| HS Code | 860723 |
| Materialtype | Acrylonitrile Butadiene Styrene (ABS) |
| Density | 1.04 g/cm³ |
| Meltflowrate | 5.0 g/10 min (230°C/3.8 kg) |
| Tensilestrengthyield | 41 MPa |
| Tensileelongationatbreak | 20% |
| Flexuralmodulus | 2.2 GPa |
| Flexuralstrength | 65 MPa |
| Notchedizodimpact | 200 J/m |
| Heatdeflectiontemperature | 82°C at 1.8 MPa |
| Vicatsofteningtemperature | 100°C |
| Flammabilityrating | UL 94 HB |
| Processingmethod | Injection molding |
| Moldshrinkage | 0.5-0.7% |
As an accredited Americhem ABS ColorRx ABS-0500RX factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Americhem ABS ColorRx ABS-0500RX is packaged in 25 kg (55 lb) moisture-barrier bags, with pallet quantities available for bulk shipment. |
| Container Loading (20′ FCL) | Americhem ABS ColorRx ABS-0500RX is securely palletized with moisture protection and loaded into a 20-foot FCL container for export shipment. |
| Shipping | Americhem ABS ColorRx ABS-0500RX is shipped as solid thermoplastic pellets in sealed bags or boxes. It is not regulated for transport under DOT/IATA/IMDG. Keep containers closed, dry, and away from ignition sources; handle according to the SDS. |
| Storage | Store Americhem ABS ColorRx ABS-0500RX in a cool, dry, well-ventilated area away from direct sunlight, heat, sparks, flames, and strong oxidizers. Keep containers tightly closed and labeled, protect from moisture and dust, and use first-in, first-out rotation. Store only in original, intact packaging and follow the supplier’s SDS and local regulations. |
| Shelf Life | The shelf life is 24 months from manufacture when stored unopened in a cool, dry place, protected from moisture and direct sunlight. |
Large-format housings for clinical chemistry analyzers are injection molded from Americhem ABS ColorRx ABS-0500RX with a rear-zone barrel profile starting at 200 °C and rising to 232 °C at the nozzle. The resin is pre-dried in a desiccant-bed dryer at 82 °C for 4 h with a dew point at or below −29 °C and verified to a moisture content no higher than 0.08 % before molding. Mold temperature is held at 43–49 °C for Class A bezel surfaces with SPI A-2 gloss. A 20:1 L/D general-purpose screw with 2.5:1 compression ratio and back pressure of 0.7–1.0 MPa provides melt homogeneity. Injection velocity is set at 60–90 mm/s for wall sections between 2.5 mm and 3.2 mm. Pack pressure is maintained at 55–70 MPa for 3.5–5.0 s until gate freeze-off, and cooling time is 20–28 s depending on boss diameter. Hot runner valve gates with 4 to 8 drops are used in multi-cavity tools over 0.5 m² projected area; for a 0.65 m² diagnostic housing tool, a 550 t–650 t hydraulic press with parallel-closing control is specified to avoid flash at parting-line vent depths of 0.025–0.050 mm. The feed throat is water-jacketed at 40–50 °C to prevent bridging of dried pellets in humid production halls. Regrind from sprues and rejected parts is limited to 20 % by weight; the blend is re-tested for melt flow rate per ISO 1133-1:2022 to confirm a shift no greater than 2 g/10 min from virgin pellets. The finished components are reagent carousel shrouds, drawer fronts, and analyzer bezels that carry IEC 61010-1 enclosure mechanical strength requirements. Surfaces are not intended for continuous patient skin contact, but accessible handles are assessed under ISO 10993-5 when contact duration exceeds 30 min. Resistance to common disinfectant wipes must be validated by ASTM D543 or CLSI M40-A2, particularly where molded-in gate stress intersects snap-fit undercuts.
During cold-chain operation, point-of-care fluorescence reader shells cycle between 4 °C storage and 23 °C assembly environments. With Americhem ABS ColorRx ABS-0500RX, the processor validates low-temperature notched Izod impact at the intended cold-chain boundary using ASTM D256; published data for this specific grade at 4 °C is limited, so a lot-specific verification is required. Drying precedes molding at 80 °C for 4 h to a moisture level not exceeding 0.08 %, with return-air dew-point monitoring set at −32 °C. Barrel temperatures are held between 210 °C and 228 °C, and melt temperature is limited to 222–230 °C to avoid discoloration in thin 1.6–2.0 mm walls. A 30–45 °C tool temperature is selected when snap-fit beams require ductile deformation after cold storage. Injection velocity is raised to 120–180 mm/s and maximum injection pressure is 80–100 MPa to fill narrow latch features without short shots. Pack pressure is maintained at 50–65 MPa for 2.0–3.5 s; transfer from velocity control to pressure control is set at 95 % part volume. Submarine gates with 0.8–1.2 mm diameters are located into non-appearance rear walls so automatic degating does not leave witness marks on contact surfaces. The runner system is a cold runner with reverse-taper sprue puller. Regrind is restricted to 15 % because cold-chain fracture toughness can be sensitive to repeated-thermal-history degradation. ISO 10993-5 and ISO 10993-10 testing is completed on the final part geometry because molded-in stress can alter extractables. The finished assemblies are handheld fluorescence reader shells, docking cradle latches, and battery door tether anchors that must withstand drop at 4 °C without cracking at weld lines.
For infusion pump bezels where fastener bosses consume PCB real estate, ultrasonic welding is used with a shear joint having 0.30–0.45 mm interference and an energy director height of 0.50 mm with a 60° included angle. Americhem ABS ColorRx ABS-0500RX is dried at 85 °C for 4 h and molded with barrel temperatures of 215–230 °C; mold temperature is kept at 48–54 °C to reduce molded-in stress on the weld line perimeter. A 20 kHz welding press with amplitude of 22–28 µm and trigger force of 0.7–1.2 kN is set to a weld time of 0.30–0.60 s and hold time of 0.40–0.80 s. Weld collapse is limited to 0.25 mm; over-weld beyond this depth creates flash on the seal perimeter and reduces joint strength. Because the grade is unreinforced, shear joint interference is kept below 0.45 mm to avoid cracking at the joint root. The welded bezel is evaluated by dye-penetrant leak testing at 34 kPa internal pressure and by tensile pull force of the housing, which must exceed 1.5× the maximum intended handle load. Regrind is limited to 10 % because excessive recycle shifts melt viscosity and alters ultrasonic energy dissipation in the joint. IEC 60601-1 general mechanical shock and IEC 60601-1-11 drop requirements for transportable infusion pumps apply to the finished assembly. The finished products are infusion pump front bezels, display window frames, and battery module housings; the material is not used for parts with wall sections below 1.2 mm because of weld flash and dimensional variation.
In valved holding chambers and dry-powder inhaler actuators, the gate region is the primary source of dimensional drift after ejection. The precolored Americhem ABS ColorRx ABS-0500RX is dried at 80 °C for 4 h in a desiccant dryer with a dew point no higher than −30 °C and processed at a flat barrel profile of 207–220 °C to prevent yellowing of light-tinted custom colors. Mold temperature is set at 38 °C to allow 25–35 s cycles in 8-cavity cold-runner production. Injection speed is 50–80 mm/s; hold pressure is 45–55 MPa for 4–6 s; screw speed is 50–70 rpm at back pressure 0.6–0.8 MPa. A sub-gate with 0.6 mm diameter is placed on the actuator body non-airway surface to reduce gate prominence below 0.05 mm. Cavity pressure sensors at end of fill are set to 35–45 MPa for gate freeze-off detection, and the press transfer position is adjusted to avoid overpacking at the gate. Regrind is limited to 10 % and only from first-pass runners, because actuator body roundness tolerances of ±0.15 mm cannot tolerate viscosity degradation. Dimensional checks are performed on a coordinate measuring machine after 24 h post-molding conditioning at 23 °C and 50 % RH, because ABS can absorb up to 0.3 % moisture by weight and swell slightly before equilibrium. ISO 10993-5 and ISO 10993-10 are evaluated on a worst-case molded actuator to cover mouthpiece contact. The finished components are inhaler actuator bodies, dose-counter windows, and valved holding chamber shells; the grade is used only where the drug path is isolated from the polymer surface.
Reagent door panels and side covers on benchtop laboratory diagnostic instruments are exposed to intermittent levels of IPA, quaternary ammonium compounds, and dilute bleach. Americhem ABS ColorRx ABS-0500RX is molded at 218–232 °C melt temperature with tool temperature of 50 °C for high-gloss panels; wall thickness is 2.3–3.0 mm. Drying is extended to 85 °C for 5 h when ambient relative humidity exceeds 60 %. A hot-runner manifold with externally heated 6 to 12 drops feeds cavity-to-cavity fill balance within 1.5 % of shot weight. Injection velocity is 40–60 mm/s and pack pressure is 58–68 MPa for 5 s. The molded covers are tested for environmental stress cracking by ASTM D543, Method B, with the specific disinfectant concentrate at use dilution. Because ABS can stress crack under strong ketones, chlorinated solvents, and undiluted glycol ethers, design of drainage grooves and molded-in stress concentration at gate bosses is critical. The gate boss sleeve ejector must not leave witness rings on the reagent door show surface; a minimum ejection draft angle of 1.5° per side is used. Regrind is limited to 20 %; mixed-color regrind is not used in light gray or white diagnostic housings due to ΔE00 drift above 0.8. Compliance includes IEC 61010-1 for enclosure mechanical strength and UL 94 HB ignition testing only where the power supply is sealed; if the equipment sits adjacent to an ignition source, a V-0 grade or metal shield is substituted. The finished parts are reagent door panels, side covers, and touchscreen surrounds for immunoassay and hematology analyzers.
When a wearable receiver shell requires short-term skin contact and high cosmetic consistency, the molding strategy shifts from simple fill-and-pack to lot-level colorimetric control. Americhem ABS ColorRx ABS-0500RX is used for patient monitor receiver housings, sensor shells, and belt clips where skin contact is short-term and non-mucosal. The compound is pre-colored by the manufacturer; no external masterbatch is added at the press because a second colorant source would alter the extractables profile documented in ISO 10993-5 and ISO 10993-10 files. Drying is at 82 °C for 4 h with moisture not exceeding 0.08 %. Injection molding is performed on high-cavitation 8- to 16-cavity cold-runner tools with melt temperature at 218–225 °C, mold temperature 40–45 °C, injection pressure 80–95 MPa, and injection velocity 100–150 mm/s. Pack pressure is 60 MPa for 2.5 s and cooling time is 14–18 s for 1.5 mm nominal wall sections. Colorimetric consistency across cavities is verified under D65/10° using a spectrophotometer with specular included; a ΔE00 tolerance of 0.8 is established for cavity-to-cavity control when regrind is limited to 15 % and hold pressure is repeatable within ±2 MPa. The texture depth on skin-contact surfaces is specified as MT-11010, with a draft angle of 1.5° minimum per side to avoid ejection drag marks. Snap-fit arm root radii are held at no less than 0.8 mm to avoid cold-snap fractures during insertion. The finished products are sensor cable housings, receiver bezels, and strap lugs; the material is not used for breached skin, implant, or long-term mucosal contact.
Competitive Americhem ABS ColorRx ABS-0500RX prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Americhem ColorRx ABS-0500RX is identified in supplier-controlled healthcare polymer documentation as a custom-colorable acrylonitrile-butadiene-styrene grade within the ColorRx line. The model string can be separated into the ABS base resin, the series identifier 0500, and the RX suffix associated with the healthcare portfolio. Published data for this specific configuration is limited; therefore the numerical ranges in this document are platform-level values for unfilled medical ABS and are not a substitute for the supplier certificate of analysis. The grade is used in injection-molded, non-implant, short-term body-contact or indirect-contact components such as hand-held diagnostic enclosures, monitoring device housings, and structural covers. Because the polymer alone does not confer device clearance, the finished article is evaluated under a biological risk assessment plan conforming to ISO 10993-1:2018. If a supplier certificate for ABS-0500RX is not available at the time of tooling release, no regulatory claim should be attached to generic platform data.
Moisture control is the first critical threshold. Extended exposure to ambient humidity above 60% relative humidity raises pellet surface moisture and produces splay, nozzle drool, and variable screw recovery. The material should be dried in a desiccant dryer at 80 °C for 2–4 h, with supply air at a dew point of -30 °C or lower. Target moisture content is below 0.05% by weight. In production plants without sealed hoppers, moisture regain can occur before the feed throat even when drying is performed correctly because the transfer hoses, hopper magnets, and feed throat are open to ambient air.
On 80–120 ton all-electric injection molding machines with general-purpose 20:1 L/D screws, the melt temperature is typically held between 210 °C and 240 °C. Rear zones may be set at 190–210 °C, the center zones at 220–240 °C, and the nozzle at 230–240 °C. This gradient limits the exposure of the butadiene phase to high heat in the feed section while providing enough enthalpy for thin-wall filling. A screw with a compression ratio of 2.2:1–2.6:1 and a non-return valve free of dead spots is preferred. A commercially available all-purpose screw is acceptable only if residence time is limited. If the screw is too low in compression, homogenization of the melt is poor and shrinkage variation widens. If the screw is too high in compression, shear heating may exceed the set temperature and initiate thermal degradation.
Mold temperature is often set between 40 °C and 80 °C. The lower end reduces cooling time and cost, but it may produce a dull surface and higher molded-in orientation. The upper end improves gloss and weld-line strength but increases cooling time and may raise post-mold shrinkage in thick sections. Back pressure between 0.3 MPa and 0.7 MPa homogenizes the melt and stabilizes shot weight. Decompression of 3–6 mm limits nozzle drool; cushion is maintained at 3–5 mm to provide consistent packing. Fill speed should be set to produce a nominal fill time of 0.5–1.5 s for a 1.5 mm wall. Excessively slow filling creates jetting and flow marks; excessively fast filling creates shear splay at the gate and may reduce impact by molecular orientation near the skin. A cooling time of 8–15 s is typical for 2 mm nominal wall, but thermal simulation from the mold is required because hot-runner systems, internal cores, and textured surfaces change heat extraction.
Tool design also interacts with property retention. Gates sized for general-purpose ABS may not transfer to a lower-viscosity ColorRx lot without adjustment; a gate diameter that is too small raises shear heating and can cause gate blush. Edge gates of 0.8–1.2 mm thickness are typical for 1.5–2.5 mm walls, while a hot runner with individually controlled valve gates is used for larger diagnostic housings. If the part is textured, a draft angle of at least 1° per side is used on deep cores to prevent ejection drag and stress whitening. Unbalanced runner systems on multi-cavity tools may create cavity-to-cavity variation in packing; process capability studies on the molding floor often reveal more variation from runner balancing than from melt-flow-rate differences between approved lots.
The thermal residence boundary is critical. Interruptions exceeding 5 min at melt temperature can produce brown streaks and carbonized specks from degradation of the butadiene phase. When machine stoppage occurs, barrel temperatures are typically reduced to 150–170 °C or the barrel is purged with a low-viscosity purging compound. Screw recovery time should not drift by more than 10% lot-to-lot; larger drift indicates feed-throat blocking, screw wear, or moisture variation.
The ColorRx designation carries a documentary requirement beyond that of general-purpose ABS. A molder or device manufacturer must verify whether ABS-0500RX is covered by a formulation-lock agreement, change notification procedure, and biocompatibility master file. In healthcare projects, the base polymer is often referenced against FDA 21 CFR 177.1020 for the ABS copolymer, but this clearance addresses food-contact applications and does not establish a medical-device biological endpoint. Cytotoxicity is assessed under ISO 10993-5:2009, sensitization and irritation under ISO 10993-10:2021, and overall biological evaluation planning under ISO 10993-1:2018. The specific extraction conditions, cell types, and dose levels are device-dependent; no polymer grade can be certified generically without the final geometry, processing history, and intended patient-contact duration.
Table 1 presents a compliance matrix for the ColorRx ABS platform as frequently referenced in technical documentation. The status column distinguishes platform-level expectations from grade-specific confirmation.
| Standard or designation | Scope | Status for ABS-0500RX |
|---|---|---|
| ISO 10993-1:2018 | Biological evaluation planning | Finished-device requirement |
| ISO 10993-5:2009 | In vitro cytotoxicity | Device-level confirmation required |
| ISO 10993-10:2021 | Skin sensitization and irritation | Device-level confirmation required |
| ISO 10993-7:2008 | Ethylene oxide residual limits | Required for EtO-sterilized devices |
| USP <87> / <88> | Biological reactivity testing | Cited only if supplier certificate lists the grade |
| FDA 21 CFR 177.1020 | ABS base polymer food-contact clearance | Reference only; not a medical clearance |
| ISO 1133-1:2022 | Melt mass-flow rate determination | Lot-to-lot viscosity control |
Documentation hierarchy matters when comparing ABS-0500RX to a general-purpose ABS. A general-purpose grade may be supported by a standard technical datasheet and a safety data sheet; a healthcare designation is expected to be supported by a formulation-lock letter, a change-control protocol, heavy-metal and residual-volatile statements, and possibly a drug-master-file or device-master-file reference. If these documents are not present, the healthcare designation should be treated as a commercial label rather than a regulatory certification.
For custom-colored versions of ABS-0500RX, color quality control is part of the specification. A tight production color tolerance may be communicated as ΔE*ab below 1.0 under a D65 illuminant and 10° observer, measured with a sphere-based spectrophotometer in reflectance mode. The exact tolerance, backing, and sample preparation geometry are established in the color match letter; meeting the mechanical specification does not by itself guarantee that a molded part will meet the visual acceptance limit under a particular lighting standard.
Molding defects associated with moisture are more common than variability in tensile strength. In plants where ambient relative humidity exceeds 60%, open storage of dried pellets can reintroduce enough moisture within 8 h to create visible splay on a 100 ton machine. Symptoms include silver streaks spreading from the gate, unstable nozzle drool, and screw torque changes. A desiccant-wheel dryer with a sealed hopper, short material-transfer hoses, and hopper magnets that are cleaned at each lot change reduces the failure rate more reliably than increasing barrel temperature. Regrind above 20% amplifies moisture variability and introduces fines that degrade surface appearance and impact. For healthcare parts, regrind is usually prohibited unless the device manufacturer has explicitly qualified a closed-loop regrind stream.
The mechanical plateau of unfilled medical ABS is relatively narrow. Specific gravity typically falls between 1.03 and 1.05 under ISO 1183-1:2019. Tensile yield stress is typically 35–45 MPa under ASTM D638-14, flexural modulus 2.0–2.4 GPa under ASTM D790-17, and notched Izod impact 200–320 J/m under ASTM D256-10 at 23 °C. Heat deflection at 1.82 MPa generally falls between 75 °C and 90 °C under ASTM D648-18e1. Mold shrinkage often ranges from 0.4% to 0.7%, with the exact value influenced by wall thickness, gate geometry, mold temperature, and packing pressure.
Table 2 places these platform values next to material classes that are common alternatives. The table is comparative only; the values for ABS-0500RX must be taken from the supplier specification.
| Material class | Melt processing range | HDT at 1.82 MPa | Notched Izod at 23 °C | Typical sterility method |
|---|---|---|---|---|
| Unfilled medical ABS | 210–240 °C | 75–90 °C | 200–320 J/m | Gamma, EtO; steam limited |
| General-purpose ABS | 210–240 °C | 75–90 °C | 200–320 J/m | Gamma, EtO |
| PC/ABS blend | 240–270 °C | 100–120 °C | 400–600 J/m | Gamma, EtO, limited steam |
| Clear MABS | 210–240 °C | 70–85 °C | 150–250 J/m | Gamma, EtO; steam limited |
A general-purpose ABS may match the mechanical values in Table 2 but lacks the controlled additive and pigment restrictions normally associated with the ColorRx line. The replacement may be mechanically acceptable yet unacceptable from a regulatory standpoint. A PC/ABS blend raises heat resistance and low-temperature toughness but increases melt processing temperature to 240–270 °C and typically requires stricter drying below 0.02% moisture. A clear MABS provides transparency but may lose impact strength at lower temperatures and may have lower resistance to aggressive disinfectants. A glass-filled ABS raises tensile modulus but reduces weld-line strength and increases tool wear; it is not automatically interchangeable with an unfilled grade when the same tooling and gate layout are retained.
Before a tooling change, the molder should compare the melt-volume-flow rate, shrink rate, and color target. A difference in melt flow rate of more than 2 g/10 min may alter filling pressure by enough to create flash or short shots in an existing tool. A difference in mold shrinkage greater than 0.1% may push dimensions outside the tolerance established for the previous material. These comparisons are performed with ISO 1133-1:2022 for melt flow and ASTM D955-08 for shrinkage; data for ABS-0500RX must be retrieved from the supplier certificate, not from generic platform tables.
The butadiene phase in ABS places a thermal and environmental boundary on the product. Because the heat-deflection temperature at 1.82 MPa remains below 90 °C for unfilled platform grades, a steam autoclave cycle at 121 °C operates far above the dimension-stability limit. Gamma irradiation at 25–50 kGy and ethylene oxide are more practical for ABS healthcare components, but the selection must be verified on the molded part because dose rate, part mass, and antioxidant stabilizer package shift the color and impact response. Ethylene oxide residual testing under ISO 10993-7:2008 is required where applicable.
Solvent exposure is a further incompatibility. Ketone-based cleaners, esters, and some aromatic hydrocarbons can craze the surface and reduce impact strength; alcohol-based disinfectants are generally less aggressive but repeated exposure should be evaluated under the device-cleaning protocol. The unfilled ABS grade should not be combined with high-temperature polycarbonate or acetal residues in the same melt stream without an effective purging and cleaning procedure because incompatible melts can create delamination and contamination defects in molded parts.
In relation to other ColorRx products, a polypropylene grade may tolerate steam autoclave cycles better and offers lower density, but it does not match ABS surface hardness and rigidity. A polycarbonate grade offers higher heat resistance, but requires higher melt energy and may exhibit higher molded-in stress. The ABS-0500RX designation is therefore appropriate when the part requires a balance of impact strength, dimensional stability, low melt processing energy, and a healthcare-grade documentation package, and when the service environment is limited to temperatures below the heat-deflection ceiling and to sterilization methods compatible with the butadiene phase.