500 is a peroxide-curable system, the insulated conductor is crosslinked before cut-to-length processing. The typical wall thickness for automotive primary wire ranges from 0.20 mm to 0.40 mm depending on conductor size, which places a strict limit on die swell and surface smoothness. Melt temperature at the die is held in the lower part of the permissible range, between 115 °C and 120 °C, because thin walls transfer heat quickly from the hot copper conductor and because higher melt temperature produces pre-scorch nodules in the pressure zone that appear as periodic lumps on the finished wire. The heat-ageing test selected from ISO 6722-1 is based on the final conductor temperature class; published data for LE0500 in thin-wall automotive configurations is limited, so each wire manufacturer validates the compound at its own target temperature class and wall thickness. Tensile strength and elongation retention are measured after oven ageing and evaluated against the class-specific limits in ISO 6722-1, not against generic XLPE limits.

    Fluid resistance is evaluated with the test liquids defined in ISO 6722-1, including reference fluids such as IRM 902 and IRM 903. Crosslinked polyethylene is generally resistant to paraffinic fluids and battery acid at the concentrations used in automotive harness testing, but aromatic hydrocarbons and certain brake fluids reduce elongation at break if the insulation contains internal voids. Pellet moisture must therefore remain below 0.05 %; otherwise pores form after cure and act as stress concentrators. In-line spark testing at 2.5 kV to 5.0 kV depending on wall thickness identifies pinholes and eccentricity faults before the wire is twisted into harnesses.

    Marine and Offshore LV Insulation, Moisture Ageing, and Hot-Set Retention

    Low-voltage marine cable insulation is qualified under IEC 60092-350 electrical and mechanical requirements, with additional fire-performance tests governed by IEC 60332-3-22 for multi-cable bunches. LE0500 is used as the insulation layer beneath a flame-retardant sheath, not as the fire-suppressing outer layer. In marine installations, the insulation must resist long-term humidity and occasional exposure to hydraulic oils, engine-room distillates, and salt spray. Hot-set testing after accelerated moisture ageing is therefore used as a batch-release check; the sample is exposed to 85 °C and 85 % relative humidity for 1000 h before the 200 °C/0.20 MPa hot-set test. Any increase in permanent set above the 15 % limit indicates that the amorphous phase has been plasticized or that surface crosslink density is no longer sufficient. Marine cable extruders commonly run LE0500 with a screen pack of 80/120/200 mesh to remove gel particles that would otherwise nucleate pinhole-type defects under wet conditions.

    After insulation, marine cables are laid up and armored; the core outer diameter and surface hardness determine the deformation resistance during armoring. XLPE insulation with a Shore D hardness in the low 40s is common after crosslinking, but if the hot-set permanent set drifts upward the surface softens and becomes vulnerable to steel-wire bedding pressures. For this reason hot-set specimens are cut from the outermost part of the insulation and from the conductor interface; a large difference between the two locations indicates a through-wall cure gradient caused by insufficient dwell time in the vulcanization tube. Published data for LE0500 in specific marine cable designs is limited, so type testing under IEC 60092-350 includes the full thermal and mechanical program rather than reliance on generic hot-set values alone.

    In underground LV distribution cables, moisture is an operating variable rather than an accidental condition. The insulation layer is processed with the same hot-set acceptance limits, but the belt or wire armour and outer sheath are selected to resist water ingress. To reduce the risk of insulation-boundary defects, the extruder is run with a slightly negative screw cooling on the metering zone and a melt pump to maintain constant head pressure; pressure ripple above ±1 bar on gear-pump discharge lines creates periodic wall-thickness variation. The finished cable is subjected to a water immersion voltage test described in IEC 60502-1 or the applicable national variant before dispatch.

    Free Quote

    Competitive Borealis Borlink XLPE LE0500 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@sinochem-nanjing.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    Top