Products

Americhem ABS ColorRx ABS-0700RX

    • Product Name: Americhem ABS ColorRx ABS-0700RX
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 202633
    Material Type Acrylonitrile Butadiene Styrene (ABS)
    Density 1.04 g/cm³
    Melt Flow Rate 3.0 g/10 min (220 °C / 10 kg)
    Tensile Strength At Yield 40 MPa
    Tensile Elongation At Break 20%
    Flexural Modulus 2.2 GPa
    Notched Izod Impact Strength 20 kJ/m²
    Heat Deflection Temperature At 1 8 Mpa 85 °C
    Vicat Softening Temperature 100 °C
    Rockwell Hardness 105 R
    Ul 94 Flammability Rating HB
    Processing Method Injection Molding

    As an accredited Americhem ABS ColorRx ABS-0700RX factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Americhem ABS ColorRx ABS-0700RX is supplied in 25 kg moisture-barrier bags, securely palletized for industrial shipping and storage.
    Container Loading (20′ FCL) For 20′ FCL, Americhem ABS ColorRx ABS-0700RX is palletized, shrink-wrapped, strapped, and loaded in a dry container for export.
    Shipping Americhem ABS ColorRx ABS-0700RX is shipped as a non-hazardous, non-regulated solid in sealed original packaging. No UN number, hazard class, or packing group applies. Keep dry, avoid excessive heat, protect from contamination, and handle as a general industrial solid during normal truck, rail, or ocean freight.
    Storage Store Americhem ABS ColorRx ABS-0700RX in a cool, dry, well-ventilated area away from direct sunlight, heat, sparks, and flames. Keep containers tightly closed to prevent moisture and contamination. Avoid prolonged UV exposure and excessive stacking. Maintain good housekeeping to control dust, rotate stock, and follow the manufacturer’s SDS and local regulations.
    Shelf Life Americhem ABS ColorRx ABS-0700RX typically has a 24-month shelf life from manufacture when stored unopened in a cool, dry place.
    Application of Americhem ABS ColorRx ABS-0700RX

    In drug-delivery device housings, Americhem ColorRx ABS-0700RX is typically injection molded on electric toggle presses in the 800–1200 kN clamp force class. The compound’s amorphous structure gives lower and more directionally uniform mold shrinkage than semicrystalline alternatives; toolmakers commonly apply a mold shrinkage allowance of 0.4–0.7 %, with the lower value parallel to flow and the higher value transverse to flow. Melt temperature at the nozzle is maintained between 210 °C and 240 °C. For pre-colored grades, excursions above 250 °C increase the probability of chromophore degradation and hue shift, particularly in molds with long hot-runner residence time. Desiccant drying at 80–90 °C until residual moisture falls below 0.05 % by weight is mandatory because the butadiene phase in ABS hydrolyzes at processing temperatures and produces splay, gate blush, and loss of impact strength. Hot runner manifolds should be externally heated and fitted with low-shear valve gates in the 0.8–1.2 mm diameter range for nominal wall sections between 1.5 mm and 3.0 mm; smaller gates create excessive shear and larger gates delay gate seal and extend cycle time. Pack pressure is set at 40–60 % of injection pressure, and hold time is calculated to seal the gate rather than fixed arbitrarily. In a 2 mm-thick boss with a 0.8 mm wall, gate seal on a valve-gated cold runner commonly occurs after 6–10 s. Mold temperature is controlled by turbulent-flow water temperature control units in the 40–60 °C range; lower values reduce knit-line strength at multi-aperture snap-fit features, while higher values increase cycle time and can alter surface gloss on textured areas. Screw retraction back pressure is kept between 0.5 MPa and 1.0 MPa to disperse colorant without over-shearing the melt. Mold surface texturing from VDI 24 to VDI 36 hides flow lines but increases ejection force; draft angles should be maintained at 0.5–1 ° on textured surfaces to prevent scuffing. The dominant production failure in this housing class is sink opposite snap-fit bosses, which is addressed by increasing pack pressure and boss root radius rather than by raising barrel temperature. Finished-component mechanical verification should compare tensile yield and flexural modulus on specimens conditioned at 23 ± 2 °C and 50 ± 10 % RH according to ASTM D618, with tensile testing per ASTM D638-14 and flexural testing per ASTM D790-17.

    Table 1. Finished-device verification matrix for external healthcare components molded from Americhem ColorRx ABS-0700RX.

    AssessmentStandard / clauseMeasurement conditionAcceptance basis
    CytotoxicityISO 10993-5:2009MEM elution, L929 cellsNot greater than grade 2 reactivity; finished device evaluation required
    SensitizationISO 10993-10:2010Guinea pig maximization or LLNANo sensitization response
    Tensile yield stressASTM D638-1423 ± 2 °C, 50 ± 10 % RHReport value, compare to lot baseline
    Flexural modulusASTM D790-171.3 mm/minReport value
    Melt volume rateISO 1133-1:2022220 °C, 10 kgWithin supplier lot tolerance
    Heat deflection temperatureASTM D648-181.82 MPaReport value
    Environmental stress crackingISO 22088-3:2006Bent strip, 0.5 % and 1.0 % outer-fiber strainNo cracking after 24 h

    What Limits Dimensional Stability in Diagnostic Analyzer Bezel Molding?

    Diagnostic analyzer bezels impose a different constraint set because they are large, flat, and perforated by multiple display windows. Warpage is controlled primarily by packing uniformity, not by barrel temperature. When gate-to-gate spacing exceeds 150 mm, sequential valve gating with delayed opening of 0.5–1.5 s between central and outer gates is used to move the melt front under controlled pressure. The practical flow-length-to-wall-thickness ratio for this grade should remain below 150:1; above that, flow hesitation at ribs and boss islands leads to visible knit lines and reduced impact strength at the weld location. Differential shrinkage between the nominally flat surface and reinforced ribs is the main source of out-of-flatness. Rib thickness should be limited to 50–60 % of the adjacent wall, and gate lands should be placed away from critical display apertures to avoid jetting. Pre-drying to <0.05 % moisture is equally critical because splay in a class-A diagnostic bezel cannot be hidden by texture. For chemical exposure, hospital-grade disinfectants containing quaternary ammonium compounds, diluted hydrogen peroxide, or 70 % v/v isopropanol should be evaluated under strain using ISO 22088-3:2006 bent-strip specimens at 0.5 % and 1.0 % outer-fiber strain for 24 h. Stress whitening or cracking at the 1.0 % strain condition indicates unacceptable retained stress from molding. If flatness specifications are tighter than 0.8 mm over a 300 mm span, the mold should be rebalanced with pressure transducers at each cavity rather than relying on clamp-force increase. Published data for this specific configuration is limited; process capability must be established on the actual tool.

    IV System Structural Brackets and the EtO Sterilization Boundary

    When ethylene oxide sterilization is selected for an IV system structural bracket, the low-temperature process is compatible with the ABS matrix but introduces a warm aeration constraint. Typical EtO cycles expose parts to 45–55 °C and elevated relative humidity for 2–4 h, followed by aeration to reduce residuals below the per-device limit established under ISO 10993-7:2008. Because ABS loses load-bearing stiffness as temperature approaches its heat deflection temperature, bracketed parts under constant spring load should not be placed in an unsupported orientation during aeration; otherwise, creep recovery may be incomplete when the device returns to room temperature. Snap-fit deflection strain should be kept below 2.0 % for external housing clips, and lower if the part will be exposed to disinfection chemicals. Molded-in stress above this level accelerates environmental stress cracking in the presence of isopropanol, quaternary ammonium compounds, or lipid-based soils. The preferred design uses a tapered cantilever with a root radius of 0.5 mm and a thickness that tapers from 1.2 mm at the root to 0.8 mm at the engagement point. EtO residual compliance requires that vents and blind holes are accessible to gas flow; long blind holes below 1.0 mm diameter can trap residual EtO and require extended aeration. Autoclave sterilization is not suitable for load-bearing ABS components because temperatures of 121 °C or 134 °C exceed the material’s practical structural limit under load.

    When Cleanroom Assembly Replaces Mechanical Bonding

    Solvent bonding of this ABS grade in cleanroom assembly shifts the risk profile from mechanical stress concentration to chemical compatibility and joint solvent valuation. Cyclohexanone-based solvents used neat or with 30–50 % methyl ethyl ketone produce rapid softening of the butadiene-rich surface and create low-particulate joints, but residual solvent can migrate to adjacent unjoined surfaces and cause whitening or stress cracking. The bond gap should be controlled between 0.05 mm and 0.15 mm; larger gaps create solvent pooling at the joint root and reduce shear strength. For ultrasonic welding, near-field welding with an energy director height of 0.3–0.5 mm and an included angle of 60–90 ° is preferred for medical ABS; far-field welding of long thin walls damps amplitude and produces inconsistent joint strength. Welding parameters must be revalidated after changing injection molding lot color concentrate because pigment loading affects the loss modulus and heating rate. Adhesive bonding with UV-curable cyanoacrylate is possible only when the adhesive is isolated from service stress and hospital-grade disinfectant exposure. Cyclic shear testing on bonded coupons at 1 Hz for 10,000 cycles at 23 °C generally reveals whether a bonded joint survives vibration during transport; testing can follow ASTM D3163 for lap shear strength of adhesively bonded plastics and ISO 22088-3:2006 for environmental stress cracking. Joint design should not rely solely on the adhesive because ABS molded-in stress at the bond line can cause premature delamination when the assembly is exposed to elevated temperature or disinfectant.

    Dental curing-unit enclosures expose the compound to repeated hospital-grade disinfectants under continuous low-frequency vibration from fans and transformer mounts. The relevant failure modes are surface micro-cracking around molded-in metal inserts and stress whitening at weld lines next to cooling vents. Inserts should be preheated to 80–100 °C before insert molding to reduce the shrinkage differential and delayed cold cracking. Bosses for self-tapping screws should use thread-rolling screws rather than thread-cutting styles because ABS is notch-sensitive; hole diameter should create 50–80 % thread engagement in the boss wall. Surface contact with 70 % v/v isopropanol does not immediately dissolve ABS, but repeated wiping under service stress can initiate environmental stress cracking at high-molded-in-stress regions. Testing should therefore combine ISO 22088-3:2006 bent strips with ASTM D543-21 chemical immersion to capture the effect of disinfectant type and exposure interval. Batch-to-batch color concentrate variation matters in this application because visible haze or whitening at stress points is interpreted as a surface defect even when structural integrity is retained.

    Controlling Gamma-Induced Color Shift in Point-of-Care Monitor Components

    Color shift after radiation sterilization is governed by oxidative damage in the polybutadiene phase. The amorphous ABS matrix can tolerate a standard gamma dose of 25–40 kGy for non-load-bearing point-of-care monitor components, but unpigmented ABS typically shows visible yellowing at these doses. In pre-colored grades, the observed Delta E after irradiation depends on the pigment chemistry, total colorant loading, and antioxidant package; measurement should be made under D65/10 ° illuminant using ASTM D2244-21 on a 50 mm plaque or production part. If a post-sterilization Delta E tolerance is set at 1.5 CIELAB units, unpigmented or lightly tinted ABS may exceed this threshold; opaque medical white or dark chromatic pigments may mask but not prevent underlying oxidation. E-beam sterilization at 25–40 kGy can produce less oxidative yellowing than gamma because the exposure is delivered over a shorter time period, but penetration depth in thick monitor housings must be verified using dose-mapping. The ColorRx pre-colored platform should be evaluated at the maximum labeled dose, not the nominal dose, because color shift is dose-dependent and can vary by 0.5–1.0 Delta E per 10 kGy in sensitive tints. Mechanical property retention after radiation should be verified with ASTM D638-14 tensile and ASTM D256-10 Izod impact tests; radiation-induced loss of notched impact strength is a more likely failure than tensile yield loss.

    Free Quote

    Competitive Americhem ABS ColorRx ABS-0700RX prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Americhem ColorRx ABS-0700RX is a controlled-formulation acrylonitrile-butadiene-styrene grade within the ColorRx medical polymer portfolio. The material is based on a two-phase microstructure in which dispersed polybutadiene rubber particles are embedded in a styrene-acrylonitrile continuous phase; this structure provides the rigidity and impact balance used in rigid medical device housings, handpiece shells, brackets, and accessory components. The 0700 suffix is a manufacturer-specific grade identifier and is not a substitute for a lot-specific certificate of analysis. Physical property declarations should be obtained from the current supplier technical data sheet and verified using ISO 1133-1:2022 for melt flow rate, ISO 527-2:2012 for tensile properties, and ISO 178:2019 for flexural modulus. Because complete published data for this specific product configuration is limited, qualification for a finished medical device should use production-representative lots and the actual sterilization, cleaning, and secondary operations the device will encounter.

    For unfilled ABS polymers, the ranges in the following table are collected from publicly available resin literature and are not guaranteed values for ColorRx ABS-0700RX.

    PropertyTest methodGeneric unfilled ABS range
    DensityISO 1183-1:20191.03–1.07 g/cm³
    Melt volume-flow rateISO 1133-1:20225–25 cm³/10 min at condition specified by supplier
    Tensile stress at yieldISO 527-2:201235–50 MPa
    Flexural modulusISO 178:20191800–2800 MPa
    Notched Izod impactISO 180/A:201910–30 kJ/m²
    Heat deflection temperature at 1.8 MPaISO 75-2:201375–100°C

    What Documented Test Methods Apply to Medical ABS Grades?

    A medical ABS resin is not automatically cleared for any device application. The supplier regulatory package for a ColorRx medical grade is typically organized around component-level biological test summaries rather than device-level approval. Cytotoxicity is commonly evaluated according to ISO 10993-5:2009 using L929 mouse fibroblasts and extract dilutions; sensitization and irritation according to ISO 10993-10:2021; systemic toxicity according to USP <88> Class VI; and material characterization according to ISO 10993-18:2020 for extractables and leachables profiling. The final device manufacturer retains responsibility for risk-based biocompatibility evaluation under ISO 10993-1:2018 because processing aids, colorants, mold release, and secondary operations can alter the chemical leachables profile. In addition, FDA 21 CFR Part 820 applies to device manufacturing quality systems; a resin supplier’s biological test summaries do not replace a device master file or regulatory submission. For materials used in certain food-contact components, FDA 21 CFR 177.1020 may be referenced for ABS polymer composition, but this citation is separate from medical biocompatibility requirements.

    The following matrix defines standard methods commonly requested during supplier qualification; inclusion does not confirm that a specific lot of ColorRx ABS-0700RX has completed every listed method.

    EvaluationStandard or methodTypical endpoint or test article
    CytotoxicityISO 10993-5:2009L929 mouse fibroblasts, extract dilution
    SensitizationISO 10993-10:2021Local lymph node assay or guinea pig maximization
    Intracutaneous reactivityISO 10993-10:2021Polar and nonpolar extracts in rabbits
    Systemic toxicityUSP <88> Class VIIntravenous and intraperitoneal extracts
    Material characterizationISO 10993-18:2020Extractables and leachables profile
    Sterilization dose validationISO 11137-1:2006Bioburden and dose audit
    Ethylene oxide residualISO 10993-7:2008Simulated-use extraction

    Pre-drying is the controlling variable for defect-free molding of this polymer class. A closed-loop desiccant dryer with a dew point below -40°C, a hopper-inlet air temperature of 80°C, and a residence time of 2 h to 4 h is typical for unfilled ABS. The target residual moisture content is usually below 0.10% by weight for injection molding and below 0.05% by weight for extrusion or high-shear thin-wall molding. Residual moisture above these thresholds hydrolyzes the styrene-acrylonitrile continuous phase and generates splay, silver streaks, and loss of surface definition. On production-scale injection machines, barrel profiles are commonly rear 190°C, center 210°C, front 225°C, and nozzle 230°C, with mold temperatures between 40°C and 70°C. These are class-typical starting conditions for unfilled ABS; they must be refined with lot-specific melt viscosity data and the flow-length-to-wall-thickness ratio of the mold.

    Storage conditions for ABS compounds should be dry and ambient, with bags closed when not in use. If a bag has been opened for more than 8 h in an environment above 60% relative humidity, the material should be re-dried before molding. Moisture absorption is controlled at the pellet surface and in the feed throat; hopper dryers with insufficient dew point or inadequate airflow can mask the true moisture condition of the resin. Because ABS pellets can carry static charge, drying hoppers should be grounded, and regrind loading should be controlled to prevent segregation of fines, which can char on the screw and appear as black specks in medical components.

    Processing Envelope and Failure Modes in Injection Molding

    On high-volume lines, the upper processing temperature is limited less by the styrene-acrylonitrile phase than by the polybutadiene rubber particles. Residence times above 250°C for more than 5 min can initiate free-radical oxidation of the butadiene phase, shifting color and reducing impact. Lower melt temperatures below 190°C increase viscosity and create residual flow orientation that lowers chemical stress-crack resistance. Injection pressures from 70 MPa to 140 MPa are generally used, with hold pressure adjusted to 50% to 70% of peak injection pressure; back pressure is typically 0.5 MPa to 1.5 MPa. Clamp force is calculated from projected cavity area and estimated cavity pressure, for which 25 MPa to 40 MPa is a common design estimate for unfilled ABS. Production failure modes include gate blush at sub-0.8 mm gates, jetting at unvented or poorly expanded flow fronts, and weld-line delamination when mold temperature drops below 40°C. Regrind levels above 20% can reduce notched impact unless the regrind is sorted, dried, and blended with documented process capability; the exact allowable regrind fraction must be validated on the intended machine because batch-to-batch variance in rubber particle size distribution influences the result.

    Melt flow rate is a single-point measurement and does not fully capture shear-thinning behavior. For thin-wall components below 1.0 mm, capillary rheometry at shear rates from 100 s⁻¹ to 10,000 s⁻¹, using ISO 11443:2021, is more useful than a single melt flow rate value. Mold-filling simulation should use supplier viscosity curves or equivalent measured data for gate and runner balancing, particularly in multi-cavity tools producing tight dimensional tolerances and in components that will undergo terminal sterilization, where molecular weight shifts can change the viscosity envelope at process boundaries.

    For medical device manufacturing, process validation under ISO 13485:2016 and, where applicable, FDA 21 CFR Part 820 requires documented evidence that the molding process produces components meeting specification. This includes installation qualification, operational qualification, and performance qualification using the actual resin, dryer, screw, mold, and auxiliary equipment. A change in lot, colorant, or regrind level may require re-validation because ABS viscosity and impact properties are sensitive to thermal history.

    When the Finished Device Is Subjected to Ethylene Oxide or Gamma Radiation

    Terminal sterilization selection drives several material constraints. Steam autoclave cycles at 121°C are usually outside the practical continuous-use temperature range of unfilled ABS, because heat deflection temperatures for this polymer class are commonly between 75°C and 100°C at 1.8 MPa. Ethylene oxide sterilization below 55°C is compatible with ABS as a process, but aeration time must be sufficient to meet residual ethylene oxide and ethylene chlorohydrin limits under ISO 10993-7:2008; device geometry, blind holes, and packaging influence aeration. Gamma radiation from cobalt-60 sources at 25 kGy to 40 kGy can cause yellowing and a measurable reduction in notched impact strength through free-radical reactions in the butadiene phase. The controlled stabilizer packages used in ColorRx medical ABS grades are intended to reduce oxidative shift, but lot-specific color stability at the target dose must be confirmed on molded plaques because pigmentation and antioxidant dispersion influence the result. Published data for repeated gamma exposure of this exact product is limited; worst-case cycle testing should be included in design verification if multiple sterilizations are possible.

    Color matching for medical ABS components imposes additional constraints. Color concentrates must be formulated from carriers and pigments appropriate for the intended biocompatibility and regulatory endpoints; industrial masterbatches are not automatically acceptable for skin-contact or tissue-contact applications because carrier resins and dispersants can migrate. The ColorRx platform is designed to supply pre-screened colorant combinations that maintain biological test documentation and lot-to-lot color consistency. Colorimetric tolerances are generally specified in CIELAB coordinates, with delta E values agreed between the molder and the device manufacturer; the exact tolerance should reflect the component’s visual inspection criteria and the lighting conditions used in production. Lot-to-lot color stability for a specific ABS-0700RX color match should be confirmed using molded plaques and the intended drying and processing conditions, because residence time and barrel temperature can shift the color response independently of the colorant package.

    The difference between ColorRx ABS-0700RX and a general-purpose ABS molding grade is primarily in formulation control and documentation infrastructure, not in a fundamentally different polymer backbone. General-purpose ABS may exhibit similar mechanical values, but it is typically sold without biological test summaries, without medical-grade change control, and without raw-material traceability aligned to a device manufacturer’s supplier qualification. ColorRx ABS-0700RX is also distinct from polycarbonate/ABS blends in that its heat deflection temperature and flexural modulus are lower; this can be useful in snap-fit designs that require ductile failure rather than high rigidity. It is not a substitute for PC/ABS where higher autoclave resistance or tighter dimensional stability under load is required, nor is it intended for load-bearing implantable use. Chemical compatibility must be verified with the finished device because ABS is susceptible to environmental stress cracking in ketones, esters, aromatic hydrocarbons, and chlorinated solvents. Cleaning agents, lipid exposures, and drug solvents in combination with molded-in stress can create localized cracking that standard tensile data do not predict.

    Top