Products

Avient Therma-Tech™ NJC-8500 Nylon 12

    • Product Name: Avient Therma-Tech™ NJC-8500 Nylon 12
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: admin@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    Specifications
    HS Code 572894
    Material Nylon 12
    Specific Gravity 1.47 g/cm³
    Thermal Conductivity 1.0 W/m·K
    Tensile Strength 45 MPa
    Elongation At Break 2.0%
    Flexural Modulus 8.5 GPa
    Flexural Strength 70 MPa
    Heat Deflection Temperature 1 82 Mpa 115 °C
    Melting Temperature 178 °C
    Volume Resistivity 1.0 × 10^13 ohm·cm
    Dielectric Strength 15 kV/mm
    Flame Rating V-0

    As an accredited Avient Therma-Tech™ NJC-8500 Nylon 12 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Therma-Tech™ NJC-8500 Nylon 12 is supplied as pellets in 25 kg moisture-resistant bags, palletized for safe transport.
    Container Loading (20′ FCL) 20′ FCL container loading of Avient Therma-Tech™ NJC-8500 Nylon 12: palletized bags, securely stowed, weight optimized, moisture-protected, ready for transport.
    Shipping Avient Therma-Tech™ NJC-8500 Nylon 12 ships as a granular thermoplastic compound in sealed bags or drums to prevent moisture absorption. Store in a dry, cool area away from direct sunlight. Avoid excessive heat or humidity. Standard ground freight applies; no special hazard classification required.
    Storage Store in a cool, dry area away from direct sunlight, heat sources, and open flames. Keep the original sealed container to prevent moisture absorption, which can degrade properties. Avoid exposure to excessive humidity and temperature fluctuations. Maintain temperatures below 50°C (122°F) and ensure adequate ventilation. Handle with care to prevent contamination and physical damage.
    Shelf Life Shelf life is typically 2 years from manufacture date when stored in original, unopened packaging in a cool, dry area.
    Application of Avient Therma-Tech™ NJC-8500 Nylon 12

    When a Die-Cast LED Heat Sink Is Replaced in Forward Lighting

    Conversion of an ADC12 aluminium low-beam module heat sink to NJC-8500 is gated by through-plane thermal impedance rather than in-plane conductivity. For a 60 mm × 35 mm sink body with 2.5 mm wall stock, thermal impedance measured under ASTM D5470-17 at 0.5 MPa clamp pressure is the release criterion. The aluminium reference typically falls below 0.4 cm²·K/W; thermally conductive PA12 compounds of this class require a gate-boundary design that avoids freeze-off before packing pressure reaches the rear of the mould. During moulding, melt temperature is maintained at 210 °C to 230 °C, mould temperature at 60 °C to 70 °C, and screw L/D between 20:1 and 24:1. A two-platen hydraulic press with 1200 kN clamp force is used for prototype lots. Drying at 80 °C for 4 h to residual moisture ≤ 0.10 wt% is mandatory; moisture above 0.15 wt% produces splay at the gate and reduces surface finish after black laser-marking. Regrind levels greater than 15 wt% are not used in the screw boss area because filler breakage lowers tensile strength and fastening torque retention. The terminal part is a low-beam heat sink carrier with screw bosses for direct LED board attachment. Compliance is checked against ISO 16750-4:2010 thermal shock from −40 °C to 105 °C, and creep resistance is evaluated by ISO 899-2:2003 at 80 °C under 5 MPa constant stress. The compound is not processed in equipment previously used for unplasticized PVC without purging; residual acid release causes PA12 chain scission.

    Overmolded nickel-plated copper busbars in automotive battery modules expose the polymer to metal insert temperatures up to 130 °C during transfer and to thermal shock from −40 °C to 125 °C. In a busbar retainer with 2.0 mm wall sections, injection is run with an 1800 kN clamp force press, 40 mm/s injection speed, 85 MPa packing pressure, and 4 s hold time. Edge gates positioned opposite the thickest busbar ribs produce filler orientation parallel to the heat path into an aluminium collector plate. The compound’s low equilibrium water absorption at 23 °C and 50% RH, typically 0.2 wt% to 0.3 wt% for PA12 under ISO 62:2008, reduces post-moulding dimensional drift compared with PA66. At busbar slot walls, 20 wt% regrind is the maximum allowed; for colour-stable lots, a 2 wt% carbon black masterbatch is pre-mixed only where UV exposure is specified. The finished component is a busbar retainer and cell-sensing wire channel that must pass creepage and clearance coordination according to IEC 60664-1:2020 and CTI testing under IEC 60112:2020. If the design requires a 600 V comparative tracking index, the final part must be tested because thermally conductive filler systems can shift the result below the unfilled PA12 baseline. The material should not be dried in hoppers containing residual nylon 6,6 pellets; mixing of dissimilar polyamides creates crystalline regions that reduce thermal conductivity at the interface.

    Baseline processing limits for initial tool trials
    ParameterSet pointReference or condition
    Drying temperature80 °Cdesiccant drier, dew point ≤ −30 °C
    Residual moisture0.10 wt%ISO 15512:2019
    Melt temperature210 °C230 °Cnozzle thermocouple
    Mould temperature60 °C70 °Cwater unit setpoint
    Screw L/D20:124:1general purpose screw
    Back pressure0.3 MPa0.5 MPahydraulic injection unit
    Injection velocity25 mm/s45 mm/slinear screw speed
    Cushion3 mm5 mmscrew position after hold

    What Limits Through-Plane Conductivity at Weld Lines in LED Board Carriers?

    In edge-lit panel light engines, two flow fronts meet around ejector pins and bosses; the weld-line region in a thermally conductive PA12 carries higher thermal resistance than the bulk. In-mould melt fronts at 220 °C and a 60 °C mould temperature meet after approximately 3.5 s; the resultant weld-line through-plane conductivity can be 40% to 60% lower than bulk conductivity. This reduction must be accounted for by placing fasteners, not LED junction pads, over the weld zone. Gate sequencing with a valve-gate hot runner delays the second gate by 0.5 s to shift the weld line into a non-heat-spreading rib. The terminal part is a 350 mm × 18 mm LED board carrier with integrated screw bosses and power-supply cable routing. Mould-filling simulation is calibrated to MVR measured under ISO 1133-1:2022 at 230 °C and 2.16 kg, but because filled PA12 is strongly shear-thinning, the simulation requires Cross-WLF parameters from capillary rheometry under ISO 11443:2021. Surface roughness at the LED seat must not exceed 1.6 μm measured by ISO 21920-2:2021. Sinusoidal temperature cycling for the installed sign is evaluated according to IEC 60598-1:2024; the polymer housing is not to be exposed to temperatures above 110 °C at the LED pad for more than 5000 h unless accelerated thermal ageing data at 125 °C is available.

    A brushless power-tool motor end cap exposes the thermally conductive compound to stator lamination temperatures of 80 °C at the axial stop face and to periodic torque pulses from gearbox engagement. The compound is evaluated as a heat spreader and bearing retainer in a 22 mm bearing journal. The injection moulding process uses a 2.5 mm gate, melt temperature 225 °C, mould temperature 70 °C, and fill time 1.5 s. Back pressure is limited to 0.5 MPa to avoid overheating the melt and degrading the internal lubricant package. The finished end cap must satisfy IEC 60335-1:2020 and IEC 60112:2020 CTI above 600 V when the part separates live stator windings from the gearbox. The polymer should not be press-fitted onto shafts with interference greater than 0.10 mm at room temperature because notch sensitivity increases in thermally conductive compounds. If an insert bonding agent masterbatch is used at 1 wt% to improve metal adhesion, through-plane thermal conductivity must be re-checked under ASTM D5470-17; published data for this specific bonding-agent configuration is limited.

    Final part verification matrix
    PropertyTest methodCondition
    Through-plane thermal conductivityASTM D5470-170.5 MPa, 2 mm specimen
    Tensile strengthISO 527-1:20195 mm/min
    Flexural modulusISO 178:20192 mm/min
    Heat deflection temperatureISO 75-2:2013 Method A1.8 MPa
    Water absorptionISO 62:200824 h, 23 °C
    Volume resistivityIEC 62631-3-1:2016500 V DC
    Comparative tracking indexIEC 60112:2020solution A
    FlammabilityUL 940.8 mm3.0 mm

    Coolant-Plate Baffle Integrity Under Low-Temperature Pressure Cycles

    Non-metallic coolant-plate baffle inserts require a combination of thermal conductivity and dimensional stability in a 50/50 vol% water-glycol environment. The baffle plate directs coolant through a 3.5 mm channel; the moulded part is tested for internal leak tightness at 150 kPa after 50 cycles from −40 °C to 85 °C. Leak detection is performed with a helium mass spectrometer at a rejection limit of 5 × 10⁻⁷ Pa·m³/s. Hot-plate welding with a platen temperature of 240 °C, heating time 8 s, and weld displacement 0.8 mm is preferred; the heat-affected zone must not extend beyond 1.5 mm from the weld joint, otherwise thermal conductivity drops near the seam. The finished baffle insert is installed in a battery cooling plate and must satisfy coolant resistance under ASTM D543-21 after 1000 h at 80 °C. Long-term hydrolysis data for this specific grade in glyoxal-containing coolant packages are limited; a 500 h pressure ageing test at 85 °C is required before series release. Regrind content is held at 0 wt% for the weld flange because particle contamination causes porosity at the fusion line. The desiccant dryer set point is 80 °C for 6 h when warehouse RH exceeds 60%; residual moisture is measured under ISO 15512:2019.

    HVAC compressor terminal blocks are overmoulded in single-cavity tools with brass pin inserts at 2.0 mm spacing and wall stock of 2.0 mm. The thermally conductive PA12 is selected to draw heat from the terminal tabs into the compressor body; barrel temperature is maintained at 225 °C, mould temperature at 65 °C, injection speed at 30 mm/s, and packing pressure at 60 MPa for 3 s. The terminal block must achieve the required UL 94 classification at 0.8 mm and meet dielectric strength under IEC 60243-1 at 12 kV/mm. Comparative tracking index is evaluated according to IEC 60112:2020 using test solution A; because some thermally conductive fillers reduce tracking resistance, the final part is not approved solely on unfilled PA12 reference data. The assembly is evaluated for motor-compressor safety under IEC 60335-2-34:2021. The material is incompatible with direct contact with refrigeration oils containing aromatic amines at temperatures above 90 °C; chemical resistance must be verified using the production refrigerant and oil combination. A 5 wt% regrind addition is permitted in the terminal block after three consecutive lots show no measurable shift in MVR under ISO 1133-1:2022; regrind above 10 wt% is not used in pin-bearing sections.

    Free Quote

    Competitive Avient Therma-Tech™ NJC-8500 Nylon 12 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615365186327

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Avient Therma-Tech™ NJC-8500 Nylon 12 is an injection-molding-grade thermally conductive polyamide 12 compound whose filler system is designed for heat-dissipation components that require lower moisture uptake and better chemical resistance than thermally conductive polyamide 6 or polyamide 6/6 grades. The compound belongs to Avient’s Therma-Tech portfolio, which uses the NJC prefix for nylon-based thermally conductive systems; the 8500 series designation is manufacturer-specific and ties to the formulation, filler topography, and melt viscosity target. Because nylon 12 is the matrix resin, the material exhibits the polyamide group’s characteristic sensitivity to moisture before melt processing, but its equilibrium moisture uptake under ISO 62 conditions of 23 °C and 50 % RH is lower than that of nylon 6 and nylon 6/6. This difference becomes relevant in humid service environments where dimensional stability and retention of thermal contact pressure are required.

    Application windows include injection-molded LED heat-sink housings, sensor brackets, and thermally managed enclosures where net-shape molding and electrical isolation are more important than metal-level thermal conductivity. Thermal conductivity is direction-dependent because of filler orientation. The through-plane thermal conductivity is typically lower than the in-plane value, so thermal resistance calculations should use the minimum supplied lot value or the appropriate orientation-specific data from the certificate of analysis. The grade is not a direct substitute for aluminum or copper in high-flux power electronics; thermal conductivity of thermally conductive thermoplastics is generally in the 110 W/mK range, whereas metals exceed 100 W/mK.

    How Does Filler Orientation Govern Through-Plane Thermal Conductivity?

    Thermally conductive fillers with high aspect ratio align along the melt flow front during mold filling. As a result, thermal conductivity measured parallel to flow differs from thermal conductivity measured through the wall thickness. The through-plane value is commonly determined by ISO 22007-2 or by laser flash diffusivity combined with specific heat and density according to ASTM E1461, while thermal interface resistance is measured by ASTM D5470. These methods do not report identical values because contact resistance and anisotropic filler orientation are handled differently. A single datasheet value without a stated test direction is insufficient for application engineering; thermal design calculations should use the lowest orientation-specific conductivity from the supplier lot data.

    Representative envelope for thermally conductive polyamide 12 grades; not a substitute for NJC-8500 lot-specific certificate of analysis
    Property Representative class range Test method
    Density 1.401.60 g/cm³ ISO 1183-1
    Tensile strength 3050 MPa ISO 527-2
    Flexural modulus 25 GPa ISO 178
    Heat deflection temperature at 1.8 MPa 60120 °C ISO 75-2
    Through-plane thermal conductivity 110 W/mK ISO 22007-2 / ASTM E1461
    Volume resistivity for dielectric formulations 10^910^14 ohm·cm IEC 62631-3-1

    In production heat-sink geometries with weld lines, filler alignment is disrupted. This is observed on injection-molded plaques with two gates; the weld-line zone shows lower through-plane conductivity than adjacent material because filler platelets align parallel to the weld-line plane rather than across the heat-transfer path. The exact reduction is part-dependent and cannot be taken from a simple ratio. Prototype validation should compare thermal resistance across the actual knuckle or weld zone using ASTM D5470 with controlled bond-line thickness. Cavity pressure sensors on the production tool are more reliable than laboratory plaque data for detecting the orientation-induced fill variation that shifts weld-line position. If the heat source is placed across a weld line, the component should be rejected or redesigned; accepting the surrounding bulk conductivity as representative creates an unverified thermal bottleneck.

    Melt Processing Parameters, Pre-drying Thresholds, and Tool-Temperature Boundaries

    Nylon 12 compounds require moisture control before melt processing. For filled nylon 12 systems, supplier processing guides commonly specify pre-drying at 80 °C for 4 h in a desiccant dryer with a dew point of -40 °C or lower, to achieve a moisture content not exceeding 0.10 wt% when measured by ISO 15512 or Karl Fischer titration. In manufacturing lines using unheated hopper dryers, final moisture content can remain above 0.10 wt% under ambient relative humidity greater than 60 %, leading to hydrolysis and viscosity loss during melt residence. The screw recovery time becomes unstable when melt temperature falls below the supplier’s lower processing limit, and unmelted filler agglomerates can produce local thermal conductivity loss that is not visible on the part surface.

    High-aspect-ratio fillers are sensitive to screw velocity and back pressure. On a 25 mm to 40 mm injection unit with a general-purpose screw and 3:1 compression ratio, low back pressure is often required to avoid excessive filler attrition that reduces in-plane conductivity. Mold temperature should be maintained within the supplier’s specified range; for nylon 12 grades, tool temperatures of 40 °C to 80 °C are common, but exact settings for NJC-8500 should be taken from the certificate of analysis. A deviation of more than 15 % from the validated fill pressure under constant mold conditions signals moisture variability, feedstock contamination, or regrind-induced viscosity shift. In-mold pressure monitoring is therefore a more useful process control metric than melt temperature alone.

    When process conditions cause excessive filler attrition, the damage is not always visible on the molded part. Thermal conductivity measured on ground powder or heavily reground material should not be used to qualify thermal performance because particle size reduction and prior heat history alter filler aspect ratio and matrix molecular weight. The only valid qualification is on molded plaques or components using the same gate geometry, wall thickness, and melt residence time as the production part. For wall sections below 1.5 mm, cavity pressure may be influenced by filler orientation and should be charted against part mass. The coefficient of linear thermal expansion should also be measured according to ISO 11359-2 if metal inserts are used, because the mismatch between the nylon 12 compound and aluminum or copper can generate stress cracking after thermal cycling.

    When Chemical Resistance Requirements Exclude Glass-Reinforced Nylon 6/6

    Polyamide 12 has lower equilibrium moisture absorption than polyamide 6 and polyamide 6/6 under ISO 62 standard atmosphere of 23 °C and 50 % RH. Typical unfilled nylon 12 absorbs approximately 0.7 wt%; nylon 6/6 absorbs approximately 2.5 wt%. Published data for this specific NJC-8500 configuration is limited because high filler loading dilutes the polyamide fraction but does not fully eliminate moisture-induced dimensional change. When the application is exposed to automotive coolant, salt spray, or high-humidity enclosures, nylon 12-based thermally conductive grades are often specified in preference to nylon 6/6 grades where dimensional stability and chemical stress-crack resistance are needed. This is particularly relevant for outdoor LED lighting and sensor housings.

    However, nylon 12 remains a polyamide. It is not acceptable for continuous service in hot concentrated acids, strong bases, or polar solvents such as methanol without validation. Chemical compatibility should be assessed using ISO 22088 or equivalent stress-cracking tests with molded specimens under the actual fluid concentration and temperature, not extrapolated from unfilled nylon 12 data. In addition, thermally conductive fillers can change the diffusion path length and introduce interfacial regions that alter chemical resistance relative to unfilled polymer. A component exposed to both thermal load and chemical spray should be tested after thermal cycling, not only on as-molded plaques.

    In the broader class of thermally conductive compounds, PPS-based grades provide higher heat deflection temperature and lower moisture absorption than nylon 12 grades, but require melt temperatures in the 300 °C to 340 °C range and therefore demand higher heater band capacity and corrosion-resistant screws. Metal heat sinks provide thermal conductivity greater than 100 W/mK, but they require secondary machining, fastening, and electrical ground paths; a nylon 12 thermally conductive compound can be net-shape molded with dielectric isolation. The NJC-8500 grade should not be positioned as a direct metal replacement in high-flux power electronics; single-digit W/mK thermal conductivity is orders of magnitude lower. The selection boundary is determined by the heat source power density, ambient temperature, and available conduction area, calculated using the minimum through-plane thermal conductivity from the CoA and a contact thermal resistance measured via ASTM D5470.

    For Dielectric Heat-Sink Applications, Surface Resistivity and UL 94 Classification

    Thermally conductive compounds are not necessarily electrically insulating. Graphite or carbon-fiber fillers can raise thermal conductivity but also decrease volume resistivity. The NJC-8500 designation should be treated as a commercial grade code only; electrical performance for the specified lot must be confirmed by IEC 62631-3-1 or ASTM D257 on conditioned plaques at 23 °C and 50 % RH. In humid environments, surface resistivity can drop if the molded part surface absorbs moisture, but nylon 12 absorbs less moisture than nylon 6/6 and may provide more stable resistivity. The exact surface resistivity depends on mold surface finish, colorant package, and filler type.

    If the application specifies UL 94 V-0, the exact thickness and color must be printed on the UL Yellow Card; no universal flammability statement can be made for all wall sections. A 1.5 mm black specimen may meet V-0, while the same grade at 0.8 mm natural may not. Fire-retardant additives can reduce thermal conductivity and mechanical strength; users should not assume a flame-retardant version of NJC-8500 retains the same thermal performance without separate data. For electrically isolated heat-sink applications, the dielectric strength should be tested according to IEC 60243-1 on a specimen of the molded thickness, because dielectric strength decreases with increasing specimen thickness and with filler content.

    Standard designations and measured properties for lot acceptance
    Measured property Standard designation Application relevance
    Density ISO 1183-1 / ASTM D792 Mass prediction, filler loading consistency
    Tensile properties ISO 527-2 Structural load resistance
    Flexural modulus ISO 178 Heat-sink fin rigidity
    Heat deflection temperature ISO 75-2 Short-term upper use temperature
    Melt volume-flow rate ISO 1133-1:2022 Injection molding process consistency
    Thermal conductivity ISO 22007-2 / ASTM E1461 Thermal management design
    Thermal impedance ASTM D5470 Interface resistance measurement
    Volume resistivity IEC 62631-3-1 / ASTM D257 Dielectric isolation verification
    Flammability UL 94 Enclosure safety compliance
    Moisture content ISO 15512 Pre-drying verification

    RoHS 2011/65/EU Annex II concentration limits apply to homogeneous materials, not to a finished assembly. The supplier’s REACH SVHC declaration should be requested for the specific production lot; a generic statement based on the polymer family is insufficient. In automotive ecosystems, materials may need to be evaluated under OEM-specific volatile organic compound and fogging tests such as VDA 278; published data for this specific configuration is limited if not included in Avient’s documentation. Because thermal conductivity is not a design constant, thermal interface resistance between the molded part and the heat-generating component should be measured with the intended thermal interface material and clamping pressure. The part’s surface flatness, as molded, affects contact resistance; polished cavity surfaces produce lower interface resistance than textured surfaces. Molded-in stress from uneven cooling can warp thin heat-sink fins and increase contact resistance after assembly, so cavity pressure and packing profile should be optimized on the production tool, not on a laboratory plaque.

    Top