| HS Code | 511235 |
| Product Name | 3M Temflex 1776 Vinyl Electrical Tape |
| Product Type | Vinyl electrical tape |
| Backing Material | Polyvinyl chloride (PVC) |
| Adhesive Type | Rubber pressure-sensitive adhesive |
| Color | Black |
| Total Thickness | 7 mil (0.178 mm) |
| Width | 3/4 in (19 mm) |
| Length | 60 ft (18.3 m) |
| Voltage Rating | 600 V |
| Operating Temperature Range | 0°C to 80°C (32°F to 176°F) |
| Dielectric Strength | 1,000 V/mil (39.4 kV/mm) |
| Tensile Strength | 15 lb/in (2.6 kN/m) |
| Elongation At Break | 200% |
| Adhesion To Steel | 18 oz/in (2.0 N/cm) |
| Adhesion To Backing | 18 oz/in (2.0 N/cm) |
| Flame Retardant | Yes |
| Ul Listing | UL 510 |
| Csa Certification | CSA C22.2 No. 197 |
| Rohs Compliance | Compliant |
| Shelf Life | 5 years from date of manufacture |
As an accredited 3M Temflex™ 1776 Vinyl Electrical Tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Available in 3/4 in. x 60 ft. rolls; 10 rolls per carton, individually wrapped with 3M Temflex 1776 labels. |
| Container Loading (20′ FCL) | 20′ FCL loading of 3M Temflex™ 1776 Vinyl Electrical Tape, palletized, shrink-wrapped, secured for ocean freight, ensuring dry, damage-free transport. |
| Shipping | Shipping Description: 3M Temflex™ 1776 Vinyl Electrical Tape is not regulated for transport by DOT, IATA, or IMDG. It ships as non-hazardous general cargo with no UN number, hazard class, packing group, labels, or placards. Standard packaging applies; keep dry and avoid extreme heat. No special documentation required. |
| Storage | Store 3M Temflex™ 1776 Vinyl Electrical Tape in its original packaging in a clean, dry, well-ventilated area. Keep away from direct sunlight, heat, moisture, solvents, oils, and oxidizing agents. Maintain moderate temperatures, ideally 16–27°C (60–80°F), and avoid freezing or excessive heat. Do not expose to temperatures above 38°C (100°F). Rotate stock and use within the recommended shelf life. |
| Shelf Life | Shelf life is 5 years from date of manufacture when stored in original packaging at 21°C and 50% relative humidity. |
Within junction boxes serving 120/240 V branch circuits, the tape functions as a mechanical and dielectric overwrap on pre-insulated, listed splicing devices, not as sole insulation on bare conductors. The backing is a plasticized PVC film of 0.18 mm nominal thickness; the adhesive is a rubber-based pressure-sensitive formulation. Compliance in this zone is governed by NFPA 70 Article 110.3(B) (equipment usage per instructions), Article 110.14(B) (terminals and splices), and UL 510 Recognized Component status. The PVC backing and rubber-based adhesive are characterized under ASTM D1000 test methods for tensile, elongation, adhesion, and dielectric breakdown; these properties determine conformation over irregular connector profiles. Process: conductors are joined with a listed splicing device, the joint is inspected for sharp strands, then tape is applied helically with 50% overlap, maintaining light tension so the backing conforms to the irregular profile. A minimum of two half-lapped layers is applied over the connector body, extending at least one tape width beyond each end onto the conductor insulation. The terminal product is a splice overwrap carrying a 600 V dry-circuit rating and a 90°C continuous temperature limit. The half-lapped structure creates a helical creepage interface; the wrap is supplementary, and the splicing device carries the electrical continuity. The wrap resists moisture ingress in damp locations but is not a substitute for a moisture-tight junction box or potting compound. The tape shall not be used to insulate twisted-wire-only splices without a mechanical connector where the joint is load-bearing or subject to vibration.
Field installations along 12 V landscape lighting runs frequently use the tape to seal low-voltage connector bodies against soil moisture and mechanical abrasion. The product's UL 510 Recognized Component status establishes flame retardancy and dielectric integrity, but it does not confer direct-burial or continuous-UV exposure ratings. The backing is plasticized PVC, which undergoes UV-induced dehydrochlorination and plasticizer migration after prolonged sunlight exposure; published data for this specific configuration is limited. Therefore, any splice left above grade shall be overwrapped with an opaque, UV-stable jacket or placed inside a listed enclosure. Process: the connector is wrapped with 50% helical overlap, two layers minimum, with the tape stretched only enough to conform without reducing thickness at the lap edge. Overstretching reduces thickness at the lap edge and can create void paths for moisture ingress. The terminal product is a moisture-resistant low-voltage connector block rated for secondary-circuit use; it is not suitable for line-voltage circuits or for direct burial under NFPA 70 Article 300.5 without additional listed means. The tape operates within a -7°C to 90°C service window; below the lower bound the PVC backing stiffens and the rubber-based adhesive loses tack.
Although color-coded thermoplastic insulation is preferred at the conductor extrusion stage, field-built industrial control panels frequently require conductor identification at the point of termination. NFPA 79 Chapter 13.2.4 permits marking by color at terminations; UL 508A internal wiring requirements incorporate the same identification intent. The tape is used as a color band, not as primary insulation. A 18 mm wide roll is cut into flags or wrapped as a single continuous band around the conductor adjacent to the ferrule or terminal. The backing and rubber-based PSA must not interfere with the secure seating of screw terminals; therefore the band is placed at least 10 mm from the stripped conductor end. For phase conductors, the tape color must match the panel legend and comply with the machine safety circuit color code required by the applicable standard. Grounding conductors shall not be marked with color tape where green/yellow identification is mandated; the marking must not obscure the underlying insulation color. Plasticizer migration from the PVC film can stress-crack polycarbonate terminal markers or ABS wiring duct under long-term contact; the tape band should not be applied directly over these substrates without an intervening polyester label. A common process conflict arises when the 0.18 mm tape thickness is added over a conductor that must pass through a close-fitting wiring duct or wire ferrule. In tight panels, the added thickness may reduce clearance or increase insertion force. The tape shall be applied only at the visible termination section, not along the wire duct length. For conductors larger than 10 mm², banding may exacerbate heat retention at the terminal; the temperature rise test of UL 508A considers the terminal assembly, and the tape band must be limited to one layer to avoid insulating the connection. The terminal product is a termination point with a color-coded identification band that does not reduce creepage or clearance distances under UL 508A spacing rules.
| Application zone | Governing standard | Limiting parameter / boundary |
|---|---|---|
| Building junction box splice overwrap | NFPA 70 110.14(B), UL 510, ASTM D1000 | 600 V dry, 90°C, not sole insulation |
| Outdoor low-voltage landscape connector | NFPA 70 300.5, UL 510 | No direct burial, no continuous UV exposure |
| Control panel phase marking | NFPA 79 13.2.4, UL 508A | Marking only, one layer on conductors > 10 mm² |
| Automotive harness repair | SAE J1128 | Service limit 90°C, not for SXL/GXL above PVC limit |
| HVAC/R motor lead termination | UL 510, NFPA 70 Article 430 | 600 V dry, terminal box max 90°C |
SAE J1128 primary wire is stripped, joined, and sealed with a tape overwrap in aftermarket repair of low-tension automotive harnesses. The tape is applied as an outer bundling and abrasion layer over mechanical crimp or solder joints. The 0.18 mm PVC backing and rubber-based adhesive provide flexibility at -7°C and insulation up to 600 V dry, which exceeds the 50 VDC typical of low-tension automotive circuits. Process: the joint is centered, tape is spiral-wrapped with 50% overlap in two directions to create four layers over the crimp barrel, extending one tape width onto the adjacent wire insulation. Pull tension is kept below the yield point of the backing; excessive elongation causes adhesive thinning at the lap interface. The terminal product is a flexible, abrasion-resistant harness branch that meets the mechanical protection expectation of SAE J1128 but is not a sealed connector; underhood locations above 90°C, direct fuel contact, or continuous oil immersion require a heat-shrink or closed-cell sealing system. The tape is not specified for SXL or GXL crosslinked insulation repair at temperatures above the PVC service limit.
The compressor terminal box presents a temperature cycling range from -7°C to 90°C and exposure to refrigerant oil mist. The tape is applied as the final outer jacket over varnished cambric or rubber insulation on motor lead terminations. Its 0.18 mm PVC backing and rubber-based adhesive maintain dielectric integrity under 600 V dry conditions, which covers most single-phase and three-phase HVAC/R motor leads. Compliance is anchored to NFPA 70 Article 430, UL 510 Recognized Component status, and the motor manufacturer's terminal box instructions. Process: the lead joint is cleaned with a compatible solvent to remove oil, the underlying insulation layer is allowed to cure, then the vinyl tape is half-lapped at 50% overlap in two passes to build a double-layer jacket. The tape is wrapped from the conductor side toward the terminal lug to shed moisture away from the joint. Sharp edges on molded terminal blocks or crimped lug barrels require an underlying cambric tape padding because the PVC film can be cut by vibration-induced abrasion. The terminal product is a motor lead termination with a continuous 90°C-rated outer jacket; it does not provide oil-tight sealing, and continuous immersion in refrigerant oil outside the terminal box is outside the product boundary. Published data for this specific configuration is limited; field verification of dielectric integrity should be performed per IEEE 43 or the motor manufacturer's test procedure.
Competitive 3M Temflex™ 1776 Vinyl Electrical Tape prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
3M Temflex™ 1776 Vinyl Electrical Tape is a general-purpose insulating tape constructed from a plasticized polyvinyl chloride film and a pressure-sensitive rubber resin adhesive. The backing is supplied at a nominal thickness of 0.18 mm (7 mil) and is commonly wound in 19 mm (3/4 in) widths at 20 m (66 ft) per roll. The product is listed under UL 510 and certified under CSA C22.2 No. 197 for use as primary electrical insulation on low-voltage systems not exceeding 600 V. The pressure-sensitive adhesive provides adhesion to steel of 25 oz/in (2.7 N/10 mm) and the backing exhibits 200% elongation at break when tested in accordance with ASTM D1000. The tape is applied as a conformable overwrap for splices, terminations, wire harness bundling, and conductor phase identification. The product’s electrical function is to isolate conductors from adjacent circuits and provide a dielectric barrier at the termination point, not to serve as structural or mechanical reinforcement.
Within the UL 510 framework, polyvinyl chloride insulating tape is assessed for physical properties, flame-retardant behavior, and cold-temperature integrity. The listing does not assign a working voltage by itself; the 600 V limit is a manufacturer-declared system application value consistent with the tape’s function as primary insulation at or below this potential. ASTM D1000 is the principal test method used to characterize thickness, tensile strength, elongation, adhesion to steel, adhesion to backing, and dielectric breakdown voltage. The dry dielectric breakdown voltage of 8,000 V published for the 0.18 mm (7 mil) film is a short-term laboratory test result measured against flat electrodes. It is not an operational voltage rating and does not account for voids, mechanical stress points, or contamination present on a production splice. Flame-retardant behavior is evaluated within UL 510, and the product is suitable for use where a tape must limit flame propagation along a wire bundle. Published data for this specific configuration is limited for post-flame mechanical strength retention and for sustained exposure to hot surfaces above the continuous operating temperature.
Typical manufacturer-published property values for the black tape configuration are shown below.
| Property | Typical Value | Test Reference |
|---|---|---|
| Backing material | Polyvinyl chloride film | — |
| Adhesive type | Pressure-sensitive rubber resin | — |
| Nominal thickness | 0.18 mm (7 mil) | ASTM D1000 |
| Breaking strength | 17 lb/in (3.0 kN/m) | ASTM D1000 |
| Elongation at break | 200% | ASTM D1000 |
| Adhesion to steel | 25 oz/in (2.7 N/10 mm) | ASTM D1000 |
| Adhesion to backing | 25 oz/in (2.7 N/10 mm) | ASTM D1000 |
| Dielectric breakdown voltage | 8,000 V | ASTM D1000 |
| Continuous operating temperature | 80°C (176°F) | Manufacturer specification |
| Working voltage | 600 V | Manufacturer specification |
| Flammability classification | Listed | UL 510, CSA C22.2 No. 197 |
Mechanically, the tape is engineered to provide a balance between tensile strength and conformability for manual bench wrapping and light production use. The 17 lb/in (3.0 kN/m) breaking strength allows moderate tension during application without immediate tearing, while the 200% elongation at break permits the tape to follow the irregular shape of a lug or wire nut. The adhesion values indicate that the rubber resin adhesive bonds to steel and to the PVC backing at the same nominal level. This interlayer adhesion is critical for preventing flagging at the tape end when a splice is wrapped without a final heat-shrink sleeve. However, adhesion on copper or PVC-jacketed conductors may be lower than the steel value if the surface carries oils, mold release, or silicone residues. Published data for this specific configuration is limited in the public domain.
The PVC backing is a thermoplastic compound that derives its flexibility from plasticizer incorporation. Under sustained thermal load near the 80°C continuous operating limit, plasticizer migration from the film to the adhesive layer can occur, which may stiffen the backing and reduce elongation. This is a known degradation pathway for general-purpose vinyl insulating tapes. The rubber resin adhesive is selected for compatibility with the PVC film, but long-term contact with certain low-molecular-weight plasticizers used in other PVC cable jackets can soften the adhesive and reduce shear strength. Published data for this specific configuration is limited for plasticizer exchange in confined splice boxes with mixed PVC jacket types.
The tensile and elongation properties reported under ASTM D1000 are typically determined at a controlled jaw separation rate on a constant-rate-of-extension tensile tester. The specimen width and gauge length influence the reported breaking strength and elongation; the 17 lb/in (3.0 kN/m) value is normalized to unit width, not to cross-sectional area of the film.
Because the backing is a thermoplastic PVC film, the tape’s installed dielectric performance depends on elongation control and adhesive wet-out. On a motor lead splice, a half-lapped wrap creates two layers over the conductor. At a nominal thickness of 0.18 mm (7 mil) per layer, the wrapped insulation thickness is approximately 0.36 mm (14 mil) before considering adhesive deformation and surface irregularities. The ASTM D1000 breakdown value of 8,000 V is measured under flat-electrode laboratory conditions; an irregular splice can reduce the effective breakdown strength because of air entrapment, sharp conductor edges, and localized thinning at the tape overlap. The 600 V system rating therefore includes a design margin for imperfect installation. The tape should not be specified for circuits above 600 V or for applications where the peak transient voltage is expected to exceed the insulation coordination level of the equipment.
On rotary taping heads and semi-automated wire processing stations, the unwind tension is controlled to avoid exceeding the backing’s tensile limit. Excessive tension causes necking and reduces the cross-sectional thickness of the PVC film, which can lower the dielectric barrier at the center of the splice. In manual application, pulling the tape to its full elongation of 200% should be avoided because the backing undergoes permanent deformation and the adhesive layer can debond from the film. The tape is supplied on a removable core to allow use with bench dispensers; guide-roller adhesive build-up on automated equipment is a known maintenance point and should be cleaned with a compatible non-chlorinated solvent. Published data for this specific configuration is limited for long-term adhesive transfer on automated tooling.
Pressure-sensitive adhesive tack is temperature-dependent. At normal room temperature, the rubber resin adhesive develops sufficient wet-out on clean copper and PVC surfaces within a few seconds; at reduced temperatures, wet-out is slower and peel adhesion declines. This characteristic makes the tape suitable for bench assembly in controlled indoor environments but less suitable for field installation in cold weather without surface warming. Published data for this specific configuration is limited for quantitative tack decay below 0°C.
Because the 1776 tape is offered in multiple pigments, it is also used for conductor identification in control panels and appliance wiring. The colorant is incorporated into the PVC film rather than applied as a surface ink, which reduces the risk of color loss during routine abrasion. The color is not a substitute for permanent wire marking under code and specification requirements; it serves as an installation aid. The tape’s 0.18 mm (7 mil) thickness adds limited bulk to a wire bundle, and the 25 oz/in (2.7 N/10 mm) adhesion to backing allows an end flag to remain sealed when the final turn is burnished with thumb pressure. Published data for this specific configuration is limited for color-fastness under ultraviolet exposure.
The 1776 tape is positioned within the general-purpose segment of the manufacturer’s vinyl electrical tape range. A comparison with 3M™ Scotch® Super 33+™ Vinyl Electrical Tape illustrates the operational boundary shift for applications involving higher temperature or deeper stretch.
| Property | 3M Temflex™ 1776 | 3M™ Scotch® Super 33+™ |
|---|---|---|
| Nominal thickness | 0.18 mm (7 mil) | 0.18 mm (7 mil) |
| Continuous operating temperature | 80°C (176°F) | 105°C (221°F) |
| Elongation at break | 200% | 250% |
| Adhesion to steel | 25 oz/in (2.7 N/10 mm) | 28 oz/in (3.1 N/10 mm) |
| Working voltage | 600 V | 600 V |
| Typical application class | General-purpose insulation | All-weather, high-temperature insulation |
The principal difference is the continuous thermal ceiling. The 1776 tape uses a general-purpose PVC compound that retains room-temperature elongation but softens at lower temperatures than the higher-temperature all-weather formulation. The published elongation gap of 200% versus 250% indicates that the higher-temperature product tolerates greater mechanical strain before the backing reaches its tensile limit. The adhesion gap of 25 oz/in (2.7 N/10 mm) versus 28 oz/in (3.1 N/10 mm) is small but relevant in overhead or vibration-prone harnesses, where flagging can initiate at the tape end. These differences define the selection boundary when the application approaches the thermal or mechanical limits of the product class.
In panel-building applications, the 19 mm (3/4 in) width is compatible with standard tape dispensers and rotary taping heads, but the roll length of 20 m (66 ft) may require more frequent changeover than longer-length rolls if the production line is configured for jumbo rolls. Changeover intervals influence production takt time on automated harness lines. The tape’s linerless construction eliminates the need for release liner removal and associated waste, but it also means the adhesive is exposed to airborne dust during storage. Rolls should be stored in sealed bags at temperatures below 25°C and out of direct sunlight to limit oxidative degradation of the adhesive. Published data for this specific configuration is limited for adhesive loss after extended storage above 30°C.
Operationally, the 1776 tape is not formulated for continuous immersion in water, direct burial, or prolonged ultraviolet exposure. The plasticized PVC backing can undergo plasticizer migration when exposed to elevated heat, strong solvents, or certain elastomeric cable jackets; this can result in embrittlement and loss of elongation over time. The rubber resin adhesive has limited resistance to aliphatic and aromatic hydrocarbons, and the product should not be specified where the conductor surface temperature exceeds 80°C. In applications requiring cold-weather application below 0°C, the tape should be evaluated on the actual substrate because the pressure-sensitive adhesive loses tack at reduced temperature. Published data for this specific configuration is limited for operation above the continuous temperature rating and for chemical exposure to ketones, esters, and chlorinated solvents. Under the manufacturer’s regulatory documentation, the product family is stated to comply with EU RoHS 2011/65/EU and REACH for the substances declared in the PVC and adhesive formulations. This compliance is product-family level; verification against a specific production lot requires the safety data sheet and supplier declaration.