| HS Code | 669427 |
| Manufacturer | 3M |
| Brand | Temflex |
| Product Line | 1700 |
| Product Name | 3M Temflex 1700 Vinyl Electrical Tape |
| Product Type | Vinyl electrical tape |
| Backing Material | Polyvinyl chloride (PVC) |
| Adhesive Type | Rubber-based pressure-sensitive adhesive |
| Color | Black (other colors available) |
| Thickness | 7 mil (0.18 mm) |
| Width | 3/4 in (19 mm) |
| Length | 60 ft (18.3 m) |
| Temperature Rating | 80 °C (176 °F) |
| Voltage Rating | 600 V |
| Dielectric Strength | 1000 V/mil (39.4 kV/mm) |
| Tensile Strength | 15 lb/in (2.6 kN/m) |
| Elongation At Break | 200% |
| Adhesion To Steel | 20 oz/in (2.2 N/cm) |
| Flame Retardant | Yes |
| Ul Listed | Yes |
| Csa Certified | Yes |
| Rohs Compliant | Yes |
| Chemical Resistance | Moisture, alkalies, acids, and copper corrosion |
| Weather Resistance | Resistant to varying weather conditions |
| Abrasion Resistance | Excellent |
| Primary Application | Insulating, splicing, and marking wire and cable |
As an accredited 3M Temflex™ 1700 Vinyl Electrical Tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 3M Temflex™ 1700 Vinyl Electrical Tape, one 3/4 in x 60 ft black roll, wrapped in plastic with cardboard core. |
| Container Loading (20′ FCL) | 20′ FCL loading: 3M Temflex 1700 Vinyl Electrical Tape, palletized rolls, dry container, evenly distributed and secured for non-hazardous transport. |
| Shipping | 3M Temflex™ 1700 Vinyl Electrical Tape is not regulated as hazardous for transport (no UN number, hazard class, or packing group). Ship in ordinary commercial packaging as non-hazardous general freight. Keep dry, avoid excessive heat and direct sunlight; comply with applicable local, national, and international regulations. |
| Storage | Store 3M Temflex™ 1700 Vinyl Electrical Tape in a cool, dry, well-ventilated area, away from direct sunlight, heat, sparks, flames, acids, alkalis, and strong oxidizers. Keep it in the original packaging, tightly closed, at 15–30°C (59–86°F) and moderate humidity. Avoid freezing, moisture, dust, solvents, and physical damage. Rotate stock and observe the manufacturer’s shelf-life recommendations. |
| Shelf Life | Five years from date of manufacture when stored at 20°C (68°F) and 50% relative humidity in original packaging. |
In modular low-voltage wiring accessory assembly, Temflex 1700 is applied as an overwrap on insulated ring and push-on receptacles before insertion into polycarbonate or polyphenylene ether enclosures. The nominal 0.18 mm backing thickness produces a radial build-up of approximately 0.36 mm when a single half-lapped layer is applied, which is the maximum allowed in flush-mount box designs with 3 mm sidewall clearance. Surface preparation is limited to wiping copper and brass lug surfaces with 99.9% isopropanol on a nonwoven polyester wiper until no oxide residue transfers; chlorinated solvents and ketones are excluded because they extract plasticizer and cause the PVC backing to embrittle. If assembly-area RH exceeds 60%, metal terminals are pre-dried with heated air at 40°C for 30 s before tape application. The tape is applied with a manual tensioner set below backing yield; a half-lap wrap advances one-half of the 19 mm roll width per revolution. The rubber-resin pressure-sensitive adhesive requires 24 h at 23 ± 2°C and 50 ± 5% RH per ASTM D1000 conditioning before dielectric withstanding verification; initial tack alone is not considered an insulation bond. End-product dielectric testing is conducted according to the applicable accessory standard for the assembly, with the tape contributing to conductor spacing rather than acting as sole primary insulation. The finished subassemblies include switch-and-socket modules, flush-mounted dimmer back boxes, and plug-in terminal strips for 250 V branch circuits; the tape carries component listing under UL 510 and CSA C22.2 No. 197, with conformity declarations retained under RoHS Directive 2011/65/EU. Avoid prolonged contact with uncured amine-cured epoxy potting compounds because free amine can plasticize the backing and reduce tensile strength.
Backing necking is the primary process defect when taping bundles of polyester-imide magnet wire and glass-braided leadwire on fractional-horsepower stator lines. Because the PVC backing exhibits an elongation at break of approximately 200% under ASTM D1000, hand tension above the yield threshold reduces cross-sectional area at the overlap edge and creates thin-gauge zones that fail dielectric lot acceptance. The rubber-resin adhesive wetting on esterimide varnished wire is weaker than on bare copper or unplasticized PVC; therefore, lead exit points are wiped with 99.9% ethanol and abraded with 200-grit aluminum oxide paper to increase mechanical keying. Two half-lap layers are applied over the string-laced diamond pattern; each layer advances one-half of a 19 mm roll width. The overlap edge reaches 0.36 mm nominal thickness, which is the design value used in creepage distance calculations under IEC 60664-1. Temflex 1700 is not accepted as a sole interphase insulator when stator varnish dip cycles exceed 100°C, because the tape’s continuous service temperature is limited to 80°C; in such thermal profiles the tape is replaced or supplemented with aramid paper and polyester film. The taped lead assembly is inserted into the terminal box and subjected to the end-product dielectric test of IEC 60034-1, typically 2 U_N + 1000 V for 60 s, with rejection for corona pinholes or flashover. Terminal products include shaded-pole fan motors, evaporator blower motors, and small pump motors under 0.75 kW used in air-moving and hydronic applications.
Household appliance harness assembly uses Temflex 1700 for branch bundling and for over-flag identification on soldered or closed-end connector splices in washing machine, refrigerator, and exhaust hood circuits. On cut-strip-crimp lines, tape is dispensed from a constant-tension roll holder with 25% overlap as an overwrap over PVC-insulated conductors in the 0.5–2.5 mm² cross-sectional range; this lower overlap controls harness diameter growth to under 1.5 mm and avoids exceeding connector backshell clearances. Cross-linked polyethylene and silicone rubber insulation present low-surface-energy bonding surfaces, so the operator pre-wipes the jacket with isopropanol and maintains substrate temperature at 15–20°C before taping; peel adhesion after 20 min dwell is lower than on plasticized PVC but sufficient for bundling, not for structural strain relief. For circuit identification, six coloured PVC tapes are applied as helical flags covering 40 mm of the outer jacket in line with IEC 60445 functional earthing and line conductor colour schemes. The taped harness is routed through strain-relief clamps at 200–250 mm intervals and tested under the relevant clause of IEC 60335-1 for pull-out and creepage clearance. The final harness assembly is declared compliant with RoHS Directive 2011/65/EU based on pigment and stabilizer declarations from the tape supplier. This segment is less process-intensive than motor lead dressing because conductor movement is constrained and the tape function is ancillary rather than primary insulation.
| Reference | Scope | Test/condition | Relevance to Temflex 1700 |
|---|---|---|---|
| UL 510 | PVC insulating tape component listing | Adhesion, tensile strength, elongation, dielectric breakdown, flame performance per ASTM D1000 | Used to qualify splice insulation at 600 V and below |
| CSA C22.2 No. 197 | PVC insulating tape for electrical equipment | Mechanical and electrical properties equivalent to ASTM D1000 | Required for export to Canadian OEM lines |
| ASTM D1000 | Pressure-sensitive adhesive-coated tapes for electrical and electronic applications | 23 ± 2°C, 50 ± 5% RH; peel adhesion, unwind, dielectric breakdown, elongation | Default incoming inspection specification |
| IEC 60454-3-1 | Pressure-sensitive adhesive tapes with PVC film base | Classification framework for thermal index and dielectric properties | Used as comparative benchmark when specifying for IEC-marked equipment |
| RoHS Directive 2011/65/EU Annex II | Restricted substances in electrical equipment | Lead, mercury, cadmium, hexavalent chromium, PBB, PBDE, four phthalates | Supplier declaration retained for EEE assembly |
| REACH Regulation (EC) No 1907/2006 Annex XVII | Restrictions on certain phthalates in articles | Article-level migration risk | Required for EU import documentation |
Industrial control panel wireways operating at 55°C under full load require mechanical separation between low-voltage control circuits and 24 V DC analog signal cables; Temflex 1700 is used as a supplementary divider where cable ties alone cannot maintain the 3 mm spacing specified by UL 508A clearance rules. The failure mode observed on production panel lines is edge lifting caused by adhesive creep during thermal cycling between 23°C and 55°C at 8 h intervals; therefore, the tape is never stretched beyond 10% elongation during application. Above 10% stored strain, the rubber-resin adhesive accumulates shear at the tape edge and lifts from corrugated wire duct sidewalls; published data for this specific configuration is limited, but the failure mode is documented in panel shop lot inspection records. Tape segments are cut with a guillotine-style dispenser to avoid feathered edges, and the first 50 mm and last 50 mm of each wrap are reinforced with a cable tie to anchor the cut end. The PVC backing has a continuous service temperature ceiling of 80°C, which leaves a 25 K margin above the measured 55°C wireway interior; panels operating above this ceiling require a glass-cloth or silicone rubber replacement. Incoming inspection for this application uses ASTM D1000 adhesion and dielectric breakdown tests after 24 h at 23 ± 2°C and 50 ± 5% RH. The final installation consists of separated NFPA 79 wire groups inside steel wire duct, with the tape acting as a visible field-installed separator; it is not accepted as a substitute for a listed terminal block or busbar barrier.
A body-harness repair bay typically handles taped splice repair on circuits routed through rocker panels and under-dash channels, where temperatures remain below 70°C in normal operation. When a wiring harness is repaired after chafe or connector melt, the damaged insulation is stripped back to clean conductor; the crimped or soldered splice is over-wrapped with Temflex 1700 using two half-lap layers, each at 50% overlap. The tape’s contribution is mechanical protection and supplementary electrical separation; it is not a substitute for sealed heat-shrink tubing in wet-floor areas or engine-compartment positions above 80°C. For under-dash splices, the PVC backing is compatible with automotive-grade PVC wire insulation, and the pressure-sensitive adhesive develops sufficient peel force on copper conductor after 15 min dwell at 20–25°C to permit harness reinstallation. In service intervals where the vehicle interior is exposed to 85°C soak conditions, plasticizer migration from the tape backing can cause slight tactile softening of adjacent PVC wire insulation; published data for this specific configuration is limited, so the repair specification restricts use to circuits below 70°C continuous. Lot qualification is performed using ASTM D1000 peel adhesion and UL 510 dielectric requirements after 24 h conditioning; the repair order records tape lot, roll width, and overlap count for traceability. The terminal product is a restored body wiring circuit in climate-control, audio, or exterior lighting harnesses under 12 V DC vehicle architecture.
When field repairs are executed below 10°C without surface preheating, the rubber-resin pressure-sensitive adhesive enters a viscoelastic regime in which bond formation time exceeds the practical dwell window on an unheated switchgear cable or overhead crane conductor rail. Initial tack on bare copper drops steeply as substrate temperature falls from 10°C to 0°C; the PVC backing also stiffens and tends to spring back at the final wrap edge. The accepted procedure is to preheat the conductor and the existing cable jacket with forced hot air from a 1 kW heat gun held 150 mm from the surface for 60 s, raising local skin temperature to 15–20°C before the first wrap. Each successive half-lap layer is then applied without reheating unless the surface drops below 10°C. At the termination point, a silicone rubber fusion tape or a UV-resistant cable jacket is applied over the vinyl tape when the repair is exposed to weather; Temflex 1700 is not rated as a direct-burial or permanently exposed outdoor covering. Compliance with ASTM D1000 adhesion testing requires conditioning of the bonded assembly at 23 ± 2°C for 24 h before destructive peel measurement; field repairs executed at low temperature therefore receive a temporary label stating do not energize above 600 V until 24 h conditioning. The repaired circuit is returned to service as a temporary or permanent low-voltage cable segment in plant maintenance and crane electrification systems where no moisture immersion condition applies.
Competitive 3M Temflex™ 1700 Vinyl Electrical Tape prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
3M Temflex™ 1700 Vinyl Electrical Tape is a general-purpose pressure-sensitive electrical insulating tape formed from a polyvinyl chloride backing and a rubber-resin adhesive. The product is manufactured at a nominal total thickness of 0.18 mm (7 mil) and is commonly supplied in 19 mm × 18.3 m (3/4 in × 60 ft) black rolls, with additional width and length configurations available through regional distribution. It carries a 600 V dry-location electrical rating and is listed under UL 510 and certified to CSA C22.2 No. 197. Intended service includes insulation of wire splices, low-voltage cable joint wrap, wire harness bundling, and phase or circuit identification in original equipment manufacturing and maintenance. The product is not designed as a self-fusing tape or as a substitute for cold-shrink tubing; it functions through the pressure-sensitive adhesive bond to the underlying conductor insulation or to an underlying tape layer.
Conformance is evaluated under ASTM D1000, which describes test procedures for pressure-sensitive adhesive-coated tapes used in electrical and electronic applications. The manufacturer’s published typical values include total tape thickness of 0.18 mm (7 mil), tensile strength of approximately 2.1 kN/m (12 lb/in), elongation at break near 180%, and adhesion to steel of approximately 5.5 N/10 mm (20 oz/in). Short-time dielectric breakdown is typically reported as 8 kV when tested under ASTM D1000 conditions. These values represent central tendencies for typical production lots, not guaranteed minima; sample conditioning, dwell time, and backing orientation all influence measured results.
| Property | Typical value | Test method |
|---|---|---|
| Total tape thickness | 0.18 mm (7 mil) | ASTM D1000 |
| Tensile strength | 2.1 kN/m (12 lb/in) | ASTM D1000 |
| Elongation at break | 180% | ASTM D1000 |
| Adhesion to steel | 5.5 N/10 mm (20 oz/in) | ASTM D1000 |
| Short-time dielectric breakdown | 8 kV | ASTM D1000 |
| Continuous operating temperature | 0°C to 80°C | Manufacturer rating |
| Maximum working voltage | 600 V | UL 510 / CSA C22.2 No. 197 |
Elongation at break is relevant to application technique because spiral wrapping intentionally applies tensile strain to the backing. At 25% elongation, the nominal backing thickness is reduced by necking, and the dielectric coverage per pass is no longer equal to the unstretched value in ASTM D1000 dielectric testing. Production technicians commonly limit applied strain to 10–25% to retain overlap integrity without creating thin spots. At strain levels approaching 180%, the PVC backing undergoes significant plastic deformation and the rubber-resin adhesive may no longer provide uniform wet-out on release or repositioning.
Short-time dielectric breakdown measures the voltage at which a defect, pinhole, filler agglomerate, or adhesive void initiates electrical failure through the thickness. A published value of 8 kV on an unstretched specimen does not imply equivalent performance after mechanical damage, contamination, or extreme elongation. In field service, surface moisture and conductive debris can reduce tracking resistance; therefore the tape is specified for dry, protected electrical enclosures rather than outdoor or submerged locations.
The adhesion-to-steel value is measured after a controlled dwell time on a standard stainless steel panel. In production practice, initial tack on copper or PVC is usually sufficient for immediate handling, but peel strength develops further through adhesive flow during the first 24 h. Peel adhesion on tin-plated copper may be lower than on steel because oxide films and lubricant residues vary. Cleaning with isopropyl alcohol or a compatible electronics-grade solvent improves reproducibility, provided the solvent is allowed to flash off completely before tape application.
On OEM wire-harness fabrication lines, adhesion is developed rapidly after wrapping by applying tension between 10% and 25% of the ultimate elongation. Clean copper conductors, tin-plated copper, and extruded PVC or cross-linked polyethylene insulation are suitable substrates. For heavily plasticized PVC insulation, plasticizer diffusion into the rubber-resin adhesive can soften the bond over time. Low-surface-energy substrates such as silicone rubber, PTFE, and polyethylene require surface oxidation or an alternative tape system because the pressure-sensitive adhesive cannot establish sufficient interfacial contact. Before automated wrapping, harness fabricators typically measure unwind force and adjust guide-roller alignment; published data for high-speed spiral wrapping of this specific tape are limited, so start-up trials are used to establish back tension and cut length.
Batch-to-batch variation in PVC plasticizer content and calendering conditions can shift elongation and unwind force within the manufacturer’s specification. Incoming lot testing under ASTM D1000 is commonly limited to thickness, peel adhesion, and visual inspection; dielectric breakdown and flame retardance are type tests performed on qualification lots. A manufacturing lot that exhibits edge feathering, adhesive transfer to the backing, or erratic unwind force should be quarantined because these conditions alter tape overlap and can leave conductive paths across the wrap boundary.
Automated spiral wrapping heads used in harness assembly include tape tensioners, guide rollers, and cutters. If back tension is too high, the elastic and plastic elongation of the PVC backing causes the tape width to narrow, reducing overlap. If back tension is too low, the tape tends to unwind unevenly and can wrinkle. Because published data for this specific tape on high-speed heads are limited, process engineers typically construct a start-up matrix of tension, speed, and overlap angle to identify a stable window. The acceptable window is often bounded by flagging at low tension and neck-down at high tension.
The polyvinyl chloride backing is compounded with heat stabilizers, flame-retardant additives, and plasticizers sufficient to maintain flexibility near room temperature. Flame retardance in PVC electrical tapes originates primarily from the halogen content of the polymer phase and may be enhanced by antimony-oxide synergists; the full additive package is proprietary. The plasticizer system controls low-temperature stiffness and long-term retention of backing flexibility, but it also creates an interphase with the pressure-sensitive adhesive. Over time, plasticizers can migrate from the backing into the adhesive and reduce cohesive strength, especially above the manufacturer’s 80°C continuous rating. The rubber-resin adhesive is designed for instant pressure-sensitive tack rather than thermosetting cure; it does not crosslink after application, so load-bearing capability is governed by initial peel adhesion and cohesive shear strength.
The PVC backing is produced by compounding resin, plasticizer, filler, pigments, stabilizers, and flame-retardant additives. Compounding may be performed on twin-screw extruders or intensive batch mixers; subsequent calendering or flat-die extrusion produces the 0.18 mm film. Thickness uniformity across the web directly affects dielectric performance and unwind force. Calendering lines use roll gap control and beta-gauge thickness measurement to maintain nominal gauge. In flexible PVC films of this type, plasticizer volatility and migration become more pronounced above 80°C, which is consistent with the product’s upper service rating.
The rubber-resin adhesive is applied to the PVC backing by solvent coating, dispersion coating, or hot-melt coating depending on manufacturing site; the coating process is selected to maintain adhesive thickness and avoid pinholes. Tackifiers raise the glass transition of the adhesive blend above a range that would produce excessive room-temperature flow, but the system remains a pressure-sensitive adhesive rather than a curing adhesive. Because the adhesive is formulated for general-purpose use, it may not maintain peel adhesion on silicone surfaces, highly plasticized jackets, or oily conductors.
Chemical incompatibility arises with strong solvents that extract PVC plasticizer or dissolve tackifying resin. Ketones, chlorinated solvents, and aromatic hydrocarbons can cause backing embrittlement, adhesive softening, or wrapper shrinkage. Exposure to amine-based corrosion inhibitors and certain antioxidant packages in adjacent cable jackets should be evaluated by wrapped-sample testing under service temperature. The tape is not formulated for continuous immersion in water, fuels, or hydraulic fluids; if fluid contact is expected, a sealed outer jacket or a fluid-resistant tape system is required.
Specifying this tape where temperatures remain between 0°C and 80°C is appropriate for indoor general-purpose insulation. Where cold-weather application or sustained elevated temperature is part of the operational envelope, 3M Super 33+ Vinyl Electrical Tape carries a published continuous operating range of -18°C to 105°C and provides higher elongation and conformability on irregular splices. The difference in low-temperature performance is not merely a rating change; PVC backing stiffness increases with decreasing temperature, and the plasticizer system in Temflex 1700 is not formulated for cold impact or cold bending required by some OEM harness specifications. At high temperature, the narrower rating of Temflex 1700 limits its use in engine compartments, industrial lighting ballasts, and heating equipment where surface temperatures exceed 80°C.
The dry-location 600 V rating of Temflex 1700 is similar to many general-purpose PVC tapes, but mechanical toughness and adhesive shear performance differ from heavier products such as 3M Super 88. In repair or maintenance environments where multiple layers are used to build dielectric thickness, the lower tensile strength and elongation of Temflex 1700 require lower wrapping tension to prevent localized thinning. The product is therefore typically selected for light-duty bundling, phase identification, and insulation of low-voltage control wiring rather than for motor lead encapsulation or high-voltage splice reconstruction.
Compared with a self-amalgamating silicone tape, Temflex 1700 requires mechanical overlap and adhesive bonding rather than molecular fusion. It cannot provide a continuous homogeneous dielectric layer at high voltage because the tape layers remain distinct and rely on interfacial adhesion. This difference restricts the product to low-voltage applications where the electrical stress is below the tracking and partial-discharge thresholds of the taped interface.
Compliance verification for the product is tied to UL 510 flammability, dielectric withstand, and physical property tests, with CSA C22.2 No. 197 providing parallel certification for Canadian installations. Although the product passes flame-retardance testing under UL 510, it is not a fire barrier and does not render a wire assembly non-propagating under all fault conditions. Flame retardance is a relative performance characteristic tested under specified specimen geometry and ignition source; field installations with bundled cables may require additional fire-stopping or conduit protection to meet electrical codes.
| Standard / regulation | Designation | Scope |
|---|---|---|
| UL 510 | Standard for Polyvinyl Chloride, Polyethylene, and Rubber Insulating Tape | Component listing for flame retardance, dielectric withstand, physical properties |
| CSA C22.2 No. 197 | PVC insulating tape | Canadian certification |
| RoHS 2011/65/EU as amended | Restriction of hazardous substances in electrical and electronic equipment | Declaration based on supplier data |
| REACH EC 1907/2006 | Registration, evaluation, authorisation and restriction of chemicals | SVHC candidate list disclosure |
Restriction of hazardous substances documentation for this tape generally follows RoHS 2011/65/EU as amended by EU 2015/863. Suppliers may report exemptions under Annex III or Annex IV for lead in copper alloys or other trace contaminants if present; however, a vinyl electrical tape of this class typically contains no intentionally added lead, mercury, cadmium, hexavalent chromium, PBB, or PBDE. REACH EC 1907/2006 SVHC disclosure applies to substances on the candidate list above 0.1% w/w in each article. The absence of SVHCs above the reporting threshold should be confirmed from the current material declaration for the specific manufacturing date because formulations may change under the same product number.
For most indoor electrical assembly operations, the operational boundaries are straightforward: apply only at surface and ambient temperatures above 0°C, do not exceed 80°C continuous service, do not use as sole insulation on wet or direct-burial circuits, and limit wrapping tension to avoid backing thinning. At relative humidity above 60%, condensation on cool conductor surfaces can interrupt adhesive wet-out; pre-drying with clean compressed air or a lint-free wipe may be required. The product should not be combined with strong ketone- or chlorinated-solvent cleaning agents during or immediately after application because plasticizer extraction can cause embrittlement and edge lifting. Extended storage at elevated temperatures accelerates plasticizer loss and reduces tack; rolls should therefore be retained in sealed packaging until use and kept out of direct sunlight.